| Run 930608 Horne, Daigle, Golovato Plan was to work on radial control. Instead we mostly had power supply problems and startup ailments. We did use the new pressure diagnostic (a Ratiomatic controller with a nude gauge) to determine that the first signs of gas appear between 35 and 40 msec after the puff. The gauge sees the plasma, so if there is a breakdown it can't be trusted. The dud shots show reasonable signals. Shots 1-3 had problems with power supplies, including that for the hybrid camac crate. Shot 4 fizzled, shot 5 had horrendous runaways & hard x rays. A spot on the RF limiter glowed brightly afterwards. Shots 5-9 are a scan of gas puff timing. 5 had the inherited puff at + 12 msec. Shot 6 we moved the puff back to -30 msec, then advanced it to -20, (7,8) and -10 (9,10,11) We then moved it to -5 and left it there. Good shots were 5,9,11,16,20,and 21. They all broke down near +5 msec. Most of the other broke down later. duds (no fizzle) were 1,2,3,14,15. These are good to check the ratiomatic signal. On shot 17 we adjusted the r_cur controller by reducing the EF3 weight and increasing the PID to compensate partially. I haven't checked whether this changed plasma behavior. Current rise was too non-reproducible to make this sort of thing worthwhile. Starting around shot 20 I turned over the first 50 msec of the shot to Ian to try to improve current rise. |
| Physics Operator Summaries |
| Session Leader Comments | |||
| Jun 8 1993 09:28:59:470AM | Steve Horne | run 930608
comutation resistors: ef1l=118.8 ef1u=118.2 oh1=65.3 oh2l=12.8 oh2u=12.9 ef2u/l=45 run goals - improve radial control or if the shot reliability is poor (too many fizzles) work on breakdown and initial current rise reproducibility. | |
| Jun 8 1993 09:49:11:400AM | 930608001 | Steve Horne | shot 930608001
same as shot 930604019 (last shot from last friday) except pulsed gas moved from 12-50ms instead of 12-100ms. pre-fill 6.e-5. no plasma, tf crowbar at 55ka, -1.2sec. no ef3u/l. no problem found. re-taking shot. |
| Jun 8 1993 10:21:42:440AM | 930608001 | Steve Horne | shot 930608002
retake of first shot. same problems. also, hybrid camac crate not working correctly, all signals maxed out (this was also true of first shot). hybrid problem corrected by replacing crate power supply. tf problem is apparently interlock on one phase of one supply. appears to be a faulty interlock, it was bypassed. |
| Jun 8 1993 10:38:40:770AM | 930608001 | Steve Horne | shot 930608003
another retake of first shot. same tf problem. disconnnected wrong interlock. try again. hybrid camac worked. |
| Jun 8 1993 10:51:32:630AM | 930608004 | Steve Horne | shot 930608004
breakdown, no current. nothing obviously wrong. |
| Jun 8 1993 11:06:16:940AM | 930608005 | Steve Horne | shot 930608005
try it again. worked but had runaways. For next shot, shift gas programming earlier by 40 msec. |
| Jun 8 1993 11:16:47:880AM | 930608006 | Steve Horne | shot 930608006
shifted gas programming earlier by 40 msec. dud! probably too much gas. move forward 10ms (30ms earlier than shot 005). |
| Jun 8 1993 11:30:59:040AM | 930608007 | Steve Horne | shot 930608007
moved pulsed gas forward 10ms, starts at -20ms. re-take. some differences in the magnetics according to ian (bz early ion time). |
| Jun 8 1993 11:41:42:730AM | 930608007 | Steve Horne | shot 930608007
breakdown seems to be delayed by moving pulsed gas earlier (comparing shots 5 and 6), consistant with higher pressure as seen in pre-fill scan last friday. however shot 7 broke down the same time as 5 but didn't go. |
| Jun 8 1993 11:47:53:020AM | 930608008 | Steve Horne | shot 930608008
didn't go again. will move pulsed gas forward again by 10ms to -10ms. |
| Jun 8 1993 12:11:34:920PM | 930608009 | Steve Horne | shot 930608009
moved pulsed gas forward again by 10ms to -10ms. good shot, but hugged inner wall. slow current ramp (~2.5ma/ms), without the early hesitation. |
| Jun 8 1993 12:11:42:930PM | 930608009 | Steve Horne | shot 930608009
moved pulsed gas forward again by 10ms to -10ms. good shot, but hugged inner wall. slow current ramp (~2.5ma/ms), without the early hesitation. |
| Jun 8 1993 12:27:21:640PM | 930608010 | Steve Horne | shot 930608010
repeat of shot 9. fizzled. |
| Jun 8 1993 12:37:57:930PM | 930608011 | Steve Horne | shot 930608011
reduced bz (lowered ef4 by 30 amps to 670a for t=-.1 to 0) to reduce plasma motion toward inner wall at breakdown. good shot, almost identical to shot 9. |
| Jun 8 1993 12:51:31:960PM | 930608012 | Steve Horne | shot 930608012
move pulsed gas forward again by 5ms to -5ms to try to increase current ramp rate, to help keep plasma off of the inner wall. fizzled. |
| Jun 8 1993 01:16:42:910PM | 930608012 | Steve Horne | shot 930608013
further reduced ef4 current by 30a to 640a from -.1 to 0. fizzled. |
| Jun 8 1993 01:37:09:570PM | 930608014 | Steve Horne | shot 930608014
maybe we're going the wrong way. raise ef4 back to 700a. also move time that it goes to 700a from -.1 to -.2 s to give feedback more time to get it there. no plasma. ef4 and ef2l failed, faulty interlock indication. |
| Jun 8 1993 02:19:39:510PM | 930608015 | Steve Horne | shot 930608015
retry last shot. granetz arrays show plasma is lost down when it doesn't work, not to the inner wall. seems to be shot-to-shot variations in br, since we are not changing anything that affects br. no plasma, ef4 shut down at -1s. ef2l also didn't work. |
| Jun 8 1993 02:30:09:700PM | 930608016 | Steve Horne | shot 930608015
worked, finally. plasma broke down low, then centered rather than diving down as in shots that don't go. |
| Jun 8 1993 02:30:52:610PM | 930608016 | Steve Horne | shot 930608016
previous log was for shot 16, not shot 15. |
| Jun 8 1993 02:55:36:570PM | 930608017 | Steve Horne | shot 930608017
reduced rcur controller for ef3 to about half, making ratios of oh1, oh2, ef3 roughly as suggested by wolfe, but about a factor of 10 higher. rcur pid gain increased from .2 to .3. previous shot was good but inside by about 5cm. fizzled. hardly as flash. marmar suggests that walls are loaded with gas by good shot which leads to several fizzles which depletes them allowing a good shot, which reloads the walls... |
| Jun 8 1993 03:04:19:000PM | 930608018 | Steve Horne | shot 930608018
ef4 voltage and current programming changed to make bz slightly lower. fizzled. |
| Jun 8 1993 03:04:29:040PM | 930608018 | Steve Horne | shot 930608018
ef4 voltage and current programming changed to make bz slightly lower. fizzled. |
| Jun 8 1993 03:19:43:650PM | 930608018 | Steve Horne | shot 930608019
drop pre-fill to 5.e-5. fizzled. plasma dove down. |
| Jun 8 1993 03:28:53:550PM | 930608020 | Steve Horne | shot 930608020
dropped oh2 demand from 20 to 10v for first 8ms to provide a more vertically stable breakdown (at ian's suggestion). pre-fill is 4.e-5 not 5.e-5 for last 2 shots. worked but runaways (not as bad as previous runaway shot) |
| Jun 8 1993 04:04:48:170PM | 930608021 | Steve Horne | shot 930608021
raised pre-fill to 5.e-5 to suppress runaways. raised oh2 voltage programming back to 20v (added 10 v) and re-arranged oh1 voltage roughly adding 50v. purpose is to get the voltages to be consistant with the turns ratio. again this is ian's suggestion. got plasma without runaways. |
| Jun 8 1993 04:18:08:400PM | 930608022 | Steve Horne | shot 930608022
added 100a to ef2s at comuitation and a little (<0.1) derivative gain to rcur at 50 ms. fizzled. broke down late, dove down. |
| Jun 8 1993 05:06:06:470PM | 930608022 | Steve Horne | shot 930608023
reduce ef4 by 100a from 650 to 550. increase in ef2 gave too much bz at breakdown. |
| Jun 8 1993 05:06:18:650PM | 930608022 | Steve Horne | shot 930608023
reduce ef4 by 100a from 650 to 550. increase in ef2 gave too much bz at breakdown. fizzled. |
| Jun 8 1993 05:06:33:200PM | 930608022 | Steve Horne | shot 930608024
fizzled. |
| Jun 8 1993 05:12:33:790PM | 930608022 | Steve Horne | shot 930608025
better fizzle Last shot.. |
| Physics Operator Comments |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:34:26:070AM | Plasma | Bad | TF supply faulted com Fail @ 55K amp. |
| 2 | 09:52:55:060AM | Plasma | Bad | camac & TF comm. fault. |
| 3 | 10:22:15:770AM | Plasma | Ok | power supply fault TF comm fault. |
| 4 | 10:38:47:370AM | Plasma | Ok | Plasma shot no faults |
| 5 | 10:50:50:180AM | Plasma | Ok | Good shot good plasma |
| 6 | 11:06:59:640AM | Plasma | Ok | No faults |
| 7 | 11:20:54:110AM | Plasma | Ok | No faults |
| 8 | 11:37:19:170AM | Plasma | Ok | Plasmas shot No faults. |
| 9 | 11:53:39:010AM | Plasma | Ok | Good shot |
| 10 | 12:10:04:140PM | Plasma | Ok | Good shot |
| 11 | 12:27:45:010PM | Plasma | Ok | Good shot |
| 12 | 12:41:13:030PM | Plasma | Ok | Good shot |
| 13 | 01:02:52:980PM | Plasma | Ok | Plasma shot no faults. |
| 14 | 01:18:43:700PM | Plasma | Bad | ef2 L ef4 faults no Plasma |
| 15 | 01:57:17:700PM | Plasma | Bad | Power supply fault ef2L & EF4 |
| 16 | 02:17:53:980PM | Plasma | Ok | plasma shot no faults. |
| 17 | 02:34:39:240PM | Plasma | Ok | Plasma shot no faults. |
| 18 | 02:45:47:240PM | Plasma | Ok | Plasma shot no faults |
| 19 | 03:07:38:630PM | Plasma | Ok | Good shot |
| 20 | 03:22:04:140PM | Plasma | Ok | Plasma Shot no faults. |
| 21 | 03:54:32:410PM | Plasma | Ok | PLasma shot no faults. |
| 22 | 04:10:17:020PM | Plasma | Ok | Plasma shot No Faults. |
| 23 | 04:22:31:190PM | Plasma | Ok | Plasma shot No Faults |
| 24 | 04:45:06:840PM | Plasma | Ok | PLASMA SHOT NO FAULTS. |
| 25 | 04:57:13:480PM | Plasma | Ok | PLASMA SHOT NO FAULTS. |