Alcator C-Mod Run 940513 Information

Back to runs

Miniproposals
Miniproposal:
Date Filed:
Title:
First Author:
Session Leader:Steve Wolfe (shots 1-26)

Operators
Session leader(s):Steve Wolfe
Physics operator(s):Steve Horne
Engineering operator(s):Steve Fairfax,Vinny Bertolino

Engineering Operator Run Comment
flux loop test -- plasma?

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:09:790PM
Author: To Be Determined
Run Summary for Friday, 5/13/94

MP 041 - Restart CMOD
SL: wolfe
PO: horne
EO: bertolino/fairfax

The first two hours were devoted to demonstrating whether the flux loop
problem was inside or outside the machine. We did several tests using a crude
(but effective) winding outside the machine, connected to the inputs for
F22,F23, and F25 using the same cable and female connector as is used for the
magnetics. There was no sign of any problems with these signals, implying that
the problem is inside.

Shot#2 was a TF-only test, for the purpose of getting pickups for SNIPE's BP
loops.

The remainder of the run was an attempt to determine if we could in fact run
with this many missing flux loops, or if it would be necessary to break vacuum
and repair at least some.

Shot 7 was the first attempt for plasma, done by recalculating all the
magnetics predictors, ignoring F22 (as well as F23,F25,F17). This shot
fizzled. Shot 9 was the first plasma shot, gotten by lowering the pressure and
making the Br_0 1 mTesla more negative; this was a 400 msec shot, but the
OH2's started doing funny things at around 200msec. After this shot, it was
found that BP18_BC had caught the flux loop disease!

We then struggled for a number of shots, trying to get another good shot.
Several tweaks of fields and gas were made, mostly to no avail. Shot #12 went
and lasted 400 msec. This was also the shot on which we lost BP25_BC. We
continued struggling until shot 21, after which I became convinced that the
early RCUR feedback was useful and needed to be done right (we had delayed
this because it was using the bad BP loops, and so was doing the wrong thing.)

The first shot after we swapped the BPxx_BC loops for the BPxx_DE loops into
the Hybrid (and updated the Hybrid CONFIG, and recalculated all the magnetics
predictors, again) was shot 22; this shot was a good plasma lasting until 230
msec, with problems beginning at 200msec. All subsequent shots ran, except 23
on which the pressure was too high. We succeeded in getting one shot that made
it through current flattop and died during rampdown (#25) by turining off
CLEARIN and ZXL (ZXL had gain=10.0000, which had previously been found to
cause problems). Shot 26 had CLEARIN and ZXL turned back on, with timing and
gains adjusted, and lasted until 470msec; this one may have died from too high
an elongation.

The question of whether we could run without the four missing flux loops was
rendered somewhat moot by the fact that we continued to lose magnetics during
this run, and there seemed no end in sight. All of the bad signals are on
B-bottom flange, most on two connectors. While I think, given another day and
stable magnetics count, we could have established satisfactory operation with
the present magnetics set, the continued erosion of available signals makes a
repair attempt advisable. The machine will be brought up to helium on Monday
morning.

No futher progress on the substance of MP 041 was made today. We still need to
demonstrate gap and x-point control, and matching to the antenna limiter shape
and position, to satisfy the stated goal of having the operation ready to
carry out the physics program of Phase II.

Altogether, we made four trips into the cell, stopping cooling and waiting for
O2 to rise each time, and still got in 26 shots in an eight hours.

Scorecard:

Tests 6
Duds 6
Fizzles 8
Plasmas 6
------- --
total 26

Physics Operator Summaries
Entered: Jul 7 2004 04:36:51:210PM
Author: To Be Determined
Run 940513
Physics Operator Report
Horne (Phys op) Wolfe (Session leader), MP 41

Another unusual run.

Last night I installed a 1 turn "flux loop" of perhaps .3 m^2 taped here and there under
the machine. It was connected to Bob's integrators via his official cable -- the idea
was to test all his circuitry for f25,f22,f23 -- hoping to reveal a fault in his rack
somewhere. This was connected for shots 1-3 (one of these was tf only). The signal level
was too small to verify operation, so we threw together a 50 turn coil (area 7 m^2) and
installed it in place of the one turn loop. This gave a decent signal; all the
integrators, etc seemed to work. To hammer in the last nail we used a cliplead to ground
the end of this cable to the machine (another cell access) , and again observed good
behavior. We concluded from this that whatever's broken is in vacuum; entered the cell
again to reconnect Bob's cable to his feedthrough.

We then proceeded to test the idea that we could run the machine using only the last
miserable remnant of Bob's functioning flux loops. It became clear as we struggled that
there were also two more bad BP loops connected to the hybrid, and we decided to break
once more to replace them with functional loops from the DE set. This was our 4'th cell
access today, and as a result we got plasma on 4 of the last 5 shots, loosing one due
unusually high fill pressure (no settings were changed, we just got more gas than usual.)

While our success on those last shots implies that we could probably run the machine
in this configuration, the rather constant rate of failure per shot -- perhaps
1/10 of a diagnostic per shot, averaged over 3-4 runs, is very discouraging.
The current plan is to do a helium backfill on Monday, pull the b_bot port
and try to repair what we can. (All the problems are associated with this port.)

One outstanding result of the run -- the work on the coolling system over the break
has significantly reduced the nitrogen buildup in the cell, to the extent that
quick access to the cell is possible. This combined with the fizzle detector
reducing the coil heating on fizzles, allowed us to get both 26 shots and 4 trips
to the cell today.

shot
1 fake loop test
2 tf only
3 stack only
Break for cell access to install multiturn loop
4 multiturn fake loop, all pf coils
5 multiturn fake loop, stack only
Break for cell access to ground Bob's cable
6 multiturn connector grounded, all coils (except ef1, still warm)
Break for cell access to remove fake loop and reconnect Bob's cable.
recalculated predictors on wires 1-8 (after turning f22 off in hybrid tree)

Offsets for these wires for next shot:

wire name offset
1 rcur 10000
2 zcur 10000
3 zcur 10000
4 zxl 0
5 rxl 0
6 clearin 0
7 br -.0035
8 rcur 10000
br p gain at 5.

7 first plasma attempt; Flash.
8 dud
9 plasma
10 dud
11 fizzle. 1.2
Plasma is breaking down late. For next shot, raise ef4 i from -1020 to -990
12 plasma!
13 dud 1.2 delay clearin,dud
14 dud 1.2
15 fizzle 1.2 ef4 to 1005
16 dud 1.0 gas
17 fizzle 1.2 br -.004 (up .0005)
18 1.2
21 ef4 neg 15 A to -1020
Break for cell access; switch 2 bad bp_bc coils for de coils.
Change hybrid tree, recalculate everything again.
22 good shot -- 220 msec plasma
23
turned z_xl pid off. It was at +10, exactly.
Deleted a P point on rxl -- result is that
it now turns on at gain of .38 and change High gas
Fizzle
24 no change, good shot 250 msed
25 clearin gone (turned P gain off), 700 msec plasma!
26 zxl gain=8, 350, clearin 5 420, 470 msec plasma


Session Leader Comments
May 13 1994 08:25:40:750AMSteve WolfeRun Plan for 940513:
SL: wolfe
PO: horne
EO: bertolino

First shot will be a test of the magnetics electronics, with the B/bot#2
connector removed from the machine and connected to a large loop.

We may, depending on what we find, do a BT only shot to get pickup
data on the SNIPES loops.
If errors are observed on the first test, implicating electronics
outside the machine, we will try to isolate the problem, then shut down
so repairs can be done by next week.

If no errors are observed on the electronics test, implying the problem
really is inside the machine, we will reconnect the B/bot#2 connector
and attempt to run, using new predictors that ignore F22, as well as F23,
F23,F25, and of course, F17. The program will be to complete MP041.

If running is successful, further analysis will still be required
to determine whether we actually are able to diagnose and control
the x-point region well enough to carry out the physics program. If
we cannot get reasonable plasmas, or if subsequent analysis indicates
that we really need the bad loops, we will need to have a vacuum break
next week.

May 13 1994 05:40:56:910PMSteve WolfeErratum:
In several places in today's notes I refer to B/bot#2 connector. The
actual connector in question is B/bot#1 .

May 13 1994 11:12:26:740AM940513007Steve WolfeShot 940513007:
Back together and try to run.
Do a call_alg on all magnetics predictors
Fizzle detector 0.1 : 1.1
Turn Br0 gain back on.
P= 1.3e-5

Result:
Fizzle. Breakdown at 6.6msec

May 13 1994 11:27:09:320AM940513008Steve WolfeShot 940513008:
Drop the pressure to 1.0e-5 and go again.
The previous Br looked a tiny bit positive, but leave it for now.

Result:
Dud. Br still looks positive to me.

May 13 1994 11:59:04:080AM940513009Steve WolfeShot 940513009:
Change BR0 offset from -3.5e-5 to -4.5e-3

Result:
Plasma,
Late breakdown - 10msec
just over 400msec
BP18_BC may have just lost it.
The ZXL is driving the OH2's crazy. It has gain of 10.0000

May 13 1994 12:07:37:370PM940513010Steve WolfeShot 940513010:
Turn off ZXL gain.

Result:
dud

May 13 1994 12:27:03:600PM940513011Steve WolfeShot 940513011:
Turn off ZXL gain.
Raise P to 1.2e-5

Result:
fizzle - bd at 10.5msec
Br looks a little negative; so does Bz.

May 13 1994 12:49:24:540PM940513012Steve WolfeShot 940513012:
Change IC_EF4 by +30Amps

Result:
Plasma. Lasts till 400msec. OH2U still goes back negative starting at
200msec.

BP25_BC went dead on this shot.

May 13 1994 12:58:57:560PM940513013Steve WolfeShot 940513013:
Delay CLEARIN gain from 200msec to 350msec

Result:
dud

May 13 1994 01:09:12:860PM940513014Steve WolfeShot 940513014:
No change

Result:
Dud.

May 13 1994 01:25:41:730PM940513015Steve WolfeShot 940513015:
Put EF4 back negative by 15A, to -1005

Result:
fizzle - breakdown at 10msec

May 13 1994 01:37:20:630PM940513016Steve WolfeShot 940513016:
Drop the gas to 1.0e-5

Result:
dud

May 13 1994 01:55:57:120PM940513017Steve WolfeShot 940513017:
Raise gas to 1.2e-5 again
Put Br_0 offset 0.5mT more positive, to -4.0mT

Result:
fizzle, breakdown at 10msec.

May 13 1994 02:09:05:680PM940513018Steve WolfeShot 940513018:
No change

Result:
fizzle- breakdown 12msec

May 13 1994 02:24:53:670PM940513019Steve WolfeShot 940513019
Lower gas to 1.1e-5

Result:
fizzle - bd at 11msec

May 13 1994 02:53:05:090PM940513020Steve WolfeShot 940513020
Turn off RCUR feedback until 40sec (it's using the bad Bp's)

Result:
dud

May 13 1994 03:41:01:990PM940513021Steve WolfeShot 940513021
Set EF4 to -1020A (15A more negative)

Result:
fizzle - bd at 11msec

May 13 1994 03:52:25:470PM940513022Steve WolfeShot 940513022
Swapped BP18_BC and BP25_BC for the DE loops
Modified the Hybrid CONFIG tree
Did CALL_ALG on all relevant predictors.

Result:
plasma dies at 230 msec
same nonsense on OH2's at 200msec

May 13 1994 04:07:36:770PM940513023Steve WolfeShot 940513023

Turn off ZXL gain
Move RXL gain to 380msec (delete first step)

Result:
fizzle, late breakdown - 12.8 msec

May 13 1994 04:23:13:500PM940513024Steve WolfeShot 940513024

No change

Result:
plasma - short again 250 msec
same nonsense at 200msec

May 13 1994 04:37:06:090PM940513025Steve WolfeShot 940513025

Get rid of CLEARIN gain

Result:
Good long shot, around 700msec
died during current ramp-down

May 13 1994 05:37:04:120PM940513026Steve WolfeShot 940513026

Turn ZXL on gain=8 at 350msec
and CLEARIN at g=5 at 420 msec

Result:
Plasma - lost it at 470m, may have just gone to too high an elongation.

Physics Operator Comments
May 13 1994 09:02:34:620AM940513001Steve WolfeShot 940513001:
This will be a test of the magnetics electronics. The B/bot#2 connector
is removed from the machine, and F22,F23,F25 pins are all connected to
a loop of wire.

Br_0 gains are turned to zero in PCS, leaving IC control only.
Inverts are set at 0.02 sec.
Fizzle detecot is on from 0.1 to 2.1, as a backup.

Result:
Signal is only about 20 MWb on the 3 loops, a lot smaller than we
expected.

May 13 1994 09:11:02:310AM940513002Steve WolfeShot 940513002:
TF only test. Fizzle detector changed to run 1.1 to 2.1

Result:
well, at least something is working.

May 13 1994 09:11:35:830AM940513002Steve WolfeShot 940513002:
TF only test. Fizzle detector changed to run 1.1 to 2.1

Result:
well, at least something is working.

May 13 1994 09:21:20:710AM940513003Steve WolfeShot 940513003:
Stack only, see if we get better signal.

Result:
Hardly any signal on those 3. We'll go down an try hooking up
a multi-turn coil, and see what might be going on.

May 13 1994 09:26:31:350AM940513003Steve WolfeShot 940513003:

Note that EF3 got about 1000amps induced.
Also note the other Floops with no signals include F01, F19,F21,F23,
F25,F26

May 13 1994 10:00:01:570AM940513004Steve WolfeShot 940513004:
Change to about 50 turns .14m2 form.

All PF's no TF

Result:
about 0.3 Wb, no evidence of the baseline not coming back at the
end of the shot on any of the 3 signals.

May 13 1994 10:20:35:910AM940513005Steve WolfeShot 940513005:
Stack only. EF3 blocked.


Result:
Still no sign of a problem.

May 13 1994 10:30:50:020AM940513006Steve WolfeShot 940513006:
Try grounding the connector to the machine.
Do all PF's except EF1's (they aren't cold yet)

Result:
No sign of a problem. It's inside, damn it!

Engineering Operator Comments
ShotTimeTypeStatusComment
108:53:14:780AMPlasmaOkno faults
209:07:35:210AMTestOkno fault tf only
309:15:46:350AMTestOkoh1, oh2u, oh2l only - no faults
409:53:53:520AMTestOkno faults -- no tf
510:02:14:350AMTestOkno faults -- oh's only
610:25:25:090AMTestOkno faults
711:06:27:010AMPlasmaOkno faults
811:17:56:150AMPlasmaOkno faults
911:35:22:530AMPlasmaOkno faults
1012:00:59:960PMPlasmaOkno fault
1112:16:21:080PMPlasmaOkno faults
1212:30:13:750PMPlasmaOkno faults
1312:51:17:080PMPlasmaOkno faults
1401:03:02:040PMPlasmaOkDud. All else OK
1501:18:30:800PMPlasmaOkFizzle. All else OK. Flux loops still dying.
1601:34:32:740PMPlasmaOkDud. All else OK. Lowering gas did not help.
1701:49:28:040PMPlasmaOkAnother fizzle.
1802:02:49:490PMPlasmaOkAnother Fizzle.
1902:17:25:050PMPlasmaOkTF crowbar entering inversion; appears to be due to adrupt phase-in of
2002:47:27:900PMPlasmaOkdud. All else ok.
2103:02:31:010PMPlasmaOkAll OK. Opening cell to work on flux loops.
2203:47:10:030PMPlasmaOkhot-wiring the magnetics rack gave a 600 kA plasma and 600 kA disruption
2304:00:12:060PMPlasmaOkFizzle; late breakdown but almost went.
2404:15:14:490PMPlasmaOk600 kA plasma; disruption induced OH2L commutation failure
2504:30:59:370PMPlasmaOk600 kA discharge; disrupted at 500 kA on ramp-down; no faults
2604:49:43:110PMPlasmaOk600 kA plasma; 600 kA disruption at .47 sec