| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Yuichi Takase |
| Physics operator(s): | Steve Golovato |
| Engineering operator(s): | Vinny Bertolino,Frank Silva |
| Engineering Operator Run Comment |
| undecided |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:10:993PM |
| Author: To Be Determined |
| Run Summary for 940601 SL: Takase PO: Golovato EO: Silva/Bertolino MP059 RF Heating (> 1 MW) The objective of this proposal is to perform parameter scans at a power level of over 1 MW. Todays objective was to perform the following scans in inner-wall limited plasmas, starting from a reload of 940602019: 1. Density scan 2. Current scan 3. Toroidal field scan We have completed the lower density half of density scan, but had difficulty completing the high density half. The reason for this difficulty is the unexpected difficulty trying to tune to high density plasmas. There were additional problems with the hybrid (see physics operator's summary) and a general difficulty to get stable high density plasmas. Initial analysis of today's results indicate that the heating (stored energy increase) was nearly independent of density. Another indication is that the heating may be better at higher current (although we did not intentionally run different currents, we got them due to the hybrid problem). These results are consistent with L-mode scaling. On shot 005, we observed an ELM-free H-mode which turned into an ELMy H-mode and back to L-mode. The RF power did not trip, but because of large loading change, the RF power dropped by a half during H-mode. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:51:693PM |
| Author: To Be Determined |
| Physics Operator Summary - Run 940608 SL - Takase PO - Golovato EO - Silva/Bertolino The main goals of the run were to do density and current scans at high rf power with inner wall limited plasmas. We started with shot 940602019, our best shot from last week. We got plasmas from the first shot and every shot except shot 12, which was an inexplicable fizzle. We accomplished a density scan in the downward direction over shots 3-13, but had trouble matching to the plasma at higher than nl_04 ~ 8.e19 cm-2. Shots 14-16 had nl_04 ~> 9.e19 cm-2 but no high power rf. All shots up to this point were at 800 ka. From shot 17 onward, we had a problem with the hybrid. The current dropped in two steps, 710 ka on shot 17 and about 650 from then on. The hybrid in fact thought the currennt was still 800 ka held it constant at what turned out to be the incorrect value. The Rogowskis and reconstructions all agreed that the current was in fact the lower value. The problem was thought to be a spontaneous change in gain of one of the imfamous Livermore isoamps on the hybrid inputs, which required cell access to remedy and was left for after the run. The problem turned out to be a bad cable carrying the current signal to all current referenced hybrid wires, which therefore all had a value of zero, that is, there was no feedback control on these wires. The LEMO connector had unscrewed and no longer made contact, an advertisement for crimped connectors. This would have been picked up in the plasma control if we hadn't been running such vanilla plasmas, symmetric up-down and positioned at the nominal R-Z center. The current dropped because the now unloaded isoamp had an effectively higher gain, so the current appeared to the hybrid to be higher than it actually was. This is another "feature" of the Livermore isoamps. The problem should be fixed for tomorrow but we should all be more sympathetic to Horne's desire to get rid of these isoamps. Running at lower current for the rest of the run, we had trouble both in running at higher density and in tuning to the higher density. We appeared to have a density limit at 650 ka at nl_04 ~ 1.e20 cm-2, where we observed a locked mode which led sooner or later, depending on the shot, to a disruption (see shots 20 and 21 for example). We also had disruptions at the lowest densities we ran, nl_04 <~ 4.e19 cm-2. These were at 800 ka and quite potent, so beware when running at low density, particularly during the rampdown, where added gas can help avoid a late disruption (see shots 7-9). Conversely, at high density and lower current, too much gas in the rampdown often led to the locked mode and disruption (see shots 27 and 28). Shot-by-shot comments are in the logbook under the physics_operator topic. The shot accounting was 27 plasmas and one fizzle. |
| Session Leader Comments | |||
| Jun 8 1994 08:47:24:080AM | Yuichi Takase | MP059 RF Heating
Parameter scans (inner-wall limited plasma): 1. Density scan 2. Current scan 3. Toroidal field scan (possibly) Start from 940602019 | |
| Jun 8 1994 09:19:41:860AM | 940608001 | Yuichi Takase | Early disruption, dirty shot.
|
| Jun 8 1994 09:45:22:330AM | 940608002 | Yuichi Takase | Good shot.
Ip=0.8, nel_04=8-9, Prf=1.4 |
| Jun 8 1994 09:47:44:130AM | 940608003 | Yuichi Takase | Good shot, almost the same as 002.
Ip=0.8, nel_04=8-9, Prf=1.4 |
| Jun 8 1994 10:06:09:340AM | 940608004 | Yuichi Takase | Good shot, RF pulse 0.65-0.75sec.
Ip=0.8, nel_04=8-9, Prf=1.6-1.3. |
| Jun 8 1994 10:33:11:200AM | 940608005 | Yuichi Takase | Good shot, RF pulse 0.65-0.75sec.
H-mode (ELM-free to ELMy), RF survived, but power halved. Ip=0.8, nel_04=7-10, Prf=1.5-0.85. |
| Jun 8 1994 10:53:46:190AM | 940608006 | Yuichi Takase | RF interrupts.
Tuning looks OK, probably voltage limit because of low loading (40kV). Ip=0.8, nel_04=6.5, Prf=1.7 (interrupts). |
| Jun 8 1994 11:06:58:870AM | 940608007 | Yuichi Takase | RF interrupts.
Ip=0.8, nel_04=5.5, Prf=1.3-1.1 (interrupts). |
| Jun 8 1994 11:29:49:170AM | 940608008 | Yuichi Takase | RF interrupts.
Ip=0.8, nel_04=4.5, Prf=1.0-1.2 (interrupts). |
| Jun 8 1994 11:36:40:500AM | 940608009 | Yuichi Takase | Disrupted at 0.6sec, no high power RF.
|
| Jun 8 1994 12:03:20:450PM | 940608010 | Yuichi Takase | Disrupted during Ip rampdown.
Ip=0.8, nel_04=2.8, Prf=1.3 (interrupts). |
| Jun 8 1994 12:14:26:550PM | 940608011 | Yuichi Takase | Good shot again.
Ip=0.8, nel_04=6.0, Prf=1.4 (1 interrupt at the end). |
| Jun 8 1994 12:19:39:500PM | 940608012 | Yuichi Takase | Fizzle.
|
| Jun 8 1994 01:03:02:010PM | 940608013 | Yuichi Takase | Ip=0.8, nel_04=7.4-8.3, Prf=1.5.
|
| Jun 8 1994 01:04:00:260PM | 940608014 | Yuichi Takase | No high power RF (loading too high).
Ip=0.8, nel_04=9.2, Prf=0. |
| Jun 8 1994 01:35:11:530PM | 940608015 | Yuichi Takase | No high power RF (loading too high).
Ip=0.8, nel_04=8.9, Prf=0. |
| Jun 8 1994 01:35:32:600PM | 940608016 | Yuichi Takase | No high power RF (loading too high).
Still trying to tune. Ip=0.8, nel_04=9.4, Prf=0. |
| Jun 8 1994 01:54:20:300PM | 940608017 | Yuichi Takase | No high power RF (loading too high).
Still trying to tune. Ip=0.7, nel_04=10., Prf=0. |
| Jun 8 1994 02:13:03:870PM | 940608018 | Yuichi Takase | No high power RF (loading too high).
Still trying to tune. Ip=0.65, nel_04=9.3, Prf=0. |
| Jun 8 1994 03:15:19:460PM | 940608020 | Yuichi Takase | No high power RF.
Having HYBRID problems since shot 017, |
| Jun 8 1994 03:15:52:750PM | 940608021 | Yuichi Takase | A little better tuning, 100kW for a short time.
|
| Jun 8 1994 03:20:40:700PM | 940608022 | Yuichi Takase | Bad tune again.
Density lower nel_04=7 (reloaded shot 003). |
| Jun 8 1994 03:43:01:160PM | 940608023 | Yuichi Takase | Good RF pulse (back to original plasma and original tune).
Ip=0.68, nel_04=6.7-7.0, Prf=0.9-1.2. |
| Jun 8 1994 03:54:00:280PM | 940608024 | Yuichi Takase | Ip=0.68, nel_04=7.8, Prf=1.5.
|
| Jun 8 1994 04:22:02:690PM | 940608025 | Yuichi Takase | Disrupted, no RF.
|
| Jun 8 1994 04:22:42:130PM | 940608026 | Yuichi Takase | Disrupted, RF interrupts (15 Ohm loading).
|
| Jun 8 1994 04:55:49:530PM | 940608027 | Yuichi Takase | Disruptive plasma, no high power RF.
|
| Jun 8 1994 04:56:05:710PM | 940608028 | Yuichi Takase | Disruptive plasma, no high power RF.
|
| Jun 8 1994 05:08:36:320PM | 940608028 | Yuichi Takase | Plasma was OK, but lowish density (nel_04=6), no high power RF.
|
| Physics Operator Comments | |||
| Jun 8 1994 09:04:24:560AM | Steve Golovato | Run 940608 - ICRF in 1-2 MW Range
SL - Takase PO - Golovato EO - Silva ECDC in D 6-8am Run Goals - density , current scans at high rf power if time, H concentration scan and/or diverted discharge development Starting with shot 940602019, which was best previous shot, had 2 cm outer gap, limited on inner wall. Note that the current flattop ends at 800 ms on these shots Power supply incersion time at 800ms.. Running this way should allow more shots per day. | |
| Jun 8 1994 10:53:36:310AM | Steve Golovato | gas pre-fill set to 1.2e-5 from first shot.
| |
| Jun 8 1994 09:17:28:770AM | 940608001 | Steve Golovato | 9406080010 - 9:10am
Copied shot 940602019. Plasma, but disruptive, ended at 500ms, 600ka. |
| Jun 8 1994 09:35:49:060AM | 940608002 | Steve Golovato | 940608002 - try again, no changes.
Plasma. Good shot. 800ms,1.03s. |
| Jun 8 1994 09:45:13:750AM | 940608003 | Steve Golovato | 940608003 - again, no changes.1.01s.
|
| Jun 8 1994 10:05:28:960AM | 940608004 | Steve Golovato | 940608004- start density scan, starting at lower density.
Good shot, lower nl. 7.5e19, was 8.4e19. |
| Jun 8 1994 10:24:40:860AM | 940608005 | Steve Golovato | 940608005- gas set to 30V, from 34V.
nl04=7.e19 |
| Jun 8 1994 10:37:10:820AM | 940608006 | Steve Golovato | 940608006 - gas set to 26V.
nl04=6.4e19 |
| Jun 8 1994 11:01:34:350AM | 940608007 | Steve Golovato | 940608007 - nl04=5.4e19
had eliminated gas puff at 850ms for tom luke for this shot got disruption during current rampdown. will add it back for next shot.. |
| Jun 8 1994 11:06:34:320AM | 940608007 | Steve Golovato | 940608007 - gas puff set to 20V.
|
| Jun 8 1994 11:25:46:140AM | 940608008 | Steve Golovato | 940608008 - late puff put back at 850ms, 60V (was 80V).
continuous gas at 16V nl04=4.3e19. moly burst at about 690ms. |
| Jun 8 1994 11:26:35:350AM | 940608008 | Steve Golovato | 940608008 - late puff allowed soft landing at 1.15s.
|
| Jun 8 1994 11:36:23:120AM | 940608009 | Steve Golovato | 940608009 - retake last shot, hope for no moly event.
disrupted early at 620ms, before rf pulse. this is as low as we'll go in density. |
| Jun 8 1994 11:54:43:910AM | 940608010 | Steve Golovato | 940608010 - going back to shot 006, midway back to starting density.
puff set to 26V. late puff set back to 60V. following previous disruption, got low density, nl04=2.75e19. disrupted at 865ms. |
| Jun 8 1994 12:09:24:790PM | 940608011 | Steve Golovato | 940608011 - raised puff voltage to 34V, increased late puff to 70V,
started it a little earlier. no disruption. things were getting at little scary, with large halo currents reported on the last two shots. nl04=5.6e19. |
| Jun 8 1994 12:28:13:080PM | 940608012 | Steve Golovato | 940608012 - raised puff to 40V.
fizzle. not clear why, breakdown looked like previous shot. |
| Jun 8 1994 12:39:58:440PM | 940608013 | Steve Golovato | 940608013 - try again.
worked. but almost didn't, current dropped between 18 and 20 ms, then continued rising. i'm told by horne and granetz in EXACTLY the same words that this is an exteme example of the "hutchinson hesitation". nl04= 7.4e19. |
| Jun 8 1994 12:54:45:530PM | 940608014 | Steve Golovato | 940608014 - puff at 50V.
worked again, n hesitation. nl04=9.25e19, but no high power rf. |
| Jun 8 1994 01:15:59:440PM | 940608015 | Steve Golovato | 940608015 - rf mis-tuned at this density, no high power pulse.
nl04=8.85e19. (incidentally, these nl's are at 650ms, when the high power rf turns on). disrupted a little early, at 965ms. |
| Jun 8 1994 01:30:00:730PM | 940608016 | Steve Golovato | 940608016 - try to get high power rf again.
no high power pulse. nl04=9.4e19 |
| Jun 8 1994 01:45:57:600PM | 940608017 | Steve Golovato | 940608017 - removing late puff, getting disruptions during rampdown
at these high gas puff levels. good plasma, still no rf. nl04=1.e20 |
| Jun 8 1994 01:50:49:400PM | 940608017 | Steve Golovato | 940608017 - current didn't reach 800ka, only got 710ka.
|
| Jun 8 1994 02:18:57:980PM | 940608018 | Steve Golovato | 940608018 - density creeping up, a moving target for tuning.
lowering puff to 46V. still no rf. nl04=9.1e19. curent flattop at 650ka. hybrid thinks the current is correct. perhaps an offset problem. |
| Jun 8 1994 02:34:31:520PM | 940608019 | Steve Golovato | 940608019- same thing, 650ka flattop when programmed for 800ka.
no rf. nl04=9.e19. hybrid thinks it is 800ka. must be gain in isoamp has changed. all other measures, rogowskis and reconstuctions, say 650ka. |
| Jun 8 1994 02:51:59:040PM | 940608020 | Steve Golovato | 940608020 - lowered puff to 40V. plasma disruptive starting
at 600ms. not clear why. still 650ka. |
| Jun 8 1994 02:56:38:820PM | 940608020 | Steve Golovato | 940608020 - locked mode at 617ms cause of problems (snipes reports).
|
| Jun 8 1994 03:06:34:380PM | 940608021 | Steve Golovato | 940608021- disrupted at 633ms. loacked mode again.
|
| Jun 8 1994 03:16:34:370PM | 940608022 | Steve Golovato | 940608022- reloaded shot 003. running it without any changes.
nl04=7.e19. still 650ka. |
| Jun 8 1994 03:19:45:960PM | 940608022 | Steve Golovato | 940608022 - looked like shot 003. going back to tuning for shot 003.
|
| Jun 8 1994 03:28:39:010PM | 940608023 | Steve Golovato | 940608023 - good shot, good rf. still 650ka.now start
increasing density more slowly so we can track tuning. |
| Jun 8 1994 03:43:10:340PM | 940608024 | Steve Golovato | 940608024 - gas to 42V from 39V.
current moving around a little, was 680ka last two shots. nl04=7.6e19. rf ran. |
| Jun 8 1994 04:02:06:410PM | 940608025 | Steve Golovato | 940608025 - gas to 44V.
640ka, disrupted at 615ms, probably locked mode again. |
| Jun 8 1994 04:02:40:200PM | 940608025 | Steve Golovato | 940608025 - gas to 44V.
640ka, disrupted at 615ms, probably locked mode again. density ramped to 1.e20 at disruption. |
| Jun 8 1994 04:16:39:340PM | 940608026 | Steve Golovato | 940608026 - gas programming changed so still peaks at 44V
but rises to this value more slowly, i.e., less total gas. get locked mode when nl04 hits about 1.e20, this time at 670ms. 640ka this shot. |
| Jun 8 1994 04:34:54:870PM | 940608027 | Steve Golovato | 940608027 - lowered gas to 40V max again, see what happens.
lost at 880ms. 660ka. nl04=7.8e19. |
| Jun 8 1994 04:44:00:220PM | 940608028 | Steve Golovato | 940608028 - got rid of late puff, may have caused late disruption
last shot. tweeked gas up a little to 41V peak. late puff prevents disruptions at low density, causes them at high density. shaking plasma (as seen on video monitor), typically happens with locked mode, this time at about 700ms. plasma ran to 960ms, 640ka. nl04=9.e19. oh1 failed in inversion. |
| Jun 8 1994 04:57:37:950PM | 940608029 | Steve Golovato | 940608029 - good shot but no high power rf. 680ka. nl04=6.5e19
after several disruptive shots, get much less density without changing gas, as happened this shot. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:07:58:820AM | Plasma | Ok | plasma disrupt |
| 2 | 09:20:15:950AM | Plasma | Ok | plasma |
| 3 | 09:37:47:830AM | Plasma | Ok | Plasma |
| 4 | 09:52:53:610AM | Plasma | Ok | plasma |
| 5 | 10:15:32:400AM | Plasma | Ok | plasma |
| 6 | 10:32:49:520AM | Plasma | Ok | plasma |
| 7 | 10:52:55:390AM | Plasma | Ok | small disruption |
| 8 | 11:11:39:460AM | Plasma | Ok | plasma |
| 9 | 11:28:37:690AM | Plasma | Ok | plasma disruption |
| 10 | 11:46:18:410AM | Plasma | Ok | plasma disruption |
| 11 | 12:00:17:480PM | Plasma | Ok | plasma disruption |
| 12 | 12:12:48:430PM | Plasma | Ok | no breakdown |
| 13 | 12:29:28:740PM | Plasma | Ok | no faults |
| 14 | 12:49:25:420PM | Plasma | Ok | plasma, comm fault oh1 after shot |
| 15 | 01:01:13:850PM | Plasma | Ok | comm fails in inversion |
| 16 | 01:19:37:060PM | Plasma | Ok | no faults |
| 17 | 01:40:10:980PM | Plasma | Ok | oh1 comm fault in inversion |
| 18 | 02:00:23:710PM | Plasma | Ok | no faults |
| 19 | 02:15:36:600PM | Plasma | Ok | no faults |
| 20 | 02:36:14:990PM | Plasma | Ok | no faults |
| 21 | 02:51:49:780PM | Plasma | Ok | no faults |
| 22 | 03:08:48:610PM | Plasma | Ok | no faults |
| 23 | 03:23:16:740PM | Plasma | Ok | no faults |
| 24 | 03:37:59:080PM | Plasma | Ok | no faults |
| 25 | 03:56:01:730PM | Plasma | Ok | no faults |
| 26 | 04:10:09:490PM | Plasma | Ok | no faults |
| 27 | 04:26:11:950PM | Plasma | Ok | no faults |
| 28 | 04:38:01:210PM | Plasma | Ok | oh1 comm fault in inversion |
| 29 | 04:52:51:250PM | Plasma | Ok | no faults |