Entered: Jul 7 2004 03:49:09:087PM
Author: To Be Determined
Physics operator's summary for run 931012

Session leader: M. Greenwald
Physics operator: R. Granetz
Engineering leader: F. Silva

The primary goal of today's run was to achieve plasma currents of 1.0 MA
(actually -1.0 MA), and that was realized on shots #7,8,11, and 13. However,
all of these shots ended in a major disruption. We also had a very
nice 0.76 MA discharge (#5). A secondary goal of today's operation was to
acquire more data for ohmic confinement, and this was achieved by virtue of
the new current levels. However, this being a Tuesday run, we had our share
of hardware problems, particularly with fuses and SCR's in OH1, and with
a computer problem, resulting in some lengthy delays and only 15 shots.
(But what counts is quality, not quantity!). One problem that we did NOT seem
to have was getting a plasma. There were only two fizzles, and all shots
broke down (other than a dud due to no EF3 on one shot).

The run was preceeded with 1 hour of ECDC, and the first shot was copied
from 931007024 last week. Working gas was deuterium.

Shot Comments Changes for next shot

1 Ip=-0.62 MA, disrupted at 0.61 s. lowered pulse gas
voltage (PGV)

2 Ip=-0.66 MA, duration=1.13 s, detaches Raise Ip to -0.75 MA
at 0.7 s. Nice shot.

3 Runaway, high density. OH1 fuses and SCR's Tweak PGV initial
blown. 2 hr 40 min downtime to repair supply. spike

4 Fizzle Tweak PGV initial
spike

5 Ip=-0.76 MA (new record), duration=1.15 s, Raise Ip to -1.00 MA
Very nice shot. OH1 blew more fuses.

6 No EF3, no breakdown

7 Ip=-1.0 MA (new record), major disruption at Raise PLC current
t=0.94 s. Hit PLC limits on OH1, OH2's. limits on OH1, OH2's

8 Ip=-1.00 MA, major disruption at 0.90 s. Lots Engineers adjusted
of molybdenum injections. Spectroscopic evidence OH2 circuitry
of stainless steel contamination seen.

9 Short, disruptive

10 Short, disruptive Tweak PGV by 2 to 4v

11 Ip=-1.0 MA, major disruption at 0.59 s. Large Tweak PGV initial
impurity injection at 0.35 s spike

12 Computer problems cause 1 hr delay.
Short, disruptive

13 Ip=-1.0 MA, major disruption at 0.75 s. Tweak PGV

14 Short, disruptive Tweak PGV

15 Fizzle.

Physics Operator Summaries

Session Leader Comments
Oct 12 1993 09:01:16:250AMMartin GreenwaldRun Plan -
Start with shot 931007024
Ramp current to 1 MA, keep kappa safely below limit
Look for scaling of confinement time.

Oct 12 1993 09:07:48:940AM931012001Martin GreenwaldStart with shot 931007024
breaks down, but disrupts at .62 sec

Oct 12 1993 09:31:37:310AM931012002Martin GreenwaldLower gas slightly
Good shot, Ip = .67 MA, shark fin at .7 sec
nl goes almost to 1e20

Oct 12 1993 09:59:24:450AM931012003Martin GreenwaldRunaways early, disrupts at .28 sec

Oct 12 1993 12:30:47:220PM931012004Martin GreenwaldRepeat more or less after long delay to fix power supply problem
fizzle

Oct 12 1993 01:28:28:870PM931012005Martin GreenwaldVery good shot
Ip = .77 MA - new record!

Oct 12 1993 01:28:55:980PM931012006Martin GreenwaldDud - no EF3

Oct 12 1993 02:00:31:580PM931012007Martin GreenwaldReached .995 MA !!!

disrupted at .93 sec, .83 MA in 2 msec
probably due to a plc current limit

Oct 12 1993 02:56:32:930PM931012008Martin Greenwaldraise program Ip by 10-20 kA
fix plc limit

Reached 1.00 MA !!

Oct 12 1993 02:57:23:160PM931012009Martin GreenwaldDisrupts at .2 sec

Oct 12 1993 03:25:42:390PM931012010Martin GreenwaldAnother early disruption

Oct 12 1993 03:26:09:130PM931012011Martin GreenwaldReaches 1 MA but disrupts shortly thereafter.

Oct 12 1993 04:10:57:560PM931012012Martin GreenwaldAnother early disruption.

Oct 12 1993 04:25:22:750PM931012013Martin GreenwaldReaches 1 MA But disrupts at .75.

Oct 12 1993 04:45:20:100PM931012014Martin GreenwaldDisrupts early.

Oct 12 1993 04:55:04:350PM931012015Martin Greenwaldfizzle.

Physics Operator Comments
Oct 12 1993 09:18:41:650AM931012001Robert GranetzGot a plasma, but it was ugly and disruptive due to too much gas. Ip=-0.62 MA,
duration=0.61 s. No interferometer data on this shot. For the next shot, I
lowered the pulse gas by about 6% (from 55 to 52 v for the initial spike, and
from 49 to 46 from t=0.1 to 0.8 s.

Oct 12 1993 09:32:16:720AM931012002Robert GranetzReasonably good shot. Ip=-0.66 MA, duration=1.13 s. Disrupted halfway
down the current rampdown. There may have been a change to a detached
plasma at t=0.7 s, because the density begins rising suddenly there. The
latter half of the shot has nl=1.0-0.8 e20.

Oct 12 1993 09:37:26:110AM931012002Robert GranetzFor the next shot, the only change is to increase the plasma current
demand to -0.75 MA.

Oct 12 1993 09:53:48:110AM931012003Robert GranetzShort, disruptive, runaway shot, but density rises quite fast. Ip reaches
-0.54 MA before the major disruption at 0.27 s. No changes were made to
anything before 0.3 s. There was a PF fault, after the disruption I think.
OH1 lost two fuses.

Oct 12 1993 10:05:48:270AM931012003Robert GranetzTom Hsu opened the ECE gate valve during the CHECK state, which may not have
given the gas pre-fill system enough time to settle down. However, the
ratiomatic doesn't corroborate this.

For the next shot, the only change is to increase the initial spike on the
pulse gas programming from 52 to 55 v.

Oct 12 1993 12:25:15:980PM931012004Robert GranetzBetween this shot and the previous one there was an extended downtime in order
to fix several blown fuses and SCR's in OH1.

Oct 12 1993 12:43:40:060PM931012004Robert GranetzFizzle. Protoplasma shoots outwards at t=0.019 s. For the next shot, just
decrease the initial pulse gas spike from 55 to 53 v.

Oct 12 1993 01:39:23:390PM931012005Robert GranetzGood shot. Ip=-0.76 MA, duration=1.15 s. Really nice.
Blew a few more OH1 fuses though. This is a new record plasma current.

Oct 12 1993 01:40:25:750PM931012005Robert GranetzNo changes for the next shot.

Oct 12 1993 01:39:51:340PM931012006Robert GranetzNo EF3. No breakdown. No changes for next shot.

Oct 12 1993 02:02:26:340PM931012007Robert GranetzIp=1.0 MA ! (actually 0.995 MA). Shot ended with a vertical instability
downward. dIp/dt=-(0.4 to 0.5) MA/ms. The current started drooping prior
to the requested start of rampdown, because we hit the PLC limits for the
OH1 and OH2's. That may also explain the problem with ZCUR control. For the
next shot, the only change is to increase Ip from 1.00 to 1.01 MA.

Oct 12 1993 02:20:50:270PM931012007Robert GranetzFor the next shot, raise the PLC limits on the OH1 and OH2's to +20 kA.

Oct 12 1993 02:20:05:340PM931012008Robert GranetzIp=1.00 MA, but again ended in a major disruption, this time with
dIp/dt=-0.4 MA/ms. There were lots of molybdenum injections on this shot.
The ZCUR feedback doesn't seem to be working well.

Oct 12 1993 02:44:11:060PM931012008Robert GranetzOH2L is not following the voltage demand from the hybrid. The engineers have
adjusted something in the supply. No changes for the next shot.

Oct 12 1993 02:59:57:570PM931012009Robert GranetzUgly, short, disruptive. Shot ends at 0.21 s with a major disruption, when
the current is still ramping up. Density ramp looks very similar to the
previous two shots. No changes for the next shot.

Oct 12 1993 03:18:55:060PM931012010Robert GranetzUgly, short, disruptive. Slightly longer than the last shot though.
Shot terminated during the current rampup. There were a lot of runaways on
this one. For the next shot, raise the initial pulse gas spike from 52 to
54 v, and also from 46 to 50 v at 0.8 s.

Oct 12 1993 03:42:14:860PM931012011Robert GranetzAnother 1 MA, but it disrupted at t=0.59 s. The major disruption took nearly
3 msec. There was a large impurity injection at 0.35 s. I don't think
this diruption was caused by a vertical control problem. For the next shot,
increase the initial pulse gas spike from 55 to 57 v, and also add a second
argon gas puff after the shot (at 1.2 s), for calibration purposes in
preparation for the divertor argon gas puff run on Thursday.

Oct 12 1993 04:04:22:710PM931012012Robert GranetzPrior to this shot there was a long pause due to computer problems.

Oct 12 1993 04:13:22:060PM931012012Robert GranetzUgly, short, disruptive. For the next shot, reduce the initial pulse
gas spike from 57 to 55 volts.

Oct 12 1993 04:28:50:940PM931012013Robert GranetzBetter. Ip=-1.00 MA, duration=0.75 s. Terminated by a major disruption.
The initial plasma was disruptive, and there were many impurity injections
throughout the discharge. For the next shot, decrease the initial pulse gas
spike from 55 to 54 volts, and increase the demand Ip from 1.01 to 1.02 MA
(negative).

Oct 12 1993 04:50:13:390PM931012014Robert GranetzUgly, short, disruptive. For the next shot, reduce the pulse gas during
the valley at about t=0.030 s to 35 volts.

Oct 12 1993 04:55:44:190PM931012015Robert GranetzFizzle.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:01:19:640AMPlasmaOkrun on time, plasma on first shot
209:21:33:860AMPlasmaOkplasma comm fail
309:41:52:830AMPlasmaOkcomm fail
412:26:24:150PMPlasmaOkps,s ok
512:42:34:570PMPlasmaOkfuses blown in oh1
601:25:08:760PMPlasmaBadno ef3
701:41:57:550PMPlasmaOkps,s ok record plasma 995 ka
802:02:52:310PMPlasmaOkps,s ok no faults 1.04 ma
902:46:03:220PMPlasmaOkmargin angle change on oh2l ps,s ok no faults
1003:01:14:530PMPlasmaOkno countdown or pulse announce
1103:21:19:820PMPlasmaOk1.03 ma ps,s ok
1204:00:13:640PMPlasmaOkigor problem fixed ps,s ok
1304:19:49:980PMPlasmaOkps,sok
1404:35:43:710PMPlasmaOkps,s ok
1504:52:46:380PMPlasmaOklast shot fizzel?