Alcator C-Mod Run 1120626 Information

Back to runs

Miniproposals
Miniproposal:696
Date Filed: 5/4/2012
Title:Continued investigations of dilution effects on turbulence and transport in low density ohmic plasma
First Author:Paul Ennever
Session Leader:Paul Ennever (shots 1-17)
Miniproposal:703
Date Filed: 5/23/2012
Title:Commisioning of the correlation electron cyclotron emission diagnostic
First Author:Choongki Sung
Session Leader:Choongki Sung (shots 18-32)

Operators
Session leader(s):Paul Ennever,Choongki Sung
Physics operator(s):Earl Marmar
Engineering operator(s):Bill Cochran,Ed Fitzgerald

Engineering Operator Run Comment
MP703 "Commissioning of the Correlation Electron Cyclotron Emission Diag

Session Leader Plans
Entered: Jun 25 2012 11:23:41:003AM
Author: Choongki Sung
MP703 "Commissioning of the Correlation Electron Cyclotron Emission Diagnostic"

The purpose of this run is to measure electron temperature fluctuations using CECE diagnostic. Total 12 shots are planned, B field will be scanned from 5.3T to 5.6T with 0.1T interval shot by shot while maintaining other plasma conditions.

All parts
===============
Working gas : D2
Equilibrium : LSN
nl04=0.5

Detailed Sequence
==================

Part 1 : ICRF heated L-mode plasma (Ip=0.6MA, 0.5MW ICRF (t:0.5-1.5s)), B field will be scanned from 5.3T to 5.6T. (4 shots, i.e., 5.3, 5.4, 5.5 and 5.6T)

Part 2 : Ohmic SOC plasma (Ip=0.6MA), B field will be scanned from 5.3T to 5.6T. (4 shots, i.e., 5.3, 5.4, 5.5 and 5.6T)

Part 3 : Ohmic LOC plasma (Ip=1.1MA), B field will be scanned from 5.3T to 5.6T. (4 shots, i.e., 5.3, 5.4, 5.5 and 5.6T)

If time remains:
Locked mode shot for Hirex rotation calibration based on 1120615009.

Required diagnostics
======================
Magnetics,GPC,FRCECE, core and edge Thomson, TCI, Hirex, PCI, O-mode reflectometer
Entered: Jun 25 2012 05:28:51:153PM
Author: Paul Ennever
MP696 "Continued investigations of dilution effects on turbulence and transport in low density ohmic plasma"

The purpose of this run is to repeat discharges from 1120615XXX with the PCI mask in place to determine the mode propagation direction. Shots will be repeated from the highest density to the lowest and preference given to the densities near the LOC-SOC transition.

Helium ECDC the night before is requested

All Parts
==============
Working Gas: D2
Equilibrium: based on 1120615029 (USN, 5.4T, 1.0 MA)
NINJA: 10 PSI He @ 1.35s for GPI
H-Bot: 1 psi Ar puff at 0.4s for 75ms with 100V for HIREX-Sr, will increase pressure to 2 psi when done with N2 seeding and change voltage and time
B-Lower: 15 psi N2, voltages variable
Cryopump: On when seeding, off when not seeding
DNB: On for boron CXRS


Detailed Sequence
==================

Part 0: HIREXSR locked mode calibration
Based on 1120615009 (most recent successful locked mode calibration)
Wait for successful shot before doing this

Part 1: Repeat Shot 1120615006 (nl04=0.55) with mask 9 degrees CCW (upper portion of plasma)

Part 2: Repeat Shot 1120615005 (nl04=0.65, but correct Bt) with mask 9 degrees CCW (upper portion of plasma)

Part 3: Repeat Shot 1120615029 (nl04=0.73) with mask 9 degrees CCW (upper portion of plasma)

Part 4: Repeat Shot 1120615028 (nl04=0.82) with mask 9 degrees CCW (upper portion of plasma)

Nitrogen Seeding Begins:

Part 5: Repeat Shot 1120615027 (nl04=0.80, with 70V on PG1) with mask 9 degrees CCW (upper portion of plasma)

Part 6: Repeat Shot 1120615026 (nl04=0.80, with 60V on PG1) with mask 9 degrees CCW (upper portion of plasma)

Part 7: Repeat Shot 1120615025 (nl04=0.75, with 55V on PG1) with mask 9 degrees CCW (upper portion of plasma)

Part 8: Repeat Shot 1120615024 (nl04=0.65, with 45V on PG1) with mask 9 degrees CCW (upper portion of plasma)

Part 9: Repeat Shot 1120615022 (nl04=0.55, with 45V on PG1) with mask 9 degrees CCW (upper portion of plasma)

Part 10: Switch mask to 9 degrees CW and repeat parts 5 & 6

Contingencies:

repeat part 7 with mask in CW position

repeat parts 1 & 2 with mask in CW position

After run is finished, take out PCI mask for latter half of run day.

Physics Operators Plans
Entered: Jun 26 2012 08:55:34:740AM
Author: Earl Marmar
MP696 "Continued investigations of dilution effects on turbulence and transport in low density ohmic plasma" (first half)

MP703 "Commissioning of the Correlation Electron Cyclotron Emission Diagnostic" (second half)

SL: P. Ennever (first half), C. Sung (second half)
PO: E. Marmar

-----------------
Engineering Setup
-----------------

Run begins at 09:00 and ends at 17:00

Power systems as on: 1120615029 (USN, 5.4T, 1.1MA)

Acoil: +Dtop -Dbot -Jtop +Jbot (standard) Hybrid Enabled

Gas setup:

Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 15 psi N2 Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3)
fill NINJA with 10 psi He DISABLED
fill H-bot lower with 1 psi Ar Hybrid DISABLED (PG5)

Enable gate-valves and shutters: ECE, VUV, HiREX Sr, Xeus/LoWEUS
Leave z-bolo shutter as is (should be open)

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): no
Overnight ECDC (yes/no): yes (helium)
ICRF(yes/no): yes (second half of the run)
LH(yes/no): no
Cryopump (yes/no): yes
DNB (yes/no): yes

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters
------------------------------
Gas: HELIUM
sweep: 44/103/45 cm
scan: 20/120 s
Pressure: 5.0e-5 Torr

Session Leader Summaries
Entered: Jun 26 2012 01:57:25:797PM
Author: Paul Ennever
We managed to get the following shots:

With mask set to 9 Degrees CCW (looking at BOTTOM of plasma, previous notes were incorrect)
Shot |Request | Trange | nl04 | PG1
====================================================
05 |0.55,us |[0.8,1.1] | 0.55 | 0 |
--------------------------------------------------------------------------
06 |0.65,us |[0.8,1.1] | 0.65 | 0 |
--------------------------------------------------------------------------
07 |0.75,us |[0.8,1.1] | 0.73 | 0 |
--------------------------------------------------------------------------
08 |0.82,us |[0.8,1.1] | 0.83 | 0 |
--------------------------------------------------------------------------
11 |0.80,sd |[1.0,1.3] | 0.82 | 70 |
--------------------------------------------------------------------------
12 |0.80,sd |[1.0,1.3] | 0.84 | 60 |
--------------------------------------------------------------------------
14 |0.75,sd |[1.0,1.3] | 0.76 | 55 |
---------------------------------------------------------------------

With mask set to 9 Degrees CW (Looking at TOP of plasma)
Shot |Request | Trange | nl04 | PG1
====================================================
15 |0.75,sd |[1.0,1.3] | 0.76 | 55 |
---------------------------------------------------------------------
17 |0.80,sd |[0.9,1.0] | 0.84 | 70 | Poloidal Detachment after 1s?
---------------------------------------------------------------------

Fizzles were a problem for many shots, but we managed to get a good data set regardless
Entered: Jun 26 2012 01:58:42:397PM
Author: Paul Ennever
We managed to get the following shots:

With mask set to 9 Degrees CCW (looking at BOTTOM of plasma, previous notes were incorrect)
Shot |Request | Trange | nl04 | PG1
====================================================
05 |0.55,us |[0.8,1.1] | 0.55 | 0 |
--------------------------------------------------------------------------
06 |0.65,us |[0.8,1.1] | 0.65 | 0 |
--------------------------------------------------------------------------
07 |0.75,us |[0.8,1.1] | 0.73 | 0 |
--------------------------------------------------------------------------
08 |0.82,us |[0.8,1.1] | 0.83 | 0 |
--------------------------------------------------------------------------
11 |0.80,sd |[1.0,1.3] | 0.82 | 70 |
--------------------------------------------------------------------------
12 |0.80,sd |[1.0,1.3] | 0.84 | 60 |
--------------------------------------------------------------------------
14 |0.75,sd |[1.0,1.3] | 0.76 | 55 |
---------------------------------------------------------------------

With mask set to 9 Degrees CW (Looking at TOP of plasma)
Shot |Request | Trange | nl04 | PG1
====================================================
15 |0.75,sd |[1.0,1.3] | 0.76 | 55 |
---------------------------------------------------------------------
17 |0.80,sd |[0.9,1.0] | 0.84 | 70 | Poloidal Detachment after 1s?
---------------------------------------------------------------------

Fizzles were a problem for many shots, but we managed to get a good data set regardless.
Entered: Jun 26 2012 06:07:49:227PM
Author: Choongki Sung
We managed to get the following shots:

shot / nl04 / Ip [MA] / Bt [T] / confinement region / observation (core, rho<0.9), need to record

19 / 0.42 / 0.8 / 5.44/ LOC (near the boundary) / fluctuation looks weak (ch1 & 2), 100MHz BW filters are used for ch1 and 2.
23 / 0.5 / 0.9 / 5.44 / LOC (definitely) / We observe fluctuations (ch1 & 2), 200MHz filters are used for ch1 and 2.
24 / 0.5 / 0.9 / 5.36 / LOC / Fluctuations observed (ch3 & 4, strong, ch 1 & 2 weak)
25 / 0.5 / 0.9 / 5.55 / LOC / Fluctuations observed
27 / 0.7 / 0.9 / 5.44 / rotation reversal shot
28 / 0.8 / 0.9 / 5.44 / SOC / No or very weak fluctuations (ch1 & 2)
29 / 0.4 / 0.8 / 5.44 / locked mode / good locked mode
31 / 0.5 / 0.9 / 5.44 / L-mode (0.5MW ICRF) / Fluctuations are similar to the shot 23
32 / 0.5 / 0.9 / 5.44 / L-mode (1.0MW ICRF) / Fluctuation amplitude (absolute) increased, fluctuation width is similar to shot 23 and 31.

Physics Operator Summaries
Entered: Jun 26 2012 05:17:51:657PM
Author: Earl Marmar
The machine ran pretty well today. Intermittent fizzles occurred; tweaks to fields and fill may have helped.

The first half of the day was run with the cryopump (through shot 17); for the rest of the day, the cryopump was not cooled.

There was one no-TF dud.

Summary:
Shot,Duration(s),Ipmax(MA),Result Shot,Duration(s),Ipmax,Result
| 01 1.666 1.042 Plasma | 02 0.000 0.038 Fizzle |
| 03 0.000 0.035 Fizzle | 04 0.000 0.036 Fizzle |
| 05 1.926 1.040 Plasma | 06 1.925 1.037 Plasma |
| 07 1.923 1.037 Plasma | 08 1.216 1.072 Plasma |
| 09 1.966 0.833 Plasma | 10 1.583 0.829 Plasma |
| 11 1.925 1.037 Plasma | 12 1.936 1.036 Plasma |
| 13 0.520 1.027 Plasma | 14 1.940 1.036 Plasma |
| 15 1.936 1.037 Plasma | 16 0.000 0.045 Fizzle |
| 17 1.058 1.111 Plasma | 18 0.000 0.043 Fizzle |
| 19 1.922 0.814 Plasma | 20 1.317 1.029 Plasma |
| 21 0.947 0.986 Plasma | 22 0.000 0.041 Fizzle |
| 23 1.898 0.911 Plasma | 24 1.860 0.911 Plasma |
| 25 1.862 0.914 Plasma | 26 0.000 0.042 Dud |
| 27 1.840 0.913 Plasma | 28 1.866 0.913 Plasma |
| 29 1.808 0.827 Plasma | 30 0.000 0.039 Fizzle |
| 31 1.658 0.914 Plasma | 32 1.952 0.915 Plasma |

Date 1120626: 32 shot cycles. 24 plasmas. 7 fizzles. 1 dud. 0 System Error.
(Plasma = Ip gt 60.0 kA Dud = H_alpha lt 0.10 V)
Total plasma duration: 40.45 s (exceeding -104 kA)

Session Leader Comments
Jun 26 2012 09:11:46:627AM1120626001Paul EnneverPCI Set to 9 degrees CCW.

Start with Part 1 of session leader plan:

Repeat Shot 1120615006 (nl04=0.55) with mask 9 degrees CCW (upper portion of plasma)

Result: No PCI and no H-Bottom

Density and equilibrium are good

Next: Repeat with PCI and Argon


Jun 26 2012 09:23:22:417AM1120626002Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615006 (nl04=0.55) with mask 9 degrees CCW (upper portion of plasma)

Result: Fizzle

Next: Repeat

Jun 26 2012 09:42:56:197AM1120626003Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615006 (nl04=0.55) with mask 9 degrees CCW (upper portion of plasma)

Result: Fizzle

Next: Repeat

Jun 26 2012 09:52:37:510AM1120626004Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615006 (nl04=0.55) with mask 9 degrees CCW (upper portion of plasma)

Result: Fizzle

Next: Repeat

Jun 26 2012 10:09:53:030AM1120626005Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615006 (nl04=0.55) with mask 9 degrees CCW (upper portion of plasma)

Result: Good repeat shot

Next: Move on to Part 2: Repeat shot 1120615005 (nl04=0.65, but same Bt as shot 5 from today)

Jun 26 2012 10:24:41:247AM1120626006Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615005 (nl04=0.65) with mask 9 degrees CCW (upper portion of plasma)

Result: Good repeat shot

Next: Move on to Part 3: Repeat shot 1120615029 (nl04=0.73)

Jun 26 2012 11:11:20:683AM1120626007Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615029 (nl04=0.73) with mask 9 degrees CCW (upper portion of plasma)

Result: Good repeat shot

Next: Move on to Part 4: Repeat shot 1120615028 (nl04=0.82)

Jun 26 2012 10:58:15:273AM1120626008Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615028 (nl04=0.82) with mask 9 degrees CCW (upper portion of plasma)

Result: Disrupted at 1.2 seconds, but ran long enough to be useful

Next: Move on to Part 0: Locked Mode

Jun 26 2012 11:20:09:037AM1120626009Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615009: Locked Mode

Result: Locked mode, but no argon

Next: Repeat

Jun 26 2012 11:30:58:013AM1120626010Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615009: Locked Mode

Result: Good Locked mode, almost dies at ~1 second

Next: Move on to Part 5: Repeat Shot 1120615027 (nl04=0.8, 70V on PG1)

Jun 26 2012 11:48:57:540AM1120626011Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615026: nl04 = 0.8, 60V on PG1

Result: Great repeat: same ne, same prad, same reversal

Next: Move on to Part 6: Repeat Shot 1120615026 (nl04=0.8, 60V on PG1)

Jun 26 2012 12:12:38:543PM1120626012Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615026: nl04 = 0.8, 60V on PG1

Result: Great repeat: same ne, same prad, same reversal

Next: Move on to Part 7: Repeat Shot 1120615025 (nl04=0.75, 55V on PG1)

Jun 26 2012 12:32:08:363PM1120626014Paul EnneverPCI Set to 9 degrees CCW.
Request:

Repeat Shot 1120615025: nl04 = 0.75, 55V on PG1

Result: Shot ran and was good repeat of reference shot

Next: Repeat but switch mask to 9 degrees CW
Jun 26 2012 12:54:11:933PM1120626015Paul EnneverPCI Set to 9 degrees CW.
Request:

Repeat Shot 1120615025: nl04 = 0.75, 55V on PG1

Result: Shot ran

Next: Repeat shot 11 from today with mask at 9 degrees CW
Jun 26 2012 01:02:14:640PM1120626016Paul EnneverPCI Set to 9 degrees CW.
Request:

Repeat Shot 11: nl04 = 0.8, 70V on PG1

Result: Fizzle

Next: Repeat
Jun 26 2012 01:43:01:823PM1120626017Paul EnneverPCI Set to 9 degrees CW.
Request:

Repeat Shot 11: nl04 = 0.8, 70V on PG1

Result: Plasma Disrupted a little after 1.0s, but there was enough flat top to get good data

Next: Finished
Jun 26 2012 01:32:44:927PM1120626018Choongki SungThe shot plan is changed.
Part 3 will be do first from shot 18, and then part 2 and part 1 will be done.
The reference shot for part 3 will be 1120607008.

Jun 26 2012 01:39:14:300PM1120626018Choongki Sungrequest : nl04 ~ 0.42, Bt=5.4T and Ip=0.8MA LOC ohmic plasma

result : fizzle

Next : repeat

Jun 26 2012 01:58:43:157PM1120626019Choongki Sungrequest : nl04 ~ 0.42, Bt=5.4T and Ip=0.8MA LOC ohmic plasma

result : LOC ohmic plasma, but slightly high density, near the boundary between LOC and SOC. Fluctuations between ch1 and ch2 looks weak.

request : increase plasma current 1.0 MA

Jun 26 2012 02:16:58:727PM1120626020Choongki Sungrequest : nl04 ~ 0.42, Bt=5.4T and Ip=1.0MA LOC ohmic plasma

result : disrupted at on flattop (might be due to locked mode ?)
request : reduce the plasma current to 0.9MA to prevent locked mode
Jun 26 2012 02:26:47:350PM1120626021Choongki Sungrequest : nl04 ~ 0.42, Bt=5.4T and Ip=0.9MA LOC ohmic plasma

result : disrupted due to locked mode again

request : increase density(nl04) to 0.5e20 (m^-2)
Jun 26 2012 02:54:44:587PM1120626023Choongki Sungrequest : nl04 ~ 0.5, Bt=5.4T and Ip=0.9MA LOC ohmic plasma

result : good steady shot. Fluctuations are observed.

next : B field will be changed to 5.36T

Jun 26 2012 03:07:42:727PM1120626024Choongki Sungrequest : nl04 ~ 0.5, Bt=5.36T and Ip=0.9MA LOC ohmic plasma

result : Good shot, fluctuations were weak between ch1 &2, but strong between ch3 & 4

next : Do one more LOC shot Bt=5.55T

Jun 26 2012 03:20:41:107PM1120626025Choongki Sungrequest : nl04 ~ 0.5, Bt=5.55T and Ip=0.9MA LOC ohmic plasma

result : Steady shot, stronger fluctuations from ch1 and 2 as expected.

next : Move to SOC region. Increase density, nl04 to 0.7

Jun 26 2012 03:37:57:363PM1120626026Choongki Sungrequest : Start part 2. nl04 ~ 0.7, Bt=5.55T and Ip=0.9MA SOC ohmic plasma

result : no TF

next : change B field to the one in shot 23


Jun 26 2012 03:55:16:033PM1120626027Choongki Sungrequest : nl04 ~ 0.7, Bt=5.44T and Ip=0.9MA SOC ohmic plasma

result : rotatin reversal shot.

next : Increase nl04 from 0.7 to 0.8


Jun 26 2012 04:12:56:127PM1120626028Choongki Sungrequest : nl04 ~ 0.8, Bt=5.44T and Ip=0.9MA SOC ohmic plasma

result : Good SOC plasma. No fluctuations from ch1 and 2

next : Locked mode for Hirex calibration


Jun 26 2012 04:22:04:910PM1120626029Choongki Sungrequest : Locked mode (reference shot : 1120626010)

result : Good locked mode

next : Repeat shot 23 with 1MW ICRF power




Jun 26 2012 04:37:34:987PM1120626030Choongki Sungrequest : nl04 ~ 0.5, Bt=5.4T and Ip=0.9MA, 1MW ICRF power

result : fizzle

next : Try again !

Jun 26 2012 04:56:20:720PM1120626031Choongki Sungrequest : nl04 ~ 0.5, Bt=5.4T and Ip=0.9MA, 1MW ICRF power

result : 0.5MW ICRF power plasma

next : Try 1MW ICRF power

Jun 26 2012 05:26:56:170PM1120626032Choongki Sungrequest : nl04 ~ 0.5, Bt=5.4T and Ip=0.9MA, 1MW ICRF power

result : 1MW ICRF plasma, fluctuations becomes bigger than shot 23, 31

next : end of run


Physics Operator Comments
Jun 26 2012 09:15:15:587AM1120626001Earl Marmarload from 1120615006 (cryopump startup)
TF current to -150kA in segment 2
plasma, small bounce in startup
disrupt in rampdown (700 kA)
Jun 26 2012 09:26:31:030AM1120626002Earl MarmarTF PLC start to -1.1 s (from -1.0) for polarimetry
enable argon (H-bottom)

fizzle, almost no current rise
B_R may be slightly negative

Jun 26 2012 09:45:30:863AM1120626003Earl MarmarB_R offset to +0.0015 (from +0.001)
Load at 26-Jun-2012 09:25:33.00

fizzle
Jun 26 2012 10:02:51:497AM1120626004Earl Marmarprefill puff to 45 ms (from 49)
Load at 26-Jun-2012 09:44:52.00

fizzle
a bit of current rise this time
very early hards (with little current)
Jun 26 2012 10:09:14:903AM1120626005Earl Marmarreduce PG3 puff around t=0
Load at 26-Jun-2012 09:54:43.00

plasma, full length
startup looks ok
Jun 26 2012 10:31:30:840AM1120626006Earl Marmarincrease argon puff (PG5) to 60 ms (from 50)
nl_04 target to 7.04e19
Load at 26-Jun-2012 10:16:55.00

plasma, full length
some early hards
B_R now a bit positive at t=0
Jun 26 2012 10:45:24:827AM1120626007Earl Marmarnl_04 target to 7.88e19
PG5 argon puff moved earlier (start at 0.3 s, still 60 ms)
Load at 26-Jun-2012 10:29:53.00

plasma, full length
startup looks ok
Jun 26 2012 10:59:11:263AM1120626008Earl Marmarnl_04 target to 9.0 e19
Load at 26-Jun-2012 10:29:53.00

plasma, disrupt in flattop, 1.2 s (brick?)
hesitation in startup, hards
Jun 26 2012 11:24:41:503AM1120626009Earl Marmarlocked mode
import segment 3 from 1120615009 into segment 3
turn off segment 2, turn on segment 3
Load at 26-Jun-2012 11:05:33.00

plasma, full length
no argon puff
Jun 26 2012 11:35:42:733AM1120626010Earl Marmarlocked mode
load from 1120615009
import segment 1 from 1120626009 into segment 1
Load at 26-Jun-2012 11:23:05.00

plasma, disrupt early in rampdown
large impurity event around 1 second
Jun 26 2012 11:46:42:367AM1120626011Earl Marmarnitrogen seeding
enable B side lower (PG1)
load from 1120615027
import segment 1 from model into segment 1
move argon puff 100 ms earlier (start at 0.3)
Load at 26-Jun-2012 11:37:26.00

plasma, full length
early hards
Jun 26 2012 11:48:40:487AM1120626012Earl Marmarreduce nitrogen (to 60 V from 70, same pulse length)
Load at 26-Jun-2012 11:46:38.00
Jun 26 2012 12:28:55:810PM1120626013Earl Marmarreduce nitrogen (to 55 V from 60, same pulse length)
nl_04 target to 8.53e19
Load at 26-Jun-2012 12:03:56.00

plasma, early disrupt, brick
Jun 26 2012 12:38:26:920PM1120626014Earl Marmarno dpcs changes

plasma, full length
Jun 26 2012 12:38:35:460PM1120626015Earl Marmarno dpcs changes

Jun 26 2012 01:07:42:413PM1120626016Earl Marmarload from 1120626011
Load at 26-Jun-2012 12:47:15.00

fizzle
Jun 26 2012 01:32:33:793PM1120626017Earl MarmarEF4 10 A less negative prior to t=0 (now -1290 A)
Load at 26-Jun-2012 13:06:16.00

plasma, bouncy startup, early hards
disrupt 1.05 s

Jun 26 2012 01:35:48:793PM1120626018Earl Marmarswitching to MP703 Commissioning of CECE
load from 1120607008 (including startup, non-cryopump)
pump out B-side lower (was N2) and refill with 1 PSI argon, enabled
disable H-bottom
Load at 26-Jun-2012 13:27:04.00

fizzle

Jun 26 2012 01:58:58:263PM1120626019Earl Marmarreduce prefill puff to 22 ms (from 26)
reduce early PG3
EF4 offset to -1290 A (from -1270)
Load at 26-Jun-2012 13:40:46.00

plasma, full length

Jun 26 2012 02:12:19:483PM1120626020Earl MarmarIp to 1.0 MA
Load at 26-Jun-2012 13:58:13.00

plasma
locked-mode 1.26 s
disrupt 1.31 s

Jun 26 2012 02:28:25:260PM1120626021Earl MarmarIp to 0.9 MA
Load at 26-Jun-2012 14:17:01.00

locks earlier (density undershoot around time of diversion)
disrupt 0.94 s

Jun 26 2012 02:39:05:357PM1120626022Earl Marmarnl_04 target to 5e19
Load at 26-Jun-2012 14:26:49.00

fizzle
Jun 26 2012 02:56:04:670PM1120626023Earl MarmarEF4 current to -1300 A (from -1290 A) prior to t=0
start TF rampdown at 1.5 s (instead of 1.6)
Load at 26-Jun-2012 14:37:40.00

plasma, full length
Jun 26 2012 03:10:12:800PM1120626024Earl MarmarTF current to -147.79 kA
Load at 26-Jun-2012 14:37:40.00
plasma, full length
small hesitation in startup
Jun 26 2012 03:21:42:623PM1120626025Earl MarmarTF current to -153.03 kA
Load at 26-Jun-2012 15:09:19.00

plasma, nearly full length
startup looks ok
Jun 26 2012 03:46:46:717PM1120626026Earl Marmarnl_04 target to 7.2e19
Load at 26-Jun-2012 15:20:19.00
power supply dud, no TF
Jun 26 2012 03:57:02:400PM1120626027Earl Marmarnl_04 target still 7.2e19
TF current to 150.0 kA
Load at 26-Jun-2012 15:39:26.00

plasma, nearly full length
some hards
Jun 26 2012 04:09:33:370PM1120626028Earl Marmarnl_04 target 8.2e19
Load at 26-Jun-2012 15:54:38.00

plasma, nearly full length
startup ok, no hards

Jun 26 2012 04:26:39:317PM1120626029Earl Marmarlocked mode shot
load from 1120626010
import segment 1 from model into segment 1
disable B-side lower (argon)
enable H-bottom (argon)
Load at 26-Jun-2012 16:13:32.00

plasma, nearly full length
locks around 0.67s through flattop

Jun 26 2012 04:42:46:000PM1120626030Earl Marmarload from 1120626023
import segment 1 from model into segment 1
disable H-bottom
enable B-side lower
Load at 26-Jun-2012 16:23:11.00

fizzle
fields and gas look ok, early breakdown, maybe a tiny bounce

Jun 26 2012 05:00:22:450PM1120626031Earl Marmarno addtional dpcs changes

plasma
some hesitation in startup
disrupt early in rampdown
Jun 26 2012 05:12:07:260PM1120626032Earl Marmarreduce prefill puff by 1 msec (now 21 msec)
Load at 26-Jun-2012 16:57:44.00

plasma, nearly full length

end of run

Engineering Operator Comments
ShotTimeTypeStatusComment
109:04:32:383AMPlasmaOk
209:19:31:080AMPlasmaOk
309:35:34:610AMPlasmaOk
409:49:04:967AMPlasmaOk
510:02:41:110AMPlasmaOk
610:17:51:167AMPlasmaOk
710:31:29:190AMPlasmaOk
810:49:46:480AMPlasmaOk
911:09:34:333AMPlasmaOk
1011:23:54:207AMPlasmaOk
1111:39:55:463AMPlasmaOk
1211:56:09:320AMPlasmaOk
1312:12:17:277PMPlasmaOk
1412:25:29:157PMPlasmaOk
1512:40:29:933PMPlasmaOk
1612:58:29:030PMPlasmaOk
1701:13:23:280PMPlasmaOk
1801:30:20:390PMPlasmaOk
1901:45:28:457PMPlasmaOk
2001:59:33:147PMPlasmaOk
2102:17:27:680PMPlasmaOk
2202:31:24:607PMPlasmaOk
2302:44:39:937PMPlasmaOk
2402:59:07:580PMPlasmaOk
2503:16:06:107PMPlasmaOk
2603:32:43:280PMPlasmaBadTF did not fire
2703:45:55:817PMPlasmaOk
2804:00:58:133PMPlasmaOk
2904:17:02:643PMPlasmaOk
3004:34:05:987PMPlasmaOk
3104:47:55:360PMPlasmaOk
3205:01:52:267PMPlasmaOk

System Availability
Jun 26 2012 09:04:12:050AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 2 2008 11:03:58:433AM (sears)Joe SnipesActive MHD Antennagolfit
BESyesBES system is onlineNov 22 2011 02:21:12:050PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
BolometersyesMidplane diodes functioning properly. Midplane bolometers working and calibrated. DIV bolometers installed but not yet toaster calibratedApr 20 2012 09:57:29:520AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationyes Jun 15 2012 05:02:46:313PM (dekow)Jim IrbyBoronizationdekow,irby
CECEno Jan 6 2012 03:48:47:060PM Anne WhiteCorrelation ECEwhitea
CNPAyesMultiple channel CNPA available, no safety risk for in-vessel accessApr 14 2011 12:01:59:693PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper Divertoryes Jun 15 2012 05:02:31:550PM (dekow)Brian LaBombardUpper Divertor Cryopumpdekow,irby,labombard
CXRSyescore-CXRS system is onlineNov 22 2011 02:21:22:280PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
CXRS edgeyesMichael CHurchill has primary responsibility at the momentApr 19 2011 11:44:46:247AM (blip)Bruce LipshultzMeasurement of CXR light in the pedestal region at both the high- and low-field sidesblip,rmchurch
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 1 2009 09:45:41:090AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsanosystem is is installed and aligned, but not functional (appears to be a broken cable)Dec 5 2011 02:41:42:867PM (marmar)Earl MarmarVisible Bremsstrahlung Imagingmarmar
Disruption Mitigationyestwo gas jet valves active as of Feb 2012May 15 2012 10:09:23:597AM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 6 2007 10:50:41:677AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 6 2007 10:51:39:897AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DMBolo AXUV diodesyesDiodes are taking usable data. Not all post-processing code is working yet.Feb 1 2012 01:24:23:953PM (golynyk)Geoff OlynykSet of six AXUV diodes in a toroidal array of midplane wall boxes.golynyk,granetz,mlreinke,whyte
DNByes"The beam could break at any moment."May 15 2012 10:09:52:470AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,mochung
ECDCyes Apr 26 2012 03:23:19:057PM (dekow)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesFRC-ECE is onlineMay 14 2012 11:53:01:693AM (bespam)Perry PhillipsHeterodyne ECE-32 channelsbespam,liao,phillips,rowan,whitea
FTCIyesSystem OperationalMay 14 2012 11:50:45:590AM (irby)Jim IrbyFast two-color interferometerirby
G-Side RatiomaticyesInstalled April 25,2012. New controller installed 5/29/2012Jun 7 2012 10:40:00:957AM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoHV cables disconnected and power supplies off. Electrical plugs have been disconnected, capped and red tagged.Mar 5 2012 10:21:53:460AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperationalApr 27 2012 07:41:46:907AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPC2yesOperationalApr 27 2012 07:42:03:317AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 1 2009 09:45:50:933AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyessystem is functional and taking dataDec 5 2011 02:42:29:857PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Apr 26 2012 03:23:49:607PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36:33:420PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SryesInstalled and aligned. Will be available for Ti/Vr profiles after focusing tests and locked modes are taken.Dec 6 2011 08:21:02:453AM (ypodpaly)John RiceHigh Resolution X-Raycgao,ldelgado,rice,ypodpaly
HXRyes32 Channels operational,, no safety risk for in-vessel accessApr 14 2011 12:05:24:810PM (parker)Ron ParkerHard X-Ray Arrayfaust,parker,schmidt
ICRF D-Antennayes May 31 2012 09:20:06:827AM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayes May 31 2012 09:19:57:640AM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayes May 31 2012 09:19:47:443AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Impurity SpectroscopyyesBeing upgraded with better optics and new spectrographs. Dan Miller has primary responsibility.Apr 19 2011 11:46:02:193AM (blip)Bruce LipshultzMeasurement of recycling light and impurity source rates at multiple surfaces around the tokamakblip,miller
Laser Blow-OffyesPumped Down, Laser has not yet been tested but otherwise operationalMay 14 2012 04:31:17:037PM (nthoward)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridnoLH is now safe for manned entry into machine. Positioner locked and tagged off. Switches locked in dummy load position.Mar 2 2012 02:34:28:943PM (dterry)Ron ParkerLower Hybriddterry,parker,wallaceg
Lower Hybrid ReflectometernooffApr 15 2011 08:24:27:930AM (dominguez)Arturo DominguezLower Hybrid Reflectometerdominguez,marmar,parker,sgbaek
LoWEUSyesLoWEUS viewing the 10-30 nm region, spectral brightness vs. lambda and time are being stored in tree.Apr 20 2012 10:43:34:077AM (mlreinke)Matthew L. Reinke Long Wavelength Extreme Ultraviolet Spectrometermarkchil,mlreinke
LPInoBeam line removedMay 30 2008 02:09:12:833PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphayesMidplane Lyman-a. New B-PORT Lyman (BPLY) still being debugged.Apr 20 2012 10:44:00:540AM (mlreinke)Matt ReinkeLyman alpha camerasfaustian,labombard,mlreinke
Magneticsyes Dec 1 2011 11:51:51:970AM (g)Robert GranetzBp coils and flux loops for equilibrium controlgranetz,wolfe
McPhersonno McPherson viewing the 10-14 nm region for molybdenum monitoring. It's days are numbered as LoWEUS has demonstrated superiority.Apr 20 2012 10:44:10:937AM (mlreinke)Jim TerryVUV Spectrometermarkchil,mlreinke,terry
MichelsonyesVacuum 3-4e-8 T. Starting with Michelson at reduced speed.Apr 27 2012 07:42:41:960AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyes Dec 2 2011 12:27:47:163PM (toland)Brian LaBombardBaratron pressure gaugeslabombard,toland
MLPyesOperational. Connected to A-port probe systemMay 10 2012 08:40:19:910AM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEyes2/29/2012 MSE operational. No HV or vacuum safety issuesFeb 29 2012 12:26:13:863PM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for He3 detectors on J port. Remaining voltages will be turned on for the first run.Apr 23 2012 09:31:22:063AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesAll detectors Powered On --- Waiting for neutrons for calibrationNov 22 2011 01:05:24:380PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAyesC-bottom and new F-bottom system ready.Dec 2 2011 12:28:44:843PM (toland)Brian LaBombardNINJA gas pufflabombard,terry,toland
PCIyesOperational.May 1 2012 08:31:33:743AM (ntsujii)Miklos PorkolabPhase Contrast Imagingemd,ennever,ntsujii,porkolab
Penning GaugesyesHV power supplies turned ON in INIT, off in RECOOLMay 10 2012 08:41:03:000AM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 1 2009 09:46:29:543AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
Polarimeteryes3 chords operational but with high noise levelJan 6 2012 04:22:20:903PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Apr 26 2012 03:24:21:607PM (dekow)Gary DekowAlternator to Power Room Power Supply Connectioncochran,dekow,dterry,irby
Power - PEIyes Apr 26 2012 03:24:41:250PM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Apr 26 2012 03:24:57:153PM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Apr 26 2012 03:25:14:497PM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational. Some dead probes.May 10 2012 08:41:58:120AM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational. 4 out of 6 probes working.May 10 2012 08:41:40:557AM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperational.May 10 2012 08:42:13:733AM (labombard)Brian LaBombardOuter Lower Divertor Probe Array (F and J)labombard
Probe Array - UDIVyesOperational. Some dead probes.May 10 2012 08:42:32:663AM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesOn 1120608, the high frequency channels: 112, 140 and the variable, have been disconnected for some troubleshooting. All other channels are connectedJun 14 2012 11:28:59:603AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational. A variety of probe heads are ready for use.May 10 2012 08:43:10:937AM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.May 10 2012 08:43:24:887AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPnoNot functioning. Probe tips are melted. Repair not performed during break.May 10 2012 08:44:43:137AM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
Shoelace AntennayesOperationalMay 10 2012 08:45:08:320AM (labombard)Brian LaBombardHigh-k active MHD antenna, for QCM, WCM studiesgolfit,labombard
SOL reflectometeryesc-port (top, middle, bottom) and h-port available. Only 1 of 4 locations can be used for each dischargeMay 1 2012 04:54:58:820PM (cornwall)Cornwall LauSOL reflectometercornwall,wukitch,ylin
SparkeryesSparker Power Supply powered up. Connected at K port using red cable 4/23/12 9:25AMApr 23 2012 12:06:10:983PM (parkin)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationnoSSS is up to air, no safety issues.Feb 27 2012 01:51:48:783PM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesTCI lasers in operation May 14 2012 11:51:18:700AM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CoreyesOperating with one 50Hz laser, precise density calibration still required.May 9 2012 03:12:32:050PM (jwhughes)Jerry HughesCore Thomson scatteringjrwalk,jwhughes,yma
TS - EdgeyesOperating with one 50Hz laser, precise density calibration still required.May 9 2012 03:12:51:363PM (jwhughes)Jerry HughesMillimeter resolution edge Thomson scatteringjrwalk,jwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58:35:493AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesXEUS viewing the 1-6 nm region, spectral brightness vs. lambda and time are being stored in tree.Apr 20 2012 10:43:43:107AM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermarkchil,mlreinke
XTOMOyesARRAY1->5 available. Specific channels on various arrays display issues.Apr 20 2012 05:36:28:523PM (faustian)Robert GranetzX-Ray Tomographyfaustian,granetz,mlreinke