| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Martin Greenwald |
| Physics operator(s): | Joseph Snipes |
| Engineering operator(s): | Unknown |
| Engineering Operator Run Comment |
| ohmic transport - Snipes |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:08:273PM |
| Author: To Be Determined |
| Run Summary for July 7, 1993 The intention was continue the parameter scans begun yesterday in pursuit of data suitable for confinement studies. In particular, we attempted to push density at the highest currents available. Only a few shots will be useful because: 1. Only 1 of the first 12 shots had substantial plasma current - and it disrupted at .15 sec,; 2. We still have trouble raising the density, even when operating near .5 MA. 3. On shot 18 and after 19, the ECE instrument ran into problems and took no data. Of 25 shots we had 7 duds, 7 fizzles, 11 plasmas. Of the 11 plasmas, 6 were (more or less) disruption free. ->Shots 930730013, 014, 015, and 019 deserve a closer look. ->Note that Record (thermal) Plasma Currents were reached successively on ->shots 18 and 19. Ip = .515 MA on 19. Line averaged densities on these shots were approximately 1 x 10^20. The calculated density limit should be on the order 4 x 10^20. It is far from clear why we have so much trouble in this regard. By shot 24 we had only reached 1.5 x 10^20. Zeff was ~ 1 for much of this shot. Note that for reasons too embarrassing to Bob Granetz to mention here, the time base for xray diagnostics for shots 1-14 are partially corrupted. |
| Physics Operator Summaries |
| Session Leader Comments | |||
| Jul 30 1993 09:46:45:710AM | Joseph Snipes | Ohmic Transport Run
Scaling of density at fixed current around 400 to 450 kA starting with 930729025, which was a good shot from yesterday. Argon will be added to get ion temperatures from HIREX. Otherwise, attempting stable reproducible plasmas. | |
| Jul 30 1993 10:04:32:040AM | 930730001 | Martin Greenwald | Start by trying to repeat 930729025
Fizzle |
| Jul 30 1993 10:30:22:720AM | 930730001 | Joseph Snipes | Shot 1
Starting with 930729025 except moving Ar puff from 0 to -100 ms. Reduced H gas around 200 ms to attempt to flatten the density after 200 ms. Flash, but no current rise |
| Jul 30 1993 10:30:40:880AM | 930730001 | Joseph Snipes | Shot 2
Starting with 930729025 except moving Ar puff from 0 to -100 ms. Reduced H gas around 200 ms to attempt to flatten the density after 200 ms. Flash, but no current rise |
| Jul 30 1993 10:31:08:270AM | 930730002 | Joseph Snipes | Shot 2
Repeat. Same. |
| Jul 30 1993 10:37:47:960AM | 930730002 | Joseph Snipes | Shot 3
Moved Ar puff to -50 ms and reduced it a bit after the initial puff. Moved start of Bay A side gas puff to 18 ms. Reduced prefill to 1.2 x 10**-5 Torr. Wimper! |
| Jul 30 1993 10:44:21:880AM | 930730002 | Martin Greenwald | Fizzle
|
| Jul 30 1993 10:41:38:050AM | 930730003 | Joseph Snipes | Shot 3
Moved Ar puff to -50 ms and reduced it a bit after the initial puff. Moved start of Bay A side gas puff to 18 ms. Reduced prefill to 1.2 x 10**-5 Torr. Wimper! |
| Jul 30 1993 10:44:31:650AM | 930730003 | Martin Greenwald | Fizzle
|
| Jul 30 1993 10:55:46:050AM | 930730004 | Martin Greenwald | Good startup, disrupts at .175 sec, .3 MA
|
| Jul 30 1993 11:04:38:110AM | 930730005 | Joseph Snipes | Shot 5
EF2U current program copied into EF2L program to balance those coils. Also notch removed from the gain on ZCUR wire 2 that was put is several days ago by Horne for the EFC. Dud! |
| Jul 30 1993 11:05:17:030AM | 930730005 | Martin Greenwald | Fizzle
|
| Jul 30 1993 11:23:33:160AM | 930730006 | Joseph Snipes | Shot 6
Increased prefill to 1.2 x 10**-5 Torr. Dud! |
| Jul 30 1993 11:30:51:580AM | 930730006 | Martin Greenwald | Dud
|
| Jul 30 1993 11:30:59:670AM | 930730007 | Martin Greenwald | Dud
|
| Jul 30 1993 11:45:25:450AM | 930730007 | Joseph Snipes | Shot 7
Decreased prefill to 9 x 10**-6 Torr. Took out imbalance that had been programmed in EF2 by reducing EF2L by 40 A to 1710 A at commutation. |
| Jul 30 1993 11:47:34:780AM | 930730008 | Martin Greenwald | Fizzle
|
| Jul 30 1993 11:49:50:500AM | 930730008 | Joseph Snipes | Shot 8
Increased prefill to 1.3 x 10**-5 Torr. Fizzle! |
| Jul 30 1993 11:58:09:150AM | 930730008 | Joseph Snipes | Shot 8
Commutation failure in EF1 supply. |
| Jul 30 1993 12:12:48:010PM | 930730009 | Martin Greenwald | Dud
|
| Jul 30 1993 12:27:04:010PM | 930730009 | Joseph Snipes | Shot 9
Reduced EF2L by 10 A to 1700 A to balance with EF2U. Dud! |
| Jul 30 1993 12:41:00:460PM | 930730010 | Joseph Snipes | Shot 10
Increased prefill to 1.4 x 10**-5 Torr. Fizzle! |
| Jul 30 1993 05:05:35:090PM | 930730010 | Martin Greenwald | Fizzle
|
| Jul 30 1993 12:48:56:790PM | 930730011 | Joseph Snipes | Shot 11
Increased gas puff from Bay A side early at -10 ms. Fizzle. |
| Jul 30 1993 05:05:43:260PM | 930730011 | Martin Greenwald | Fizzle
|
| Jul 30 1993 12:59:27:510PM | 930730012 | Joseph Snipes | Shot 12
Decreased prefill to 1 x 10**-5 Torr. fizzle |
| Jul 30 1993 05:05:56:600PM | 930730012 | Martin Greenwald | Fizzle
|
| Jul 30 1993 01:29:49:540PM | 930730013 | Martin Greenwald | Good Shot
Ip = .46 nel = .5^20 Very Interesting MHD effect seen on soft xrays at .22 to .23 sec |
| Jul 30 1993 01:33:24:430PM | 930730013 | Joseph Snipes | Shot 13
O.K. shot |
| Jul 30 1993 01:42:04:080PM | 930730014 | Joseph Snipes | Shot 14
Increasing proportional gain on ZCUR from 0.4 to 0.6. Increased RCUR prop. gain from 2 to 3 starting at 100 ms. Decent shot. |
| Jul 30 1993 01:59:12:290PM | 930730014 | Martin Greenwald | Good Shot
Ip = .47 MA Never mind on the MHD; This is a result of Granetz's batch job, which changed the digitization rate. |
| Jul 30 1993 02:01:49:540PM | 930730014 | Joseph Snipes | Shot 14
Increasing proportional gain on ZCUR from 0.4 to 0.6. Increased RCUR prop. gain from 2 to 3 starting at 100 ms. Decent shot. |
| Jul 30 1993 02:04:27:100PM | 930730015 | Joseph Snipes | Shot 15
Increasing gain on RCUR from 0.1 s on for EF3. Decent shot. |
| Jul 30 1993 02:35:33:260PM | 930730015 | Martin Greenwald | Good Shot again
Fringe lost on at least one density channel |
| Jul 30 1993 02:35:46:160PM | 930730016 | Martin Greenwald | Good Shot again
|
| Jul 30 1993 02:37:43:800PM | 930730016 | Joseph Snipes | Shot 16
Increasing gas from A side at 150 msec to raise the density and also increased Ar slightly to increase HIREX signals. Decent shot. |
| Jul 30 1993 03:01:13:050PM | 930730017 | Joseph Snipes | Shot 17
Decreasing gas from A side at 150 msec but, then increasing it at 170 ms with a short puff followed by another puff at 230 ms to raise the density. Decent shot. |
| Jul 30 1993 03:02:55:080PM | 930730017 | Joseph Snipes | Shot 18
Changed gas from A side to 4 short gas puffs and zeroed gas from B side upper after 27 ms. Decent shot. |
| Jul 30 1993 05:12:38:260PM | 930730017 | Martin Greenwald | Good Startup
Disrupts halfway through |
| Jul 30 1993 03:03:14:670PM | 930730018 | Joseph Snipes | Shot 18
Changed gas from A side to 4 short gas puffs and zeroed gas from B side upper after 27 ms. Decent shot. |
| Jul 30 1993 03:14:15:890PM | 930730018 | Martin Greenwald | Good Shot again
Record Ip - .503 MA |
| Jul 30 1993 03:37:26:850PM | 930730019 | Joseph Snipes | Shot 19
Changed gas from A side to 4 short gas puffs and zeroed gas from B side upper after 27 ms. Decent shot. |
| Jul 30 1993 05:13:15:770PM | 930730019 | Martin Greenwald | Good Shot
No ECE |
| Jul 30 1993 03:53:40:330PM | 930730020 | Joseph Snipes | Shot 20
Changed gas puffs a bit. Decent shot, but radiated power high toward the end. Disrupted. |
| Jul 30 1993 05:13:48:750PM | 930730020 | Martin Greenwald | Good Startup - disrupts half way
No ECE |
| Jul 30 1993 04:00:35:140PM | 930730021 | Joseph Snipes | Shot 21
Reduced Ar puff a bit. Increased H puffs at 60 and 85 ms. Dud after the previous disruption. |
| Jul 30 1993 05:14:24:410PM | 930730021 | Martin Greenwald | Dud
|
| Jul 30 1993 04:05:59:290PM | 930730022 | Joseph Snipes | Shot 22
Try again. Dud again. |
| Jul 30 1993 05:14:39:170PM | 930730022 | Martin Greenwald | Dud
|
| Jul 30 1993 04:16:51:290PM | 930730023 | Joseph Snipes | Shot 23
Increasing prefill to 1.2 x 10**-5 Torr. Decent shot. |
| Jul 30 1993 04:28:27:770PM | 930730023 | Martin Greenwald | Good Shot - After several duds
|
| Jul 30 1993 04:33:28:340PM | 930730024 | Joseph Snipes | Shot 24
Decreasing prefill to 1.0 x 10**-5 Torr. Decent shot. |
| Jul 30 1993 04:43:15:920PM | 930730024 | Martin Greenwald | Good Shot
No ECE |
| Jul 30 1993 04:58:58:220PM | 930730025 | Martin Greenwald | Dud
|
| Jul 30 1993 04:59:08:180PM | 930730025 | Joseph Snipes | Shot 25
Increased proportional gain on RCUR from 3 to 5 after 100 ms. Also increased H gas puffs a bit. Dud. |
| Physics Operator Comments |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:47:34:890AM | Plasma | Ok | no faults -- no plasma |
| 2 | 10:18:46:260AM | Plasma | Ok | no faults -- no plasma |
| 3 | 10:31:54:710AM | Plasma | Ok | no faults -- no plasma |
| 4 | 10:44:53:090AM | Plasma | Ok | no faults -- first plasma |
| 5 | 11:00:10:030AM | Plasma | Ok | no faults -- fizzle |
| 6 | 11:15:54:150AM | Plasma | Ok | no faults -- no plasma |
| 7 | 11:27:32:000AM | Plasma | Ok | no faults -- no plasma |
| 8 | 11:44:58:490AM | Plasma | Bad | ef1 u+l comm fail -- supply voltage does not hold in inversion |
| 9 | 12:04:55:140PM | Plasma | Ok | no faults -- no plasma |
| 10 | 12:28:03:170PM | Plasma | Ok | no faults |
| 11 | 12:42:40:900PM | Plasma | Ok | no faults |
| 12 | 12:54:33:450PM | Plasma | Ok | no faults |
| 13 | 01:15:33:510PM | Plasma | Ok | no faults 450ka, almost 0.5sec plasma!!!! |
| 14 | 01:37:52:980PM | Plasma | Ok | no faults good plasma again |
| 15 | 01:59:36:600PM | Plasma | Ok | no faults -- plasma >0.5sec |
| 16 | 02:17:43:990PM | Plasma | Ok | no faults -- plasma |
| 17 | 02:39:25:390PM | Plasma | Ok | no faults |
| 18 | 03:00:14:180PM | Plasma | Ok | no faults |
| 19 | 03:22:29:080PM | Plasma | Ok | no faults |
| 20 | 03:37:57:250PM | Plasma | Ok | no faults |
| 21 | 03:54:25:720PM | Plasma | Ok | no faults |
| 22 | 04:03:45:860PM | Plasma | Ok | no faults |
| 23 | 04:14:43:500PM | Plasma | Ok | no faults |
| 24 | 04:30:23:020PM | Plasma | Ok | no faults |
| 25 | 04:54:16:830PM | Plasma | Ok | no faults |