| Engineering Operator Comments |
| Shot | Time | Type | Status | Comment |
| 1 | 09:31:13:570AM | Test | Bad | No master reset Power supply stayed in forced invert |
| 2 | 09:53:05:380AM | Test | Bad | ef3 stuck in forced invert. |
| 3 | 10:06:46:900AM | Test | Ok | EF3 test OK |
| 4 | 10:34:27:730AM | Test | Ok | EF3 o.k. |
| 5 | 10:48:23:080AM | Test | Ok | |
| 6 | 10:54:15:590AM | Test | Ok | EF3 and OH1, OH1 switch did not fire |
| 7 | 11:12:06:700AM | Test | Ok | shot O.K. |
| 8 | 11:26:50:670AM | Test | Ok | good pulse |
| 9 | 01:12:50:490PM | Test | Ok | good shot |
| 10 | 01:53:38:530PM | Test | Ok | noisy signals with all supplies on. |
| 11 | 02:14:55:890PM | Test | Bad | 60 cycle ripple on oh1 |
| 12 | 02:23:59:350PM | Test | Ok | oh 1 good by itself. |
| 13 | 02:39:09:490PM | Test | Bad | 60 hertz signal 1000 amps on oh 2 |
| 14 | 02:52:00:550PM | Test | Ok | OH2 l OK by itself. |
| 15 | 02:59:34:700PM | Test | Ok | OH2U O.K by itself. |
| 16 | 03:08:50:730PM | Test | Ok | OH2U and L only |
| 17 | 03:23:38:620PM | Test | Bad | 1000amps of 60 hz on oh2 with oh1 on |
| 18 | 03:50:16:110PM | Test | Ok | I gain change on OH2L seemed to help |
| 19 | 04:11:57:080PM | Test | Ok | Good shot after lowering OH2 current gain. |
| 20 | 04:27:31:720PM | Test | Ok | All supplies - GOOD |
| 21 | 06:12:44:610PM | Test | Bad | Joah testing pellet shot cycle |
| 22 | 06:24:37:950PM | Test | Bad | still not working |
| 23 | 07:09:32:000PM | Test | Bad | martins is still not working |
| 24 | 07:21:02:210PM | Test | Bad | noop |