| Engineering Operator Comments |
| Shot | Time | Type | Status | Comment |
| 1 | 08:08:40:240AM | Test | Ok | Ef1 lower put out half the program current. |
| 2 | 08:22:17:500AM | Test | Ok | EF1 REVERSE OK BUT LOWER RESPONDS WITH HALF OF COMMAND |
| 3 | 08:37:01:880AM | Test | Ok | OH1 TEST DIDNT FIRE |
| 4 | 08:46:04:780AM | Test | Bad | OH1 CURRENT PROGRAM AT 5KA AND OUTPUT WENT TO 32KA |
| 5 | 09:01:59:950AM | Test | Ok | OH2 5KA OK |
| 6 | 09:13:23:630AM | Test | Ok | OH2 OK |
| 7 | 11:28:59:020AM | Test | Ok | POWER SUPPLY DID NOT TURN ON. |
| 8 | 11:38:58:030AM | Test | Ok | EF1 WORKED WELL |
| 9 | 11:47:32:250AM | Test | Bad | OH1 NOT CURRENT LIMITING |
| 10 | 11:58:03:210AM | Test | Bad | EF1 U&L FAULT- 1SCR NOT CONDUCTING UPPER |
| 11 | 12:07:30:910PM | Test | Bad | EF1 ONE SCR NOT CONDUCTING UPPER |
| 12 | 12:33:18:480PM | Test | Bad | ONE SCR NOT CONDUCTING FAULT @ 8KA DEMAND. |
| 13 | 12:42:13:460PM | Test | Ok | EF1 GOOD SHOT |
| 14 | 12:50:50:780PM | Test | Ok | EF1U+L COND FAIL |
| 15 | 01:16:38:020PM | Test | Bad | OH1 NOT OPERATING. |
| 16 | 02:29:30:210PM | Test | Bad | |