| Miniproposals | ||||||||||||
|
| Operators | |
| Session leader(s): | Bruce Lipschultz,Brian Labombard |
| Physics operator(s): | John Goetz |
| Engineering operator(s): | Joe Daigle |
| Engineering Operator Run Comment |
| mp016 divertor |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:08:507PM |
| Author: To Be Determined |
| Physics operator summary for 930811. EO: Daigle PO: Goetz SL: BLIP,BLAB This run was based on MP016 - Scrapeoff Layer Characterization I; which is to make lower x-point plasmas. The beginning shot was 930810025. Changes required to this shot were: 1)move the x-point up slightly, and 2)make the plasma more elliptical. Both of these objectives were achieved although the plasmas obtained were not quite satisfactory for the Mini-proposal. Control of the x-point was tried using pre-programmed current in the EF1's and EF2's. This method is an unsatisfactory way of trying to twiddle in the desired x-point location. The controllers KAPPA, Z_XL, and R_XL need to be implemented and tweaked up. The ZCUR controller was very sensitive to the P and D gains and was fighting the IC_EF1's. Severe oscillations and non-control were evident over a very narrow range of the gains. Tweaking of the IC_EF1's did result in achieving kappa=1.6 over the times of interest. This resulted in diverted plasmas, but the oscillations in ZCUR caused the x-point to go back and forth between upper and lower (and sometimes double). When the z-position was held somewhat constant, the divertor did remain in the lower chamber, although the strike point locations weren't acceptable to the session leaders. A rapid outward movement of the first eight plasmas was due to a programmed voltage on EF3 in anticipation of reversed EF4. When this voltage was removed, the RCUR controller worked very well. No engineering troubles today. The computer system got caught in a file access lock state that was fixed after much hard work. Overnight mini-bake and warm ECDC were performed before the run. Fill pressure was 1.2e-5 and remained so throughout the run. Many pulses were added to PULSE_GAS_3 during the run in order to flat-top the density. No attempt at a density scan was done. Scorecard: 22 shots - 20 plasmas + 2 data system tests Shot summary for 930811 Reload of 930810025 1 P_0=1.2e-5 spike on PULSE_GAS_3 @.2sec plasma 2 spike on PULSE_GAS_3 @.15sec RCUR=.69 ZCUR=-.02 plasma P_ZCUR=3. D_ZCUR=5. 3 EF1's to 2700A (.2->.4sec) plasma 4 ZCUR=-.03 spike on PULSE_GAS_3 @.25sec plasma 5 spike on PULSE_GAS_3 @.3sec, first spike .02sec earlier plasma EF1's extended to .425sec @2700A 6 spike on PULSE_GAS_3 @.35sec EF1L to 2800A plasma KAPPA controller on; P_kappa=1.0 7 EF1's moved earlier to .16sec plasma 8 P_ZCUR=4.0 RCUR=.69 plasma 9 data system test test 10 data system test test 11 P_ZCUR=5.0 D_ZCUR=8. P_KAPPA=2.0 plasma remove positive swing on V_EF3 @.35sec 12 P_ZCUR=4.0 P_KAPPA=3.0 IC_EF1L=2950A IC_EF2L=875A plasma 13 P_ZCUR=5.0 D_ZCUR=10.0 IC_EF1L=2800A plasma 14 EF1's=3100A IC_EF2L=775A P_ZCUR=2.0 P_KAPPA=1.0 plasma 15 EF1's=3300A remove EF1 current dip @.1sec V_OH2's=-20V plasma 16 IC_EF2L=850A P_ZCUR=7.5 plasma 17 P_ZCUR=7.0 plasma 18 no changes plasma 19 no changes plasma 20 P_ZCUR=6.6 raise and widen second spike on PULSE_GAS_3 plasma 21 P_ZCUR=6.0 lower second spike on PULSE_GAS_3 plasma 22 no changes plasma |
| Physics Operator Summaries |
| Session Leader Comments | |||
| Aug 11 1993 08:58:08:810AM | John Goetz | Run 930811
EO: Daigle PO: Goetz SL: BLip This run is based on MP016 - Scrapeoff Layer Characterization I - Make lower x-point plasmas and diagnose them with the flush-mount probes and fast-scanning probe (FSP). We plan to start with a setup of shot # 930810025 (@~380ms) from yesterday. Changes that we are looking for are: (1)move the x-point back up slightly; (2) make the plasma more elliptical (without upper x-point); (3) rf limiter must remain at R=.96. The plan is to settle on a discharge and then insert the scanning probe. Assuming this is successful then we will do a density scan. At some point we plan check the effect of Ar on the radiated power. | |
| Aug 11 1993 09:34:50:570AM | 930811001 | Bruce Lipschultz | shot # 001:
We didn't quite achieve the same conditions as 930811025. The plasma was centered vertically on the midplane (yesterday it was 5 cm down) and the major radius was 66.5 (x-rays) and 64 (from filament fit). However, the x-point did seem to be the right height. Changes for shot # 002 will be to move the plasma out 2 cm and down 1 cm. |
| Aug 11 1993 09:52:21:900AM | 930811002 | Bruce Lipschultz | shot # 002:
We got a double-null plasma. For the most part it was limited on the inner and outer limiters - so a very wide plasma. For the next shot we will try to increase the elongation in order to pull the plasma off the limiters. |
| Aug 11 1993 10:11:22:620AM | 930811003 | Bruce Lipschultz | shot # 003
The plasma seems to divert around 350 ms. However, it still seems to be a double-null. The x-point has moved out a bit and the plasma is slightly more elongated. For the next shot, zcur=-3, ef2 lower decreased by 25 A to 750A, and pulsed gas increased to try and flatten out the density. |
| Aug 11 1993 10:32:56:110AM | 930811004 | Bruce Lipschultz | shot # 004
This shot is pretty similar. It moved down another .5 mm and so was more single-null-like than double-null. The density needs to be raised early in time - the SXR's are a little high and the density is staying low early in time. We increased the first pulsed gas spike and moved it to 75 ms. We also added another gas puff later in time. We took off 25A off of EF2 lower (now 725A). |
| Aug 11 1993 10:52:11:530AM | 930811005 | Bruce Lipschultz | shot # 005
This shot is better in terms of plasma cleanliness. The density increased early in time and stayed up. The sXR, HXR, bolos and Zeff all dropped. The plasma position was virtually unchanged - semi-diverted late in time. Changes for the next shot are: lower EF2 lower by 50 A to 675A; raise EF1 lower to 2800 A from 2700A (the changes in EF coils are to move the x-point out); move the first gas puff earlier (60 ms ) and added another puff at 350 ms; turned on the kappa controller. |
| Aug 11 1993 11:13:47:270AM | 930811006 | Bruce Lipschultz | shot # 006
This shot is again an improvement in terms of density control. We are not getting any improvement in position/divertor action. Changes for the next shot are move the EF1 current flattop from 200 to 160 ms. There was a silicon injection on this shot. The rf is supposed to start pulsing low power the next shot. |
| Aug 11 1993 11:32:00:020AM | 930811007 | Bruce Lipschultz | shot # 007
This shot is similar to 006. We will try again try to change the plasma and x-point position; rcur = .7 and lower EF2-lower by 50 A to 625 A. We increased the gain on zcur as well. In addition the Ar is turned on the next shot at 200 ms. |
| Aug 11 1993 12:05:41:860PM | 930811008 | Bruce Lipschultz | shot # 008
Still no particular success with x-point position. We will increase EF2 lower back to its original level (725A) and try again. |
| Aug 11 1993 12:46:00:020PM | 930811009 | Bruce Lipschultz | shot # 009
Because of problems with the datasystem, this shot is just to run the data system after reboot. Additional changes for shot 10 include: increase p_kappa from 1 to 2.0; EF2 lower current to 775 A; Z_cur=5., D_zcur=8.; Ar puff to 100 msec; removed a positve porch from V_EF3 - now @ -78V from 350 msec on. |
| Aug 11 1993 02:13:37:200PM | 930811011 | Bruce Lipschultz | shot # 011
Because of problems with the datasystem, shot s 9 and 10 were tests of the data system. Shot # 11 looks pretty good in terms of the x-point (r,z) = (56,-38). For the next shot we will try to pull the x-point outward in major radius earlier and pull the plasma off the inner wall (increase kappa). To do this we changed: lower p_zcur to 4.; IC_ef2l -> 878 A @ 160 ms (from 775A) and ->825 A @ 400 msec; IC_ef1L -> 2950A @ 160 msec and 400 msec; P_kappa to 3.0 (from 2.0). The Ar puff was moved to 0 time. |
| Aug 11 1993 02:37:12:420PM | 930811012 | Bruce Lipschultz | shot # 012
This shot was not an improvement. The kappa decreased from 1.6 to 1.4 and the x-point position did not change. We will switch ef1 back to where it was last shot and leave everything else the same. |
| Aug 11 1993 03:00:24:530PM | 930811013 | Bruce Lipschultz | shot # 013
The position and ellipticity are still not satifactory. We will try another tack; go for a high-kappa double-null. For shot 14 we have changed the ef1's to 3100 A for the flattop, IC_ef2l back to 725 A, p_zcur to 2.0 and p_kappa to 1.0 (from 3.0). |
| Aug 11 1993 03:19:33:390PM | 930811014 | Bruce Lipschultz | shot # 014
The position and ellipticity were somewhat improved; kappa approaching 1.6 (from 1.4). There was a disruption at 450 ms when the impurity injector increased the radiated power by too much for a falling current plasma. For the next shot we will try to increase the ef currents (top and bottom) to further increase kappa and also increase the OH2 currents to increase triangularity and pull the plasma off the inner wall. The changes are: add 10V to V_oh2l & upper (to -20V from -30V). Change I_EF1 (U&L) to 3300A. |
| Aug 11 1993 03:36:56:780PM | 930811015 | Bruce Lipschultz | shot # 013
The position and ellipticity were somewhat improved again; The plasma was diverted at earlier tmes (230-260 ms) as well as late in time.kappa approaching 1.6 (from 1.4). However, the plasma is approximately centered vertically. For the next shot we will try to increase the ef2l current to pull the lower x-point out in major radius. The changes are: EF2l from 775A to 850A. |
| Aug 11 1993 03:56:00:530PM | 930811016 | Bruce Lipschultz | shot # 013
Again, the ellipticity is good. The plasma is diverted most of the discharge. However, the plasma vertical position is oscillating so the plasma is changing back and forth from upper x-point to lower x-point. For the next shot we will try to decrease P_zcur to 7.0 from 7.5 to get rid of the oscillation. |
| Aug 11 1993 04:17:26:260PM | 930811017 | Bruce Lipschultz | shot # 017
Again, the ellipticity is good. The plasma is diverted less of the discharge. In fact, Ian's reconstruction and FFIT don't agree. FFIT claims that the plasma is lower-diverted from 200-320 ms. Ian's reconstruction claims it is never diverted. Brian's flush-mount probes see plasma over the period 200 to 350ms. It is a slot divertor at 350 ms. Bob's UV-bolometer has signal from 220 to 320 ms. No changes fro the next shot in magnetics. |
| Aug 11 1993 04:30:00:960PM | 930811018 | Bruce Lipschultz | shot # 018
Again, the ellipticity is good. The plasma is diverted for a similar amount of time in comparison to the last shot. For this shot Ian's reconstruction and FFIT do roughly agree. The plasma is lower-diverted from 200-320 ms. No changes for the next shot in magnetics. Brian is planning to put the FSP all the way in the next shot (now closest approach is 2 cm). |
| Aug 11 1993 04:44:59:490PM | 930811019 | Bruce Lipschultz | shot # 019
Again, the ellipticity is good. The plasma is diverted for a similar amount of time in comparison to the last shot. The plasma oscillated in vertical position again. The density has also been dropping, especially during diverted periods. We will increase the gas puff for the next shot and decrease P_zcur from 7. to 6.6. |
| Aug 11 1993 04:55:08:250PM | 930811020 | Bruce Lipschultz | shot # 020
Again, the plasma vertical position was oscillatory We will decrease P_zcur from 6.6 to 6. |
| Aug 11 1993 05:20:18:690PM | 930811021 | Bruce Lipschultz | shot # 022
Plasma position was oscillatory. Otherwise a good shot. |
| Physics Operator Comments |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:09:36:880AM | Plasma | Ok | Plasma first shot Power systems O.K. |
| 2 | 09:30:41:420AM | Plasma | Ok | plasma |
| 3 | 09:52:07:340AM | Plasma | Ok | plasma shot no faults. |
| 4 | 10:09:28:980AM | Plasma | Ok | plasma shot no faults. |
| 5 | 10:30:14:110AM | Plasma | Ok | plasma shot no faults |
| 6 | 10:50:53:840AM | Plasma | Ok | Plasma shot no faults |
| 7 | 11:11:56:920AM | Plasma | Ok | Plasma shot no faults. |
| 8 | 11:35:18:850AM | Plasma | Ok | 55ka plasma |
| 9 | 12:38:41:810PM | Test | Ok | power supplies were not energized. |
| 10 | 01:34:20:130PM | Test | Ok | data system |
| 11 | 01:45:18:660PM | Plasma | Ok | good plasma once again |
| 12 | 02:12:26:800PM | Plasma | Ok | Plasma shot No faults. |
| 13 | 02:37:42:480PM | Plasma | Ok | good shot, plasma |
| 14 | 02:58:36:790PM | Plasma | Ok | Plasma shot no faults. |
| 15 | 03:20:36:240PM | Plasma | Ok | plasma, good shot |
| 16 | 03:40:17:180PM | Plasma | Ok | plasma, good shot |
| 17 | 03:56:04:100PM | Plasma | Ok | plasma pulse no faults |
| 18 | 04:15:32:820PM | Plasma | Ok | Plasma shot No faults. |
| 19 | 04:30:26:030PM | Plasma | Ok | plasma shot O.K |
| 20 | 04:45:15:860PM | Plasma | Ok | plasma shot No faults. |
| 21 | 04:58:57:760PM | Plasma | Ok | plasma shot no faults. |
| 22 | 05:12:15:620PM | Plasma | Ok | Plasma shot no faults. |
| 23 | 05:28:07:100PM | Test | Ok | ef4 fwd only hybrid as with plasma shots -- no single phasing |
| 24 | 05:39:11:140PM | Test | Ok | ef4 double swing ok |