Alcator C-Mod Run 1120118 Information

Back to runs

Miniproposals
Miniproposal:609a
Date Filed: 9/17/2010
Title:Dependence of momentum and particle pinch on collisionality, R/Ln and q
First Author:John Rice
Session Leader:Tuomas Tala (shots 1-32)

Operators
Session leader(s):Tuomas Tala
Physics operator(s):Jim Irby,Earl Marmar
Engineering operator(s):Roza Tesfaye,Bill Parkin,Bill Byford

Engineering Operator Run Comment
MP609a Feasibility study to create rotation perturbations to investigate

Session Leader Plans
Entered: Jan 17 2012 01:01:19:930PM
Author: Tuomas Tala
Essential diagnostics: Hirex-Sr, Thomson, q-profile (MSE), soft x-ray for impurities

B-side lower enabled, 1 psi Ar.

This shot plan is based on miniproposal 609a and on the run day on 13 January 2011.

For each shot, perform impurity injection (Calcium Fluoride) 200ms before the end of the current flat-top, but after the ICRH or SSEP modulation has been finished so that the impurity injection is under stationary conditions.

Run the locked-mode calibration pulse for Hirex: 1111215017

ICRH modulation part:

There are two ways we try to get a good rotation modulation signal while still keeping the plasma stationary enough (no massive temperature or density modulation).

i) ICRH modulation in L-mode (upper single null configuration) :

Reference shot: 1110217032 --- Bt=5.2T, Ip=0.8MA, nl04=1.3e20m^-2 (this reference pulse is lower single null)

a) Vary the amplitude of the ICRH modulation at 10Hz, Bt=5.4T, Ip=0.8MA, nl04=1.3e20m^-2 in upper single null configuration. Choose the appropriate amplitude that maximises the rotation modulation (~5km/s, ~10% modulation amplitude) and minimises the temperature and density modulation (~<10%). ICRH power modulation at 10% frequency on any level between 0-3MW OK, could be like 1MW base power, modulating then between 1-3MW. Still keep it in L-mode.

b) Perform a 3-point q95 scan by choosing the best modulation settings above.

1) Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2
2) Bt=5.4T, Ip=1.2MA, nl04=0.8e20m^-2
3) Bt=5.4T, Ip=0.5MA, nl04=0.8e20m^-2

c) Perform a 3-point density (collisionality) scan by choosing the best modulation settings above.

1) Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2 (same pulse as in b.1, already done)
2) Bt=5.4T, Ip=0.8MA, nl04=0.4e20m^-2
3) Bt=5.4T, Ip=0.8MA, nl04=1.5e20m^-2

ii) ICRH modulation in L-mode by going to I-mode after every power step-up: Same as before, but going to higher power to get to I-mode.

d) Vary the amplitude of the ICRH modulation at 10Hz, Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2. Choose the appropriate amplitude that maximises the rotation modulation and minimises the temperature and density modulation. ICRH power modulation so that at high ICRH power ~2.5MW ON phase the plasma goes to I-mode and then at 0MW RF power OFF phase it returns to L-mode.

e) Perform a 3-point q95 scan by using the scheme above.

1) Bt=5.4T, Ip=0.8MA, nl04=1.3e20m^-2
2) Bt=5.4T, Ip=1.2MA, nl04=1.3e20m^-2
3) Bt=5.4T, Ip=0.5MA, nl04=1.3e20m^-2


f) Perform a 3-point density (collisionality scan) by modulating ICRH power between 0-3MW, the actual modulation amplitude to be chosen from looking into after a few test pulses the data at 10Hz modulation frequency.

1) Bt=5.4T, Ip=0.8MA, nl04=1.3e20m^-2 (same pulse as in e.1, already done)
2) Bt=5.4T, Ip=0.8MA, nl04=2.0e20m^-2
3) Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2

SSEP sweep part:

Reference shot: 1110113030 --- Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2, Ohmic

Try to increase the rotation modulation amplitude while not disrupting the shot. Higher SSEP amplitude, slower modulation time, now 70ms, would be the things to try. Run all the pulses at higher rotation as the effect on rotation should be more visible then.

Repeat at a factor of 2 higher density (Bt=5.4T, Ip=0.8MA, nl04=1.6e20m^-2)
Repeat at higher Bt and Ip (Bt=7T, Ip=1.1MA, nl04=1.6e20m^-2)
Repeat at lower Bt and Ip (Bt=3.4T, Ip=0.5MA, nl04=1.6e20m^-2)

Physics Operators Plans
Entered: Jan 18 2012 06:56:43:313AM
Author: Earl Marmar
PO plan for 18 Jan 2012

MP609a Feasibility study to create rotation perturbations to investigate the dependence of momentum pinch on collisionality, R/Ln and q

SL: T. Tala
PO: E. Marmar

-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Power systems as on: 1120106024 (locked-mode shot)

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

B-Top with 6 psi D2 Hybrid enabled (PG4)
B-side lower with 1 psi Ar Hybrid ENABLED(PG1)
B-side upper as is Hybrid DISABLED (PG2)
B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
H-bot as is, Hybrid DISABLED (PG5)
NINJA as is, Hybrid DISABLED

B-div, Hybrid DISABLED (PG6)
H-div, Hybrid DISABLED (PG7)

Enable gate-valves and shutters: ECE, VUV, HiREX Sr, Xeus + LoWEUS, Zbolo

Check with the physop before opening other diagnostic gate-valves or shutters.

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): YES
ICRF(yes/no): YES
LH(yes/no): not into plasma
Cryopump (yes/no): yes
DNB (yes/no): yes
Impurity blow-off injection: yes

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters
------------------------------
gas and pressure: D2 at 2e-4 Torr
sweep: 44/45/103 cm
scan: 20/120 s

After a successful locked-mode shot, move to USN; see SL_PLAN for shot sequence.

Session Leader Summaries
Entered: Jan 19 2012 03:01:24:600PM
Author: Tuomas Tala
This run day had lots of technical difficulties, in particular in the early part of the run.

In the first part of the program, the modulation between the I-mode and L-mode was tried, but probably the power level of the ICRH was too low so that I-mode was achieved.

As a consequence, the main effort and most of the shots were spent on performing ICRH modulation in L-mode using the upper single null configuration. Most of the shots had the RF modulation between 0 and 1.7MW (or 1.0MW and 2.7MW), for one shot (shot 13) we decreased it to 0 and 1.2MW and the rotation modulation virtually disappeared. The pulse length was extended to 1.6s to accomodate the impurity injection at 1.5s after the RF modulation phase.

Physics scans that were fully or partly successful:

Density scans:

1120118015 Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2 (decent rotation modulation, also high temperature modulation)
1120118027 Bt=5.4T, Ip=0.8MA, nl04=1.3e20m^-2 (disrupted after 1.3s, rotation modulation probably OK)
1120118022 Bt=5.4T, Ip=0.8MA, nl04=0.5e20m^-2 (modulation probably OK)

q95 scan at higher density:

1120118015 Bt=5.4T, Ip=0.8MA, nl04=0.8e20m^-2 (decent rotation modulation, also high temperature modulation)
1120118017 Bt=5.4T, Ip=1.1MA, nl04=0.8e20m^-2 (disrupted at 1.2s)

q95 scan at lower density:

1120118023 Bt=5.4T, Ip=0.6MA, nl04=0.6e20m^-2 (modulation probably OK)
1120118022 Bt=5.4T, Ip=0.8MA, nl04=0.5e20m^-2 (modulation probably OK)
1120118024 Bt=5.4T, Ip=1.0MA, nl04=0.6e20m^-2 (rotation modulation seems small, also Te modulation smaller than in the shots of this scan)


Move to the SSEP part of the program:

It was a difficult task to dial up the reference shot 1110113030 as it tended to disrupt in an early phase of the shot. Only two shots with a few modulation cycles before the disruption achieved - 1120118031 and 1120118032. However, the rotation modulation looks smaller than in the old reference shot.

Future plans:

To complete this miniproposal and this ITPA experiment, two other ways to modulate the rotation should be done. In a reversed field plasma, modulate RF power between the L-mode and I-mode phases. This has the benefit that rotation perturbation is coming from the edge and the analysis is simplified. The second method should be that during a steady I-mode plasma, modulate RF power on top as also in this case, we can expect the rotation modulation originating dominantly from the edge.

Physics Operator Summaries
Entered: Jan 25 2012 05:20:12:247PM
Author: Earl Marmar
MP609a Feasibility study to create rotation perturbations to investigate the dependence of momentum pinch on collisionality, R/Ln and q

SL: T. Tala
PO: E. Marmar

We had some difficulties today, but a portion of the run plan was carried out.

After a successful locked-mode shot, we had a problem on shot 2, apparently the result of loading a reversed field shot into PCS. Following the SL plan, 1110217032 was loaded. However, the PO realized that this was a reversed-field shot, the intention was to import and then load 1101208005, and I thought I had done that. However, after the shot (which was a dud, with no TF prior to t=0, and PF currents in the wrong direction), I checked the active PCS interface, and the active segments (1 and 2) still had provenance of 1110217032. This means that the "load from" 1101208005 never took, or I typed the wrong shot number. When I did the second last load before the shot, pcs gave me an error message indicating that the fizzle sequence shot had the wrong polarity for the TF, and I misinterpreted this, thinking it was a hold-over from the previous load. After changing the fizzle sequence to the correct shot, I loaded again, and the dud resulted. This also led to various faults on PF commutation systems, which were reset after shot 3, which was another dud. Shot 3 also had no TF. Shot 4 was a 50 kA TF only test, which was fine. Shot 5 was another attempt using 1101208005, which fizzled. Shot 6 was a plasma. This one disrupted at 1.1 seconds, looking vertically unstable. It also had a neon puff (pg5 enabled), which was not intended. After several disruptions, and an init_failure no-power shot (11), shot 12 was the first full-length USN discharge. From shot 28 on, we went to the SSEP sweep part of the run-plan; these discharges mostly disrupted in the middle of Ip flattop.

Summary:

Shot,Duration(s),Ipmax(MA),Result Shot,Duration(s),Ipmax,Result
| 01 1.150 0.836 Plasma | 02 0.000 0.025 Dud |
| 03 0.000 0.032 Dud | 04 0.000 0.004 Dud |
| 05 0.000 0.033 Fizzle | 06 1.073 1.108 Plasma |
| 07 0.000 0.035 Fizzle | 08 1.453 0.912 Plasma |
| 09 1.265 0.906 Plasma | 10 0.000 0.043 Fizzle |
| 11 0.000 0.003 Dud | 12 1.944 0.812 Plasma |
| 13 1.641 0.817 Plasma | 14 1.633 0.810 Plasma |
| 15 2.030 0.808 Plasma | 16 0.000 0.045 Fizzle |
| 17 1.260 1.129 Plasma | 18 0.000 0.053 Fizzle |
| 19 0.360 0.510 Plasma | 20 1.961 0.695 Plasma |
| 21 0.000 0.044 Fizzle | 22 2.030 0.819 Plasma |
| 23 2.030 0.702 Plasma | 24 1.630 1.010 Plasma |
| 25 1.462 0.814 Plasma | 26 0.000 0.052 Fizzle |
| 27 1.337 0.813 Plasma | 28 0.000 0.053 Fizzle |
| 29 0.365 0.575 Plasma | 30 1.062 0.804 Plasma |
| 31 1.261 0.808 Plasma | 32 1.152 0.811 Plasma |

Date 1120118: 32 shots. 20 plasmas. 8 fizzles. 4 duds. 0 System Error.
(Plasma = Ip gt 60.0 kA Dud = H_alpha lt 0.10 V)
Total plasma duration: 28.10 s (exceeding -83 kA)

Session Leader Comments
Jan 18 2012 09:36:48:923AM1120118001Tuomas TalaLocked-mode reference pulse for Hirex calibration. Locked but probably not good enough for the calibration. May need to be repeated later during the run,
Jan 18 2012 09:58:29:087AM1120118002Tuomas TalaI-mode test by modulating ICRH between 1-3MW. The TF waveform very strange, repeating the pulse.
Jan 18 2012 10:29:43:427AM1120118003Tuomas TalaI-mode test by modulating ICRH between 1-3MW. Same as before, TF waveform very strange, go to TF test.
Jan 18 2012 10:30:34:580AM1120118004Tuomas TalaTF test pulse. Worked.
Jan 18 2012 11:01:49:580AM1120118005Tuomas TalaBack to the program to make the I-mode pulse. Did not work.
Jan 18 2012 11:24:21:000AM1120118006Tuomas TalaDisrupted at 1.05s.
Jan 18 2012 11:30:59:327AM1120118007Tuomas TalaNot a proper shot, typical problems after the disruption.
Jan 18 2012 11:56:05:907AM1120118009Tuomas TalaDisrupted at 1.25s, has some 7 ICRH modulation cycles and stationary density. Ip=0.9MA.
Jan 18 2012 12:12:04:120PM1120118010Tuomas TalaNot a decent physics shot.
Jan 18 2012 12:56:24:237PM1120118011Tuomas TalaNot a physics shot.
Jan 18 2012 01:06:48:437PM1120118012Tuomas TalaFirst shot that has all the modulation cycles between 0.5-1s. Clear rotation modulation, also clear Te and Ti modulation of the order of 10%. Density modulation small.

Decrease the RF power modulation from 1.7MW to 1.2MW and extend the pulse length by 100ms to inject impurities at 1.5s.
Jan 18 2012 01:12:26:487PM1120118013Tuomas TalaDecreased the RF power modulation from 1.7MW to 1.2MW and extended the pulse length by 100ms to inject impurities at 1.5s.

RF power tripped, the density non-stationary. Looks like the rotation modulation disappears. Impurity puffed at 1.5s.
Jan 18 2012 01:36:45:497PM1120118014Tuomas TalaWent through until 1.6s, but rotation modulation much smaller. In the next shot remove the steady RF part so that the modulation is between 0-1.7MW as the rotation modulation is much larger during that phase.
Jan 18 2012 01:40:08:660PM1120118015Tuomas TalaThe RF modulation is between 0-1.7MW as the rotation modulation is much larger during that phase.

A good pulse (reference case for the density and q95 scans) with impurity injection at 1.5s.
Jan 18 2012 01:40:52:817PM1120118016Tuomas Talaq95 scan, go to higher current at 1.1MA. Keep the density the same.

Not a physics pulse.
Jan 18 2012 01:59:49:137PM1120118017Tuomas TalaRepeat the same pulse, q95 scan, go to higher current at 1.1MA. Disrupted at 1.25s. Still a few good cycles, rotation modulation significantly smaller than at low current (Ti modulation still very clear).


Jan 18 2012 02:07:36:627PM1120118018Tuomas TalaGo to low current 0.6MA in the q95 scan. No pulse.

Jan 18 2012 02:22:23:267PM1120118019Tuomas TalaGo to low current at 0.6MA in the q95 scan. Early disruption.

Jan 18 2012 02:44:11:740PM1120118020Tuomas TalaRepeat. Very strange shot, density modulating wildly. Not a useful physics pulse although otherwise interesting shot.
Jan 18 2012 02:47:04:493PM1120118021Tuomas TalaGo to density scan, repeating pulse 15 but at low density 0.5e^20. No plasma.
Jan 18 2012 03:09:12:427PM1120118022Tuomas TalaGo to density scan, repeating pulse 15 but at low density 0.5e^20. Good pulse with clean RF waveform and density, but the rotation signal maybe weak.
Jan 18 2012 03:19:32:090PM1120118023Tuomas TalaGoing back to q95 scan but at lower density (same as in the previous shot). So, not a perfect q95 scan. Relatively steady shot with good modulation.


Jan 18 2012 03:31:43:997PM1120118024Tuomas TalaGoing back to q95 scan but at lower density but carry out a high current Ip=1.0MA case. A good shot, but no rotation modulation forwhatever reason. This completed the q95 scan although the high current shot does not give any modulation data.


Jan 18 2012 04:27:05:660PM1120118025Tuomas TalaDoing the high density point in the density scan, nl04=1.3e20. Did not work out nicely, density behaviour irraticm RF modulation tripping.
Jan 18 2012 03:56:55:847PM1120118026Tuomas TalaDoing the high density point in the density scan, nl04=1.3e20. Not a physics pulse.
Jan 18 2012 04:15:35:993PM1120118027Tuomas TalaDoing the high density point in the density scan, nl04=1.3e20. Looks OK from the density and RF point of view.
Jan 18 2012 04:19:05:010PM1120118028Tuomas TalaMove to the SSEP part of the program. Repeat the reference pulse 1110113030. Not a physics pulse.
Jan 18 2012 04:34:52:990PM1120118029Tuomas TalaRepeat the previous one. Disrupted at 0.3s.
Jan 18 2012 04:54:06:157PM1120118030Tuomas TalaRepeat the previous one. Disrupted at 1.05s. It looks like no modulation is coming from the SSEP which also looks very small.
Jan 18 2012 05:05:37:373PM1120118032Tuomas TalaRepeat the previous one. Disrupted at 1.25s. Rotation modulation still looks very small if not zero.
Jan 18 2012 05:14:28:660PM1120118032Tuomas TalaRepeat the previous one. Disrupted at 1.2s. Rotation modulation still looks very small if not zero.

Physics Operator Comments
Jan 18 2012 08:45:45:540AM1120118001Jim Irbyloaded 1120106024 --- locked mode shot
open tree done

prefill at 16 ms
pg1 from 300 to 600 ms --- Argon at 1 psi

Jan 18 2012 09:50:00:933AM1120118001Earl Marmarlocked mode shot (from 1120106024)

plasma
locked around .55s, disrupt at 1.15s
some early hards


Jan 18 2012 11:03:01:077AM1120118002Earl Marmargo to upper null, 1.1 MA, cryopump startup (50 ms prefill puff)

load from 1101208005
recalculate magnetics for segments 1 and 2
zero segments 3 and 4
change dpcs_fizzle target shot to 1090731017

dud, many missing power supplies

For reasons I don't understand, actually had 1110217032 in segments 1 and 2, not 1101208005. The former was a reversed TF/OH shot (positive current programmed for TF). I had loaded from 1110217032 prior to loading from 1101208005, but somehow the second "load from" did not go through.

This was not a case of forgetting to load; after the shot, in the DPCS interface, the source boxes for both segments 1 and 2 showed 1110217032.


Jan 18 2012 10:26:54:580AM1120118003Earl Marmargo to upper null, 1.1 MA, cryopump startup (50 ms prefill puff)

load from 1101208005
recalculate magnetics for segments 1 and 2
zero segments 3 and 4

dud, no TF, all other supplies went


Jan 18 2012 10:26:38:120AM1120118004Earl Marmar50 kA TF only test, PLC control

looks ok
Jan 18 2012 10:54:08:053AM1120118005Earl Marmaranother attempt at 1.1 MA, USN, with cryopump

fizzle
supplies look ok

BR looks too negative, fill pressure a tad high
Jan 18 2012 11:21:17:657AM1120118006Earl MarmarBR_0 offset to +0.001 (from 0.000)
prefill puff to 45 ms (from 50 ms)

plasma, disrupt at 1.1 s
looks vertically unstable

turns out PG5 was enabled, with neon puff starting at 0.5 s
Jan 18 2012 11:29:05:107AM1120118007Earl MarmarIp to 0.9 MA
nl_04 to 9e19
ZCUR to +.005 (from -.005)
disable H-bottom (neon)
zero PG5 puff in segment 2

fizzle
almost no current
Jan 18 2012 12:08:57:587PM1120118008Earl Marmarno DPCS changes

plasma
disrupt at 1.45 s, vertical

H/(H+D) ~15%
Jan 18 2012 12:03:33:747PM1120118009Earl Marmarprefill puff to 42 ms (from 45)
increase Ar (PG1) to 150 ms puff (from 75)
ZCUR to +.01 (from +.005)
ZXL to -.06 (from -.05)

plasma
disrupt at 1.25
Jan 18 2012 12:08:06:453PM1120118010Earl MarmarZXL to -.05 (from -.06)
ZXU to +0.01 (from +0.015)
Ip to 0.8 MA
nl_04 target to 8e19

fizzle, late breakdown
Jan 18 2012 12:20:49:420PM1120118011Earl Marmarno dpcs changes

no power shot
critical failure during init (RF?)
Jan 18 2012 12:36:50:077PM1120118012Earl MarmarZXL to -.04 (from -.05)

plasma, full length
Jan 18 2012 01:07:18:293PM1120118013Earl Marmarextend flattop 1.6 s

plasma,

disrupt just after end of flattop

strange density time history on this shot
Jan 18 2012 01:07:44:360PM1120118014Earl Marmarno dpcs changes
Jan 18 2012 01:33:13:963PM1120118015Earl Marmarsmall tweak to ZXL (ramping through the flattop to reach -.03 at 1.6 s)

plasma, full length
Jan 18 2012 01:49:10:570PM1120118016Earl MarmarIp to 1.1 MA, no change to nl_04 target (still 8e19)

fizzle, late breakdown

f-side ratiomatic significantly higher at t=0 than on recent good shots (cyro-burp?)
Jan 18 2012 02:26:21:903PM1120118017Earl Marmart<0 EF4 current to -1310A (from -1290)

plasma
disrupt at 1.25 s
Jan 18 2012 02:08:45:800PM1120118018Earl MarmarIp to 0.6 MA

fizzle
fill pressure looks ok
breakdown not late
(post 1.1 MA disruption fizzle?)
Jan 18 2012 02:27:20:680PM1120118019Earl Marmarno dpcs changes
plasma
disrupt at 0.35s
Jan 18 2012 02:43:23:080PM1120118020Earl Marmartweak early segment 2 current waveform
flattop target still 0.6 MA

plasma, nearly full-length
strange modulated density behavior during RF modulation

Jan 18 2012 02:50:56:053PM1120118021Earl Marmarreload 1120118015 (0.8 MA)
nl_04 target to 5e19

fizzle
should probably not have taken segment 1 from shot 15 (EF4 offset change)

Jan 18 2012 03:10:54:453PM1120118022Earl Marmarimport segment 1 from 1120118020 into segment 1

plasma, full length

Jan 18 2012 03:55:11:607PM1120118023Earl MarmarArgon (PG1) to 200 ms (from 150)
Ip to 0.6 MA

plasma, full length
Jan 18 2012 03:35:26:607PM1120118024Earl MarmarIp to 1.0 MA
nl_04 target still 0.5e20

plasma
disrupt at 1.63 s

Jan 18 2012 03:44:35:413PM1120118025Earl Marmarload from shot 22 (0.8 MA)

nl_04 target to 1.3e20

plasma, disrupt at 1.46 s

marfing throughout (too much argon?)
Jan 18 2012 03:53:55:950PM1120118026Earl Marmarargon (PG1) puff to 100 ms (from 150)

fizzle
Jan 18 2012 04:05:22:907PM1120118027Earl Marmarprefill puff to 40 ms (from 42)

plasma, disrupt at 1.33s
Jan 18 2012 04:20:21:727PM1120118028Earl Marmarload from 1110113030
DN, with small SSEP sweeps
import segment 1 from 1120118027 into segment 1
zero segments 2 and 4
recalculate magnetics in segment 3
argon (PG1) to 150 ms (from 250)

fizzle
fields, breakdown time look ok
ratiomatic tripped on previous disruption, off for this shot
Jan 18 2012 04:54:40:950PM1120118029Earl Marmarno dpcs changes

plasma
early disruption, lots of marfe-like activity prior to the disruption
Jan 18 2012 04:55:05:103PM1120118030Earl Marmarno dpcs changes

plasma
disrupt at 1.05s
Jan 18 2012 04:58:27:793PM1120118031Earl Marmarnl_04 target to 8e19 (from 9.5e19)
argon (PG1) to 250 ms (from 150)

plasma, disrupt at 1.25 s
Jan 18 2012 05:19:14:887PM1120118032Earl Marmarincrease amplitude of ZCUR modulations; now from -7mm to +1 mm (previously -7mm to 0)

plasma, disrupt at 1.15s (went up)

Engineering Operator Comments
ShotTimeTypeStatusComment
109:18:09:280AMPlasmaOk
209:50:15:723AMPlasmaBadno EF2 and EF3
310:06:07:937AMPlasmaBadno TF
410:19:11:813AMTestOkTF looks okay
510:45:08:960AMPlasmaOk
611:01:08:593AMPlasmaOk
711:18:58:033AMPlasmaOk
811:32:20:297AMPlasmaOk
911:47:31:350AMPlasmaOk
1012:02:17:007PMPlasmaOk
1112:15:35:563PMPlasmaBadno power shot Critical Failure in init.
1212:34:08:327PMPlasmaOk
1312:52:33:503PMPlasmaOk
1401:07:22:330PMPlasmaOk
1501:21:45:417PMPlasmaOk
1601:35:15:350PMPlasmaOk
1701:48:07:643PMPlasmaOk
1802:03:01:417PMPlasmaOk
1902:15:51:390PMPlasmaOkPF Breaker oped after the plasma disrupted
2002:29:04:090PMPlasmaOk
2102:43:55:997PMPlasmaOk
2202:56:41:793PMPlasmaOk
2303:09:28:283PMPlasmaOk
2403:22:22:863PMPlasmaOk
2503:35:18:800PMPlasmaOk
2603:48:24:720PMPlasmaOk
2704:01:08:273PMPlasmaOk
2804:15:00:390PMPlasmaOk
2904:27:38:813PMPlasmaOk
3004:40:21:437PMPlasmaOk
3104:53:10:817PMPlasmaOk
3205:05:58:997PMPlasmaOk

System Availability
Jan 18 2012 09:17:47:683AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennagolfit
BESyesBES system is onlineNov 22 2011 02:21PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
Bolometersyes2pi and midplane AXUV diodes awaiting first plasma. Divertor diodes installed, but amplifiers need to be installed. Core and divertor bolometry not yet hooked upNov 17 2011 02:45PM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoBottle Removed. System has been tested and will be ready once bottle is installedJan 09 2012 06:32AM (dekow)Jim IrbyBoronizationdekow,irby
CECEno Jan 06 2012 03:48PM Anne WhiteCorrelation ECEwhitea
CNPAyesMultiple channel CNPA available, no safety risk for in-vessel accessApr 14 2011 12:01PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesOperational. He level meter not working on 500L dewar. Frank will take manual readings.Jan 11 2012 11:46AM (labombard)Brian LaBombardUpper Divertor Cryopumpdekow,irby,labombard
CXRSyescore-CXRS system is onlineNov 22 2011 02:21PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
CXRS edgeyesMichael CHurchill has primary responsibility at the momentApr 19 2011 11:44AM (blip)Bruce LipshultzMeasurement of CXR light in the pedestal region at both the high- and low-field sidesblip,rmchurch
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsanosystem is is installed and aligned, but not functional (appears to be a broken cable)Dec 05 2011 02:41PM (marmar)Earl MarmarVisible Bremsstrahlung Imagingmarmar
Disruption Mitigationnogas jet valve disabled on 2011/04/13Apr 13 2011 02:04PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DMBolo AXUV diodesnoDiodes are taking data, but system is not fully operational yet. Post-acquisition data processing code is not yet functional.Dec 02 2011 03:27PM (golynyk)Geoff OlynykSet of six AXUV diodes in a toroidal array of midplane wall boxes.golynyk,granetz,mlreinke,whyte
DNByes Dec 01 2011 11:46AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,mochung
ECDCyesOperational as of 11/19/11Nov 22 2011 03:01PM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEnoPower off to RF and IF sections- Power on to DAApr 11 2011 02:54PM (phillips)Perry PhillipsHeterodyne ECE-32 channelsbespam,liao,phillips,rowan,whitea
FTCIno Jan 06 2012 04:36PM Jim IrbyFast two-color interferometerirby
G-Side Ratiomaticyes Dec 02 2011 12:24PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoPower supply unplugged and redtagged, HV cables removedApr 14 2011 08:03AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesUsing new preamps.Nov 30 2011 07:51AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPC2yesDewar cold. Nov 21 2011 09:55AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyessystem is functional and taking dataDec 05 2011 02:42PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Jan 09 2012 06:32AM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SryesInstalled and aligned. Will be available for Ti/Vr profiles after focusing tests and locked modes are taken.Dec 06 2011 08:21AM (ypodpaly)John RiceHigh Resolution X-Raycgao,ldelgado,rice,ypodpaly
HXRyes32 Channels operational,, no safety risk for in-vessel accessApr 14 2011 12:05PM (parker)Ron ParkerHard X-Ray Arrayfaust,parker,schmidt
ICRF D-AntennanosecuredApr 14 2011 08:55AM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-AntennanosecuredApr 14 2011 08:55AM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-AntennanosecuredApr 14 2011 08:56AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Impurity SpectroscopyyesBeing upgraded with better optics and new spectrographs. Dan Miller has primary responsibility.Apr 19 2011 11:46AM (blip)Bruce LipshultzMeasurement of recycling light and impurity source rates at multiple surfaces around the tokamakblip,miller
Laser Blow-OffyesOperational and testedJan 06 2012 03:50PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoLH HV Breaker Opened and Tagged, TPS Upgrade UnderwayNov 10 2011 03:51PM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
Lower Hybrid ReflectometernooffApr 15 2011 08:24AM (dominguez)Arturo DominguezLower Hybrid Reflectometerdominguez,marmar,parker,sgbaek
LoWEUSyesLoWEUS working with the shot cycle. Viewing Mo line-emission normally covered by McPherson. Raw data only in tree.Dec 01 2011 02:54PM (mlreinke)Matthew L. Reinke Long Wavelength Extreme Ultraviolet Spectrometermarkchil,mlreinke
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphanoMidplane Lyman awaiting first plasma. B-PORT and LEDGE arrays installed but do not yet have amplifiers hooked up.Nov 17 2011 02:42PM (mlreinke)Matt ReinkeLyman alpha camerasfaustian,labombard,mlreinke
Magneticsyes Dec 01 2011 11:51AM (g)Robert GranetzBp coils and flux loops for equilibrium controlgranetz,wolfe
McPhersonnonew turbo pump, installed, McP pumping down. Almost ready to open to machine.Dec 06 2011 12:16PM (mlreinke)Jim TerryVUV Spectrometermarkchil,mlreinke,terry
MichelsonyesFront end at 4.5e-8 T. Reduced speed for initial operation.Nov 30 2011 07:51AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyes Dec 02 2011 12:27PM (toland)Brian LaBombardBaratron pressure gaugeslabombard,toland
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEno1/3/2011: push-pull mechanism broken. MSE inoperativeJan 03 2012 11:47AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesHigh voltage is on. We're ready for plasma.Nov 21 2011 12:58PM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesAll detectors Powered On --- Waiting for neutrons for calibrationNov 22 2011 01:05PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAyesC-bottom and new F-bottom system ready.Dec 02 2011 12:28PM (toland)Brian LaBombardNINJA gas pufflabombard,terry,toland
PCIyesOperational.Nov 30 2011 12:45PM (ntsujii)Miklos PorkolabPhase Contrast Imagingemd,ennever,ntsujii,porkolab
Penning GaugesyesOperational. High voltage comes on during INIT and off at RECOOL.Dec 09 2011 09:48AM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
Polarimeteryes3 chords operational but with high noise levelJan 06 2012 04:22PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Jan 09 2012 06:33AM (dekow)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Jan 09 2012 06:33AM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Jan 09 2012 06:33AM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Jan 09 2012 06:33AM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational, except for probe #1 (open circuit) and probe #16 (not installed).Dec 09 2011 09:50AM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational, except for bottom-D probe (open circuit).Dec 09 2011 09:52AM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesF-divertor ok. J-divertor ok, except for JDIV_06 which is shorted out.Dec 09 2011 09:54AM (labombard)Brian LaBombardOuter Lower Divertor Probe Array (F and J)labombard
Probe Array - UDIVyesOperational except for probes #4, 5 and 13 (open)Dec 09 2011 09:56AM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesAs of 1120105xxx, all channels are connectedJan 05 2012 09:14AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesIon Sensitive Probe head installed. Testing in piggy-back mode.Dec 20 2011 12:33PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.Dec 09 2011 09:57AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA-port WASP is operational. K-port WASP is dead (all probes melted together).Dec 09 2011 09:58AM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
Shoelace AntennayesFixed frequency operation available (100kHz) at moderate power (< 0.5kW). Otherwise in receiver mode.Jan 11 2012 11:50AM (labombard)Brian LaBombardHigh-k active MHD antenna, for QCM, WCM studiesgolfit,labombard
SOL reflectometeryesc-port waveguides operational, h-port waveguides are not.Nov 29 2011 12:04PM (cornwall)Cornwall LauSOL reflectometercornwall,wukitch,ylin
SparkeryesNew Type II sparker replaced Type I on 11/17/2011Nov 23 2011 08:53AM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationnoSSS is up to air, no safety issuesApr 14 2011 12:06PM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesTCI Operational. Density feedback operational.Nov 10 2011 11:47AM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CorenoAll lasers are shut down and cannot be fired into cell.Apr 11 2011 01:20PM (jwhughes)Jerry HughesCore Thomson scatteringjrwalk,jwhughes,yma
TS - EdgenoAll lasers are shut down and cannot be fired into cell.Apr 11 2011 01:20PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjrwalk,jwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesXEUS working with the shot cycle. Viewing low-Z emission.Dec 01 2011 02:55PM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermarkchil,mlreinke
XTOMOyesARRAY1->4 waiting first plasma, new core ARRAY5 needs debugging and the calibration data checkedNov 17 2011 02:44PM (mlreinke)Robert GranetzX-Ray Tomographyfaustian,granetz,mlreinke