Alcator C-Mod Run 940603 Information

Back to runs

Miniproposals
Miniproposal:046
Date Filed: 4/7/1994
Title:Ohmic Confinement
First Author:Martin Greenwald
Session Leader:Martin Greenwald (shots 1-20)

Operators
Session leader(s):Martin Greenwald
Physics operator(s):John Goetz
Engineering operator(s):Joe Daigle,Vinny Bertolino

Engineering Operator Run Comment
ohmic transport

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:10:790PM
Author: To Be Determined
Run of 940603
Greenwald, Goetz

Plan: Ohmic Confinement Run - Fill in data base at lower current and kappa
- D2, limited
- allowing comparison w/H2 data from 93
- run "Alcator C" like plasmas if possible

Summary: A good fraction of the run plan was accomplished. Startup was
slightly rockier than the previous couple of days and a power supply problem
took about 2 hours to diagnose and fix. Good shots - suitable for analysis
are listed below. We got most of the kappa scan, only missing kappa = 1.
As we discovered last summer, it is hard to control the density for limiter
discharges.

The following are good shots for transport analysis:

Shot Ip Kappa nebar
005 .8 1.5-1.6 1.3-1.7
006 .8 1.3-1.6 1.4-1.6
007 .8 1.3-1.5 1.4-1.6
012 .8 1.4-1.5 1.2-1.6
013 .8 1.4 1.2-1.5
014 .8 1.45 1.1-1.7
015 .6 1.4 1.0-1.7
016 .4 1.3 0.7-1.1
017 .4 1.35 0.7-1.2
018 .4 1.2 0.8-1.1
019 .6 1.25-1.3 0.9-1.1
020 .8 1.25 1.1-1.4

Physics Operator Summaries
Entered: Jul 7 2004 04:36:51:677PM
Author: To Be Determined
Physics operator summary for 940603

EO: Bertilino/Daigle
PO: Goetz
SL: Greenwald

Run 940603 was in support of Mini-Proposal #046 - Ohmic Transport. This run
was intended to extend the range of the Ohmic confinement database. The
parameter range to be explored was: 1 < kappa < 1.5; 0.4 < Ip < 0.8;
1 < nebar < 2x10^20; and 0.17 < a < .22. The run started with a reload of
shot 940601021 which was a shot with 0.8MA, nebar = 1.2x10^20 and kappa = 1.5.
In the end discharges with 1.2 < kappa < 1.5 and 0.4 < Ip < 0.8 MA were
obtained and some holes in the database were filled.

The pulse length was extended to 1.0 sec to allow more time for good data
acquisition. The gain switches in the IP controller were changed to 1.0 sec,
the IC_EF1's were extended to 1.25 sec, and the IC_EF2's were extended to 1.3
sec. The invert times for the PF supplies were moved to 1.4 sec and the time
for TF invert was set at 1.1 sec.

Another slow start to the day. The run started Dud-fizzle-disruptive plasma-
Dud. After this, RF assist was called for at a level of 10kW. The next few
shots show a feature on the Halpha trace indicative of bumping into something
on the outboard side of the machine. Shot 008 did not make it through this
bump. Most of the rest of the shots also had this feature but made it through.
The fill pressure was raised to try and slow the current rise but this remedy
obviously was not a remedy. Only on the last three or so shots was this
feature not present in the current rises.

Kappa was changed by using the IC_EF1 controllers. The KAPPA predictor was
working and reliably determining kappa. This controller was not turned on
though. It is recommended that a controller built of the EF1's should be
turned soon. Estimates for the changes made in EF1 are:
@ 0.4 MA a change of +1250A gives a change of -.15 in kappa
@ 0.6 MA a change of +2000A gives a change of -.1 in kappa
@ 0.8 MA a change of +3000A gives a change of -.2 in kappa
Also RCUR was moved in as the current was decreased to help out with the
elongation.

Segment 2 was loaded with the controllers from Segment 1 and on Shot 017,
Segment 2 was turned on at 1.1 sec. For Shot 018, the P's were made identical.
All seemed to work well with the segment switching as nothing really bad
happened. Care should be taken to make sure that the things that are not
supposed to change over segments don't. If you do not want segment switching
do not use a shot after 940603017 without turning off segment 2.

Engineering today: Blown fuse after shot 009 in the OH2L supply and the same
fuse blew on the precharge for shot 010 resulting in the loss of the
shot. The repair turned out to be a bad gate drive board (the gate
was on at all times). While this repair was being affected, the Ross
relays were out and EF1L became too warm. Total lost time due to
repair and recool was approximately two hours.

Scorecard: 20 shots = 14 plasmas + 3 fizzles + 2 duds + 1 power supply dud

Shot summary for Run 940603

Reload of 940601021

Changes:
Draw Ip flattop to 1.0 sec
Draw Ip controller gain switches to 1.0 sec
Extend IC_EF1U and IC_EF1L to 1.25 sec
Extend IC_EF2U and IC_EF2L to 1.3 sec
Moved TF invert time to 1.1 sec and all PF invert times to 1.4 sec

Shot change result
____ _____ ______
1 see above dud
2 IC_EF4 = -1020A fizzle
3 P_0=1.0e-5 plasma
4 no changes dud
5 IC_EF4=-1015A; RF assist of 10-20kW at breakdonw plasma
6 IC_EF1's to 2000A at 0.4sec; RCUR to 0.66 after 0.4 sec plasma
7 lower PULSE_GAS_3 early; add second pulse to PULSE_GAS_1
at 0.5; IC_EF1's to 2250 @ 0.4 and 1750 @ 1.0 plasma
8 raise PULSE_GAS_3 late; add third pulse to PULSE_GAS_1 at 0.7
ICEF1's to 1250A @ 0.4 and 3000A @ 1.25 fizzle
9 no changes - try again plasma
10 P_0=1.1e-5; less PULSE_GAS_3 early; IC_EF1's to 500A @ 0.4 ps dud
11 IC_EF4 to -990A; fizzle detector off at 1.5 and reset fizzle
detector threshold to 51.3 ka ( 75 mv) fizzle
12 IC_EF4 back to -1015A plasma
13 IC_EF4=-1025; IC_EF1's=3750A @ 1.2; PULSE_GAS_1 third pulse
decreased; PULSE_GAS_3 lowered early plasma
14 lower PULSE_GAS_3 early and raise to 50V @ 0.5sec plasma
15 IP=-600000; IC_EF1'S = 3000A @ 1.2; plasma
16 IP=-390000; IC_EF1's to 2000@1.2 and 750 @0.4; PULSE_GAS_3
raised late plasma
17 RCUR=0.65; IC_EF1's =2500 @ 1.2 and 500 @ 0.4; turn on
segment 2 (which was loaded with segment 1); raise
PULSE_GAS_3 early and lower late plasma
18 IC_EF1's = 1000 @ 0.4 and 3750 @ 1.2; RCUR=0.645; raise
PULSE_GAS_3 early and lower late plasma
19 IP=-600000; IC_EF1's = 5000A @ 1.2 and 250 @ 0.4; RCUR=0.655 plasma
20 IP=-800000; IC_EF1's = 6500A @ 1.2 and 5000A @ 0.7; RCUR=0.66
a little more PULSE_GAS_3 plasma

Session Leader Comments

Physics Operator Comments
Jun 3 1994 08:33:23:430AMJohn GoetzRUN 940603

Mini-Proposal 046 -- Ohmic Transport

This run is designed to extend the range of the Ohmic confinement
database. The parameter range to be covered:
1 < kappa < 1.5
0.4 < Ip < 0.8
1 < nebar < 2 X 10^20
.17 < a < .22

The plan is to scan density and current at each kappa consistent with
the q limit. The run will start with a reload of 940601021 (no changes).

Jun 3 1994 09:25:22:850AM940603001John GoetzFor Shot 940603001:

Draw Ip out to 1.0 sec
Draw Ip controller gain switches to 1.0 sec
Extend IC_EF1U and IC_EF1L to 1.25 sec
Extend IC_EF2U and IC_EF2L to 1.3 sec
Move TF invert time to 1.1 sec and all PF invert times to 1.4 sec

Shot 940603001:
Dud
Bz a little too positive?

For Shot 940603002:
lower IC_EF4 to -1020A

Jun 3 1994 09:39:49:430AM940603002John GoetzFor Shot 940603001:

Draw Ip out to 1.0 sec
Draw Ip controller gain switches to 1.0 sec
Shot 940603002:
Fizzle
Breakdown at .006; Halpha until .05; nel = 6x10^18
a few bounces here and there

For Shot 940603003:
lower P_0 to 1.0e-5

Jun 3 1994 09:48:06:290AM940603003John GoetzFor Shot 940603001:

Draw Ip out to 1.0 sec
Draw Ip controller gain switches to 1.0 sec
Shot 940603003:
Plasma - very disruptive after .08
maybe too much gas from inner wall? puff?

For Shot 940603004:
no changes - try again

Jun 3 1994 10:05:51:800AM940603004John GoetzFor Shot 940603001:

Draw Ip out to 1.0 sec
Draw Ip controller gain switches to 1.0 sec
Shot 940603004:
Dud
Bz takes a negative jump right at the nominal breakdown time

For Shot 940603005:
IC_EF4=-1015A to get BZ a bit more positive
RF assist at breakdown - 10 or 20 kW

Jun 3 1994 10:35:32:110AM940603005John GoetzShot 940603005:
Plasma Ip=.80; lasts until 1.2 sec; rampdown at 1.0sec
lots of injections
inner gap from 0.5sec on
diverts with x-point on inner nose
no RF heating so lower beta and a different plasma than 940601021

For Shot 940603006:
IC_EF1's to 2000A @ 0.4sec
RCUR to 0.66 after 0.4 sec

Jun 3 1994 10:54:54:940AM940603006John GoetzShot 940603006:
Plasma Ip=.80; successful rampdown at 1.0sec
no inner gap until after 0.8
kappa ramps from 1.2 @ 0.4 to 1.5 @ 1.0 sec

For Shot 940603007:
IC_EF1's to 2250A @ 0.4sec and 1750 @ 1.0 to try and hold
kappa at 1.4
add second pulse to PULSE_GAS_1 at 0.5 sec ( .01 sec wide )
lower PULSE_GAS_3 early to try and get a density ramp

Jun 3 1994 11:13:28:960AM940603007John GoetzShot 940603007:
Plasma Ip=.80; successful rampdown at 1.0sec
no inner gap until after 0.8
kappa ramps from 1.2 @ 0.4 to 1.5 @ 1.0 sec

For Shot 940603008:
IC_EF1's to 1250A @ 0.4sec and 3000 @ 1.25 to try and hold
kappa at 1.4
add third pulse to PULSE_GAS_1 at 0.7 sec ( .01 sec wide )
lower PULSE_GAS_3 early to try and get a density ramp and
raise late to get a better density ramp

Jun 3 1994 11:32:58:900AM940603008John GoetzShot 940603008:
Fizzle - lasts until .035 - hits something at .016

For Shot 940603009:
no changes - try again

Jun 3 1994 11:51:07:030AM940603009John GoetzShot 940603009:
Plasma
Disrupts at 1.16 sec
kappa ramp better, i.e. flatter
density has bump near 0.5

For Shot 940603010:
IC_EF1's to 500A @ 0.4sec
less PULSE_GAS_3 early to get a better density ramp
P_0=1.1e-5 to try and slow current rise

Jun 3 1994 12:07:35:820PM940603010John GoetzShot 940603010:
Power supply failure - no commutation supplies went
Fuse blown on shot 009 disruption blew again - maybe indicative
of a bad SCR

For Shot 940603011:
scatterplot shows Bz too negative throughout breakdown, probably
the cause of the current rise trouble
IC_EF4 to -990A

Jun 3 1994 02:07:31:520PM940603011John GoetzShot 940603011:
turns out it was a bad gate board in the OH2L supply - the
gate was always on.
fizzle - Bz too positive

For Shot 940603012:
IC_EF4 back to -1015A

Jun 3 1994 02:34:14:350PM940603012John GoetzShot 940603012:
Plasma - Ip=.81
kappa flat from 0.6 to 1.0 sec at about 1.5
not much of a density ramp over this time
breakdown early - Bz a little positive - hit something at .028

For Shot 940603013:
IC_EF4 to -1025A
IC_EF1's to 3750A @ 1.2 to lower elongation
lower PULSE_GAS_3 early to get a better density ramp
third PULSE_GAS_1 lowered to 90V

Jun 3 1994 02:54:58:240PM940603013John GoetzShot 940603013:
Plasma - Ip=.81
kappa flat from 0.6 to 1.0 sec at about 1.44
not much of a density ramp over this time


For Shot 940603014:
lower PULSE_GAS_3 early and raise to 50V @ 0.5 sec
to get a better density ramp

Jun 3 1994 03:05:54:760PM940603014John GoetzShot 940603014:
Plasma - Ip=.81 - disrupts @ 1.19
kappa flat from 0.6 to 1.0 sec at about 1.44
small density ramp up and down at this time

For Shot 940603015:
IP=-600000
IC_EF1's = 3000 @ 1.2 (try to keep elongation the same as 014)
draw a KAPPA of 0.2 @ 1.0 to test controller

Jun 3 1994 03:27:15:980PM940603015John GoetzShot 940603015:
Plasma - Ip=.63 - disrupts @ 1.17
kappa from 1.4 at 0.5 to 1.45 at 1.0 sec
good density ramp

For Shot 940603016:
IP=-390000
IC_EF1's = 2000 @ 1.2 and 750 @ 0.4
(try to keep elongation the same as 014)
raise PULSE_GAS_3 up late

Jun 3 1994 03:53:47:440PM940603016John GoetzShot 940603016:
Plasma - Ip=.4 - disrupts @ 71
kappa from 1.3 from 0.4 onward
too much density - too heavy on the gas puff

For Shot 940603017:
IC_EF1's = 2500 @ 1.2 and 500 @ 0.4
raise PULSE_GAS_3 early and lower it late
remove third pulse on PULSE_GAS_1
RCUR = 0.65 from 0.4 onward
load segment 2 with segment 1 and turn on at 1.1 sec

Jun 3 1994 04:07:38:160PM940603017John GoetzShot 940603017:
Plasma - Ip=.4 - disrupts @ 1.1
kappa from 1.35 from 0.4 onward
too much density - too heavy on the gas puff after 0.8

For Shot 940603018:
IC_EF1's = 3750 @ 1.2 and 1000 @ 0.4
raise PULSE_GAS_3 early and lower it late
RCUR = 0.645 from 0.4 onward

Jun 3 1994 04:31:07:800PM940603018John GoetzShot 940603018:
Plasma - Ip=.42 - almost makes it down
kappa from 1.2 @ 0.5 to 1.15 @ 1.0
density good - nebar ~ 1x10^20

For Shot 940603019:
IP=-600000
IC_EF1's = 5000 @ 1.2 and 250 @ 0.4
RCUR = 0.655 from 0.4 onward

Jun 3 1994 04:57:23:770PM940603019John GoetzShot 940603019:
Plasma - Ip=.62 - almost makes it down
kappa from 1.3 @ 0.65 to 1.2 @ 1.0
density good - nebar ~ 1.1x10^20

For Shot 940603020:
IP=-800000
IC_EF1's = 6500 @ 1.2 and 5000 @ 0.7
RCUR = 0.66 from 0.4 onward
a little bit more PULSE_GAS_3

Jun 3 1994 05:12:34:350PM940603020John GoetzShot 940603020:
Plasma - Ip=.80 - almost makes it down
kappa = 1.25 from 0.5 to 1.0
density good - nebar ~ 1.0x10^20 to 1.5x10^20

Engineering Operator Comments
ShotTimeTypeStatusComment
109:13:13:530AMPlasmaOkno faults
209:28:03:250AMPlasmaOkno faults
309:39:55:010AMPlasmaOkno faults
409:51:54:370AMPlasmaOkno faults
510:07:38:720AMPlasmaOkno faults
610:35:11:740AMPlasmaOkoh1 comm fault in inversion
710:54:37:730AMPlasmaOkno faults
811:13:34:880AMPlasmaOkno faults
911:29:02:130AMPlasmaOkcomm fail oh1 and oh2s after disruption
1011:52:37:050AMPlasmaBadoh2l failed early
1101:54:35:460PMPlasmaOkdud no faults.
1202:09:12:780PMPlasmaOkcomm fault oh2's ef1's oh1.
1302:30:07:870PMPlasmaOkcomm faults oh1 oh2u
1402:48:57:030PMPlasmaOkcom fault oh1
1503:06:51:270PMPlasmaOkoh1 com. fault
1603:27:00:220PMPlasmaOkNO faults
1703:48:53:990PMPlasmaOkoh1 com. fault
1804:13:14:470PMPlasmaOkNo faults
1904:32:08:360PMPlasmaOkNo faults.
2004:57:56:690PMPlasmaOkNo faults.