Alcator C-Mod Run 940527 Information

Back to runs

Miniproposals
Miniproposal:050
Date Filed: 4/8/1994
Title:Trace Impurity Transport (Laser Ablation Impurity Injection)
First Author:Michael Graf
Session Leader:Michael Graf (shots 1-34)

Operators
Session leader(s):Michael Graf
Physics operator(s):John Goetz
Engineering operator(s):Frank Silva,Joe Daigle

Engineering Operator Run Comment
graf/goetz

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:10:400PM
Author: To Be Determined
Session Leader Summary -- 940527


S.L.: Graf
P.O.: Goetz
E.O.: Silva/Daigle


A run in support of MP 050 -- Trace Impurity Transport....

One goal of today's run was to inject laser blow-off impurities into a
variety of plasmas to help obtain a scaling of confinement times. Due to the
difficulties experienced earlier in the week, plasma quality expectations were
modest. A current scan was determined to be the easiest scan of plasma parameters
with a reasonable chance of success. To this end, we began with shot
940526022 which had a stable flat-top of 650 kA and a controlled ramp-down.
A decision had been made earlier to not ECDC before the day's run. In light
of the problems achieving reliable plasmas earlier in the week, I thought it
would be an interesting (albeit courageous) experiment to see if the lack of
ECDC made any noticeable difference. Three out of four duds to start the day,
however, had me thinking that perhaps I should have chosen to be more daring during
someone else's run. Physics Operator Goetz assures me, however, that field
problems could easily account for the lack of breakdown during those early shots.
The ECDC experiment remains inconclusive, therefore.

Once reliable, quasi-limited discharges were obtained (shot 6) with suitable
injections of scandium during the flat-top (at t=0.55 sec), the current scan was begun. Shots
6 and 9 were at 650 kA, and good (but not outstanding) injection signals were obtained
on the McPherson, HIREX, soft x-ray arrays, etc... Last fall's campaign
definitely seemed to have larger signals for seemingly identical injections.
Whether this is due to differences in injection geometry (there ideally should
be none) or to some real physics inherent in the non-diverted discharges which
were run needs to be investigated. At any rate, 'good enough' signals were
obtained for most shots today. The current was scanned to 750 kA (shot 10),
850 kA (shots 11,13), 600 kA (shot 14), 550 kA (shot 15), 450 kA (shot 17).

Satisfied with the current scan, we began injecting different materials into
identical shots (shots 18(Si), 19(Ca), 20,23,25(Mo)) at 800 kA. These
injections were also all at t=0.55 sec. This was done in an attempt to
evaluate the edge cooling effect of the various materials. Using the grating
polychromator, strongest edge cooling was seen for the moly injections
(perhaps no great surprise). More work will definitely be necessary on MP
045A -- Cold Pulse Propagation in the future. This is work that is easily
done as a piggy-back experiment.

Injections were next performed into moderate RF power (<0.8 MW) discharges
(shots 26,27(Sc),30,31,32(Fe)). Shots 33 and 34 duplicated 32 and 31 without
any RF. The usefulness of those experiments is still being determined. It is
hoped that some conclusion can be drawn regarding the spatial distributions of
the injected materials (via soft x-ray diode array measurements) with and
without RF.

In an attempt to placate as many graduate students as possible
in a single run day, Closed Loop Response (MP 053) experiments in support of
Gerry Tinios were also performed. Shot 20 involved a programmed +1 cm step in
ZCUR for a duration of 60 ms (0.65-0.71 sec). The resulting disruption, I am
told, did hamper neither the acquisition of useful data, nor the expected
graduation date of the relevant party.

This run can be classified as relatively successful. While the plasmas were
of an unique nature (not really diverted, but riding on the inner nose (of the
divertor)), and so are of limited usefulness when comparing with fully
diverted or fully limited shots, there were enough good discharges that one
cannot really complain. The remainder of MP 050 will be carried out as a
series of piggy-back experiments on appropriate days.




Physics Operator Summaries
Entered: Jul 7 2004 04:36:51:600PM
Author: To Be Determined
Physics operator summary for 940527

EO: Silva/Daigle
PO: Goetz
SL: Graf

Run 940527 was in support of Mini-Proposal #050 - Trace Impurity Transport.
To this end, shot 940526022 was loaded into the hybrid. This was the last
'good' shot from 940526 and had 650 kA and a successful rampdown. The only
change made was to add some pulse gas after 0.25s to try and increase the
density. No ECDC was performed before the run.

Today's goals were to try and complete MP #050, do a little cold pulse
propagation, a little RF conditioning, and a little closed loop response.
All goals accomplished today.

The run was plagued by DUDS. Tweaks to Bz (IC_EF4) and Br 'seemed' to make
the null better, but after a few shots another dud would occur. The nulls
were 'acceptable' for 2-3msec for shots that went and <1msec for those that
didn't. Fill pressure for the run was between 1.0 and 1.2 e-5 with no
correlation between plasmas and duds.

All plasmas but two ran to completion. One was killed by too much argon
and the other was killed by the return step from the Closed Loop Mini-Proposal.
This second disruption was followed by a fizzle. It was determined today that
a pressure of ~2.5 PSIA in the plenum is the right amount to achieve a happy
medium for HIREX measurements.

From an operator standpoint, the gains on the ZCUR controller were fiddled
with. Without proportional gain for 100 msec the amplitude of the z-position
oscillation was reduced slightly and only 2mm of position drift was seen. With
no proportional gain and a derivative gain of 0.5, there is 4mm of position
drift. It appears that the OH2L voltage oscillation is independent of its
input. This phenomenon will be investigated further on 940531.

There was no ECDC prior to this run due to leader perogative. The beginning
of the day was dud-dud but fields can explain the problems. The limiter
discharges ran today had Zeff ~ 1.5. There was a moly-deuterium burst at
the beginning of all shots except for those with Ip~.45MA.

Engineering today: Reliable day today for the power systems. One shot lost
to the alternator voltage beginning to ramp down before PULSE and one
shot lost to an ACK failure.

Scorecard: 34 shots = 20 plasmas + 3 fizzles + 9 duds + 2 lost shots

Shot summary for Run 940527

Reload of 940526022

Changes:
Add PULSE_GAS_3 after 0.25s

Shot change result
____ _____ ______
1 P_0=1.1e-5 dud
2 P_0=1.3e-5 dud
3 IC_EF4=-970A fizzle
4 P_0=1.2e-5 BR_0 offset = -.0035 dud
5 IC_EF4=-985A fizzle
6 IC_EF4U to -990A; P_0=1.2e-5 plasma
7 lower PULSE_GAS_3 dud
8 IC_EF2L and IC_EF2U to -1650A (make the null bigger) dud
9 IC_EF4=-1015A to cure Bz plasma
10 IP=-740000 plasma
11 IP=-840000; PULSE_GAS_1 to 0.65s plasma
12 lower PULSE_GAS_3 after 0.2 no shot
13 no changes plasma
14 IP=-550000; B_SIDE_LOWER plenum pressure =2.5 plasma
15 IP=-520000 plasma
16 IP=-420000; raise PULSE_GAS_3 between .1 and .15 dud
17 P_0=1.2e-5 plasma
18 reload 940527013; low power RF; IP=-800000 plasma
19 P_ZCUR=1.5 plasma
20 no RF; .01m ZCUR step from .65 to .71 plasma
21 no integral gain on ZCUR from .65 to .71 (check ZCUR osc.) fizzle
22 P_0=1.1e-5 dud
23 P_IC_OH2U to 2 at -.03 (stop osc.?) plasma
24 raise PULSE_GAS_3 after .2sec; turn integrator back on at .65 dud
25 BR_0 offset = -.003; IC_EF4=-1025A; P_0=1.2e-5 plasma
26 RF on at .5 plasma
27 no changes plasma
28 notch ZCUR derivative gain at .60 to .70 no shot
29 no changes dud
30 IC_EF4=-1035A plasma
31 drop ZCUR derivative gain to 0 at .60 to .70 plasma
32 ZCUR D gain back to 1.; ZCUR P gain notch at .65 to .70
PULSE_GAS_1 to 0.4sec plasma
33 ZCUR P gain to 0 from .60 to .70; change RCUR ramp .1 to .2 plasma
34 ZCUR D gain to .5 from .60 to .70 plasma

Session Leader Comments
May 27 1994 08:12:34:290AMMichael GrafTrace impurity transport run.
Looking for well-behaved flat-tops at a range of currents (.4-1 MA);
starting with good shot from yesterday (940526022). Hoping for diverted
discharges, but will settle for anything achievable.
Will start by injecting scandium during flat-top; later will try moly,silicon,
etc... GPC set up to look for cold pulse propagation. X-ray diode arrays set
up for 25 kHz burst around time of injection. HIREX chords looking at He-like
scandium lines.

May 27 1994 08:44:36:830AM940527001Michael Grafset Sc injection trigger at 500 msec.
Dud. Nice spot on scandium slide, though.

May 27 1994 08:57:41:280AM940527002Michael Grafset Sc injection trigger at 500 msec.
Dud. Nice spot on scandium slide, though.

May 27 1994 09:10:41:210AM940527003Michael Grafset Sc injection trigger at 500 msec.
Fizzle (barely).

May 27 1994 09:11:00:240AM940527003Michael Grafset Sc injection trigger at 500 msec.
Fizzle (barely).

May 27 1994 09:37:04:210AM940527004Michael Grafset Sc injection trigger at 500 msec.
Dud.

May 27 1994 09:42:12:140AM940527005Michael Grafset Sc injection trigger at 500 msec.
strong fizzle, almost went.

May 27 1994 09:58:05:940AM940527006Michael Grafset Sc injection trigger at 500 msec.
good shot. not a lot of scandium seen, though.

May 27 1994 10:15:06:190AM940527007Michael Grafset Sc injection trigger at 500 msec.
dud...

May 27 1994 10:42:33:140AM940527008Michael Grafset Sc injection trigger at 500 msec.
dud...

May 27 1994 10:52:05:400AM940527009Michael Grafset Sc injection trigger at 500 msec.
good shot. lowered flash lamp energyfor this shot (645 to 641).
better signals on softs, McP, same on HIREX

May 27 1994 10:57:34:900AM940527009Michael Grafset Sc injection trigger at 500 msec.
good shot. lowered flash lamp energy for this shot (645 to 641).
better signals on softs, McP, same on HIREX

May 27 1994 11:12:07:460AM940527010Michael Grafset Sc injection trigger at 500 msec.
good shot. lowered flash lamp energy for this shot (641 to 635).
better signals on softs, McP, slightly better on HIREX

May 27 1994 11:12:29:950AM940527010Michael Grafset Sc injection trigger at 500 msec.
good shot. lowered flash lamp energy for this shot (641 to 635).
better signals on softs, McP, slightly better on HIREX

May 27 1994 11:12:36:900AM940527010Michael Grafset Sc injection trigger at 500 msec.
good shot. lowered flash lamp energy for this shot (641 to 635).
better signals on softs, McP, slightly better on HIREX

May 27 1994 11:25:04:700AM940527011Michael Grafset Sc injection trigger at 550 msec this time.
good shot. argon disr'n at 740.
lowered flash lamp energy for this shot (635 to 630).

May 27 1994 11:47:33:570AM940527013Michael Grafset Sc injection trigger at 550 msec this time.
good shot.

May 27 1994 12:07:01:090PM940527014Michael Grafset Sc injection trigger at 550 msec this time.
good shot.

May 27 1994 12:07:28:830PM940527014Michael Grafset Sc injection trigger at 550 msec this time.
good shot.

May 27 1994 12:07:33:620PM940527014Michael Grafset Sc injection trigger at 550 msec this time.
good shot.

May 27 1994 12:41:24:970PM940527015Michael Grafset Sc injection trigger at 550 msec this time.
good shot.

May 27 1994 12:42:15:920PM940527016Michael Grafset Sc injection trigger at 550 msec this time.
Dud.

May 27 1994 01:12:53:720PM940527017Michael Grafset Sc injection trigger at 550 msec this time.
good shot.

May 27 1994 01:13:17:280PM940527018Michael Grafset silicon injection trigger at 550 msec this time.
good shot at 800 kA

May 27 1994 01:35:50:810PM940527019Michael Grafset calcium injection trigger at 550 msec this time.
good shot at 800 kA

May 27 1994 01:53:08:260PM940527020Michael Grafset molybdenum injection trigger at 550 msec this time.
good shot at 800 kA

May 27 1994 01:58:26:330PM940527021Michael Grafset molybdenum injection trigger at 550 msec this time.
strong fizzle.

May 27 1994 02:10:14:390PM940527021Michael Grafset molybdenum injection trigger at 550 msec this time.
strong fizzle.

May 27 1994 02:10:41:950PM940527022Michael Grafset molybdenum injection trigger at 550 msec this time.
dud.

May 27 1994 02:23:50:270PM940527023Michael Grafset molybdenum injection trigger at 550 msec this time.
good shot at 800 kA. mnay naturals around injection time

May 27 1994 02:24:55:640PM940527023Michael Grafset molybdenum injection trigger at 550 msec this time.
good shot at 800 kA. mnay naturals around injection time

May 27 1994 02:43:09:860PM940527024Michael Grafset molybdenum injection trigger at 550 msec this time.
dud.

May 27 1994 03:01:39:720PM940527025Michael Grafset molybdenum injection trigger at 550 msec this time.
good shot. great injection..

May 27 1994 03:11:03:370PM940527026Michael Grafset scandium injection trigger at 550 msec this time.
good shot.

May 27 1994 03:25:44:590PM940527027Michael Grafset scandium injection trigger at 550 msec this time.
good shot. tough to see on softs over RF induced emission.

May 27 1994 04:44:31:570PM940527030Michael Grafset iron injection trigger at 550 msec this time.
good shot. poor injection.

May 27 1994 04:45:04:790PM940527031Michael Grafset iron injection trigger at 550 msec this time.
good shot.

May 27 1994 04:45:12:080PM940527032Michael Grafset iron injection trigger at 550 msec this time.
good shot.

May 27 1994 04:55:32:750PM940527033Michael Grafset iron injection trigger at 550 msec this time.
good shot. No RF during injection this time.

May 27 1994 05:03:38:080PM940527034Michael Grafset iron injection trigger at 550 msec this time.
good shot. No RF during injection this time.

Physics Operator Comments
May 27 1994 08:32:41:500AMJohn GoetzRUN 940527

Mini Proposal 050 - Trace Impurity Transport

Start from 940526022
- add some Pulse_Gas_3 after 0.25 sec
- no pre-run ECDC

May 27 1994 08:53:14:750AM940527001John GoetzShot 001: Dud
null looks as good as shot 22 from yesterday

For Shot 002:
raise fill pressure to 1.3e-5

May 27 1994 09:20:40:540AM940527002John GoetzShot 002: Dud
Bz a little negative; doesn't cross zero until .01

For Shot 003:
IC_EF4 = -970A

May 27 1994 09:21:57:670AM940527003John GoetzShot 003: Fizzle
breakdown at .01 sec - late
Br appears to be a bit positive compared to yesterday

For Shot 004:
BR_0 offset = -.0035
P_0 = 1.2e-5

May 27 1994 09:34:03:330AM940527004John GoetzShot 004: Dud
null at .005-.006 looks good then too much Bz

For Shot 004:
IC_EF4 = -985A

May 27 1994 09:47:01:260AM940527005John GoetzShot 005: Fizzle
breakdown at .006sec
Halpha lasts until .035sec
scatterplot says too much gas

For Shot 006:
lower P_0 to 1.0e-5

May 27 1994 10:02:06:030AM940527006John GoetzShot 006: Plasma
rampdown
Ip=.65; nel=7e19

For Shot 007:
lower PULSE_GAS_3 after 0.2 sec (to raise temperature)

May 27 1994 10:23:42:430AM940527007John GoetzShot 007: Plasma
dud
very small null

For Shot 008:
change IC_EF2L and IC_EF2U to -1650A from -1700A to try
to make the null better

May 27 1994 10:59:42:000AM940527008John GoetzShot 008: Dud
Bz too positive because of the EF2 change
radial field better

For Shot 009:
IC_EF4 to -1015A for vertical field change

May 27 1994 11:00:43:870AM940527009John GoetzShot 009: Plasma
Ip=.65; nel=7e19; Te(0)=1.5

For Shot 010:
IP=-740000

May 27 1994 11:18:57:050AM940527010John GoetzShot 010: Plasma
Ip=.75; nel=8e19; Te(0)=1.6
very triangular

For Shot 010:
IP=-840000
PULSE_GAS_1 moved to 0.65sec

May 27 1994 11:31:59:310AM940527011John GoetzShot 011: Plasma
Ip=.85; nel=7.4e19; Te(0)=1.6
argon induced disruption at 0.74

For Shot 012:
PULSE_GAS_3 lowered after 0.2 to reduce density

May 27 1994 11:39:49:610AM940527012John GoetzShot 012: dud
ACK failure - no shot

For Shot 013:
no changes

May 27 1994 11:58:13:030AM940527013John GoetzShot 013: plasma
Ip=0.85; nel=7.7e19; Te(0)=1.9
disruptive late during rampdown - argon related

For Shot 014:
IP=-550000
B_SIDE_LOWER plenum pressure = 2.4PSIA

May 27 1994 12:09:26:460PM940527014John GoetzShot 014: plasma
Ip=0.58; nel=5e19; Te(0)=1.8
less argon - good rampdown

For Shot 015:
IP=-520000

May 27 1994 12:29:25:530PM940527015John GoetzShot 015: plasma
Ip=0.55; nel=5e19; Te(0)=1.8
a bit of moly from .1 to .15

For Shot 016:
IP=-420000
a little more PULSE_GAS_3 early

May 27 1994 12:50:20:020PM940527016John GoetzShot 016: dud
Horne's opinion: Ripple in OH1 causes lump of Bz at the wrong
time.

For Shot 017:
P_0=1.2e-5

May 27 1994 01:02:01:630PM940527017John GoetzShot 017: plasma
Ip=.46; nel=5e19; Te(0)=1.5

For Shot 018:
reload 940527013
IP=-800000
low power RF

May 27 1994 01:19:38:710PM940527018John GoetzShot 018: plasma
Ip=.81; nel=7.5e19; Te(0)=1.8 [ 2.1 after RF ]

For Shot 019:
P_ZCUR(2)=1.5

May 27 1994 01:36:38:390PM940527019John GoetzShot 019: plasma
Ip=.81; nel=7.1e19; Te(0)=1.8 [ 2.15 after RF ]

For Shot 020:
program .01m step in ZCUR from .65 to .71sec
turned off RF

May 27 1994 01:54:54:600PM940527020John GoetzShot 020: plasma
Ip=.81; nel=7.2e19; Te(0)=2.0
disruption at .74 - programmed Z step happens, but on down
jump, the plasma oversteps and gets thrown out of the
machine

For Shot 021:
low power RF
turn off integral gain on ZCUR (check for cause of ZCUR oscill.)

May 27 1994 02:01:47:780PM940527021John GoetzShot 021: fizzle
breakdown at .005sec
Halpha to .03sec
null just about the same as always

For Shot 022:
P_0=1.1e-5

May 27 1994 02:19:02:400PM940527022John GoetzShot 022: dud
null significantly worse - bad in OH2L corner
oscillations in OH2's and OH1

For Shot 023:
lower P gain on IC_OH2U to 2 at -.03 to try and reduce oscill.

May 27 1994 02:37:37:740PM940527023John GoetzShot 023: plasma
Ip=.80; nel=6.4e19; Te(0)=1.9 (2.25 RF)
natural injection at .62

For Shot 024:
raise PULSE_GAS_3 after .2 sec

May 27 1994 02:47:15:600PM940527024John GoetzShot 024: dud
Br too negative? Bz too positive?

For Shot 025:
BR_0 offset to -.003
IC_EF4 to -1025A
P_0=1.2e-5

May 27 1994 03:02:27:740PM940527025John GoetzShot 025: plasma
Ip=.81; nel=7e19; Te(0)=1.7 (2.0 RF)

For Shot 026:
RF on at .5sec

May 27 1994 03:14:58:620PM940527026John GoetzShot 026: plasma
Ip=.81; nel=8.2e19; Te(0)=1.7 (2.0 RF)

For Shot 027:
no changes

May 27 1994 03:29:25:360PM940527027John GoetzShot 027: plasma
Ip=.81; nel=8.0e19; Te(0)=1.5 (1.9 RF)

For Shot 028:
notch ZCUR derivative gain from .65 to .70

May 27 1994 03:47:29:460PM940527028John GoetzShot 028: no shot
alternator voltage ramped down just before PULSE

For Shot 029:
no changes

May 27 1994 03:59:20:020PM940527029John GoetzShot 029: dud
Bz too positive

For Shot 030:
IC_EF4 to -1035A

May 27 1994 04:14:11:990PM940527030John GoetzShot 030: plasma
Ip=.81; nel=8.0e19; Te(0)=
no apparant change in ZCUR due to the gain switch

For Shot 031:
drop ZCUR derivative gain to 0 from .65 to .70

May 27 1994 04:29:17:600PM940527031John GoetzShot 031: plasma
Ip=.81; nel=8.1e19; Te(0)=1.3
no change in ZCUR due to the gain switch

For Shot 032:
drop ZCUR proportional gain to 0.5 from .65 to .70
return ZCUR derivative gain to 1 from .65 to .70
PULSE_GAS_1 to 0.4sec

May 27 1994 04:42:41:470PM940527032John GoetzShot 032: plasma
Ip=.81; nel=7.9e19; Te(0)=1.5
no change in ZCUR oscillation due to the gain switch

For Shot 033:
drop ZCUR proportional gain to 0 from .65 to .70
change RCUR ramp from .1 to .2

May 27 1994 04:56:11:440PM940527033John GoetzShot 033: plasma
Ip=.81; nel=7.4e19; Te(0)=1.5
ZCUR oscillation decreases a little, z position droops 2mm

For Shot 034:
drop ZCUR derivative gain to 0 from .60 to .70
for all previous shots that mention ZCUR gain switches, the
times should be .60 and .70

May 27 1994 05:16:14:460PM940527034John GoetzShot 034: plasma
Ip=.81; nel=7.5e19; Te(0)=1.8
ZCUR oscillation decreases a little more, z position droops 4mm

Engineering Operator Comments
ShotTimeTypeStatusComment
108:39:42:300AMPlasmaOkdud 08:40
208:52:53:780AMPlasmaOk
309:06:12:660AMPlasmaBadFizzle No faults
409:21:21:010AMPlasmaOk
509:34:42:400AMPlasmaOkdud No faults
609:46:36:070AMPlasmaOkgreat shot
710:05:58:680AMPlasmaOk
810:24:43:170AMPlasmaOk
910:38:51:720AMPlasmaOkGood 650KA Ip
1010:59:21:960AMPlasmaOk2 in a row
1111:19:34:310AMPlasmaOkplasma disrupt
1211:32:52:720AMPlasmaBadIGOR ACK failure on transition to pulse
1311:40:42:720AMPlasmaOkplasma
1411:57:50:070AMPlasmaOkGood 580KA Ip
1512:16:40:080PMPlasmaOkplasma
1612:37:31:760PMPlasmaOk
1712:49:57:770PMPlasmaOkplasma shot No faults.
1801:06:06:590PMPlasmaOkGood shot No faults
1901:23:08:940PMPlasmaOkPLASMA SHOT NO FAULTS
2001:36:21:820PMPlasmaOkPLASMA SHOT O.K.
2101:53:54:660PMPlasmaBadDUD NO FAULTS.
2202:04:12:900PMPlasmaBadDUD NO FAULTS.
2302:17:40:180PMPlasmaOkNO FAULTS
2402:33:53:950PMPlasmaOkDUD NO FAULTS
2502:47:51:000PMPlasmaOkNO FAULTS
2603:04:06:190PMPlasmaOkGOOD, NO FAULTS
2703:16:12:880PMPlasmaOkGOOD SHOT NO FAULTS.
2803:29:54:070PMPlasmaBadALT VOLTAGE FAULT
2903:48:31:180PMPlasmaOkGOOD, NO FAULTS
3004:00:02:380PMPlasmaOkGOOD SHOT
3104:15:24:260PMPlasmaOkGOOD SHOT NO FAULTS.
3204:29:48:580PMPlasmaOkGOOD SHOT NO FAULTS
3304:44:03:670PMPlasmaOkGOOD, NO FAULTS
3405:01:02:430PMPlasmaOkNO FAULTS