Alcator C-Mod Run 1120822 Information

Back to runs

Miniproposals
Miniproposal:694
Date Filed: 5/17/2012
Title:Transport of helium impurity in L-mode, H-mode, and I-mode.
First Author:Ken Liao
Session Leader:Ken Liao (shots 1-30)

Operators
Session leader(s):Ken Liao
Physics operator(s):Steve Wolfe
Engineering operator(s):Bill Parkin,Bill Cochran

Engineering Operator Run Comment
MP 694 - Transport of helium impurity in L-mode, H-mode, I-mode

Session Leader Plans
Entered: Aug 21 2012 03:36:27:140PM
Author: Ken Liao
Session leader plan for 1120822
MP 694 - Transport of helium impurity in L-mode, H-mode, I-mode

Required systems: DNB, Thompson Scattering, ICRF

Shot plan:

Begin with 2 boronization recovery shots, based off reference shot 1070730018 (H-mode, LSN). Begin with 30ms He4 puff from PG5 each shot at 1.0s. Adjust neon seeding as necessary.

Attempt EDA H-mode shots based on 1070730018 (H-mode, LSN), but use a constant 2.8MW ICRF power from 0.7s - 1.5s.
After getting EDA H-mode, Repeat configuration 4 times with different beam start times.
If we are having too much trouble getting H-mode, then move on to I-mode. Don't spend more than 8 shots here.

Generate 4 I-mode shots attempting to replicate 1110215016, except try to have constant input power of 3.0MW during flat top, using 4 different beam start times.

Turn off neon
Generate 4 ohmic shots using the same equilibrium, nl04 ~ 0.6e20, using 4 different beam start times.

Switch to a density scan, starting at nl04 = 0.4. Repeat shot, increasing nl04 by ~0.1 each shot, until nl04 ~ 1.2.

If we have time, switch main bottle to Helium-4, run Ohmic plasma, nl04 ~0.6, for several shots until Helium density rises to ne/2.

Beam timing:
Begin with 60/20 timing, starting at 0.500 seconds, 14 beam pulses
Beam start time will be toggled between shots between 0.500, 0.520, 0.540, 0.560, at SL's direction.


Physics Operators Plans
Entered: Aug 21 2012 06:34:18:787PM
Author: Steve Wolfe
PhysOp Plan and Engineering Setup for Wed. Aug 22, 2012
MP#694 Transport of helium impurity in L-mode, H-mode, and I-mode
SL: Liao
PO: wolfe

-----------------
Engineering Setup
-----------------
REVERSE FIELD RUN

Overnight boronization requested, standard prescription
2 hours of He ECDC following boronization

There is a possibility that this run may be delayed because
there is a DNB problem with transferring LHe.

**** Cryopump requested, starting from first shot ****

Run begins at 09:00 and ends at 17:00

Power systems as on: 1120821016 (note early EF1 crowbar)

Acoil: -Dtop +Dbot +Jtop -Jbot (standard reverse field) Hybrid Enabled


Gas setup:
----------
Fill B-Top with 6 psi D2 Hybrid enabled (PG4)
fill B-side lower with 3 psi Ne Hybrid DISABLED (PG1)
leave B-side upper as is Hybrid DISABLED (PG2)
fill B-main with 40 psi D2 Hybrid enabled (PG3)
fill H-bot with 10psi He Hybrid DISABLED (PG5)
fill NINJA with 10 psi D2 DISABLED

Enable gate-valves and shutters: ECE, VUV, HiREX Sr, Xeus/LoWEUS
Leave z-bolo shutter as is (should be open)

Torvac gatevalve toggle (yes/no): no

Boronization(yes/no): YES
Overnight ECDC (yes/no): Following boronization
ICRF(yes/no): YES
LH(yes/no): no
Cryopump (yes/no): YES
DNB (yes/no): YES

Vessel temperature: 35/35/35

------------------------------
ECDC Parameters (if requested)
------------------------------
gas and pressure: He at 5e-5 Torr
sweep: 44/45/103 cm
scan: 20/120 s

Physop plan
------------

The following can be modified to conform to the SL_PLAN when it
gets finalized.

We will attempt to access three (maybe four) confinement modes
and document profiles of injected helium. We will start by trying
to access EDA H-modes with unfavorable drift, at low current and low
density so the DNB can penetrate. A reference shot is 1070730018.
A similar target in many respects is 1120821016, but without the LH
and with 2.5 to 3MW of ICRF. Start with nl04=7e19 and see what we get.
Need to keep a reasonably large outer gap to avoid overheating the
outer limiters, so reduce RCUR to .657 (same as 1070730018) from .660.
May need to provide some neon seeding to keep the
inner divertor cool. Start with boronization recovery shots for ICRF.
Establish He puff level for satisfactory signal in L-mode plasmas;
start with 30msec puff, starting about t=1.0sec, during RF pulse.
Get to EDA H-mode conditions as quickly as possible. We will want up
to four EDA shots with consistent conditions, but we do not want to
struggle with this all day. After 8 tries, move on to the I-mode case.

Load an I-mode target from 1110215016, which is essentially a clone
of 1120820024, except for the TF current, which I'll need to set back
to 159700 for 5.8T. This is a 1MA, 7e19 case with RF from 2.2 to 3.2MW.
In the older shot the density program is run negative after 1.0sec,
and the Ip does not flattop until about 0.6sec. The Neon seeding from
B-side lower was from .32 to .45sec, at 1.9psi. Need to set up the
He puff on PG5. Need to remember to have engineering setup
changed to 1120820024 and increase TF_CURRENT limit from 165 to 170kA,
if it isn't already.

Note added after saving initial shot: Matt is recommending that
a shot from Tuesday, e.g. 1120821022, which has improved strike
point location be used for the I-mode target.
The ZCUR for that shot is pushed back up to
zero, and there are complicated waveforms on RXL and ZXL. It is
also at 1.1MA, and has the early divert and early EF1 crowbar
setting, and some EF1 voltage changes, which I don't think are
necessarily a good idea. I'll look this over in the morning.


Run ohmic case at nl04=0.6e20, using same equilibrium as I-mode.
Can turn off neon seeding from here on in.
Next we will do an ohmic density scan,
nl04= 0.4 to 1.2e20. This is allocated 9 shots.

Finally, if there is time, go to He fueled ohmic discharge at 0.6e20.
Easiest way would be to run the H-bottom plenum up to 40psi and change the NL04
controller from PG3 to PG5. Probably should turn off the pg3
puff in seg1, if we aren't having runaway issues. Alternatively, pump and
purge B-main and replace with 40psi He.


Session Leader Summaries
Entered: Aug 22 2012 06:27:13:877PM
Author: Ken Liao
Unfortunately, we weren't able to obtain EDA H-modes or steady I-modes, so not all of the goals of the run were met. We had two disruptions on Ohmic shots, but we were able to get decent data in the ohmic L-mode case. The beam was operating at lower beam voltage and current than in 2011, which resulted in reduced beam enhancement, but it should be sufficient for density profiles in the case of ohmic shots. We finished the run with an abbreviated density scan in ohmic plasmas.

We started off late due to having to replace the liquid helium dewar for the DNB cryopumps, but we made up the time by running to 6pm.

The beginning of the run had a lot of difficulty due to a lengthy boronization recovery time for the ICRF antennas. We got some H-modes, but the ICRF faults prevented them from lasting very long, and we probably didn't get EDA H-modes. There was also a large amount of ICRF outgassing which prevented us from keeping a low or steady density. We obtained some short I-modes, which ended presumably because the density would rise above the I-mode accessibility region for a given power. The ICRF outgassing showed up before last night's boronization, but the boronization might have made it worse.

We should be able to get radial helium transport from the time dependent density profiles for the ohmic case.

Physics Operator Summaries
Entered: Aug 22 2012 06:31:46:060PM
Author: Steve Wolfe
PO Summary for Wednesday, Aug 22, 2012
MP#694 Transport of He impurity...
SL: Liao
PO: wolfe
EO: Parkin, Cochran

The machine ran well today, but only a fraction of the run
plan was accomplished. The main problem was that the ICRF
was causing unusually high levels of gas evolution, preventing
density control during the planned H-mode and I-mode phases of
the experiment. Finally, we went to the ohmic L-mode part of
the plan, but were slowed by a cooling-induced leak. We managed 
to get through most of the planned density scan, though with 
fewer repetitions than wanted. 

The run started late because the DNB, which was critical for the
experiment, had run out of LHe and we did not start spinning up the
alternator until it was clear that a new dewar would be delivered. 
The run went from 10:17 until 18:00. 

Both the 600kA and 1.0MA plasma setups ran well, with only small
changes to the shape programming. However, the boronization recovery
was never really completed, in the sense that a lot of neutral 
pressure rise occurred every time the ICRF turned on. Eventually
the RF got past the faulting stage, but the density continued to
ramp up above 1e20 during the RF. This prevented us from sustaining
either EDA H-modes or I-modes, and also reduced DNB penetration to 
unusable levels. 

The I-mode phase used essentially the same shape adjustments that 
Ian and Matt developed on Tuesday, with the ZCUR raised to the 
midplane and ZXL up far enough to get the inner strike off the lower
tile, and also swept the outer strike up the vertical plate to spread
the heat load. We did succeed in getting I-modes, not great ones, that
lasted from .55 to 1 sec, until the density rose too much. It's possible
that the decreasing lower triangularity associated with the strike point
sweep compromised the I-mode, but most likely the evolving density
was the problem. There was a very small power window at the start
of RF between the I-mode threshold, around 4MW, and the H-mode threshold
aroud 4.5MW. However ramping the power up to 5MW as the density evolved
(shot#19) had no H-mode, just an I->L transition around 1sec. 

The cryopump was used for the first 20 shots, without causing any 
burps during shots. However, toward the end it did start having to
be regenned more than once before it would cool correctly, so we 
turned it off after the first ohmic shot. It wasn't clear that it
was having any effect on the RF heated shots. 

We had what were probably locked mode early disruptions on the 2nd and
3rd ohmic attemps (21-22), which were programmed for 5.5e19 with 
no higher density point earlier. Shot#20 had been programmed identically,
and had no problem. After re-programming nl04 to have an early density
bump to 7e19 before the flattop, we had no more disruptions. 

Starting on shot#25 we started getting leaks associated with the TF
cooling, as the vessel got down to 20C and the mass 28, 14, and 40 
came up. This slowed the shot rate to ~20minutes for the rest of the
run. 

Scorecard: 
           Tests/No power          0
           Duds                    0
           Fizzles                 0
           Plasmas                30 (including 2 early disruptions)
           ==========             ==
           Shots                  30

Session Leader Comments
Aug 22 2012 08:30:34:287AMKen LiaoWe are looking at a ~1 hour delay for the start of the run in order to refill the DNB cryopumps with liquid He.
Aug 22 2012 09:44:12:187AMKen LiaoHelium has been installed in the DNB.
Aug 22 2012 10:29:17:007AM1120822001Ken LiaoBoronization recovery shot. RF is faulting and needs to clean up.
Plenty of helium signal at 1 second. Beam did not fire for some reason.
Aug 22 2012 10:44:37:860AM1120822002Ken LiaoBoronization recovery shot.
Plenty of helium signal at 1 second. DNB fired successfully, at about 45kV, 5A. Helium signal enhancement is around 5%. Several channels are slightly saturated.

Next shot, ICRF will ramp up to try to recover faster. Move helium puff to 0.9, and reduce length to 25ms.
Aug 22 2012 11:01:22:680AM1120822003Ken LiaoBoronization recovery shot.
J-port still faulting a lot. Still saturating helium channels.

Next shot, reduce helium puff to 15ms.
Aug 23 2012 09:58:43:240AM1120822004Ken Liao15ms is not enough helium. Very little rise is seen.
J-port still faulting a lot. E port also faulting.
Beam enhancement ~5%

Next shot, increase helium puff to 20ms.
Aug 22 2012 11:27:39:200AM1120822005Ken LiaoHelium puff seems about right.
J-port still faulting a lot. E port also faulting.

Next shot, move ICRF start time to 0.5 to give more time for ICRF to condition.
Aug 22 2012 11:43:39:403AM1120822006Ken LiaoICRF somewhat cleaner. J port cleans up after 1 second. Beam seems somewhat ok. Helium levels are good.

Next shot we will put ICRF at 2.8MW, starting at 0.7 seconds.
Aug 22 2012 11:57:18:463AM1120822007Ken LiaoICRF is running at 2.8MW, but with many faults. Get H-modes at ~0.8, 1.05, 1.28. H-modes visible in helium spectrum by decrease in ambient helium intensity.

Next shot increase density to try to get EDA H-modes
Aug 22 2012 12:20:08:870PM1120822009Ken LiaoH-modes at 0.8, 1.05, 1.3. nl04 gets to 1.35 during third H-mode. ICRF still flakey, and we can't continue until it cleans up, so keep trying.
Aug 22 2012 12:39:36:117PM1120822010Ken LiaoICRF does look somewhat better. H-modes around 0.85-1.04, 1.25-1.35, 1.45-1.5
Helium signal seems somewhat less.
Aug 22 2012 12:51:49:087PM1120822011Ken LiaoH-mode at 0.85. Helium signals looking pretty small now. ICRF all antennas fault at 0.9, then J-port faulting almost periodic after 1 second. Beam enhancement very small.

Next shot, increase helium duration to 30ms.
Aug 22 2012 01:08:19:780PM1120822012Ken LiaoHelium signal quite a bit higher now. ICRF is somewhat cleaner. H mode at 0.9, but no others.

Toroidal CXRS channels appear to have a considerably different time trace than poloidal channels between 1.0 and 1.3 seconds.

Next shot, try higher ICRF. 3MW.
Aug 22 2012 01:39:54:917PM1120822013Ken LiaoHigher power, but no H-modes, so we will switch over to I-mode configuration. There were some injections. Beam lost a few pulses. ICRF is fairly clean. Beam enhancement is more or less invisible even before entering H-mode, so move on to I-mode.

Injection is visible on CXRS toroidal channel at 0.777m at 1.096s, then immediately afterwards in all channels.

Next shot, switch over to I-mode shots similar to 1110215016. Use a constant ICRF power ~2.6MW from 0.5-1.5s. Keep He puff at 0.9s, 30ms duration.
Aug 22 2012 02:00:01:980PM1120822014Ken LiaoFirst shot in I-mode configuration, don't see any I-modes.
Density is creeping up during ICRF from 1 to 1.3.
Beam looks clean, but don't see any clear beam enhancement.

Try increasing the ICRF power.
Aug 22 2012 02:11:19:557PM1120822015Ken LiaoStill no I-mode. ICRF Power 3.5MW.
Density is rises the whole time.
Beam did not fire this shot.

Try increasing the ICRF power some more.
Also, adjust DNB timing to 70/30.
Aug 22 2012 02:17:57:260PM1120822016Ken LiaoICRF Power 4.3MW. H-mode occurs at 0.6. Maybe there was a I-mode immediately before, around 0.55.

Beam enhancement is not clear.

Next shot, reduce ICRF to 4MW.
Aug 22 2012 02:30:07:333PM1120822017Ken LiaoICRF Power 4.0MW. Densities are too high.

Beam enhancement is not clear.

Next shot, reduce ICRF to 4MW. Also, turn off NINJA. Drop target density to .55
Aug 22 2012 03:06:44:750PM1120822018Ken LiaoWe aren't getting a stable I-mode because density rise taking us out of I mode.
Aug 22 2012 03:08:15:140PM1120822019Ken LiaoICRF used a ramp profile to see if it would compensate for increasing density.
4-4.5MW

Beam had some faults.

Next shot, switch to ohmic shots at low density. Try 5.5.
Aug 22 2012 03:19:23:063PM1120822020Ken LiaoOhmic shot. nl04 Requested 0.55, got ~0.6.
Some decent beam modulation is visible in the CXRS data. ~6%

Next shot. Cryopump off, same density.
Aug 22 2012 04:01:13:620PM1120822021Ken LiaoEarly disruption.

Next shot. repeat. Move beam start time to 0.52
Aug 22 2012 04:06:48:200PM1120822022Ken LiaoEarly disruption
Aug 22 2012 04:06:21:470PM1120822023Ken LiaoFull length plasma. Density has some ripples from nl04 .53 - .64.
Beam starts at 0.52. Beam enhancement ~7%

Next shot: repeat. move beam start time to 0.54
Aug 22 2012 04:13:53:590PM1120822024Ken LiaoGood shot. Absolute helium intensity in CXRS data appears to be 30% larger than last shot for some reason.

Next shot, repeat, with beam start time moved to 0.56
Aug 22 2012 04:24:00:097PM1120822025Ken Liaobefore shot, torus pressure is increasing. is there a leak? RGA is showing nitrogen.

It is decreasing now.
Aug 22 2012 04:30:42:377PM1120822025Ken LiaoBeam did not fire. Sequencer problem. This happened on shot 15 as well, so something should probably be looked into.

Plasma looks ok. nl04 ~ 0.6

Try it again, same plasma settings.
Aug 22 2012 04:54:53:717PM1120822026Ken LiaoBeam only fired 5 pulses, only hitting before helium puff, so not so use
nl04 ~ 0.6

Begin density scan.

Next shot, change nl04 setpoint to .6, also change beam start time to 0.5
Aug 22 2012 05:10:05:043PM1120822027Ken Liaonl04 ~ 0.8
Good beam. Beam enhancement around 5-8%

Next shot, change nl04 setpoint to .4
Aug 22 2012 05:29:06:790PM1120822028Ken Liaonl04 set to 0.4, got ~0.58
Beam has some faults, but useable. Beam enhancement looks pretty good.

Next shot, change nl04 setpoint to 1.0
Aug 22 2012 05:51:09:573PM1120822029Ken Liaonl04 ~ 1.0
Beam enhancement is very small. It doesn't make sense to go to 1.2 at this point. Go back to 0.8, where we got decent beam enhancement.

Next shot, change nl04 setpoint to 0.8. Also change first beam pulse time to 0.52
Aug 22 2012 06:02:53:103PM1120822030Ken Liaonl04 ~ 0.8
Beam faulted on a pulse, but otherwise ok. Beam enhancement looks decent.
That's the last shot.

Physics Operator Comments
Aug 21 2012 04:41:18:293PMSteve Wolfe
Begin setup for Ken Liao's He transport experiment tomorrow.
Load from 1120821016, 0.6MA LSN. Raise nl04 to 6e19 (may need to 
go higher for EDA, but start on the ROT). Outer gap was already 
at 1.5cm, same as on the reference 1070730018, so leave RCUR at 0.66.

Set PG1 (Neon seeding, will be 3psi) from .45 to .65sec at 40%
Set PG5 (Helium) to 30msec,100V at 1.0sec

In Seg3, import from seg2 of 1120820024.
Change TF_CURRENT from 150000 to 159733.
Copy PG5 puff from seg2
Leave PG1 puff from .35 to .45 (instead of .32) since the pressure 
is higher. 

Save as 1120822000 in ~/pcs_scratch

Aug 22 2012 08:41:00:217AMSteve Wolfe
Resume setting up for MP#694
Run will probably be somewhat delayed to allow for
delivery of LHe for DNB.

Load from prepared shot ~/pcs_scratch/*pcs_1120822000 
Before doing any changes, save_as alcdata-test::/cmod/trees/test/*pcs/
1120822000, so I can examine it in iScope without having to 
redefine the paths.

First take a look at the comparison of seg2 in 1070730018
and 1120822000. There is a difference in the EF1_volt program 
at .2sec which is related to the early EF1 crowbar; also something
funny in the EF4_volt at the same time, that's probably irrelevant.
The PG1 is different, and my iScope doesn't have the PG5 in it. 
The substantive changes in the P's are 
RCUR (3mm further outin 000);
Clearin moving out earlier; 
RXL moves out by 2mm after 1sec
ZXL is 5mm higher in the 000
nl04 program is positive past 1sec in the 000
Ip does not have a bump up to 650 before dropping back to 600kA 

The RXL,ZXL changes are probably to avoid the inner corner region
which Matt thinks is the source of injections. This may result
in higher threshold though.  I can move it back toward the slot
if I need to. 

Next compare the seg3 with 1110215016, the iMode shot, and with 
1120821022, Matt's preferred target from yesterday.
Here the differences, aside from the current and TF, include
RCUR is at .66 in the iMode case and in #22, but at .657 in 000
ZCUR is at 0. after .5sec in #22, but -9mm in the others
Clearin rampdown moves in slower in #22
RXL is further in for #22, and then moves out after 1sec
ZXL is 2cm higher in #22, different early waveforms
Nl04 has slightly different early ramp in #22. 

I'm going to import_segment 2 from 1120821022 and copy the ZCUR,
RXL and ZXL traces into seg3. Leave the RCUR for now. 
Just for fun, switch to seg3 and do a build; then back to seg2
and build that too. 

Save as 1120822999 in alcdata-test, to keep something around. 
Almost forgot to adjust the pg4 in seg1. I'm assuming Sue will 
get the cryopump on, so raise pg4 from 24 to 45msec.
Ian left a substantial pg3 pre-puff before +15msec,dropping from 
100 to 50v. That may be slowing down the current rise a bit. 
I haven't checked what he was doing with seg1 voltages. The EF4
is at 1320, which I think may be too positive, but try it. 
RCUR offset=-3500 
Br_0 offset=-.001
which is the way we left it on Monday
I think he may have tweaked the rcur waveform in seg1. 
Resave this as 1120822999. I seem to have brought up pcs in safe
mode, so I can't load it from this session. 

Bring up the PCS live version
Load from 1120822999
Load into model
Load at 22-Aug-2012 08:36:48.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Notice that there is a small non-zero offset on the pg4 puff;
set it back to zero and reload. 
Load at 22-Aug-2012 08:40:08.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done


Aug 22 2012 10:27:36:533AM1120822001Steve Wolfe
Shot#1: Enable He puff from H-bottom for first shot (contrary to
what it says in the PO_Plan). 

Result: plasma full length
Got D-port RF, everything else is faulting. 
Density is high, reaches 0.9e20 with no seg2 puff.
Dalpha spike is very low, probably need more pg4
No GPC, GPC2 Te0 is ok. 

Next: raise pg4 from 45 to 50msec

Aug 22 2012 10:40:27:913AM1120822002Steve Wolfe
Shot#2:  raise pg4 from 45 to 50msec
Load at 22-Aug-2012 10:27:31.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length
Bouncy startup. Density is still high before RF
with no puff in seg2. RF gets power from D and E
J still faulting. 

Next: EF4 from 1320 to 1300
PG3 puff down in seg1



Aug 22 2012 10:55:35:307AM1120822003Steve Wolfe
Shot#3:   EF4 from 1320 to 1300
PG3 puff down to 40V from -.01 to +.015 in seg1 
Move He puff to 0.9 and reduce length to 25msec
Load at 22-Aug-2012 10:45:34.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length, density before RF is about 7e19
still no feedback puff in seg2; density rises to 1e20 with 
the RF. J still faulting, E faults after 1.2sec, D is solid.
Still a small bounce in startup, Dalpha spike is slow rise,
Zmeter spike is early, 4.5msec. 


Next: repeat, see if RF improves, density comes down some more. 


Aug 22 2012 11:06:32:113AM1120822004Steve Wolfe
Shot#4: Reduce He puff to 15msec
 see if RF improves, density comes down some more. 
Load at 22-Aug-2012 11:00:12.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length
Now SL says too little He, RF still struggling

Next: He puff to 20msec, add some pg4  

Aug 22 2012 11:25:54:527AM1120822005Steve Wolfe
Shot#5:He puff to 20msec, add some pg4 from 50 to 55msec 
 Load at 22-Aug-2012 11:08:09.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done
Amanda adjusts the GPC gratings for better coverage

Result: plasma full length
RF still struggling and still raising the density almost
a factor of 2. No H-mode. Prf bouncing between 2 and 3MW.
Still small bounces in startup, ignore it.

Next: repeat

Aug 22 2012 11:38:45:417AM1120822006Steve Wolfe
Shot#6: repeat. RF start time moved to .5sec

Result: plasma full length, possible short h-mode early in rf pulse
J does better after .9sec, but D faults out then, so total is
still low. Pre-rf target is finally down to 6e19, still only
negligible gas from feedback in seg2. 

Next: Keep repeating I guess. LBO has a cell access to adjust
CaF2 amount. 

Aug 22 2012 11:50:59:280AM1120822007Steve Wolfe
Shot#7: Keep repeating I guess. LBO has a cell access to adjust
CaF2 amount. RF will start at 0.7sec again. 

Result: plasma full length, 3 H-modes, all ELM-free
RF gets to 3MW, but still faulting, not only at the transitions
Bounce in startup is back. Still very little gas puff in seg2,
but target is down to 6e19. 

Next: Raise target nl04 to 7e19; increase again



Aug 22 2012 12:05:07:047PM1120822008Steve Wolfe
Shot#8:Raise target nl04 to 7e19; increase pg4 again from 55 to 60ms
Load at 22-Aug-2012 11:53:57.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Plasma full length, one short h-mode around 0.9sec?
Target density came up to 7e19, as programmed, but RF raises
it to 1e20 before the possible L-H. 

Next: Repeat


Aug 22 2012 12:19:08:113PM1120822009Steve Wolfe
Shot#9: Repeat
plasma full length, back to 3 h-modes very similar to 7.
Early injection took a bite out of the current at .086sec, but
it survived; up till then the startup looked good. 
RF a little better, faults around the transitions;
RF still evolving a lot of neutral pressure. 

Next: It's getting better, so we keep trying



Aug 22 2012 12:30:58:117PM1120822010Steve Wolfe
Shot#10: Repeat; next shot, consider raising ZXL to get out of the
corner, since Mo does come up during the H-modes. 

Result: plasma full length, longer first h-mode, still not
great and not steady. 

Next: raise zxl by .01


Aug 22 2012 12:46:32:923PM1120822011Steve Wolfe
Shot#11: raise zxl from -.005 to +.005,
lower ZXU by .005, leave zcur alone for now. 
Load at 22-Aug-2012 12:34:33.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length, one h-mode but not long, Prad higher
RF J is modulated after 1sec, D single faults at .89 near transition
E has a couple of faults, then steady at .9 and .7MW
Small bounce in startup

Next: increase He puff from 20 to 30msec
raise zxl another .01

Aug 22 2012 01:01:03:287PM1120822012Steve Wolfe
Shot#12: Increase h-bot from .02 to .03sec
raise zxl from .005 to +.015,
Raise zcur from -.009 to 0.
Move early rxl point from .001 to -.005
Getting close to what Matt and Ian did yesterday.
Load at 22-Aug-2012 12:52:58.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

plasma full length, h-mode lasts a little longer, still out by 1sec
Bounce on startup this time; getting bad. 
Inner strike now completely off the bottom tile, 
outer is a bit high, could move rxl in a bit more
RF still faulting, looks like the loss of rf is killing the
h-mode, not the other way around. 

Next: RXL in by -.005



Aug 22 2012 01:27:08:560PM1120822013Steve Wolfe
Shot#13: RXL in by -.005 to -.01
RF will try to raise power on D&E
Raise pg4 from 60 to 65msec
Load at 22-Aug-2012 13:08:45.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Alternator has tripped down to speed 2, with no alarms
or indications of why. This also happened 20min ago, and they
just brought it back up. Right now, it's still going down. 

Result: plasma full length
RF stays on nicely until 1.3 sec at 3.2MW, 
some injections around
0.77 and 1.1sec, no H-mode?

Next: move on to I-mode, turn on seg3, off seg2
Request TF to 175kA



Aug 22 2012 01:51:36:357PM1120822014Steve Wolfe
Shot#14  move on to I-mode, turn on seg3, off seg2
Request TF to 175kA
Move H-bot puff to .9 sec
Enable B-side lower, neon 2.8psi, from .45 to .65sec at 40%
Load at 22-Aug-2012 13:39:33.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length
Got power 2.5MW, few faults no I-mode. 
Density ramps up with no gas during RF; ratiomatic gets up to .5mTorr
Gpt neon, .13T-l from B-side lower, 2pi diode only sees 0.6MW,
no injections. 

Next: try to raise RF power


Aug 22 2012 02:04:05:740PM1120822015Steve Wolfe
Shot#15: try to raise RF power to get I-mode

Result: plasma full length, a few more neuts, but no I-mode
RF pretty steady at 3.5MW
Density still rising through rf pulse. 
2pi diode still at .65MW, not a radiation issue.

The only thing I can think of is a triangularity issue.
The main problem seems to be the uncontrolled density rise.

Next: Yijun will raise power again

Aug 22 2012 02:16:56:183PM1120822016Steve Wolfe
Shot#16:  Yijun will raise power again

Result: plasma full length; the 2pi diode is missing??
2pi foil is over 1MW
RF faulting early and late, mostly from J-port
No I-mode, looks like an H-mode early; maybe an I-mode
just before?
Density is still rising during RF in following L-mode

Try dropping RF to 4MW, find the window. 

Aug 22 2012 02:28:58:690PM1120822017Steve Wolfe
Shot#17: Try dropping RF to 4MW, find the window. 

Result: plasma full length
RF steady at 4MW, prad increasing slowly
Possible I-mode until 0.9sec, then an I->L transition? 
Density still rising during RF. 

Next: try reducing target nl04

Aug 22 2012 02:47:34:177PM1120822018Steve Wolfe
Shot#18:  try reducing target nl04from 7e19 to 5.5e19
NINJA will turn off (they were puffing at 1.4sec, 2.5T-l or so)
Load at 22-Aug-2012 14:30:58.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length, no H-mode, couple of injections 
2pi diode MIA again, foil shows a couple of smallish injections
I-mode may have lasted longer this time, but rf-induced density
rise still present. 

Next: Try ramping the RF to keep up with the density rise
Running out of patience, may try the ohmic and punt the I-mode
too. 

Aug 22 2012 03:00:55:730PM1120822019Steve Wolfe
Shot#19:   Try ramping the RF to keep up with the density rise
Running out of patience, may try the ohmic and punt the I-mode
too. 

Cryopump needs a second try, didn't get fully cold.
Frank will need a cell access after this shot. 
Meanwhile, Bill Rowan and Ken have some concern about the beam

plasma full length, one injection early in rf, 1 at 1.2sec, 
otherwise steady, neutron rate flat and not very high, 
still lose the I-mode at about 1sec

Next: move on to Ohmic L-mode case
Disable B-side lower (no more neon)

Aug 22 2012 03:18:18:863PM1120822020Steve Wolfe
Shot#20:   move on to Ohmic L-mode case
Turn off RF. 
Disable B-side lower (no more neon)
No PCS changes, keep the same equilibrium. 

Cryo not ready again. 
After this shot, turn off the cryopump and do the ohmic 
portion without it, since there's no neon and no H-modes

Result: plasma full length. Density at 6e19

Next: change pg4 for non-cryopump start,
change TF start time from -1. to -1.1 sec (per Bergerson request)

Aug 22 2012 03:33:27:393PM1120822021Steve Wolfe
Shot#21:  chamge pg4 for non-cryopump start, from 65msec to 22msec
change TF start time from -1. to -1.1 sec (per Bergerson request),
in pcs and engineering start time
Load at 22-Aug-2012 15:24:57.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Base pressure at 3.0e-6 before INIT,
hopefully the cryo isn't going to leave a lot of crap around
now that it's off. 
 
Result: plasma disrupted at .31sec,
had an early bounce, maybe some runaways. 

Next: increase pg4 from 22 to 24msec

Aug 22 2012 03:43:57:103PM1120822022Steve Wolfe
Shot#22: increase pg4 from 22 to 24msec,
it was only at 800kA when it disrupted, assume it will 
still need a little more gas, even after the disruption.

IGT=2.8e-6 at INIT
Result: same disruption
startup was ok
Maybe a locked mode, try increasing the density before .5sec


Aug 22 2012 04:00:27:320PM1120822023Steve Wolfe
Shot#23: Raise target nl04 to 7e19 at .3sec, down to 
6e19 at .5sec and flat to EOF
Put back some pg3 in seg1, 25 to 20V at .1sec
Load at 22-Aug-2012 15:52:14.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length
nl04=6e19, with some wobbles
Startup good, small early injection .13sec, some
early runaways, not bad. It touches at crossover, not sure
how that's changed.

Next: Try to repeat 



Aug 22 2012 04:13:49:533PM1120822024Steve Wolfe
Shot#24:Try to repeat, no PCS changes

Result: plasma full length 
density looks good. Early runaways are a little bigger,
not sure where they come from, there's no sign of a bounce.
Ken is seeing a change in the He signal, there was no change
in the puff from H-bot 

Next: repeat that again


Aug 22 2012 04:27:20:767PM1120822025Steve Wolfe
Shot#25:Try to repeat, no PCS changes
Nitrogen leak after Ron shut down the cryopump
brought the vessel pressure up to 6.5e-6 briefly, 
back down below 3e-6 at INIT, 2.3e-6 in CHECK

Result: plasma full length
No beam this shot

Next: repeat it again


Aug 22 2012 04:50:10:130PM1120822026Steve Wolfe
Shot#26: repeat it again
Getting another nitrogen leak between shots,
up to 5.2e-6 then back down, I hope. Slowing down the
TF cooling, since that may be what's causing it. 
N leak coming back up, above 8e-6; pump is off, but vessel
went back down to 20C. 
Vessel up to 24C, IGT down to 2.3e-6; 1.9e-6 in CHECK

Result: plasma full length, had injections at .3 and .5sec
not sure where they came from. 

Next: Raise nl04 to 8e19

Aug 22 2012 05:10:03:057PM1120822027Steve Wolfe
Shot#27: Raise nl04 from 6 to 8e19
Raise pg4 from 24 to 25ms

Something went berserk in my PCS session. 
Acted like a key stuck down problem. 
Loaded five or six times before I made the pg4 change
 Load at 22-Aug-2012 16:57:43.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

And we've got another leak and the vessel is down to 20C
again. 

Result: plasma full length, small injection at .5sec, 
got 8e19, as programmed. 
startup still good. 

Next: move f.d. off gate to 1.8sec, stop running more TF than
we need. Drop nl04 down to 4e-5 after 0.5sec 


Aug 22 2012 05:29:33:240PM1120822028Steve Wolfe
Shot#28: move f.d. off gate to 1.8sec, stop running more TF than
we need. Drop nl04 down to 4e-5 after 0.5sec 
Load at 22-Aug-2012 17:11:35.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Had to wait for another cooling-related link,
Started INIT at 1.9e-6, doing the cooling one quadrant at a time

Result: plasma full length, density only down to 5 or 6e19

Next: Raise nl04 to 1.0e20




Aug 22 2012 05:47:32:903PM1120822029Steve Wolfe
Shot#29:Raise nl04 to 1.0e20
Load at 22-Aug-2012 17:30:04.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Still fighting the LN2 leak. It is clearly correlated with the
TF quadrant cooling coming on. Have to live with it for the
rest of the day, only a couple shots left anyway. 
Waiting for IGT to come back down to 3.0e-6
and now we have I2t invalid; had to reset relays and wait another
few minutes. 

Result: plasma full length, nl04 to 1e20, nice and flat

Next (and last): Back to 8e19 




Aug 22 2012 06:02:05:693PM1120822030Steve Wolfe
Shot#30: Back to 8e19 
Load at 22-Aug-2012 17:49:19.00
Open tree /home/wolfe/pcs_scratch      -1
Open tree done

Result: plasma full length
nl04=8e19, got beam, looks ok.

End of run



Engineering Operator Comments
ShotTimeTypeStatusComment
110:17:34:813AMPlasmaOk
210:34:08:683AMPlasmaOk
310:48:57:673AMPlasmaOk
411:02:20:393AMPlasmaOk
511:16:04:833AMPlasmaOk
611:29:33:013AMPlasmaOk
711:43:16:467AMPlasmaOk
811:57:00:577AMPlasmaOk
912:10:33:120PMPlasmaOk
1012:25:00:660PMPlasmaOk
1112:39:27:270PMPlasmaOk
1212:53:50:127PMPlasmaOk
1301:19:28:303PMPlasmaOk
1401:40:19:573PMPlasmaOk
1501:53:01:780PMPlasmaOk
1602:08:33:767PMPlasmaOk
1702:22:02:653PMPlasmaOk
1802:35:31:407PMPlasmaOk
1902:55:41:590PMPlasmaOk
2003:14:17:580PMPlasmaOk
2103:27:43:613PMPlasmaOk
2203:40:14:313PMPlasmaOk
2303:52:40:760PMPlasmaOk
2404:06:12:507PMPlasmaOk
2504:24:57:130PMPlasmaOk
2604:46:09:273PMPlasmaOk
2705:04:18:067PMPlasmaOk
2805:23:27:380PMPlasmaOk
2905:43:01:297PMPlasmaOk
3005:58:38:070PMPlasmaOk

System Availability
Aug 22 2012 10:17:16:443AM
SystemAvailableCommentAvailability
Changed
OwnerDescriptionWho Can
Change
Active MHDnosecured - tagged outJun 2 2008 11:03:58:433AM (sears)Joe SnipesActive MHD Antennagolfit
BESyesBES system is onlineNov 22 2011 02:21:12:050PM (bespam)Bill RowanBeam Emission Spectroscopybespam,liao,rowan
BolometersyesMidplane diodes functioning properly. Midplane bolometers working and calibrated. DIV bolometers installed but not yet toaster calibratedApr 20 2012 09:57:29:520AM (mlreinke)Matt ReinkeBolometershutch,mlreinke
Boronizationyes Jun 15 2012 05:02:46:313PM (dekow)Jim IrbyBoronizationdekow,irby
CECEyesThe system is currently operational for Te tilde measurement. Talk to Choongki about the current configuration Jul 3 2012 04:38:00:317PM (nthoward)Anne WhiteCorrelation ECEnthoward,sck83,whitea
CNPAyesMultiple channel CNPA available, no safety risk for in-vessel accessApr 14 2011 12:01:59:693PM (parker)Ron ParkerCompact Neutral Analyzerparker
Cryopump - Upper Divertoryes Jun 15 2012 05:02:31:550PM (dekow)Brian LaBombardUpper Divertor Cryopumpdekow,irby,labombard
CXRSyescore-CXRS system is onlineNov 22 2011 02:21:22:280PM (bespam)Bill RowanCharge Exchange Spectroscopybespam,blip,liao,rachmcd,rowan
CXRS edgeyesMichael CHurchill has primary responsibility at the momentApr 19 2011 11:44:46:247AM (blip)Bruce LipshultzMeasurement of CXR light in the pedestal region at both the high- and low-field sidesblip,rmchurch
D Alphayes\ha2_bright is available; \SPECTROSCOPY::TOP.VUV.VIS_SIGNALS:MCP_VIS_SIG1 is not availableJul 1 2009 09:45:41:090AM (terry)Jim TerryBalmer Alpha Monitorirby,terry,wolfe
Dalsanosystem is is installed and aligned, but not functional (appears to be a broken cable)Dec 5 2011 02:41:42:867PM (marmar)Earl MarmarVisible Bremsstrahlung Imagingmarmar
Disruption Mitigationyestwo gas jet valves active as of Feb 2012May 15 2012 10:09:23:597AM (granetz)Robert GranetzGas Jetgranetz,whyte
Divertor IRno Mar 6 2007 10:50:41:677AM Glen WurdenDivertor IR Digital Videogwurden,terry
Divertor IR Spectroscopyno Mar 6 2007 10:51:39:897AM Glen WurdenDivertor IR Spectroscopygwurden,terry
DMBolo AXUV diodesyesDiodes are taking usable data. Not all post-processing code is working yet.Feb 1 2012 01:24:23:953PM (golynyk)Geoff OlynykSet of six AXUV diodes in a toroidal array of midplane wall boxes.golynyk,granetz,mlreinke,whyte
DNByes"The beam could break at any moment."May 15 2012 10:09:52:470AM (granetz)Robert GranetzDiagnostic Neutral Beamdterry,granetz,mochung
ECDCyes Apr 26 2012 03:23:19:057PM (dekow)Jim Irby2.45 GHz, 3 kW, discharge cleaning systemdekow,irby,pfeiffer
FRC-ECEyesFRC-ECE is onlineMay 14 2012 11:53:01:693AM (bespam)Perry PhillipsHeterodyne ECE-32 channelsbespam,liao,phillips,rowan,whitea
FTCIyesSystem OperationalMay 14 2012 11:50:45:590AM (irby)Jim IrbyFast two-color interferometerirby
G-Side RatiomaticyesInstalled April 25,2012. New controller installed 5/29/2012Jun 7 2012 10:40:00:957AM (toland)Brian LaBombardG-side ratiomatic ionization gaugelabombard,toland
Glow DischargenoHV cables disconnected and power supplies off. Electrical plugs have been disconnected, capped and red tagged.Mar 5 2012 10:21:53:460AM (dekow)Jim Irby1 kV, 5 A, glow discharge systemdekow,dterry,irby
GPCyesOperationalApr 27 2012 07:41:46:907AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPC2yesOperationalApr 27 2012 07:42:03:317AM (hubbard)Amanda HubbardECE Polychromaterhubbard
GPIyesThe Xpt-view, the midplane-view cameras are operational. The innerwall GPI (coupled to the fast-diodes) is available. Jul 1 2009 09:45:50:933AM (terry)Jim TerryGas Puff Imagingterry,zweben
H/Dyessystem is functional and taking dataDec 5 2011 02:42:29:857PM (marmar)Earl MarmarH/D Ratiomarmar
HEATyes Apr 26 2012 03:23:49:607PM (dekow)Gary Dekow - Machine Heaters -burke,dekow
Hirex JryesHirex-Jr has been installedJun 28 2010 03:36:33:420PM (rice)John RiceHigh Resolution X-Rayince,rice
Hirex SryesInstalled and aligned. Will be available for Ti/Vr profiles after focusing tests and locked modes are taken.Dec 6 2011 08:21:02:453AM (ypodpaly)John RiceHigh Resolution X-Raycgao,ldelgado,rice,ypodpaly
HXRyes32 Channels operational,, no safety risk for in-vessel accessApr 14 2011 12:05:24:810PM (parker)Ron ParkerHard X-Ray Arrayfaust,parker,schmidt
ICRF D-Antennayes May 31 2012 09:20:06:827AM (wukitch)Steve WukitchD-port antennawukitch,ylin
ICRF E-Antennayes May 31 2012 09:19:57:640AM (wukitch)Steve WukitchE-port antennawukitch,ylin
ICRF J-Antennayes May 31 2012 09:19:47:443AM (wukitch)Steve WukitchJ-port antennawukitch,ylin
Impurity SpectroscopyyesBeing upgraded with better optics and new spectrographs. Dan Miller has primary responsibility.Apr 19 2011 11:46:02:193AM (blip)Bruce LipshultzMeasurement of recycling light and impurity source rates at multiple surfaces around the tokamakblip,miller
Laser Blow-OffyesPumped Down, Laser has not yet been tested but otherwise operationalMay 14 2012 04:31:17:037PM (nthoward)Martin GreenwaldImpurity Injection Systemg,nthoward
Lower HybridyesLH is now available for plasma operation up to ~900 kW net power.Jul 3 2012 02:50:00:693PM (wallaceg)Ron ParkerLower Hybriddterry,parker,wallaceg
Lower Hybrid ReflectometernooffApr 15 2011 08:24:27:930AM (dominguez)Arturo DominguezLower Hybrid Reflectometerdominguez,marmar,parker,sgbaek
LoWEUSyesLoWEUS viewing the 10-30 nm region, spectral brightness vs. lambda and time are being stored in tree.Apr 20 2012 10:43:34:077AM (mlreinke)Matthew L. Reinke Long Wavelength Extreme Ultraviolet Spectrometermarkchil,mlreinke
LPInoBeam line removedMay 30 2008 02:09:12:833PM (bose)Earl MarmarLithium Pellet Injectorbose,marmar
Ly-alphanoMidplane Lyman-a not functioning. New B-PORT Lyman (BPLY) still being debugged.Jul 12 2012 08:52:28:233AM (mlreinke)Matt ReinkeLyman alpha camerasfaustian,labombard,mlreinke
Magneticsyes Dec 1 2011 11:51:51:970AM (g)Robert GranetzBp coils and flux loops for equilibrium controlgranetz,wolfe
McPhersonnoMcPherson under vacuum but is not run on a day-to-day basis. Can be requested if desired. LoWEUS has taken over as the primary Mo monitor.Jul 12 2012 08:53:14:937AM (mlreinke)Jim TerryVUV Spectrometermarkchil,mlreinke,terry
MichelsonyesVacuum 3-4e-8 T. Starting with Michelson at reduced speed.Apr 27 2012 07:42:41:960AM (hubbard)Amanda HubbardECE Te Profileshubbard,schmidt
MKSyes Dec 2 2011 12:27:47:163PM (toland)Brian LaBombardBaratron pressure gaugeslabombard,toland
MLPyesOperational. Connected to A-port probe systemMay 10 2012 08:40:19:910AM (labombard)Brian LaBombardMirror Langmuir Probe Electronics Systemlabombard
MSEyes2/29/2012 MSE operational. No HV or vacuum safety issuesFeb 29 2012 12:26:13:863PM (sscott)Steve ScottMotional Stark Effectjinseok,sscott
NeutronsyesVoltage is on for He3 detectors on J port. Remaining voltages will be turned on for the first run.Apr 23 2012 09:31:22:063AM (fiore)Catherine FioreNeutron Detectorsfiore
Neuts and HardsyesAll detectors Powered On --- Waiting for neutrons for calibrationNov 22 2011 01:05:24:380PM (irby)Jim IrbyX-Ray/Neutron Detectors at K-Horirby
NINJAyesC-bottom and new F-bottom system ready.Dec 2 2011 12:28:44:843PM (toland)Brian LaBombardNINJA gas pufflabombard,terry,toland
PCIyesOperational.Jul 10 2012 07:08:06:883PM (ntsujii)Miklos PorkolabPhase Contrast Imagingemd,ennever,ntsujii,porkolab
Penning GaugesyesHV power supplies turned ON in INIT, off in RECOOLMay 10 2012 08:41:03:000AM (labombard)Brian LaBombardPenning Ionization Gaugeslabombard
Plasma TVyesWIDE1, WIDE2 (chan 33), DANT, JANT and DIV are operational.Jul 1 2009 09:46:29:543AM (terry)Jim TerryVideo of plasma via several camerasdekow,irby,terry,wolfe
Polarimeteryes3 chords operational but with high noise levelJan 6 2012 04:22:20:903PM (irby)Jim IrbyC-Mod Polarimeterirby
Power - Alternator Air Switchyes Apr 26 2012 03:24:21:607PM (dekow)Gary DekowAlternator to Power Room Power Supply Connectioncochran,dekow,dterry,irby
Power - PEIyes Apr 26 2012 03:24:41:250PM (dekow)Gary DekowPEI Systemcochran,dekow,dterry,irby
Power - TMXyes Apr 26 2012 03:24:57:153PM (dekow)Gary DekowEf2s,. EFCs and A-Coilsbyford,cochran,dekow,dterry,irby
Power Systemsyes Apr 26 2012 03:25:14:497PM (dekow)Jim IrbyC-Mod Magnet Suppliesbyford,cochran,dekow,dterry,irby
Probe Array - ISDyesOperational. Some dead probes.May 10 2012 08:41:58:120AM (labombard)Brian LabombardInner Lower Divertor Probe Arraylabombard
Probe Array - LHyesOperational. 4 out of 6 probes working.May 10 2012 08:41:40:557AM (labombard)Brian LaBombardLower Hybrid Probe Arraylabombard
Probe Array - OSDyesOperational.May 10 2012 08:42:13:733AM (labombard)Brian LaBombardOuter Lower Divertor Probe Array (F and J)labombard
Probe Array - UDIVyesOperational. Some dead probes.May 10 2012 08:42:32:663AM (labombard)Brian LaBombardUpper Divertor Probe Arraylabombard
ReflectometeryesOn 1120608, the high frequency channels: 112, 140 and the variable, have been disconnected for some troubleshooting. All other channels are connectedJun 14 2012 11:28:59:603AM (dominguez)Earl MarmarReflectometerdominguez,marmar
Scanning Probe - ASPyesOperational. A variety of probe heads are ready for use.May 10 2012 08:43:10:937AM (labombard)Brian LaBombardA-Port Scanning Probelabombard
Scanning Probe - FSPyesOperational.May 10 2012 08:43:24:887AM (labombard)Brian LaBombardF-Port Scanning Probelabombard
Scanning Probe - WASPnoNot functioning. Probe tips are melted. Repair not performed during break.May 10 2012 08:44:43:137AM (labombard)Brian LaBombardInner Wall Scanning Probelabombard,nsmick
Shoelace AntennayesOperationalMay 10 2012 08:45:08:320AM (labombard)Brian LaBombardHigh-k active MHD antenna, for QCM, WCM studiesgolfit,labombard
SOL reflectometeryesc-port (top, middle, bottom) and h-port available. Only 1 of 4 locations can be used for each dischargeMay 1 2012 04:54:58:820PM (cornwall)Cornwall LauSOL reflectometercornwall,wukitch,ylin
SparkeryesSparker Power Supply powered up. Connected at K port using red cable 4/23/12 9:25AMApr 23 2012 12:06:10:983PM (parkin)Jim IrbyField Emission Preionization for C-Moddekow,irby,parkin
Surface Science StationyesSSS is under vacuum and fully available.Jul 3 2012 02:46:59:753PM (ochoukov)Bruce LipschultzRadially scanning probe located on K-portblip,ochoukov
TCIyesTCI lasers in operation May 14 2012 11:51:18:700AM (irby)Jim IrbyTwo-Color Interferometerirby,murray
TS - CoreyesOperating with both lasers, density calibration ongoing.Jul 19 2012 10:20:09:220AM (jrwalk)Jerry HughesCore Thomson scatteringjrwalk,jwhughes,yma
TS - EdgeyesOperating with both lasers, density calibration ongoing.Jul 19 2012 10:20:28:323AM (jrwalk)Jerry HughesMillimeter resolution edge Thomson scatteringjrwalk,jwhughes,yma
Vispecno350 and 670 nm, 4 spatial channelsNov 28 2007 09:58:35:493AM (agraf)Alex GrafVisible Spectrometeragraf
XEUSyesXEUS viewing the 1-6 nm region, spectral brightness vs. lambda and time are being stored in tree.Apr 20 2012 10:43:43:107AM (mlreinke)Matt ReinkeX-ray Extended Ultraviolet Spectrometermarkchil,mlreinke
XTOMOyesARRAY1->5 available. Specific channels on various arrays display issues.Apr 20 2012 05:36:28:523PM (faustian)Robert GranetzX-Ray Tomographyfaustian,granetz,mlreinke