Alcator C-Mod Run 1120216 Information

Back to runs

Miniproposals
Miniproposal:672
Date Filed:11/7/2011
Title:Nonlocality and possible correlation with rotation reversal
First Author:John Rice
Session Leader:John Rice (shots 1-31)

Operators
Session leader(s):John Rice
Physics operator(s):Steve Wolfe
Engineering operator(s):Andy Pfeiffer,Bill Parkin,Bill Byford

Engineering Operator Run Comment
MP:672 Cold pulses, non-diffusive transport SL: Rice PO: wolfe

Session Leader Plans
Entered: Feb 15 2012 02:52:38:400PM
Author: John Rice
in support of MP 672

run locked mode shot for HirexSr calibration: 1120215002

load 1120106021 except at 1.1 MA
perform shot by shot density scans with ne_ave = 0.6, 0.8, 1.0, 1.2, 1.4
run slight density ramp from ne_ave = 1.0-1.2

repeat locked mode

repeat at 0.55 MA with ne_ave = 0.3, 0.5, 0.7, 0.9, 1.1. run a ramp from 0.5-0.6

repeat locked mode

time permitting repeat at 0.8 MA

repeat locked mode

require HirexSr, LBO, PCI, Thomson, GPC, FRCECE, GPI

LSN. if problem with low density points, try USN w/cryopump

require argon seeding

Physics Operators Plans
Entered: Feb 15 2012 04:19:24:057PM
Author: Steve Wolfe
PO plan for Thursday, Feb 16, 2012
MP:672 Cold pulses, non-diffusive transport
SL: Rice
PO: wolfe

-----------------
Engineering Setup
-----------------
Run begins at 09:00 and ends at 17:00

Power systems as on: 1120106021

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 1 psi Ar Hybrid enabled (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main with 40 psi D2 Hybrid enabled (PG3)
pump out H-bottom, H-BOT,B-DIV,and H-DIV hybrid DISABLED
fill NINJA with 10 psi He4 DISABLED

Enable gate-valves and shutters: ECE, VUV, HiREX Sr, Xeus
Leave z-bolo shutter as is (should be open) 

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes, in Helium
ICRF(yes/no): no
LH(yes/no): no
Cryopump (yes/no): on standby, not on for first shots. Operator on call. 
DNB (yes/no): no

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters (if requested)
------------------------------
gas and pressure: He at 5e-5 Torr
sweep: 44/45/103 cm
scan: 20/120 s

----------------------------------------
Physics Operator Plan:

0. Start from a locked mode shot 1120215002
1. Load from 1120106021 seg2 is LSN, seg3 is USN
   In seg2, modify Ip from 0.8 to 1.1MA
   note argon puff on pg1 is 200msec. Add or subtract to SL's taste. 
  A) Density scan:
     nebar = 0.6, 0.8, 1.0, 1.2, 1.4
     nl04 = 3.5,4.6,5.8,7.0,8.1e20
  B) dynamic density scan from .7 to .8e20
2. Repeat locked mode
3. Reduce current to 0.55MA 
  A) density scan 
     nebar = 0.3, 0.5, 0.7, 0.9, 1.1 
     nl04 =  0.2,0.3,0.4,0,5,0.65
  B) density ramp from .3 to .4
4. Repeat locked mode shot
5. Current back to 0.8MA and repeat (if there's time)

If we run into trouble getting the lower density then we will change to
USN (as in seg3) and use the cryopump

Session Leader Summaries
Entered: Feb 16 2012 05:07:45:727PM
Author: John Rice
very successful run.
density scans at 2 currents, 1.1 and 0.55 MA
density ramps at 0.55, 0.8 and 1.1 MA
good rotation reversal data
excellent injections on all discharges, good ECE data.
PCI operational
new results from GPI showing a fast feature which appears only in the SOC regime,
which complements the LOC feature on the PCI.

Physics Operator Summaries
Entered: Feb 17 2012 07:39:34:623AM
Author: Steve Wolfe
Physop Summary for Thursday, Feb 16, 2012
MP#672 (cold pulses,rotation reversals, and non-diffusive transport)
SL: Rice
PO: wolfe
EO: Pfeiffer, Parkin, Byford

The machine ran well today, and we accomplished essentially everything
in the run plan. Density scans from LOC to SOC regime were obtained at
1.1MA and 0.55MA, shot to shot and with dynamic single shot scans using
the NINJA to raise the density and to get GPI spectra. Locked mode
calibration shots were run at both current extremes. The last couple
of shots were dynamic density scans at 0.8MA, with GPI.    
Low densities were achieved without too much difficulty
without resorting to the USN cryopump option. The lowest density shots
were very non-thermal, with one synchrotron radiation case with nl04 below
2e19 at 550kA.  

Note that, due to a communication breakdown, the overnight ECDC was done in 
D2, and we only got one hour of Helium ECDC in the morning. This seems to
be completely satisfactory for getting to low density. 

I managed to screw up the load on shot#15, accidentally turning on seg4
which was zeroed out and had a start time of -3.5sec, along with the
intended seg1 and seg2. This resulted in a dud (duh!) with all the
power supplies looking very strange before 0.1sec. I should add a 
check to the build procedure to complain about simultaneous synchronous
segments. The next shot (#16) experienced the datalink failure that caused
the EF1's not to commutate. I would have blamed this on the preceding
bad load, but the switches did close at the right time, implying the
datalink fault came up during the pulse. Bill had been watching the 
camera view of the EF1 cabinet and would not have entered init if the 
fault light had been up at that time.

The TF cooling was rather slow today, partially because
we had to back off on the cooling several times due to the appearance 
of leaks when the vessel temperature went down as far as 24C. The 
signatures of the leak were exessive rga levels of Ar (mass 40) and
N2 (mass 28 and 14). The new big board display of rga levels was helpful
in alerting the PO and engineering team to these events. One source
was identified as a faulty heater on a blower unit under the machine,
but the leaks recurred later in the day, at a smaller level. There
were no fizzles due to these leaks.  

There were several bad runaway shots as a result of the low density 
operation, including at least one (#27) with a bright beam (which we have
attributed to synchrotron radiation) on the left side of the wide2 video
display. These did not trigger the dpcs_xjump shutdown only because the
high rates came up after the window from 0.1 to 0.5sec. If when we go in-
vessel in a week or two we find evidence of runaway damage, we should 
consider extending this window, probably with a higher threshold, to 
last through the shot. The reason for the preent window is that the
original threshold was such that it could be triggered by high-performance
DD neutron shots, or by intentional LHCD shots. However, the current 
threshold is 1e15/sec (neutron rate equivalent count rate), which is more
than the current record for neutron rates. Note that the gate window is
easily reset from the dpcs_xjump procedure screen, in the PARAMETERS 
structure, tagname GATE. 

Scorecard:
              Tests/No Power  0
              Duds            1 (Physop Error)
              Fizzles         2
              Plasmas        28
              ========       ==
              Shots          31

Session Leader Comments
Feb 16 2012 08:57:40:080AM1120216001John Ricelocked mode
no Sr data, rerun
Feb 16 2012 09:08:29:857AM1120216002John Ricelocked mode
decent Sr calibration shot
Feb 16 2012 09:26:13:733AM1120216003John Ricegood 1.1 MA LOC discharge
~ .7
no LBO
repeat
Feb 16 2012 09:42:41:310AM1120216003John Ricegood 1.1 MA LOC discharge
~ .3
one injection 0.8 s
Feb 16 2012 09:50:33:720AM1120216004John Ricegood 1.1 MA LOC discharge
~ .3
one injection 0.8 s
Feb 16 2012 09:50:42:537AM1120216005John Ricefiz
Feb 16 2012 10:07:50:143AM1120216006John Ricegood LOC 1.1 MA
ne ramp due to ninja, off for next shot
two good cold pulses, heat pinch/non local
Feb 16 2012 10:21:28:403AM1120216007John Ricegood LOC 1.1 MA
= 0.7
three good cold pulses, heat pinch/non local
Feb 16 2012 10:34:01:790AM1120216008John Ricegood LOC 1.1 MA
= 0.74
three good cold pulses, heat pinch/non local
Feb 16 2012 10:50:08:607AM1120216009John Ricegood LOC 1.1 MA
= 0.86
three good cold pulses, heat pinch/non local
Feb 16 2012 11:03:42:110AM1120216010John Ricegood LOC 1.1 MA
= 0.98
three good cold pulses, heat pinch/non local
Feb 16 2012 11:20:41:270AM1120216011John Ricegood SOC 1.1 MA, rotation reversed to counter current
= 1.2
three good cold pulses, heat pinch/non local
Feb 16 2012 11:42:07:533AM1120216012John Ricegood SOC 1.1 MA, rotation reversed to counter current
= 1.4
three good cold pulses, heat pinch/non local? a little ambiguous on some
Feb 16 2012 12:39:23:660PM1120216014John Ricegood SOC 1.1 MA, rotation reversed to counter current
= 1.75
three good cold pulses, looks like diffusive heat transport,
at slightly different density that the rotation reversal.
Feb 16 2012 01:21:29:613PM1120216017John Ricedensity ramp, reversal at 1.3 s
three good cold pulses,
Feb 16 2012 01:31:26:217PM1120216018John Ricelocked mode
Feb 16 2012 01:44:49:717PM1120216019John Rice0.59 MA, SOC, co-current rotation
= 0.79
injection too large, disrupted
Feb 16 2012 01:58:29:403PM1120216020John Rice0.55 MA, SOC, counter-current rotation
= 0.70
3 cold pulses, diffusive heat transport
Feb 16 2012 02:10:34:653PM1120216021John Rice0.55 MA, LOC, co-current rotation
= 0.47
3 cold pulses, 'heat pinch'
Feb 16 2012 02:24:39:600PM1120216022John Ricelocked mode

0.55 MA, LOC, co-current rotation
= 0.40
3 cold pulses, 'heat pinch', odd behavior
Feb 16 2012 02:42:34:997PM1120216023John Rice0.55 MA, ~LOC, ~co-current rotation
= 0.52
3 cold pulses, diffusive
Feb 16 2012 03:27:09:620PM1120216026John Rice0.55 MA, LOC, co-current rotation
= 0.45
3 cold pulses, non-diffusive?
Feb 16 2012 03:47:09:130PM1120216026John Rice0.55 MA, LOC, co-current rotation
= 0.28
3 cold pulses, non-thermal
Feb 16 2012 04:08:48:743PM1120216028John Rice0.55 MA
ramp, LOC to SOC with rotation reversal
3 cold pulses, non-thermal
Feb 16 2012 04:26:44:683PM1120216029John Ricelocked mode
Feb 16 2012 04:48:49:080PM1120216030John Rice0.8 MA
density ramp, rotation reversal at 1 s
three good cold pulses, 1st LOC, 2 and 3, SOC
Feb 16 2012 05:04:06:503PM1120216031John Rice0.8 MA
density ramp, rotation reversal at 1.08 s
6 good cold pulses, early LOC, late SOC?

Physics Operator Comments
Feb 16 2012 07:08:31:780AMSteve WolfeStarting setup for Thursday, Feb 16, 2012
Unable to access the logbook web interface on cmodws50.
It tries to go to alcserv1, and sits with a transferring data from alcserv1
message in the message pane. Got in ok through the old IDL interface.
Others (EO station, Bill Rowan on another workstation are seeing it ok.

Could have been because when I restored the firefox it brought up a dozen windows
and one was prompting for a password, after I had alreaduy entered one on a different
window. Blew it all away and restart firefox (after making this entry,)
Feb 16 2012 07:45:29:020AMSteve Wolfe
Ok, back into the web logbook interface in a fresh ff
Overnight ECDC was done in D2 (communication failure),
but got an hour of He ECDC in this morning. Should be ok,
we'll see how it goes for the first shots at low density. 

Beginning first shot setup per the run plan
Load from 1120215002, for the locked mode shot 
Locked mode shot is in seg3. 
Seg1 says "2012 non-cryopump startup", but it's got a 30msec puff
on pg4. Change that to 18msec. Check out the rest of the startup. I think
this is the startup that Bill used all day yesterday and Ian the day before,
with good success.
 Rcur offset=3500
 BR_0 offset=.001
 IC_EF4u = -1330 at [-.496,-.005] That seems very negative? maybe it helps.
 pg3 has a spike at -.020 to 100, dropping to 50 and a 
  30% maint level through 0.1sec; even the 30V may put in too much gas for
   the lowest density case, but leave it for now . 
In seg3:
 The inherited locked mode shot. 
 There is a wide pulse on H-bot piezo (pg5) that shouldn't be there. 
 Get rid of that, and the ancient leftover AMHD_FREQ. That output is
 obsolete, I should get rid of it in the hybrid dpcs_config. 
 The argon puff is 300msec at 60%. Don't know why, I guess that's what
  they asked for once upon a time; if it's been working don't fix it. 

For the rest of the run the plan says to load 1120106021 (seg2) and change
the current. May as well go ahead and import it to seg2 now. Will also
raise Btor to 5.6T for best FRCECE coverage, per SL.
Seg 2 changes (from 1120106021 import):
 Change Ip from 800 to 1.1MA
 Change TF_CURRENT from -150kA to -156kA
Load at 16-Feb-2012 07:45:13.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done


Feb 16 2012 09:00:15:977AM1120216001Steve Wolfe
Shot#1: locked mode attempt
plasma disrupts at 1.5sec, looks like a good locked mode case
clean breakdown fast current rise. Bz is negative, but I'm not
going to argue as long as it keeps running. 
Did not get hirex_sr data, so we'll need to repeat it. 

Next: repeat, with hirex_sr this time

Feb 16 2012 09:08:34:597AM1120216002Steve Wolfe
Shot#2: repeat locked mode attempt
plasma disrupts at 1.5sec, locked mode on demand
Cell access for PCI 
Hirex got data this time

Next: move on to first shot of main program

Feb 16 2012 09:24:40:070AM1120216003Steve Wolfe
Shot#3: move on to first shot of main program
Seg 3 off, seg 2 on. 
 this should be 1.1MA, nl04=3.5e19
 reduce pg3 puff in seg 1 to zero (from 30) after .05sec
 note ef4 is already at 2500, should be ok for 1.1MA
Load at 16-Feb-2012 09:12:52.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma to 1.6sec, density drops to .3 and then comes up to 0.5
need to play with gains. No lbo this time

Feb 16 2012 09:58:52:453AM1120216004Steve Wolfe
Shot#4: nl04 gain from PID [2,0,3] to [1,0,4]
slow rcur ramp in during rampdown
Load at 16-Feb-2012 09:32:11.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma with runaways disrupts at 1.08 sec
 runaways are saturated at .55 sec, very snowy on video
 xjump would have shut it down if it happened earlier.
Note ninja is coming in about 0.85, accounts for part of late rise 
 needs more gas early, less late. Adjust nl04 demand and gains

Feb 16 2012 09:51:45:853AM1120216005Steve Wolfe
Shot#5: Nl04 waveform demand to 5.5e19, dropping to 3.5 at .55sec
 nl94 p,i,d to [3,0,3] before 0.5, [1.5,0,3] after 0.5sec
Load at 16-Feb-2012 09:46:31.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: fizzle, bouncer? spike on Dalpha at 12msec
Next: Pg4 from 18 to 20ms

Feb 16 2012 10:08:14:963AM1120216006Steve Wolfe
Shot#6:Pg4 from 18 to 20ms
changes made on #5:
 Nl04 waveform demand to 5.5e19, dropping to 3.5 at .55sec
 nl94 p,i,d to [3,0,3] before 0.5, [1.5,0,3] after 0.5sec
Load at 16-Feb-2012 09:52:38.00

Result: plasma full length
startup fine, density looks ok until .9 when the ninja takes it up

Next: ninja off, maybe reduce field for better ped coverage?

Feb 16 2012 10:20:47:227AM1120216007Steve Wolfe
Shot#7: ninja off, maybe reduce field for better ped coverage?
Amanda suggests B=5.5, change tf_current to 153kA
The outer FRCECE are very non-thermal, but it looks like later in
the discharge there are two channels past the LCFS, so we drop the 
field to move in.

Result: plasma to 1.55sec, disruption just into rampdown. 
Bt to 5.5T as requested, density flattish at 3.5 to 4
Next: raise nebar to 0.9 (nl04 to .52)

Feb 16 2012 10:33:59:033AM1120216008Steve Wolfe
Shot#8: raise nebar to 0.9 (nl04 to .52)
OH2's railed in rampdown on shot7, probably causing the
disruption, so increase PLC limits to [-30,30]
Load at 16-Feb-2012 10:22:03.00
Result: plasma full length
density only 4.4 after higher early. Previous case may have had 
hollow Te, sawteeth started late; this one is normal, with overshooting
density before 300msec

Next: nl04 to .58, play with gains some more

Feb 16 2012 10:56:03:617AM1120216009Steve Wolfe
Shot#9: raise nebar to 1. (nl04 to .58)
Raise nl04 p gain to 3 for full shot
recalculate nl04 predictor, to be sure I pick up latest TCI cal
Load at 16-Feb-2012 10:38:15.00
Result: Disruption in rampdown 1.55sec, looks like a locked mode
density still a little on the low side, about .51 instead of .58
It's asking for more, but maybe not enough. Could increase P gain,
or add some I. 

Next: go for 1.1e20, nl04=.65e20

Feb 16 2012 11:04:15:740AM1120216010Steve Wolfe
Shot#10:  go for 1.1e20, nl04=.65e20
Raise P gain on NL04 from 3 to 6 at .6sec
Load at 16-Feb-2012 10:51:48.00

Result: plasma still disrupting in rampdown, 1.6sec
Density still 10% low, only .59e20. 
I'll have to add to the demand, ask for 1.3 to get 1.2 nebar



Feb 16 2012 11:22:19:230AM1120216011Steve Wolfe
Shot#11: Ask for nl04=.75 to get .7
Load at 16-Feb-2012 11:06:13.00
Getting an air leak, back off on the cooling 
leak coming down, argon still at 5.5e-8, m28 down to 3.7e-8 at Init
NINJA will puff
Result: plasma full length 
Got .7e20 before the ninja puff, then up to 0.8e20 by 1.5sec
rotation reversed but central ece still shows non-diff rise

Next: go for nebar=1.4e20 before ninja

Feb 16 2012 11:41:44:127AM1120216012Steve Wolfe
Shot#12: Ask for nl04=.87 to get .8; some I gain might help with this,
but this is just as easy. 
Load at 16-Feb-2012 11:24:05.00
leak seems to be gone for now
But the cooling is slow, because they backed down the pump
I guess I'd rather have it slow than leaking. 

Result: plasma full length, .82 before the ninja
still going up in the core, maybe with a drop before. 

Next: aim for nebar=1.6

Feb 16 2012 11:59:49:013AM1120216013Steve Wolfe
Shot#13: Ask for nl04=.96, dropping to .9 at 1.4 since NINJA is going anyway
Load at 16-Feb-2012 11:44:17.00
Argon up on the high e-8 scale again, backing down the cooling
argon coming down from 1e-7! m28 is only at 3e-8. Could bside-l have a 
through leak? Coming down now, should be ready

Result: plasma full length
nl04=9e19 pre-ninja, a little higher after
argon down on the 10 scale after the shot, vessel temp at 25
Core channels now going down.

Next: Going higher in density, nebar-> 1.8e20

Feb 16 2012 12:31:34:180PM1120216014Steve Wolfe
Shot#14: Ask for nl04=1.07, dropping to .9 at 1.4 
since NINJA is going anyway
decrease pg4 from 20 to 19msec, because Ip rise is getting a little slow
Load at 16-Feb-2012 12:05:26.00
Allow a cell access so vac can check that all the blowers are in
and see if anything is freezing up. We've got another leak
Leak closed at 20minutes into recool, vessel temp up to 28C
They found and replaced a dead heater blower under the machine. 
Time to go for a shot. 
INIT after 30min in recool

Result:plasma full length (almost, got to 1.8sec)
nl04=1.04e20, frcece dropping in core

Next: program nebar=1.0, let Ninja puff it up. 

Feb 16 2012 12:42:09:850PM1120216015Steve Wolfe
Shot#15: Ask for nl04=.64 flat, NINJA puff will raise it for scan
Load at 16-Feb-2012 12:34:20.00

Result: dud, all power supplies at low current!?




Feb 16 2012 12:53:59:167PM1120216015Steve Wolfe
Shot#15: Ask for nl04=.64 flat, NINJA puff will raise it for scan
Load at 16-Feb-2012 12:34:20.00

Result: dud, all power supplies at low current!?
DPCS commands look strange. 
physaout's look ok, mouts aren't asking for voltage?
looks like a timing proble, maybe
I see the problem. Somehow seg4 is also turned on,
and it has zeros everywhere and a start time of -3.5sec
Fumble fingers! This is a new pcs unguarded error to check for

Next: get the right segments loaded.
I'm having trouble hitting the wrong buttons!
Set seg4 off, with start at .1 anyway.
Take dpcs test shot 101 to be sure




Feb 16 2012 01:03:45:803PM1120216016Steve Wolfe
Shot#16: Ask for nl04=.64 flat, NINJA puff will raise it for scan
Load at 16-Feb-2012 12:55:40.0

Result:fizzle, EF1's did not commutate.
Not sure if this is fallout from the previous error or not.  
Checking on power supply fault




Feb 16 2012 01:16:55:123PM1120216017Steve Wolfe
Shot#17: Still asking for nl04=.64 flat, NINJA puff will raise it for scan
Fault on ef1 commutation reset in power room. Diagnosis is that datalink
fault must have come up during rampup, after switch closed.
Try again
Result: plasma full length, finally
Got the density ramp, got lbo

Next: locked mode shot (seg3)




Feb 16 2012 01:30:25:357PM1120216018Steve Wolfe
Shot#18:locked mode shot
Turn off seg2 turn on seg3
Load at 16-Feb-2012 13:20:32.00

Result: plasma disrupts at eof
Got the locked mode, 

Next: Ip to 550kA, nl04 to 0.2e20




Feb 16 2012 01:44:55:623PM1120216019Steve Wolfe
Shot#19: Seg 3 off, seg2 on
Ip to 550kA, nl04 to 0.2e20
IC_EF4u from 2500 to 2000
change title of seg2 to .55MA
In seg1, reduce pg4 from 19 to 18msec

Result: plasma disrupted at .83 following an injection at 0.8sec
Seems to be the first lbo time
nl04 was at 0.4 on it's way down when the injection hit.

Next: repeat with smaller lbo 




Feb 16 2012 02:00:11:047PM1120216020Steve Wolfe
Shot#20:repeat with smaller lbo
Decrease nl04 demand before .5sec to try to reduce nl04 
 Load at 16-Feb-2012 13:47:20.00

Result: plasma full length
nl04 only at 4e19, after dropping before the first lbo

Next: decrease argon from 200ms to 150ms




Feb 16 2012 02:11:02:983PM1120216021Steve Wolfe
Shot#21: decrease argon from 200ms to 150ms
decrease nl04 demand between .3 and .4sec
Load at 16-Feb-2012 14:03:59.00
We are now seeing an N2 leak (m28 to 6.7e-8 with no accompanying m40 or m32)
run it anyway
Result: plasma full length
nl04=2.7e19, some runaways after .8sec
cold to heat pulses on this one
Next: Drop nl04 even further (or try to)




Feb 16 2012 02:25:11:630PM1120216022Steve Wolfe
Shot#22: nl04 to 1e19 from .4sec on
Load at 16-Feb-2012 14:13:10.00
leak is getting worse, now seeing argon on 9 scale as well
argon down again, m28 at 9.7e-8 at INIT, may fizzle

Result: plasma full length, runaways 
nl04 down to 2.4e19, not sure I can get it any lower
MHD event on ece at .23sec, looks like a locked mode 
for the whole shot

Next: raise nebar to 0.5 (nl04=3e19)




Feb 16 2012 02:42:44:307PM1120216023Steve Wolfe
Shot#23:nl04 to 3e19
Load at 16-Feb-2012 14:26:18.00
TF scanner temp has been ratcheting up, waiting a little longer
m28 is still at 6.9e-8 at INIT at 16 minutes in recool

Result: plasma full length, still nonthermals
nl04 = 3e19, with some wiggles
First two look diffusive cold pulse, third one maybe a little rise in the
core

Next: leave programming, and let NINJA go on next shot





Feb 16 2012 02:59:12:757PM1120216024Steve Wolfe
Shot#24:nl04 to 3e19, but NINJA will fire on this one
No pcs changes

Result: early disruption, something came in at 0.3sec
May have been hit by that mhd thrash, seems to be going vertically
before the injection. 

Next:I'm going to give it a little more early gas





Feb 16 2012 03:10:23:670PM1120216025Steve Wolfe
Shot#25: raise nl04 at .4 sec to 4e19 (from 3e19), leaving 3e19 in flattop
Load at 16-Feb-2012 15:00:41.00
Result: plasma full length, got lbo's
got the ninja ramp
all three injections look like diffusive cold pulses

Next: Back to the lower density case and try it again




Feb 16 2012 03:28:15:703PM1120216026Steve Wolfe
Shot#26:reload from 22, which has programming for 1e19 and got down to 2.4
Decrease the point at .275sec from 5 to 3e19
Load at 16-Feb-2012 15:13:49.00
Leak is opening up again, back pump down to 3psi again
Result:plasma full length, runaways up but not terrible
nl04 2.8e19, down to 2e19 before first lbo
No D2 gas puff in seg2

Next: repeat, see if density comes down a little more




Feb 16 2012 03:48:48:313PM1120216027Steve Wolfe
Shot#27:repeat, see if density comes down a little more

Result: plasma disrupts near eof, lots of runaways, saturating neuts/hards
nl04 down to 1.7e19 until last lbo, then it rises to 4e19
Phaser on kill

Next: ask for a little more density, then have ninja puff




Feb 16 2012 04:11:05:400PM1120216028Steve Wolfe
Shot#28: increase nl04 to 2e19, NINJA puff should come in at .9sec
Load at 16-Feb-2012 15:51:51.00

Result: plasma full length, nl04 starts at 1.9e19, saturating runaways,
then ninja puffs up to 5e19 and runaways come down. 
This ought to give them what they want, if the low density non-thermal 
phase can be interpreted. There's a locked mode until at least 1.1sec

Next: ?




Feb 16 2012 04:26:26:403PM1120216029Steve Wolfe
Shot#29: locked mode shot (seg3 on seg2 off)
Load at 16-Feb-2012 16:15:58.00
plasma to eof, got locked mode

Next: 800kA, nebar~0.7e20 ramping to 0.9 with ninja




Feb 16 2012 04:47:44:900PM1120216030Steve Wolfe
Shot#30: 800kA, nebar~0.7e20 (nl04=.42e20) ramping to 0.9 with ninja
leave ic_ef4u at 2000 for 800kA
Seg 3 off, Seg 2 on
Load at 16-Feb-2012 16:27:34.00

Result: plasma full length, some runaways
Got the density ramp, got the lbo's, looks like cold pulses for all 3

Next: repeat with 200ms of argon 




Feb 16 2012 05:03:22:233PM1120216031Steve Wolfe
Shot#31:repeat with 200ms of argon 
Load at 16-Feb-2012 16:48:43.00

Result: plasma full length. LBO gave six injections.
Ramp looks good. SL is happy. 

End of Run




Engineering Operator Comments
ShotTimeTypeStatusComment
108:51:40:467AMPlasmaOk
209:04:37:353AMPlasmaOk
309:19:27:603AMPlasmaOk
409:33:02:437AMPlasmaOk
509:47:23:260AMPlasmaOk
610:00:44:390AMPlasmaOk
710:16:03:610AMPlasmaOk
810:28:43:667AMPlasmaOk
910:42:35:463AMPlasmaOk
1010:58:00:440AMPlasmaOk
1111:15:16:883AMPlasmaOk
1211:36:01:763AMPlasmaOk
1311:52:42:497AMPlasmaOk
1412:25:39:617PMPlasmaOk
1512:38:17:087PMPlasmaBadmultiple power supply irregularities
1612:57:23:857PMPlasmaBadEF1UL did not commutate
1701:13:17:540PMPlasmaOk
1801:26:49:337PMPlasmaOk
1901:39:44:287PMPlasmaOk
2001:52:28:630PMPlasmaOk
2102:05:07:000PMPlasmaOk
2202:17:46:293PMPlasmaOk
2302:36:29:973PMPlasmaOk
2402:51:15:787PMPlasmaOk
2503:04:13:660PMPlasmaOk
2603:21:17:610PMPlasmaOk
2703:41:49:813PMPlasmaOk
2804:04:17:130PMPlasmaOk
2904:22:41:210PMPlasmaOk
3004:41:23:840PMPlasmaOk
3104:58:08:280PMPlasmaOk

System Availability
Feb 16 2012 08:51:29:080AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 02 2008 11:03AM (sears)Joe SnipesActive MHD Antennagolfit
BESyesBES system is onlineNov 22 2011 02:21PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
BolometersyesMidplane and LEDGE-AX diodes functioning properly. Midplane bolometers working and calibrated. LEDGE/DIV bolometers working, but toaster calibration not yet complete.Jan 23 2012 12:02PM (mlreinke)Matt ReinkeBolometershutch,mlreinke
BoronizationnoBottle Removed. System has been tested and will be ready once bottle is installedJan 09 2012 06:32AM (dekow)Jim IrbyBoronizationdekow,irby
CECEno Jan 06 2012 03:48PM Anne WhiteCorrelation ECEwhitea
CNPAyesMultiple channel CNPA available, no safety risk for in-vessel accessApr 14 2011 12:01PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper DivertoryesOperational. He level meter not working on 500L dewar. Frank will take manual readings.Jan 11 2012 11:46AM (labombard)Brian LaBombardUpper Divertor Cryopumpdekow,irby,labombard
CXRSyescore-CXRS system is onlineNov 22 2011 02:21PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
CXRS edgeyesMichael CHurchill has primary responsibility at the momentApr 19 2011 11:44AM (blip)Bruce LipshultzMeasurement of CXR light in the pedestal region at both the high- and low-field sidesblip,rmchurch
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 01 2009 09:45AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsanosystem is is installed and aligned, but not functional (appears to be a broken cable)Dec 05 2011 02:41PM (marmar)Earl MarmarVisible Bremsstrahlung Imagingmarmar
Disruption Mitigationnogas jet valve disabled on 2011/04/13Apr 13 2011 02:04PM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 06 2007 10:50AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 06 2007 10:51AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DMBolo AXUV diodesyesDiodes are taking usable data. Not all post-processing code is working yet.Feb 01 2012 01:24PM (golynyk)Geoff OlynykSet of six AXUV diodes in a toroidal array of midplane wall boxes.golynyk,granetz,mlreinke,whyte
DNByes Dec 01 2011 11:46AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,mochung
ECDCyesOperational as of 11/19/11Nov 22 2011 03:01PM (irby)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEnoPower off to RF and IF sections- Power on to DAApr 11 2011 02:54PM (phillips)Perry PhillipsHeterodyne ECE-32 channelsbespam,liao,phillips,rowan,whitea
FTCIno Jan 06 2012 04:36PM Jim IrbyFast two-color interferometerirby
G-Side Ratiomaticyes Dec 02 2011 12:24PM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoPower supply unplugged and redtagged, HV cables removedApr 14 2011 08:03AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesUsing new preamps.Nov 30 2011 07:51AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPC2yesDewar cold. Nov 21 2011 09:55AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 01 2009 09:45AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyessystem is functional and taking dataDec 05 2011 02:42PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Jan 09 2012 06:32AM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SryesInstalled and aligned. Will be available for Ti/Vr profiles after focusing tests and locked modes are taken.Dec 06 2011 08:21AM (ypodpaly)John RiceHigh Resolution X-Raycgao,ldelgado,rice,ypodpaly
HXRyes32 Channels operational,, no safety risk for in-vessel accessApr 14 2011 12:05PM (parker)Ron ParkerHard X-Ray Arrayfaust,parker,schmidt
ICRF D-AntennanosecuredApr 14 2011 08:55AM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-AntennanosecuredApr 14 2011 08:55AM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-AntennanosecuredApr 14 2011 08:56AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Impurity SpectroscopyyesBeing upgraded with better optics and new spectrographs. Dan Miller has primary responsibility.Apr 19 2011 11:46AM (blip)Bruce LipshultzMeasurement of recycling light and impurity source rates at multiple surfaces around the tokamakblip,miller
Laser Blow-OffyesOperational and testedJan 06 2012 03:50PM (g)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoLH HV Breaker Opened and Tagged, TPS Upgrade UnderwayNov 10 2011 03:51PM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
Lower Hybrid ReflectometernooffApr 15 2011 08:24AM (dominguez)Arturo DominguezLower Hybrid Reflectometerdominguez,marmar,parker,sgbaek
LoWEUSyesLoWEUS viewing the 10-30 nm region, spectral brightness vs. lambda and time are being stored in tree.Jan 23 2012 12:03PM (mlreinke)Matthew L. Reinke Long Wavelength Extreme Ultraviolet Spectrometermarkchil,mlreinke
LPInoBeam line removedMay 30 2008 02:09PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane Lyman-a and LEDGE-LY working normally. New B-PORT Lyman (BPLY) still being debugged.Jan 23 2012 12:04PM (mlreinke)Matt ReinkeLyman alpha camerasfaustian,labombard,mlreinke
Magneticsyes Dec 01 2011 11:51AM (g)Robert GranetzBp coils and flux loops for equilibrium controlgranetz,wolfe
McPhersonno**vacuum system problem*** McPherson viewing the 10-14 nm region for molybdenum monitoring. It's days are numbered as LoWEUS has demonstrated superiority.Jan 31 2012 08:15AM (mlreinke)Jim TerryVUV Spectrometermarkchil,mlreinke,terry
MichelsonyesFront end at 4.5e-8 T. Reduced speed for initial operation.Nov 30 2011 07:51AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyes Dec 02 2011 12:27PM (toland)Brian LaBombardBaratron pressure gaugeslabombard,toland
MLPnoSystem is in edge lab. Version 2 drivers ready to test. Needs a student to help work on it.Jul 14 2009 09:20PM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEno1/3/2011: push-pull mechanism broken. MSE inoperativeJan 03 2012 11:47AM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesHigh voltage is on. We're ready for plasma.Nov 21 2011 12:58PM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesAll detectors Powered On --- Waiting for neutrons for calibrationNov 22 2011 01:05PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAyesC-bottom and new F-bottom system ready.Dec 02 2011 12:28PM (toland)Brian LaBombardNINJA gas pufflabombard,terry,toland
PCIyesOperational.Nov 30 2011 12:45PM (ntsujii)Miklos PorkolabPhase Contrast Imagingemd,ennever,ntsujii,porkolab
Penning GaugesyesOperational. High voltage comes on during INIT and off at RECOOL.Dec 09 2011 09:48AM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 01 2009 09:46AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
Polarimeteryes3 chords operational but with high noise levelJan 06 2012 04:22PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Jan 09 2012 06:33AM (dekow)Gary Dekowfeeds all the other suppliescochran,dekow,dterry,irby
Power - PEIyes Jan 09 2012 06:33AM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Jan 09 2012 06:33AM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Jan 09 2012 06:33AM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational, except for probe #1 (open circuit) and probe #16 (not installed).Dec 09 2011 09:50AM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational, except for bottom-D probe (open circuit).Dec 09 2011 09:52AM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesF-divertor ok. J-divertor ok, except for JDIV_06 which is shorted out.Dec 09 2011 09:54AM (labombard)Brian LaBombardOuter Lower Divertor Probe Array (F and J)labombard
Probe Array - UDIVyesOperational except for probes #4, 5 and 13 (open)Dec 09 2011 09:56AM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesAs of 1120105xxx, all channels are connectedJan 05 2012 09:14AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesIon Sensitive Probe head installed. Testing in piggy-back mode.Dec 20 2011 12:33PM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.Dec 09 2011 09:57AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPyesA-port WASP is operational. K-port WASP is dead (all probes melted together).Dec 09 2011 09:58AM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
Shoelace AntennayesFixed frequency operation available (100kHz) at moderate power (< 0.5kW). Otherwise in receiver mode.Jan 11 2012 11:50AM (labombard)Brian LaBombardHigh-k active MHD antenna, for QCM, WCM studiesgolfit,labombard
SOL reflectometeryesc-port waveguides operational, h-port waveguides are not.Nov 29 2011 12:04PM (cornwall)Cornwall LauSOL reflectometercornwall,wukitch,ylin
SparkeryesNew Type II sparker replaced Type I on 11/17/2011Nov 23 2011 08:53AM (irby)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationnoSSS is up to air, no safety issuesApr 14 2011 12:06PM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesTCI Operational. Density feedback operational.Nov 10 2011 11:47AM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CoreyesOperating with two 50Hz lasers, precise density calibration still required.Feb 03 2012 04:04AM (jwhughes)Jerry HughesCore Thomson scatteringjrwalk,jwhughes,yma
TS - EdgeyesSystem taking data. Requires calibration.Feb 03 2012 04:05AM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjrwalk,jwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesXEUS viewing the 1-6 nm region, spectral brightness vs. lambda and time are being stored in tree.Jan 23 2012 12:13PM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermarkchil,mlreinke
XTOMOyesARRAY1->4 working normally, ARRAY5 (new core view) working but spatial calibration issues not yet resolvedJan 23 2012 12:13PM (mlreinke)Robert GranetzX-Ray Tomographyfaustian,granetz,mlreinke