| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Steve Horne |
| Physics operator(s): | Ian Hutchinson |
| Engineering operator(s): | Unknown |
| Engineering Operator Run Comment |
| Power Supply Tests |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Physics Operator Summaries |
| Session Leader Comments | |||
| May 1 1993 08:21:55:790AM | Ian Hutchinson | Some games with the hybrid wavegen.
OH2 rogowski discovered to be broken by foot! | |
| May 1 1993 09:08:59:400AM | Ian Hutchinson | Some initial tests were able to get OH2 going. Shot counter was reset to 1.
Search completed around 9:10. Took rather a long time. Should concentrate on getting a good routine for this. | |
| May 1 1993 10:24:43:910AM | Ian Hutchinson | Some initial tests were able to get OH2 going. Shot counter was reset to 1.
Search completed around 9:10. Took rather a long time. Should concentrate on getting a good routine for this. | |
| May 1 1993 10:34:55:820AM | Ian Hutchinson | Shot 3 asked for 5 kA. The consensus of the shunts and the internal
magnetics is that we got around 8 kA. This scaled correctly from the previous (3.2 from 2 requested.) Hybrid is not ready so we are moving on to EF3. | |
| May 1 1993 09:56:17:370AM | 930501002 | Steve Horne | For shot 2, notice that
OH2 U buss shunt reading is - 3200 L + 3500 But OH2 Buss rog U reads + 1100 L -1900 Some of these are wrong. |
| May 1 1993 11:17:11:550AM | 930501004 | Steve Horne | puzzling shot. We tried to fire ef4. Possibly fired EF3 instead.
EF3 was left on, set to zero. Fired at some low level. (400 A?) EF4 didn't fire, probably. |
| May 1 1993 11:20:53:990AM | 930501004 | Steve Horne | Plan for next shot -- EF3 really really off, oh2 off, ef4 demand to 2 KA
|
| May 1 1993 01:24:50:410PM | 930501007 | Steve Horne | OH2 commutation -- one fixed, on not
Gwinn, Silva worked on EF3. ef4 problem being worked on -- bad 24 volt supply OH1 -- reconnected Rogowski Installed "bell" on buss. Replaced AFOL rcvr for oh2 u,l with the one from the chopper. Plan for next shot -- commutate oh2u,l (at least one won't work) and verify programming of oh2 to digitizer. Under PLC control. |
| May 1 1993 02:18:10:180PM | 930501010 | Steve Horne | EF4 current in wrong direction.
ef2 U rog is backwards Next shot plan -- 2 KA on EF3 only. |
| May 1 1993 03:24:45:980PM | 930501012 | Steve Horne | Try v programming for ef3. It worked.
|
| May 1 1993 03:25:40:650PM | 930501014 | Steve Horne | Last shot had feedback on ef3 rogowski, showing correct behavior at gain=1 on pid.
Next shot has pid gain=5. |
| May 1 1993 03:41:56:150PM | 930501014 | Steve Horne | Last shot had feedback on ef3 rogowski, showing correct behavior at gain=1 on pid.
Next shot has pid gain=5. That worked. |
| May 1 1993 03:43:59:860PM | 930501015 | Steve Horne | This shot (15) has drawn current in ef3 for more time (100 msec or so)
and a small pedestal on the current regulation. |
| May 1 1993 04:06:35:780PM | 930501015 | Steve Horne | This shot (15) has drawn current in ef3 for more time (100 msec or so)
and a small pedestal on the current regulation. That tried to work For next shot changed ef3 voltage programming. |
| May 1 1993 04:10:41:920PM | 930501015 | Steve Horne | For this shot (17) try OH1 plc control, 15 ka demand,commutation.
ef3 current feedback, -1500 A |
| May 1 1993 04:23:59:470PM | 930501017 | Steve Horne | For this shot (17) try OH1 plc control, 15 ka demand,commutation.
ef3 current feedback, -1500 A That was real complicated. Try less voltage and more gain on ef3. |
| May 1 1993 04:52:00:440PM | 930501018 | Steve Horne | For this shot (17) try OH1 plc control, 15 ka demand,commutation.
ef3 current feedback, -1500 A That was real complicated. Try less voltage and more gain on ef3. |
| May 1 1993 04:57:26:960PM | 930501018 | Steve Horne | Add 1 unit derivative gain to ef3 and pray.
tf again, same as last shot |
| May 1 1993 05:09:48:820PM | 930501018 | Steve Horne | Add 1 unit derivative gain to ef3 and pray.
tf again, same as last shot EF3 didn't run at all. |
| Physics Operator Comments |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:24:26:480AM | Test | Bad | OH2 jorway trigger and camac trigger switched |
| 2 | 09:41:26:550AM | Test | Ok | both oh2 fired; calibration errors |
| 3 | 10:15:51:020AM | Test | Ok | Both power supplies worked; checking calibration of rogowskis |
| 4 | 10:59:06:860AM | Test | Bad | EF3 fired accidentally! EF4 did not fire as intended |
| 5 | 11:23:28:640AM | Test | Bad | No EF4 |
| 6 | 11:31:07:170AM | Test | Bad | No EF4 |
| 7 | 11:39:18:450AM | Test | Bad | looks ,like I/O processor fault |
| 8 | 01:36:28:740PM | Test | Bad | OH2 switch did not close; we had opened cabinet doors |
| 9 | 01:56:37:620PM | Test | Ok | Both OH2 at 8 ka |
| 10 | 02:05:52:550PM | Test | Ok | 9 power supplies at once: 2 OH2, 4 EF2, 3 EF4, all OK |
| 11 | 02:22:55:060PM | Test | Ok | EF3 test; program 2 kA, got about 1.3 kA |
| 12 | 02:34:00:600PM | Test | Ok | EF3; set for 6000, got 5000, OK |
| 13 | 02:53:50:300PM | Test | Ok | EF3 under hybrid control; works OK i |
| 14 | 03:13:24:200PM | Test | Ok | EF3 Test under hybrid control |
| 15 | 03:30:28:190PM | Test | Ok | EF3 and both EF1 closed circuit |
| 16 | 03:43:21:300PM | Test | Ok | EF1 and EF3; EF1 did commutate OK with no fault |
| 17 | 04:12:05:590PM | Test | Ok | OH1 commutation & EF3 hybrid |
| 18 | 04:41:33:320PM | Test | Ok | OH1 plus first TF test; crowbar at 30 kA |
| 19 | 05:00:58:520PM | Test | Ok | last shot; TF crowbar, no ef3, cause unknown |
| 20 | 04:36:42:140PM | Test | Bad | |