Alcator C-Mod Run 930602 Information

Back to runs

Miniproposals
Miniproposal:
Date Filed:
Title:
First Author:
Session Leader:John Rice (shots 1-26)

Operators
Session leader(s):John Rice
Physics operator(s):Robert Granetz
Engineering operator(s):Joe Daigle,David Gwinn

Engineering Operator Run Comment
Plasma run.

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:07:493PM
Author: To Be Determined
Summary of Run 930602
Session Leader/Physics Operator: Granetz
Assistant Physics Operator: Rice
Engineering Operator: Daigle/Gwinn

-------------------------------------------------------------------------------

Overview:

The two principal purposes of today's run were intended to be:

1) Try new predictors for R_CUR and Z_CUR. These have been recalculated by
Steve Wolfe using lower weightings on the vessel filaments relative to the
plasma filaments, and larger sigmas on the Bp coils.

2) Investigate the tendency of the plasma to become disruptive when it is
pulled off the inboard wall. (Examine 2-pi and array bolometers, H-alpha
emission from inner wall, molybdenum content, x-rays (sawteeth/disruptions),
hard x-rays, and especially density.

Unfortunately the shot quality and reproducibility was dismally poor,
and we did not get good enough plasmas to begin looking at item (2).
However, we did get to test the new position predictors (item 1), and
found that they worked significantly better than the old predictors.
These new ones have now become the working predictors.

-------------------------------------------------------------------------------

Prior to run:

This is the first run after a holiday weekend (i.e. today is Wed, last run was
last Thursday). ECDC was done on Sat and Sun, resulting in some cleanup
according to the RGA (if it can be trusted). Base pressure is in the mid
10^-7 torr range.

Another important change: the RF limiter has been moved in from R=0.919 to
R=0.900 m.

-------------------------------------------------------------------------------

Detailed summary:

The power supply programming for the start of the run was copied from
shot 930527032 from last week. This was a long (>0.3 s) discharge on the
inboard wall. The run was held up for over an hour due to a problem with
the bitbus communication to the hybrid. This problem was overcome, but
the cause is still not understood. The first shot experienced a failure of
hybrid control, and part of this problem was a dead power supply on the AFOL's
from the bus rogowskis. After this was fixed, we began a disappointing day
of mostly `fizzles' (short breakdowns) and `no breakdown' shots. Even though
we started by copying a particular shot from last week, we never were able
to come close to reproducing it. Most of the day was spent doing minor
`tweaks' of the vacuum fields to slighly improve the vacuum null at
breakdown. As usual, the machine repeatibility from shot to shot was not
very good. In addition, using the new, greatly improved R_CUR and Z_CUR
predictors, we experimented with feedback control of the plasma current
centroid. I would say that our gain on Z_CUR was too high, resulting in
some oscillation of the z-centroid as seen by the x-rays. Control of the
R-centroid was not clearly demonstrated.

We also played around a little with the pre-fill gas pressure, as well
as the pulse gas programming. We had one shot (930602008) that obviously
was dominated by runaways, most likely due to insufficient pulsed gas.
This was presumably due to a large change in the threshold offset of the
piezo valve which was effected sometime during the past weekend.
Re-programming the pulse gas voltage control eliminated this problem.

All-in-all, it was a pretty disappointing day, with the exception of the
successful tests of the new position predictors.

Note: all the power supplies worked flawlessly today. Kudos to our
engineering and technical staff.
-------------------------------------------------------------------------------

Shot statistics:

Total shots: 26

No breakdowns: 8 (only 1 due to failure of hardware)

Fizzles (i.e. < 0.15 MA): 9

Plasmas (i.e. > 0.15 MA): 9 (max Ip=0.34 MA, max disruption-free
period=0.10 s)

-------------------------------------------------------------------------------

Suggestions/comments for next run:

Start from a shot last week that was not so marginal with respect to
getting a breakdown.

Reduce the gain on the Z_CUR feedback control.

Physics Operator Summaries

Session Leader Comments
Jun 2 1993 08:29:21:990AMRobert GranetzSession leader: Granetz
Assistant: Rice
Engineering: Gwinn/Daigle

Purposes of run:

1) Investigate the tendency of the plasma to become disruptive when it is
pulled off the inboard wall. (Examine 2-pi and array bolometers, H-alpha
emission from inner wall, molybdenum content, x-rays (sawteeth/disruptions),
hard x-rays, and especially density.

2) Try new predictors for R_CUR and Z_CUR. These have been recalculated by
Steve Wolfe using lower weightings on the vessel filaments relative to the
plasma filaments, and larger sigmas on the Bp coils.

3) If time permits, try playing with the R_CUR controller (maybe add EF4 into
the soup).

Jun 2 1993 08:29:44:890AMRobert GranetzImportant happenings since last run:

This is the first run after a holiday weekend (i.e. today is Wed, last run was
last Thursday). ECDC was done on Sat and Sun, resulting in some cleanup
according to the RGA (if it can be trusted). Base pressure is in the mid
10^-7 torr range.

Another important change: the RF limiter has been moved in from R=0.919 to
R=0.900 m.

Power Supply settings (on/off times, commutation resistors, PLC current
limits, etc) will be the same as the last shot, 930527032.

We will start with the last plasma shot, 930527032, which was a long (>0.3 s)
discharge on the inboard wall.

Jun 2 1993 10:43:45:440AM930602001Robert GranetzThis shot has been delayed by about 1.5 hours due to a problem loading the
hybrid over the bitbus. Steve Horne, Josh Stillerman, and Tom Fredian are
working on it. Manual "init"ing has enabled us to try for the first shot.

Jun 2 1993 10:46:14:150AM930602001Robert GranetzNo OH1. All other supplies just ran up to their PLC limits and railed until
commutation. Oh yes, no plasma. The real-time storage scopes also did not
get any signals. There still seems to be a problem with communication
to/from the hybrid...possibly due to some new AFOL's.

Jun 2 1993 10:47:23:840AM930602001John RiceBit bus errors on hybrid have delayed the first shot.

No flash.

No OH1

Jun 2 1993 11:03:04:180AM930602001Robert GranetzThe 5 volt power for the AFOL's on the bus rogowskis was dead. It has been
replaced.

Jun 2 1993 11:10:30:730AM930602002Robert GranetzFizzle. Gas pre-fill was at 6e-5 torr. Change to 5e-5 for next shot.

Jun 2 1993 11:10:31:930AM930602002John RiceFlash, no current rise. CIII filter now on TV picture
Fill pressure 6 e-5 T

Jun 2 1993 11:27:22:620AM930602003Robert GranetzFizzle again. Bz & Br okay. dBz/dR slightly negative. Adjust using 200 amps
more in OH1 for next shot. Pulsed gas programming also was lowered for the
next shot to account for recently changed voltage offset of the piezo.

Jun 2 1993 11:38:52:030AM930602004Robert GranetzFizzled again. Adjust Bz using EF4 for next shot (increase EF4 by 60 amps)

Jun 2 1993 11:59:16:850AM930602005Robert GranetzAnother fizzle.

Jun 2 1993 11:59:33:760AM930602006Robert GranetzAnother fizzle.

Jun 2 1993 12:25:09:820PM930602007Robert GranetzAnother fizzle

Jun 2 1993 12:31:19:610PM930602008John Rice330 kA Ip. No pulsed gas? Lots of hard x-rays, also on softs.
Hard x-ray gain changed.

Jun 2 1993 12:56:54:560PM930602009John RicePulsed gas increased by 30 V, fill pressure changed to 6 e-5 T.

Flash only

Jun 2 1993 12:57:07:170PM930602009Robert GranetzFizzled. Pre-fill was raised from 5 to 6e-5 and pulsed gas valve programming
was increased by about 15 volts.

Jun 2 1993 01:23:03:240PM930602010Robert GranetzIp=0.155 MA. single disruption at 0.078 s ends the shot. Plasma moved downward by 10 cm
as the shot progressed. The new predictors seemed to do much better than
the ones presently being used for position control. For the next shot

Jun 2 1993 01:42:44:110PM930602010Robert GranetzFor the next shot, load in the new Z_CUR predictor on the actual control
wire.

Jun 2 1993 01:31:51:490PM930602011Robert GranetzSimilar, but not identical to the previous shot. Ipmax=0.2 MA. Shot ends
with a single disruption at 0.073 s. Plasma starts moving downward, then
is forced back up, then dives downward. Simultaneously it is moving
inwards.

Jun 2 1993 01:41:40:690PM930602011Robert GranetzFor the next shot, put in the new R_CUR predictor also.

Jun 2 1993 01:51:35:630PM930602012Robert GranetzSlightly shorter duration. Ipmax=0.2 MA. Single disruption at 0.064 s ends
the shot. Vertical position is lost after about 0.050 s

Jun 2 1993 02:09:48:660PM930602013Robert GranetzNo breakdown! I don't think it's anything we did.

Jun 2 1993 02:31:36:520PM930602014Robert GranetzCarbon copy of shot #012

Jun 2 1993 04:02:36:790PM930602015Robert GranetzNo breakdown

Jun 4 1993 04:21:41:130PM930602015Steve Golovatoshot 930604015.
fizzled again.


Jun 2 1993 04:01:47:220PM930602016Robert GranetzIpmax=0.25 MA. Shot lasted to 0.10 s. Plasma position feedback is definitely
trying to do something.

Jun 2 1993 03:10:41:400PM930602017Robert GranetzNo breakdown

Jun 2 1993 03:18:04:350PM930602018Robert GranetzNo breakdown

Jun 2 1993 03:35:12:650PM930602019Robert GranetzIp=0.2 MA, ends at 0.073 s.

Jun 2 1993 03:57:42:630PM930602020Robert GranetzNo breakdown

Jun 2 1993 03:57:48:200PM930602021Robert GranetzNo breakdown

Jun 2 1993 04:26:24:900PM930602022Robert GranetzNo breakdown again. Fix EF3 leading "porch" to get rid of extra vertical
field at t=0 for the next shot. Also raise fill pressure to 8e-5 torr for
the next shot.

Jun 2 1993 04:38:46:740PM930602023Robert GranetzFizzle. For next shot: tweak EF3 "front porch" amplitude less by another
50 amps, and decrease EF4 by 50 amps.

Jun 2 1993 04:45:18:030PM930602024Robert GranetzIp=150 kA, duration=0.077 s. Sawteeth.

Jun 2 1993 04:52:16:130PM930602024Robert GranetzFor the next shot, increase PID gain of R_CUR feedback from 0.1 to 0.25

Jun 2 1993 04:57:01:040PM930602025Robert GranetzFizzle

Jun 2 1993 05:16:35:940PM930602026Robert GranetzBest shot of day, but that's not saying much. Ipmax=0.15 MA. Duration=0.117 s
Briefly sawtooths. Becomes disruptive late in the shot. Vertical position
is very good, but in/out position moves toward inside starting when the
feedback turns on at 0.050 s.

Physics Operator Comments

Engineering Operator Comments
ShotTimeTypeStatusComment
109:32:30:930AMPlasmaBadef1/oh2 com fail - no hybrid control
211:02:36:400AMPlasmaOkPlasma shot no faults
311:11:28:140AMPlasmaOkPlasma shot no faults.
411:28:25:970AMPlasmaOkGood plasma shot
511:42:13:060AMPlasmaOkPlasma shot no faults.
611:54:05:250AMPlasmaOkGood Plasma shot no faults.
712:09:51:990PMPlasmaOkPlasma shot no faults.
812:21:14:590PMPlasmaOkplasma current no faults.
912:39:13:450PMPlasmaOkGood shot.
1012:57:31:340PMPlasmaOkgood shot.
1101:18:48:660PMPlasmaOkPlasma OK
1201:39:01:980PMPlasmaOkoh2u and l com fail
1302:00:49:090PMPlasmaOkno plasma
1402:11:29:270PMPlasmaOk200 ka
1502:32:43:270PMPlasmaOkPlasma shot no breakdown no faults.
1602:42:19:880PMPlasmaOkPlasma shot OK OH2 U single phased.
1702:56:55:210PMPlasmaOkgood shot
1803:09:20:230PMPlasmaOkPlasma shot No faults.
1903:24:27:580PMPlasmaOkPlasma shot no faults.
2003:40:55:540PMPlasmaOkPlasma shot no faults.
2103:53:03:770PMPlasmaOkPlasma shot No faults.
2204:07:33:400PMPlasmaOkPlasma shot no faults.
2304:22:40:850PMPlasmaOkPlasma shot No faults.
2404:41:00:320PMPlasmaOkPlasma shot no faults.
2504:53:07:080PMPlasmaOkPlasma shot no faults.
2605:05:46:880PMPlasmaOkPlasma shot fault OH2 L.