Session Leader Summary - 940526 --------------------------------- SL - Golovato PO - Snipes EO - Silva and Daigle Starting with shot 940525031, last good shot of last run. See the logbook under session_leader for shot-by-shot comments. After a frustrating start, this turned out to be an excellent run, probably the best so far this year. We may have found an important problem that led to a lot of the shot-to-shot irreproducibility in breakdown and current ramp. The power supply for the isolation amps for the magnetics signals going to the hybrid may have been flaky, leading to large and varying offsets in the magnetics signals. The fix today was jiggling the wires, we probably should find a clearer identification of the problem and a more robust solution, We eventually made full pulse length plasmas at 600 ka and applied over 1 MW of rf power. There is clear evidence of heating on ece Te ( several hundred eV) and the EFIT stored energy (up to 10 kJ). The power appears limited to about 1 MW at 10 Ohms loading. We get this loading with the plasma on or close to the outer limiter. Moving it in (on the last shot) reduces loading. We need additional conditioning (vacuum and plasma) to get the power up, but this is a great start for only two erratic runs. We got long (in time) plasmas by reducing elongation later in the shot and releasing it from the lower divertor (leaving off feedback on clearin, zxl, and rxl, as was done yesterday), making the coil currents symmetric up-down, and centering zcur. For deltails see the physics operator summary. The run was interrupted for an hour by a computer network crash and a half hour to check (fix) the isolation amp power supply. There appeared to be a problem with injecting argon. Four shots were affected, with the symptom being a slow (not disruptive) decrease in current, killing off the shot (#s 12, 13, 19, 21). On shots 18 and 20, lower argon didn't kill shot but Rice couldn't see it. On the last shot, there was a scandium injection at 750ms. Shot Accounting: Fizzles - 8 Plasmas - 13 (3 very short, 4 argon spoiled, 6 good) Test - 1 (of data system to get offsets) |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:51:600PM |
| Author: To Be Determined |
From: BRIGHT::SNIPES Date: 26-MAY-1994 18:27:24 Description: Physics Operator Summary for 940526 This was an RF tuning run with backup HIREX troubleshooting. In the end, it was a successful run, though plagued with problems early. We started by copying shot 940525031 and got 4 fizzles in a row. Then, the computers crashed and held us up for about an hour to reboot. Shots 5-7 had short plasmas with disruptions during the current rise. Shot 8 fizzled. Shot 9 had again a short plasma. Then, it was noticed that the hybrid offsets were changing shot to shot indicating an intermittent problem in the hybrid. So, we opened the cell to investigate and after wiggling some wires, the hybrid power supply voltages steadied. Shot 10 was a test shot for checking the hybrid offsets. Shot 11 fizzled again. Shots 12-13 had short plasmas and 14 fizzled again. Finally, shot 15 looked pretty good with 600 kA lasting up to almost 600 ms, then disrupting. Shot 16 then fizzled after the big disruption. Shots 17 - 18 looked good, then increasing the Ar puff, led to an early disruption on shot 19. Shot 20 was then good with less Ar. Shot 21 disrupted early with increased Ar. Finally, shot 22 was the best shot of the day with little Ar lasting until the fizzle detector knocked it down at 100 kA. The last few good shots had relatively high RF power up to about 1 MW modulated to look for changes. Electron heating was observed together with increases in the stored energy. The power supplies worked very well! Scorecard 8 fizzles 8 short plasmas 5 good plasmas 1 test shot |
| Session Leader Comments | |||
| May 26 1994 09:06:14:490AM | Steve Golovato | staring with shot 31 from yesterday.
goal for today is good reproducible plasmas matched well to antenna so we can continue raising power. limited, not so elongated plasmas are ok, we'd like to avoid the strong disruptions that contribute to irreproducibility. we had hints of heating yesterday and we'd really like to get enough power to make it clear. | |
| May 26 1994 06:04:13:020PM | Steve Golovato | Session Leader Summary - 940526
--------------------------------- SL - Golovato PO - Snipes EO - Silva and Daigle Starting with shot 940525031, last good shot of last run. See the logbook under session_leader for shot-by-shot comments. After a frustrating start, this turned out to be an excellent run, probably the best so far this year. We may have found an important problem that led to a lot of the shot-to-shot irreproducibility in breakdown and current ramp. The power supply for the isolation amps for the magnetics signals going to the hybrid may have been flaky, leading to large and varying offsets in the magnetics signals. The fix today was jiggling the wires, we probably should find a clearer identification of the problem and a more robust solution, We eventually made full pulse length plasmas at 600 ka and applied over 1 MW of rf power. There is clear evidence of heating on ece Te ( several hundred eV) and the EFIT stored energy (up to 10 kJ). The power appears limited to about 1 MW at 10 Ohms loading. We get this loading with the plasma on or close to the outer limiter. Moving it in (on the last shot) reduces loading. We need additional conditioning (vacuum and plasma) to get the power up, but this is a great start for only two erratic runs. We got long (in time) plasmas by reducing elongation later in the shot and releasing it from the lower divertor (leaving off feedback on clearin, zxl, and rxl, as was done yesterday), makin | |
| May 26 1994 09:09:35:480AM | 940526001 | Steve Golovato | 940526001
shot 31 from yesterday fizzle. |
| May 26 1994 09:40:32:880AM | 940526002 | Steve Golovato | 940526002
fizzled, but better according to wolfe. |
| May 26 1994 09:53:16:590AM | 940526003 | Steve Golovato | 940526003
fizzled. |
| May 26 1994 10:01:05:410AM | 940526004 | Steve Golovato | 940526004
fizzles again. |
| May 26 1994 11:58:05:110AM | 940526005 | Steve Golovato | 940526005
after about an hour delay as computers crashed. got a plasma, 200ka, 130ms, pretty ragged. |
| May 26 1994 12:09:40:860PM | 940526006 | Steve Golovato | 940526006
plasma again, 200ka,200ms. getting earlier breakdowns, 6ms, but moved bz ramp earlier to get current to ramp. current ramps faster at first until contacts outer limiter, knocking off crud. we're trying to keep plasma off outer limiter. |
| May 26 1994 12:30:10:760PM | 940526007 | Steve Golovato | 940526007
plasma, 600ka, 400ms. plasma jumping between diverted and limited, inner and outer limiters, elongated, not so elongated. |
| May 26 1994 12:45:43:350PM | 940526008 | Steve Golovato | 940526008
fizzle. br looks low. |
| May 26 1994 01:53:01:270PM | 940526009 | Steve Golovato | 940526009
150ka, 140ms, pretty ragged. |
| May 26 1994 01:57:27:230PM | 940526010 | Steve Golovato | 940526010
test shot to check offsets. it is thought that the power supply to the isoamps for the magnetics is going. no plasma, no power supplies. there was also a delay to enter the cell and check the supply which was not obviously broken. test shows offsets to now be zero. |
| May 26 1994 02:23:13:780PM | 940526011 | Steve Golovato | 940526011
the offsets in pcs may not be right now that the isoamp supply has been "fixed", that is, they wiggled the leads and the outputs changed to something more reasonable. this power supply may have been flaky for a while and a source of the chronic irreproducibility we've been experiencing. fizzle. br now a little high, offset needs changing. |
| May 26 1994 02:33:11:700PM | 940526012 | Steve Golovato | 940526012
plasma, 300ka, 180ms. moved in and died. |
| May 26 1994 02:47:59:050PM | 940526013 | Steve Golovato | 940526013
much like last shot. |
| May 26 1994 03:02:55:430PM | 940526014 | Steve Golovato | 940526014
fizzle, though everything looks the same. |
| May 26 1994 03:17:31:430PM | 940526015 | Steve Golovato | 940526015
first good shot in a long time. 600ka, 600ms. adjust ef1 and ef2 to avoid elongation after 450ms. |
| May 26 1994 03:28:14:190PM | 940526016 | Steve Golovato | 940526016
(ignor fizzle comment in entry for previous shot, it belonged here) fizzle after disruption. |
| May 26 1994 03:44:26:990PM | 940526017 | Steve Golovato | 940526017
good shot, made it into rampdown. 600ka, 800ms. Prf=1.1MW, plasma diveted after 600ms, 10 Ohms loading. definite electron heating, 10kJ stored energy increase. |
| May 26 1994 03:59:40:820PM | 940526018 | Steve Golovato | 940526018
another good one, 600ka, 900ms. |
| May 26 1994 04:16:29:620PM | 940526019 | Steve Golovato | 940526019
reduce gas after 400 ms to maintain constant density. lost early, looks like the argon may be the problem, which was back on at full force. |
| May 26 1994 04:31:31:500PM | 940526020 | Steve Golovato | 940526020
another 900ms shot, 1MW rf. argon puff moved later, doesn't affect plasma. |
| May 26 1994 04:53:07:050PM | 940526021 | Steve Golovato | 940526021
move plasma in a little after 500ms, see if it reduces rf arcing late in shot with plasma on outer limiter. problem may be argon again, it was increased for this shot. starts down about 430ms, out at 490ms. |
| May 26 1994 05:10:50:880PM | 940526022 | Steve Golovato | 940526022
lowered argon to level where it didn't affect shot. unfortunately, this level also may not be enough to open valve. full length shot, fizzle detector turned it off at 1 sec when it went below 100ka. clear heating on ece and W_efit. plasma moved off outer limiter after 500 ms as programmed, limiter on inside. |
| Physics Operator Comments | |||
| May 26 1994 09:39:31:610AM | 940526001 | Joseph Snipes | Copied shot 940525031 with Ar programming from 940525032.
Fizzle! |
| May 26 1994 09:44:37:390AM | 940526001 | Joseph Snipes | Shot 1
Fill pressure set to 1.2 x 10**-5 torr. |
| May 26 1994 09:40:22:350AM | 940526002 | Joseph Snipes | One more time!
Fizzle! |
| May 26 1994 09:43:39:410AM | 940526003 | Joseph Snipes | Shot 3
Added 0.5 mT to Br to try to get better breakdown. Also made EF1 upper and lower waveforms equal to the EF1U waveform after 0.18 sec to -500 A. Fizzle! |
| May 26 1994 09:56:05:850AM | 940526004 | Joseph Snipes | Shot 4
Fill pressure set to 1.1 x 10**-5 torr. Fizzle! |
| May 26 1994 11:28:47:260AM | 940526004 | Joseph Snipes | Long delay due to computer crash on the LEADER segment.
|
| May 26 1994 11:53:19:870AM | 940526005 | Joseph Snipes | Shot 5
Increased EF4U by 33 A to -995 A before breakdown to increase Bz by about 2 mT. Got plasma! |
| May 26 1994 12:01:06:670PM | 940526006 | Joseph Snipes | Shot 6
Ramping in the radial position somewhat faster early. Also increased EF1U and EF1L to -688 A during flattop. Now got 200 ms of plasma. Slowly improving. |
| May 26 1994 12:28:09:270PM | 940526007 | Joseph Snipes | Shot 7
Zeroed the Z position. Better 400 ms. |
| May 26 1994 12:34:30:240PM | 940526008 | Joseph Snipes | Shot 8
Reduced EF2U and L after about 0.1 sec during the flattop to try to reduce the elongation. Fizzle! |
| May 26 1994 01:47:35:390PM | 940526009 | Joseph Snipes | Shot 9
Increased Br offset to -1.5 mT. Trying again. Short plasma. |
| May 26 1994 01:48:57:370PM | 940526009 | Joseph Snipes | Long delay due to intermittent power supply in the Hybrid control system.
After checking it in the cell, it seems sometimes o.k. So, we will try to run with it while Parkin looks for a new power supply. |
| May 26 1994 02:15:56:170PM | 940526010 | Joseph Snipes | Test shot of data acquisition for checking hybrid offsets.
|
| May 26 1994 02:16:30:590PM | 940526011 | Joseph Snipes | Try again.
Fizzle! |
| May 26 1994 02:37:54:910PM | 940526012 | Joseph Snipes | Shot 12
Lowered Br by another mT to -2.5 mT, since the hybrid now reads a different offset. Good current rise, then went bad after 100 ms. |
| May 26 1994 02:43:21:820PM | 940526013 | Joseph Snipes | Shot 13
Changed RCUR programming from 0.65 m to 0.67 m and changed the ramp inward to go more gradually inward during the current rise. Short plasma. |
| May 26 1994 02:50:58:800PM | 940526014 | Joseph Snipes | Shot 14
Turned off Ar puff that had been on since shot 12. Try again. |
| May 26 1994 03:02:29:400PM | 940526014 | Joseph Snipes | Shot 14
fizzle! |
| May 26 1994 03:05:38:850PM | 940526014 | Joseph Snipes | Shot 15
Try lowering Br by yet another 0.5 mT to -3.0 mT. Plasma! |
| May 26 1994 03:11:51:490PM | 940526014 | Joseph Snipes | Shot 15
Try lowering Br by yet another 0.5 mT to -3.0 mT. Plasma! Last almost 600 ms and reached 600 kA. |
| May 26 1994 03:26:55:800PM | 940526016 | Joseph Snipes | Shot 16
Lowered EF1U and L and EF2U and L after about 200 ms to reduce the elongation during the current flattop. Fizzle! |
| May 26 1994 03:36:59:850PM | 940526017 | Joseph Snipes | Shot 17
One more time . . . Good plasma! |
| May 26 1994 04:00:02:550PM | 940526018 | Joseph Snipes | Shot 18
Set EF1U and L controllers to zero after 0.6 sec in the Ip controller. Ramped EF4U down to zero between 0.5 sec and 1 sec. Good plasma! |
| May 26 1994 04:09:45:760PM | 940526019 | Joseph Snipes | Shot 19
Decreased H gas after 0.4 sec. Increased Ar puff back to previous levels. Disrupted at 140 ms. Perhaps due to the Ar. |
| May 26 1994 04:24:45:010PM | 940526020 | Joseph Snipes | Shot 20
Decreased Ar puff from 100 V to 80 V and moved it from 100 ms to after 300 ms. Good plasma! |
| May 26 1994 04:49:28:410PM | 940526021 | Joseph Snipes | Shot 21
Increased Ar puff from 80 V to 90 V. Reduced gain on OH2U and L in the Ip controller by a factor of 2. Moved RCUR from 0.5 to 0.8 sec in to 0.665 m. Disrupted early! |
| May 26 1994 05:11:18:230PM | 940526021 | Joseph Snipes | Shot 22
Decreased Ar puff from 90 V to 84 V. Sc injection at 0.75 s. Very good plasma ramped down until 100 kA when it was knocked down by the fizzle detector. Sc injection was observed. RF results were good. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:54:33:910AM | Plasma | Ok | good start 08:59 |
| 2 | 09:25:49:420AM | Plasma | Ok | delay ef1l diagnose temp |
| 3 | 09:41:37:480AM | Plasma | Ok | |
| 4 | 09:53:10:920AM | Plasma | Ok | no problem |
| 5 | 11:28:03:970AM | Plasma | Ok | 190 ka |
| 6 | 11:56:09:500AM | Plasma | Ok | plasma |
| 7 | 12:13:25:630PM | Plasma | Ok | comm fail oh2l |
| 8 | 12:30:29:520PM | Plasma | Ok | fizzel |
| 9 | 12:43:37:230PM | Plasma | Ok | Plasma |
| 10 | 01:52:55:360PM | Test | Ok | Power Supplies Dissabled |
| 11 | 02:12:36:690PM | Plasma | Ok | Dud Power supplies O.K. |
| 12 | 02:24:22:120PM | Plasma | Ok | good shot |
| 13 | 02:39:28:320PM | Plasma | Ok | Short pulse no faults |
| 14 | 02:50:35:630PM | Plasma | Ok | dud no faults |
| 15 | 03:03:31:980PM | Plasma | Ok | Good shot No faults |
| 16 | 03:20:24:840PM | Plasma | Bad | dud no faults |
| 17 | 03:31:19:410PM | Plasma | Ok | good shot o.k. |
| 18 | 03:49:49:560PM | Plasma | Ok | Good shot no faults |
| 19 | 04:04:18:460PM | Plasma | Ok | fizzle no faults |
| 20 | 04:17:12:100PM | Plasma | Ok | Good shot No faults |
| 21 | 04:41:15:400PM | Plasma | Ok | Good No Faults |
| 22 | 04:54:56:200PM | Plasma | Ok | good |