| Engineering Operator Comments |
| Shot | Time | Type | Status | Comment |
| 1 | 01:47:30:870PM | Test | Ok | Alternator excitation test and Panic Button test OK |
| 2 | 02:17:24:140PM | Test | Ok | EF1L 2.5 kA test OK |
| 6 | 03:19:14:950PM | Test | Bad | No EF3 |
| 7 | 03:27:00:990PM | Test | Ok | OH2's fired but picture is confused |
| 8 | 03:41:04:550PM | Test | Bad | Spurious Commutation fault indication OH2U early in pulse |
| 9 | 03:52:16:950PM | Test | Ok | OH2L test OK |
| 10 | 03:57:48:160PM | Test | Ok | OH1 works + output current |
| 11 | 04:14:17:040PM | Test | Ok | OH1 - current OK, EF2U OK, EF2L OK |
| 12 | 04:20:02:900PM | Test | Ok | EF2 and OH1 Rev OK |
| 13 | 04:26:15:360PM | Test | Ok | OH1 commutation OK; EF4 +current OK |
| 14 | 04:37:36:520PM | Test | Ok | TF test at 40 kA OK |
| 15 | 04:48:02:170PM | Test | Bad | TF failed to invert at 100 kA |