| Miniproposals | ||||||||||||||
| ||||||||||||||
|
| Operators | |
| Session leader(s): | Dan Brunner,Greg Wallace,Dan Brunner,Dan Brunner,Greg Wallace |
| Physics operator(s): | Ron Parker |
| Engineering operator(s): | Bill Parkin,Roza Tesfaye,Ed Fitzgerald |
| Engineering Operator Run Comment |
| AM: MP667, New SOL Probes, PM: MP665, LH Density Limit |
| Session Leader Plans |
| Entered: Aug 8 2012 10:25:38:787AM |
| Author: Dan Brunner |
| MP667: Commissioning of new SOL probes
9:00-12:30, budgeting for maximum of 12 plasmas. Due to limited number of plasmas, unlikely to repeat shots. The purpose of this run is to operate the new A-port scanning (ASP) retarding field analyzer (RFA) to measure ion and electron temperatures to the sepratrix. These will be used for comparison with (and hopefully validation of) ion temperature data with the ion sensitive probe (ISP). The ISP data covers a density scan at both 0.58 and 0.80 MA. There is already good data with the RFA at low densities and 0.8 MA. Reload shot 1120726019, 0.58 MA, 0.4e20 m^-2. Target probes. Increase density by ~0.1e20 m^-2 per shot until at ~0.8e20 m^-2. (total ~6 shots) Increase plasma current to 0.80 MA, decrease density to 0.7e20 m^-2. Target probes. Increase density by ~0.1e20 m^-2 per shot until time runs out. May take coarser density scan if time is running out. (total ~6 shots) Hand over to LH. Will piggyback with RFA to look for changes to electron/ion distributions with/without LH. CXRS will be puffing helium to get B+5 temperature profiles for comparison: Fill NINJA plenum with 6 psi Helium DISABLED. |
| Entered: Aug 9 2012 11:48:15:120AM |
| Author: Greg Wallace |
| Session leader plan for 1120809
MP665: Field, current, and q dependence of LH density limit SL: G. Wallace PO: R. Parker This will be the second attempt at MP665. The first attempt on 1120724 had difficulty getting to the desired low field conditions. Some data was obtained at 3 T, 0.55 MA and 4.1 T, 0.55 MA. This run will focus more on the low field, lower current discharges and try for some of the high field discharges as well. LH Setup: 90 deg phasing, 150 kW/klystron, launcher at 1278. Shot plan: 0) Load from 1120710020 (5.4 T, 550 kA, USN, no cryopump). Repeat as programmed with TS this time. 1) Load from 1120724012. Decrease Ip to 0.3 MA. Scan density from nl_04=4-8e19. 2) Repeat 1 at 0.4 MA. 3) Repeat 1 at 4.1 T, 0.3 MA. 4) Repeat 3 at 4.1 T, 0.4 MA. 5) Load from 1120727023 (6.3 T, 0.8 MA). Target nl_04 is 7e19. Note that target shot was in H with a He3 minority, so adjust density feedback and gas puffing accordingly. This shot will be to directly compare the H discharges from 1120727 with D discharges at the same Ip and Bt. 6) Repeat step 5 at 7 T, 0.8 MA. 7) Repeat step 5 at 7 T, 0.5 MA. 8) Repeat step 5 at 7 T, 1.1 MA. |
| Physics Operators Plans |
| Entered: Aug 8 2012 05:02:13:700PM |
| Author: Ron Parker |
|
Engineering setup for Thursday, Aug 9, 2012 AM: MP667 Commissioning of New SOL Probes PM: MP665 Field, Current and q-dependence of the LH Density Limit Session leader: Dan Brunner (AM) Greg Wallace (PM) Physics operator: Ron Parker Power systems as on: 1120808020 A-coil configuration: +Dtop -Dbot -Jtop +Jbot; Hybrid enabled (standard configuration) Gas Setup: fill B-Top with 6 psi D2 Hybrid enabled (PG4) fill B-side lower with 1 psi Ar Hybrid DISABLED (PG1) leave B-side upper as is Hybrid DISABLED (PG2) fill B-main (C-side) with 40 psi D2 Hybrid enabled (PG3) leave H-bottom as is Hybrid DISABLED (PG5) leave B-div as is Hybrid DISABLED (PG6) leave H-div as is Hybrid DISABLED (PG7) Fill NINJA with 6 psi He Disabled Enable the following gate valves and shutters, assuming no vacuum problems: ECE, VUV, Z-bolo, HIREX-Sr, B-spectrometer GV, Xeus, LoWEUS Torvac setup: keep gate valves open during pulse Required systems: cryopump Required diagnostics: AM: scanning ISP, emissive & RFA as well as AB-RFA; PM: TS, TCI, ECE, x-ray camera, PDI probes Desired diagnostics: edge Thomson and X-mode reflectometer ------------------------------------------------------------------------------ Boronization overnight: No ICRF: No LH: Yes, in PM Impurity injector: No DNB: Not required, may be useful in PM if available Cryopump: Yes, in PM ------------------------------------------------------------------------------ Run plan: Refer to SL's plans |
| Session Leader Summaries |
| Entered: Aug 9 2012 01:39:36:267PM |
| Author: Dan Brunner |
| Good run. Set out to get density scan at 0.58 and 0.80 MA and completed both. Nearly perfect shot performance. Only first shot disrupted, injection and slow death.
Got extra innings while LH sorted out trouble moving launcher in. Got two low density points at 1.2 and 1.1 MA. Far SOL only. Now have RFA ion and electron temperature to compare to ISP. Unlike previous runs, there was no arcing or shots between the electrodes and ground between scans! The solution was complete coverage with mica. Mica tight through all of the corners and mica extending out past the electrodes. Although a new source of arcing is now differentiated: during the plasma scans. There were arcs during the first scans of the day, likely the grids cleaning up? Then there were arcs mainly during the first scan, ionizing the neutral gas built up between shots? Then there were arcs when scanned to at least a certain depth, too much plasma recycling inside the probe (something like this has been seen on other machines, e.g. JET's RFA RSI). Time to polish up RFA analysis code and compare profiles to ISP. |
| Entered: Aug 10 2012 06:01:19:527PM |
| Author: Greg Wallace |
| A very interesting run today. We started at low field (3 and 3.9 T) and had not much success. We then went to higher fields (6.3 and 7 T) and had great success. Preliminary analysis shows non-trivial current drive at nebar = 1.1-1.3e20 at the higher fields and 800 kA! This result is very encouraging but also very confusing. Seung Gyou reports that PDI is stronger as compared to the 6.3 T H2 discharge, but current drive seems nearly identical. We will need to compare x-ray results with the old 7 T data from 2008, but this will require re-analyzing the 2008 HXR raw data with the latest analysis technique. |
| Physics Operator Summaries |
| Entered: Aug 9 2012 05:56:27:927PM |
| Author: Ron Parker |
| A good day!
Machine ran well and good progress was made toward the goals of both MP's For MP667, Ohmic shots were run with currents ranging from 0.5 - 1.2 MA, and with density scans at each current. We took advantage of a delay inpreparing the LH system to extend this part of the run by 2 shots. All shots called for on the SL plan were run. For MP665, we had difficulty running and coupling to a 3 T plasma, so we decided to move on to 4 T (actually 3.8 T). It wasn't perfect because LH was faulting but good enough to determine the "density limit". We then moved on to 6.3 T, where we found evidence of current drive up to n_bar = 1.3e20 m-3. We then ran a 7 T shot for comparison, and again found reduction of loop voltage at 1.3e20 m-3. we ran out of time for this part of the run and could use about 2 more hours to complete it. The remaining question is: is the higher "density limit" we seem to be finding with the USN plasmas due to q or field? There were a couple of delays during the run, one due to problems in inserting the LH antenna, the other due to a drop of water pressure in the alternator house. Nevertheless we ran 31 shots most of which were useful. Scorecard: 30 plasma attempts, one no power (water pressure), two disruptions before rampdown, one runaway shutdown, no fizzles (a robust startup!) and the rest full length. |
| Session Leader Comments | |||
| Aug 9 2012 08:38:59:720AM | 1120809001 | Dan Brunner | Setup: Reload shot 1120726019, make no changes.
Result: Next Shot: |
| Aug 9 2012 08:57:48:023AM | 1120809001 | Dan Brunner | Delay due to alternator. First shot may be ~9:15. |
| Aug 9 2012 09:19:31:237AM | 1120809001 | Dan Brunner | Setup: Reload shot 1120726019, make no changes.
Result: Strange shot, radiation and density increase, current and temperature decrease, then disruption. Next Shot: Try again. |
| Aug 9 2012 09:31:33:153AM | 1120809002 | Dan Brunner | Setup: Try again.
Result: Good plasma, everything seems to be working. Next Shot: Repeat, push probe in deeper, enable NINJA. |
| Aug 9 2012 09:46:01:343AM | 1120809003 | Dan Brunner | Setup: Try again.
Result: Good plasma, everything seems to be working, some arcing between grids at deepest insertion. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 09:59:01:560AM | 1120809004 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, still arcing at peak insertion, third scan looks ok. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 10:11:23:390AM | 1120809005 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, data looks ok. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 10:24:55:620AM | 1120809006 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, data looks good. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 10:40:18:060AM | 1120809007 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, data looks good. Next Shot: Increase plasma current to 0.8 MA, keep density at 0.7e20 m^-2. |
| Aug 9 2012 11:00:43:420AM | 1120809008 | Dan Brunner | Setup: Increase plasma current to 0.8 MA, keep density at 0.7e20 m^-2.
Result: Good plasma. Next Shot: Repeat, probe in deeper. |
| Aug 9 2012 11:12:46:407AM | 1120809009 | Dan Brunner | Setup: Repeat, probe in deeper.
Result: Good plasma, good data. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 11:26:59:777AM | 1120809010 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, good data. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 11:41:00:240AM | 1120809011 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, good data. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 11:53:00:490AM | 1120809012 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, good data. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 12:07:31:267PM | 1120809013 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, good data. Next Shot: Increase density by 0.1e20 m^-2. |
| Aug 9 2012 12:20:20:440PM | 1120809014 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2.
Result: Good plasma, good data. Next Shot: Repeat shot 3 (0.58 MA, 0.38e20 m^-2). |
| Aug 9 2012 01:13:40:987PM | 1120809015 | Dan Brunner | Setup: Repeat shot 3.
Result: Good plasma, good data. Next Shot: Extra innings while LH sorts out some issues. Increase plasma current to 1.1 MA. |
| Aug 9 2012 01:26:07:963PM | 1120809016 | Dan Brunner | Setup: Extra innings while LH sorts out some issues. Increase plasma current to 1.1 MA.
Result: Good plasma, good data, current accidentally 1.2 MA. Next Shot: Increase density by 0.1e20 m^-2, decrease current to 1.1 MA, push probe in deeper. |
| Aug 9 2012 01:37:29:447PM | 1120809017 | Dan Brunner | Setup: Increase density by 0.1e20 m^-2, decrease plasma current to 1.1 MA, push probe in deeper.
Result: Good plasma, good data. Next Shot: LH fixed my sabotage! Handing run back over. Thanks for the extra two shots. |
| Aug 9 2012 01:45:12:180PM | 1120809018 | Greg Wallace | Runaway shutdown. First attempt at repeating shot 1120710020. Try again. |
| Aug 9 2012 02:08:12:157PM | 1120809019 | Greg Wallace | Repeat attempt of shot 1120710020. Want 700 kW, 5.4 T, 550 kA, nebar=1.2e20.
Got 450 kW at 110 kW/klystron, 90 deg. Got other parameters right. One fault, possible breakdown on plasma side based on reflected power but nothing visible on cameras. Next shot will repeat with 150 kW/klystron and reduce outer gap by 5 mm. |
| Aug 9 2012 02:19:35:967PM | 1120809020 | Greg Wallace | Three early faults at 150 kW/klystron, 90 deg. Looks like could be plasma side breakdown on reflected power signals but nothing on camera.
Discharge nearly goes limited just before the LH pulse starts. Crossover problem? Try one more time for this condition. |
| Aug 9 2012 02:38:38:193PM | 1120809021 | Greg Wallace | One fault early in the LH pulse at 150 kW/klystron. Change in outer gap did not come through.
Next shot will try again to repeat the same conditions as 1120710020, including longer LH pulse length (0.6-1.4 s) and outer gap reduced by 5 mm. |
| Aug 9 2012 02:49:17:797PM | 1120809022 | Greg Wallace | Sufficiently similar to shot 1120710020. One fault early when the plasma tries to go inner wall limited.
Next shot will move on to 3T, 300 kA with density ramp (step 1 of run plan). LH parameters will remain constant. |
| Aug 9 2012 03:08:11:437PM | 1120809023 | Greg Wallace | Shot cycle hung. |
| Aug 9 2012 03:32:26:607PM | 1120809024 | Greg Wallace | Poor LH coupling. Disruption at 1.15 s. Plasma does not look very good.
Next shot will move on to step 4, 4.1 T, 0.4 MA. |
| Aug 9 2012 03:45:24:807PM | 1120809025 | Greg Wallace | Field a little lower than expected (3.75 vs 4.1 T). Lots of tripping, looks like it might be due to breakdown on the vacuum side?
Next shot will repeat with lower LH power (120 kW/klystron) to try to keep it from arcing(?). |
| Aug 9 2012 03:55:03:683PM | 1120809026 | Greg Wallace | Many faults again, but a little better. Perhaps the outer gap is too small at the higher density and that is causing the breakdown on the plasma side? Next shot will ramp RCUR by 5 mm between 0.6 and 1.4 s. |
| Aug 9 2012 04:11:20:413PM | 1120809027 | Greg Wallace | LH coupling better now, but still not great. Outer gap scan seemed to help. Next shot will go on to step 5 (6.3 T, 800 kA; repeat of 1120727023). |
| Aug 9 2012 04:32:45:513PM | 1120809028 | Greg Wallace | Good shot! Clean LH pulse. Next shot will repeat at higher power (170 kW/klystron) and decrease pulse length (0.8-1.3 s) to better match 1120727023. |
| Aug 9 2012 04:40:58:327PM | 1120809029 | Greg Wallace | Clean LH pulse at 170 kW/klystron, 90 deg, 6.3 T, 800 kA! Vloop changes almost exactly the same as shot 1120727023!!! Next shot will repeat with a density scan. |
| Aug 9 2012 04:57:52:073PM | 1120809030 | Greg Wallace | Another good shot! Still driving current! Not a huge density ramp but we will move on and try for one shot at 7 T, otherwise same conditions as shot 29. |
| Aug 9 2012 05:15:46:960PM | 1120809031 | Greg Wallace | Another good shot. 7T, clean LH. Last shot of the day. Still looks like some current drive. Very confused. |
| Physics Operator Comments | |||
| Aug 9 2012 09:21:07:997AM | 1120809001 | Ron Parker | Shot 1 disrupted early, around 0.65 s.
|
| Aug 9 2012 09:30:29:423AM | 1120809002 | Ron Parker | Shot 2 ran full length. |
| Aug 9 2012 09:42:39:557AM | 1120809003 | Ron Parker | Shot 3 ran full length |
| Aug 9 2012 10:01:38:483AM | 1120809004 | Ron Parker | Shot 4 ran full length, density was increased by 0.1e20 m-2 relative to shots 2 and 3
Next shot will have an additional programmed increase in n of 0.1e20 m-2. |
| Aug 9 2012 10:19:50:013AM | 1120809005 | Ron Parker | Shot 5 ran full length. Continue to add 0.1e19 m-2 to the shot. |
| Aug 9 2012 10:42:15:297AM | 1120809006 | Ron Parker | Shot 6 ran full length, continuing to increment density |
| Aug 9 2012 10:43:05:250AM | 1120809007 | Ron Parker | Shot 7 ran full length.
Next: Same density, ramping current up to 800 kA |
| Aug 9 2012 10:55:49:887AM | 1120809008 | Ron Parker | Shot 8 ran full length |
| Aug 9 2012 11:13:56:150AM | 1120809009 | Ron Parker | Shot 9 ran full length.
Next: Increase density by 0.1e20 m-2 |
| Aug 9 2012 11:27:45:657AM | 1120809010 | Ron Parker | Shot 10 ran full length
Next: Increment density by 0.1e20 m-2 |
| Aug 9 2012 11:40:37:683AM | 1120809011 | Ron Parker | Shot 11 ran full length
Next: Increment density by 0.1e20 m-2 |
| Aug 9 2012 11:56:31:707AM | 1120809012 | Ron Parker | Shot 12 ran full length. Continue ot increment density |
| Aug 9 2012 12:09:02:923PM | 1120809013 | Ron Parker | Shot 14 ran full length.
Continue to increment density by 0.1e20 m-2/shot |
| Aug 9 2012 12:28:45:267PM | 1120809014 | Ron Parker | Shot 14 ran full length.
Next: Reproduce (or at least reload) shot 3 |
| Aug 9 2012 12:40:20:003PM | 1120809015 | Ron Parker | Shot 15 ran full length.
This comletes Dan Brunner's par of the run (MP667) We will now begin with the MP665 part of the run, with Greg Wallace as SL. The first shot will be loaded from 1120710020 |
| Aug 9 2012 01:10:06:380PM | 1120809015 | Ron Parker | We're having trouble moving the LH launcher in. So while this is being worked on (out of the cell!), we'll resume Dan's run.
Beging by loading a 1.1 MA, nlo4 ~ 0.6e20 m-2 |
| Aug 9 2012 01:23:52:800PM | 1120809016 | Ron Parker | Shot 16 ran full elngth, first shot at 1.1 MA in Dan's run
Oops, make that 1.2 MA (but it should have been 1.1 MA, which will nbe programmed of next shot.) |
| Aug 9 2012 01:39:15:057PM | 1120809017 | Ron Parker | Shot 17 ran full length.
LH launcher is fixed and in position. we'll start now on MP 665 beginning with a 5.4 T shot, 1120710020. |
| Aug 9 2012 01:49:50:550PM | 1120809018 | Ron Parker | Runaway shutdown. We attempted to go USN which may have cleaned the upper divertor. Try again with 5 ms more prefill |
| Aug 9 2012 02:21:14:383PM | 1120809019 | Ron Parker | Shot 19 came back, ran full length and had LH
Next: same shot, increase LH power, and reduce outer gap by 1 cm |
| Aug 9 2012 02:23:17:967PM | 1120809020 | Ron Parker | Shot 20 ran full length, same outer gap, so the R_cur change must not have been loaded.
Try again, decreasing outer gap by 1 cm, hopefully |
| Aug 9 2012 03:01:41:120PM | 1120809021 | Ron Parker | Shot 21 ran full length, same as 20 |
| Aug 9 2012 03:00:07:250PM | 1120809022 | Ron Parker | Shot 22 ran with reduced outer gap, more or less reproducung 1120710020.
Now we'll move on to lower field as described on the runplan, starting with 1120724012 but with a density ramp and I_p = 300 kA |
| Aug 9 2012 03:05:09:140PM | 1120809023 | Ron Parker | Shot 23 was a no power shot, water pressure in the alternator supply had dropped and forced a trip |
| Aug 9 2012 03:08:53:540PM | 1120809023 | Ron Parker | There are stillproblems in the alternator house -- alternator is not ramping up |
| Aug 9 2012 03:58:54:080PM | 1120809024 | Ron Parker | Shot 24 ran (300 kA, 3 T) but disrupted around 1.15 s.
Rather than tune this shot, we'll start with shots at ~ 4 T |
| Aug 9 2012 03:39:25:637PM | 1120809025 | Ron Parker | Shot 25 ran full length, 400 kA, 3.8 T
Good shot, but LH keeps tripping |
| Aug 9 2012 03:59:51:200PM | 1120809026 | Ron Parker | Shot 26 ran FL, but LH still tripping |
| Aug 9 2012 04:26:52:957PM | 1120809027 | Ron Parker | Shot 27 ran fulllength. LH better with an R_cur sweep, but still faulting |
| Aug 9 2012 04:25:40:563PM | 1120809028 | Ron Parker | Shot 28 ran full length and seems to have some current drive at 1.3e20 |
| Aug 9 2012 04:43:34:473PM | 1120809029 | Ron Parker | Shot 29 ran FL. Good LH pulse, clear heating and current drive |
| Aug 9 2012 05:17:12:407PM | 1120809031 | Ron Parker | Full length. Good LH pulse, and clear falloff of LH efficiency at 6.9 T. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:14:10:377AM | Plasma | Ok | |
| 2 | 09:26:46:140AM | Plasma | Ok | |
| 3 | 09:39:26:430AM | Plasma | Ok | |
| 4 | 09:52:04:600AM | Plasma | Ok | |
| 5 | 10:06:19:670AM | Plasma | Ok | |
| 6 | 10:19:57:980AM | Plasma | Ok | |
| 7 | 10:34:24:227AM | Plasma | Ok | |
| 8 | 10:53:30:773AM | Plasma | Ok | |
| 9 | 11:07:15:303AM | Plasma | Ok | |
| 10 | 11:20:43:627AM | Plasma | Ok | |
| 11 | 11:34:24:657AM | Plasma | Ok | |
| 12 | 11:47:51:573AM | Plasma | Ok | |
| 13 | 12:01:07:313PM | Plasma | Ok | |
| 14 | 12:14:40:637PM | Plasma | Ok | |
| 15 | 12:27:54:600PM | Plasma | Ok | |
| 16 | 01:14:57:627PM | Plasma | Ok | |
| 17 | 01:27:35:700PM | Plasma | Ok | |
| 18 | 01:42:05:013PM | Plasma | Ok | |
| 19 | 01:57:32:280PM | Plasma | Ok | |
| 20 | 02:10:16:840PM | Plasma | Ok | |
| 21 | 02:22:53:453PM | Plasma | Ok | |
| 22 | 02:38:07:957PM | Plasma | Ok | |
| 23 | 03:00:07:280PM | Plasma | Bad | ALT City H2o was low, No power shot. |
| 24 | 03:20:26:793PM | Plasma | Ok | |
| 25 | 03:34:14:953PM | Plasma | Ok | |
| 26 | 03:47:29:107PM | Plasma | Ok | |
| 27 | 04:00:09:760PM | Plasma | Ok | |
| 28 | 04:18:54:257PM | Plasma | Ok | |
| 29 | 04:33:06:957PM | Plasma | Ok | |
| 30 | 04:49:37:380PM | Plasma | Ok | |
| 31 | 05:06:51:513PM | Plasma | Ok | |
| System Availability | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 09:13:52:407AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 09:33:50:767AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| He Ninja gas puff (6 PSI) from C-Port plenum, LFS and HFS
Hits plasma approximately at 1.3s trig1: 1.16s, 0.08s-> E_Top trig2: 1.22s, 0.08s-> B16-001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 10:31:48:387AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Increase plenum pressure to 9 PSI
Otherwise, everything unchanged: He Ninja gas puff (9 PSI) from C-Port plenum, LFS and HFS Hits plasma approximately at 1.3s trig1: 1.16s, 0.08s-> E_Top trig2: 1.22s, 0.08s-> B16-001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 10:48:34:400AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Use F-port plenum for HFS puff now;
He Ninja gas puff (9 PSI) from C-Port/F-port plenum, LFS/HFS Hits plasma approximately at 1.3s trig1: 1.16s, 0.08s-> E_Top trig2: 1.22s, 0.08s-> B16-001 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 10:51:21:747AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| shutter sync fails. Try shutterless operation on Ph1
covered views: A1, A16, B1, C1, C16 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 11:21:49:743AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| go also shutterless on Ph2.
covered fibers: A1, A17, B1, B17, C1, C17 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Aug 9 2012 11:52:20:210AM | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Increased plenum pressure to 13 PSI | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||