Alcator C-Mod Run 940614 Information

Back to runs

Miniproposals
Miniproposal:049
Date Filed: 4/8/1994
Title:2D Neutral Density Profile Measurements by Charge Exchange Recombination
First Author:John Rice
Session Leader:Francesca Bombarda (shots 1-24)

Operators
Session leader(s):Francesca Bombarda
Physics operator(s):Joseph Snipes
Engineering operator(s):Steve Fairfax

Engineering Operator Run Comment
049- 2-D Neutral Profile

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:11:180PM
Author: To Be Determined
The purpose of run 940614 was to try to measure 2D neutral density profiles
by observations of argon and carbon lines populated by charge exchange
recombination with intrinsic neutral deuterium. The key to the argon
observations is the presence of hydrogen-like argon in a region with high
neutral density. This requires fast transport from the core with a central
electron temperature near 1800 eV. Since we were restricted to 5 T operation,
this required running at low density, which is hard to control reproducibly.
The first 11 shots of the run were devoted to limited discharges. By shot 007
a suitable set of conditions was reached and 5 similar shots were obtained.
There was a slight indication of charge exchange at -18 cm and very little
at +17 cm for shots 007 through 011.
Beginning with shot 012, divertor operation was attempted. These plasmas
were very difficult to control, from the point of view of constant density at
nel = 5 x 10^19. By shot 018 an acceptable discharge was achieved, although
the density was a bit high, and it terminated in disruption. Shots 018-024
were similar in this regard, but the argon level through most of the shots
was very low. However, at around 700 ms, when the plasmas were diverted, the
argon seemed to rise rapidly, along with the electron density, ending in
disruption.
In these diverted shots there was clear evidence of charge exchange in the
bottom of the torus (-19.5 cm) which was not evident at the top (+17 cm).

The number of shots was reduced by very slow cooling of the TF during the
first half of the run. More reliable divertor operation would be desirable,
including improved understanding of why the first 2 argon puffs were not
penetrating, and why the third (smaller) puff at 700 ms seemed to be too
large.

Physics Operator Summaries
Entered: Jul 7 2004 04:36:51:897PM
Author: To Be Determined

From: PHYSOP::SNIPES
Date: 14-JUN-1994 18:57:07
Description: Physics Operator's Run Summary 940614

Overall, it was a reasonably good run. We started with Fairfax's Fiducial (FF)
copy of shot 940603015. It fizzled. Then, we copied shot 940603019 and it
went very well. I recommend that Fairfax change his fiducial to that shot.
Then, we had 9 more very similar plasmas, changing only the D and Ar
programming slightly. For shot 12, we copied shot 940610023 to try the same
experiment in diverted discharges, but with the D and Ar programming from
shot 940614011. It went o.k., but disrupted in the ramp down. We then
extended the density for the longer discharges. The plasmas continued to
disrupt during the flattop around 0.7 to 0.8 sec. Then, shot 16 fizzled.
We then tried changing the EF4 current at breakdown both +/- 15 A (1 mT) with
success both ways. So, it was not that sentitive to the EF4 level. Changes
were also tried in the RXL gain and timing and in the gas. Disruptions
continued. Finally, we turned down the Ar levels gradually and the plasmas
began to last longer. The last discharge lasted until 1.1 sec, just after a
Moly laser blowoff at 1 sec. Locked modes were observed preceding many of the
high density disruptions, leading me to believe they were radiation dominated.
Thus, it seems that the levels of Ar in the diverted discharges were too
high for these plasmas to handle. The Ar was found to penetrate better to
the plasma core in the limiter discharges, while even though the Ar levels
were larger in the diverted discharges, the HIREX signals were not very large,
indicating good screening of the Ar by the divertor.

Scorecard:

2 fizzles "Fairfax' fiducial" shot 1 and shot 16
22 plasmas
All systems performed well, though cooling was sometimes slow.

Session Leader Comments
Jun 14 1994 10:54:42:780AM940614002Francesca BombardaNice shot, HIREX settings are:
#1 -18, #2 -3.5, #3 -2., #4 2, #5 16.5
that is 1 and 5 are looking up and down at 82 cm, 2,3,4 are at the center.
Nice signal on the central channels, no lines visible at the edge

Jun 14 1994 10:56:32:170AM940614003Francesca Bombarda Again nice shot, but density still a bit high (~5e19)

Jun 14 1994 10:57:59:470AM940614004Francesca Bombarda Flooded by hard X. Density obviously too low.

Jun 14 1994 10:58:46:440AM940614005Francesca Bombarda SAme as 4

Jun 14 1994 11:00:50:220AM940614006Francesca Bombarda Good shot, now density high again. Increase amount of argon

Jun 14 1994 11:07:21:640AM940614007Francesca BombardaGood shot, something is finally visible on 1 and 5, and the signals look
symmetric! Start moving 4 outward, repeat for a couple of shots to get
enough statistics.

Jun 14 1994 11:36:43:770AM940614007Francesca BombardaFinally some signal on 1 and 5.

Jun 14 1994 11:35:27:060AM940614008Francesca BombardaSimilar to 7. #4 out to 7 cm

Jun 14 1994 01:09:48:600PM940614008Francesca BombardaSame


Jun 14 1994 01:11:15:040PM940614009Francesca BombardaSame


Jun 14 1994 01:13:47:880PM940614010Francesca BombardaSame


Jun 14 1994 01:14:24:770PM940614011Francesca BombardaSame


Jun 14 1994 01:33:55:480PM940614012Francesca BombardaFirst diverted plasma (late). Very long pulse. #1 and #5 not quite at the
same radial position.


Jun 14 1994 01:36:49:460PM940614013Francesca BombardaDisrupt at 0.95. Low density. Less argon gets into the discharge.

Jun 14 1994 02:03:41:800PM940614014Francesca BombardaDisrupt at 0.8.

Jun 14 1994 02:05:01:730PM940614015Francesca BombardaDisrupt at 0.75, too much density.

Jun 14 1994 02:29:22:040PM940614016Francesca BombardaFizzle

Jun 14 1994 02:44:47:510PM940614017Francesca BombardaDisrupt at 0.65.

Jun 14 1994 03:25:21:390PM940614018Francesca BombardaDisrupt at 0.75, but much better

Jun 14 1994 03:59:18:240PM940614019Francesca BombardaDisrupt again at 0.75.

Jun 14 1994 04:01:03:280PM940614020Francesca BombardaDisrupt again at 0.75.

Jun 14 1994 04:27:04:070PM940614021Francesca BombardaSame

Jun 14 1994 04:33:17:970PM940614022Francesca BombardaSame

Jun 14 1994 04:54:50:380PM940614023Francesca BombardaDisrupt at 0.85

Jun 14 1994 05:06:50:210PM940614024Francesca BombardaDisrupt at 1.1! Suppose we can call this a good shot!

Physics Operator Comments
Jun 14 1994 09:10:36:170AM940614001Joseph SnipesShot 1
Copied shot 940603015 as a fiducial. Fizzle!

Jun 14 1994 09:18:43:270AM940614002Joseph SnipesShot 2
Copied shot 940603019 for neutral density run. Decent shot.

Jun 14 1994 09:58:51:870AM940614003Joseph SnipesShot 3
Added third Ar puff for HIREX at 0.676 sec. for about 12 msec at 90 V.
Good shot

Jun 14 1994 09:59:45:710AM940614004Joseph SnipesShot 4
Some hard x rays. Density during current rise dropping on its own as the
machine cleans up.

Jun 14 1994 10:21:46:250AM940614005Joseph SnipesShot 5
Increased gas early to try to bring up the density. Also added a gas puff at
0.8 sec for Luke of 10 msec duration.

Jun 14 1994 10:42:52:020AM940614006Joseph SnipesShot 6
Increased gas early to try to bring up the density.
Better shot. Very few hard x rays though density is a bit high.

Jun 14 1994 11:08:41:240AM940614006Joseph SnipesShot 7
Good shot. Early current rise problems around 58 ms as the position jumps
apparently inward. May need to decrease EF4 to reduce the vertical field
early.

Jun 14 1994 11:09:01:220AM940614007Joseph SnipesShot 7
Good shot. Early current rise problems around 58 ms as the position jumps
apparently inward. May need to decrease EF4 to reduce the vertical field
early.

Jun 14 1994 11:39:18:580AM940614008Joseph SnipesShot 8
Tweaked second D gas puff time point slightly higher to try to improve the
current rise in the hope of preventing the hesitation in the current.
Decent shot. Current rise improved around 60 msec, but there is still a
glitch at 22 msec. Horne noticed that the EF2's actually start to ramp down
before t=0 (starting around -5 ms) and he thinks that might be responsible for
changes observed at breakdown.

Jun 14 1994 12:20:08:110PM940614009Joseph SnipesShot 9
Same. Good shot!

Jun 14 1994 12:20:52:760PM940614010Joseph SnipesShot 10
Same. Decent shot!

Jun 14 1994 12:44:04:200PM940614011Joseph SnipesShot 11
Same. Decent shot!

Jun 14 1994 01:00:17:510PM940614011Joseph SnipesShot 11
Moly laser blow-off injection at 0.9 sec.

Jun 14 1994 01:19:40:450PM940614012Joseph SnipesShot 12
Copied shot 940610023 to run in a diverted configuration. Not bad. Disrupted
in ramp down.

Jun 14 1994 01:26:10:640PM940614013Joseph SnipesShot 13
Increased gas late for the longer plasmas. Added more Ar puffs and increased
the duration of each puff by a couple of msec. Also increased fizzle detector
time to 1.45 sec.
Disrupted at 0.95 sec.

Jun 14 1994 01:39:16:560PM940614013Joseph SnipesShot 13
Moly laser blow-off at 0.9 sec probably led to the disruption.

Jun 14 1994 01:45:31:750PM940614014Joseph SnipesShot 14
Increased gas during flattop to flatten out the density. Also increased the
duration of the Ar puffs by a couple of msec. Decreased pre-fill to
1.1 x 10**-5 Torr. O.K. but disrupted again at 0.82 sec.

Jun 14 1994 02:00:29:700PM940614015Joseph SnipesShot 15
Increased gas during flattop to flatten out the density. Also increased the
duration of the Ar puffs by a couple of msec.
Disrupted at 0.75 sec.

Jun 14 1994 02:09:44:570PM940614015Joseph SnipesShot 15
Increased gas during flattop to flatten out the density. Also increased the
duration of the Ar puffs by a couple of msec.
Disrupted at 0.75 sec. Locked mode at 0.738 sec.

Jun 14 1994 02:18:25:640PM940614016Joseph SnipesShot 16
Increased gas early and decreased it a little during the flattop to try to
avoid a density limit disruption and avoid hard x rays early.
Fizzle!

Jun 14 1994 02:49:18:220PM940614017Joseph SnipesShot 17
Increased EF4 current at breakdown by 15 A from 1030 to 1045 A to try to push
the plasma in a little. It seemed to go out at about 20 msec on both the
H alpha and ECE polychromator data.
No, I got the sign wrong. Nonetheless, the plasma went. Disrupted at 0.65 s.

Jun 14 1994 03:27:46:080PM940614018Joseph SnipesShot 18
Decreased EF4 current at breakdown by 30 A from 1045 to 1015 A to try to push
the plasma in a little. Reduced proportional gain after 0.6 sec by about
20% on RXL. Then, moved the staircase earlier by about 50 msec so that the
maximum gain is reached at 0.6 sec. Also, changed ZCUR to be flat at -1 cm
from 0.6 sec to 1.2 sec. Disrupted at 0.76 sec. Locked mode at 0.742 sec.

Jun 14 1994 03:41:48:200PM940614019Joseph SnipesShot 19
Again density ramping up until a locked mode and disruption. It seems that
there may be too much Argon.

Jun 14 1994 04:00:18:630PM940614020Joseph SnipesShot 20
Disrupted again at 0.75 sec. No locked mode. No density ramp. Ar does not
seem to be responsible.

Jun 14 1994 04:05:21:300PM940614021Joseph SnipesShot 21
Return to D gas programming from shot 19. Increased RXL gain back to 5 after
0.6 sec. Disrupted at 0.8 sec. with a locked mode at 0.78 sec.

Jun 14 1994 04:24:48:890PM940614022Joseph SnipesShot 22
Reduced D gas a bit after 0.6 sec.
Disrupted again with a locked mode.

Jun 14 1994 04:44:06:630PM940614023Joseph SnipesShot 23
D pellet at 0.3 sec. Reduced later Ar puffs by a few msec. Locked mode at
0.82 sec, disrupted at 0.87 sec. Pellet did not make it as the gate valve
did not open.

Jun 14 1994 05:23:28:900PM940614024Joseph SnipesShot 24
Reduced the Ar puffs slightly after 0.4 sec. Plasma lasted longer until
about 1.1 sec. Either late Ar puff or Moly injection at 1.0 sec may have
led to the disruption. Locked mode at 1.04 sec.

Engineering Operator Comments
ShotTimeTypeStatusComment
108:54:20:110AMPlasmaOkNo faults.
209:10:28:850AMPlasmaOkNo Faults
309:24:41:970AMPlasmaOkNo faults.
409:46:56:260AMPlasmaOkno faults
510:11:25:040AMPlasmaOkNo faults.
610:31:22:130AMPlasmaOkNo faults
710:58:43:150AMPlasmaOkNo faults.
811:23:18:510AMPlasmaOkNo Faults.
911:53:23:640AMPlasmaOkno faults
1012:18:18:260PMPlasmaOkno faults
1112:39:59:010PMPlasmaOkno faults
1201:02:58:620PMPlasmaOkno faults
1301:23:10:200PMPlasmaOk600 kA disruption
1401:43:35:220PMPlasmaOkAnother 600 kA disruption; induced EF1L commutation fault
1501:58:27:660PMPlasmaOkAnother 600 kA hit
1602:13:27:860PMPlasmaOkFizzle!
1702:29:03:330PMPlasmaOkanother 600 ka hit; TF supply crowbar after plasma ended.
1803:04:19:890PMPlasmaOk600 kA disruption induced EF1L commutation failure
1903:28:19:290PMPlasmaOkanother 600 kA disruption; EF1L commutation failure
2003:45:22:320PMPlasmaOkdisruption induced comm fails
2104:02:26:280PMPlasmaOk600 kA disruption; no faults
2204:21:29:570PMPlasmaOkanother 600 kA hit; 3 power supplies knocked off-line
2304:39:37:010PMPlasmaOkyet another 600 kA disruption; fizzle detector has not been working sinc
2405:02:19:700PMPlasmaOklonger but still a 600 kA disruption