Alcator C-Mod Run 950110 Information

Back to runs

Miniproposals
Miniproposal:062
Date Filed: 6/16/1994
Title:PCX Beast commissioning
First Author:Rejean Boivin
Session Leader:Rejean Boivin (shots 1-32)

Operators
Session leader(s):Rejean Boivin
Physics operator(s):Steve Wolfe
Engineering operator(s):Joe Daigle,Vinny Bertolino

Engineering Operator Run Comment
NPA

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:11:773PM
Author: To Be Determined
We will be calibrating the Big beast and the small beast if it's
behaving. We will start with reproducible shots (I made my sacrifice
to the Alcator Gods this morning), approximately 10-12 if everything
goes well. Afterwards we will attemptto "calibrate" the hydrogen
row (H to D ratio) by puffing/injecting various amounts of hydrogen
into the machine.

950110001
Usual OH/Chopper Tuesday morning test. Found small leak in E port
(Argon), port now pumped.

002 First attempt, Dud

003 First plasma, needs little tweaking to avoid disruption on the way down.

004 Good one, almost identical, still disrupted on the way down

005 Another good one, very much the same, disruption much later.

006 Fizzle, almost made it. Conditions changed?

007 Good, density about the same as previous ones.

008 Good, a tiny change in density towards the end.

009 Good, density pretty close. First signs of signal in Beast Junior
(TCX, K port)

010 Good, still holding density. Beast Junior gets good signal. Some
Preamps to be fixed before comparing temperature.

011 Still holding, good. Moved to calibrate second row in analyzer.

012 Density still the same. A few more....

013 Good stuff, the streak is continuing.

014 Good, density holding.

015 Plasma, pretty similar, although many small changes, and "big"
injection early.

016 Good plasma, density the same as before. Some injections again,
origin ???

017 Good, density very flat. Last point of reproducible sequence.

018 Good, nominal density the same, Hyd. puff at 0.7 sec. Observed
a 25% increase in NL, very visible in the NPA signal.

019 Good, nominal density the same, Hyd. puff at 0.6 sec. Smaller
increase in NL, visible in the NPA signal. Small Li pellet
injected at 1.1 sec.

020 Good, still same nominal density, Medium H puff.

021 Good, Smaller Hydrogen puff, just visible in the NPA.
Medium Li pellet at 1.1 sec.

022 Good, Larger Hydrogen puff, up to 60 msec long, feedback catching
on with puff.

023 Good, replaced puff with ~20% H in prefill. Line still full with
D so no appreciable H in plasma.

024 Same than 023, no visible change.

025 Purged line for prefill, in plenum approximately 22% of H.
Got fizzle. Changed prefill pressure a little bit.

026 Purged line for better/updated H ratio of approx 22%. Probably
the amount of H in the machine will be lower. Saw some H tail
ions in the end of the shot.

027 Repeat 026, nice plasma. Tail ions also.

028 Dud, field config. wrong?

029 Good plasma, Lower prefill concentration of H, ~13% probably lower
in machine.

030 Good plasma. Lower density to 5e19 Nl. No Hards observed, radiated
power reasonable.

031 Good plasma, lower density to 4e19 Nl. No hards, funny end.

032 Good, density to 7e19, A good sequence. And a good day.


Overall, the goals have been achieved, we should be able to cross-calibrate
the internal channels of the Beast in F port. We also got precious info
about the Hydrigen measurements and we were able to get some basic
data from the other analyzer (Beast Junior in Kport).

Physics Operator Summaries
Entered: Jul 7 2004 04:36:52:833PM
Author: To Be Determined
Physics Operator Summary for 11/10/95

MP 62A Calibration of CX diagnostics
Session Leader: Boivin
Physics Operator: Wolfe
Eng. Operators: Bertolino/Daigle

The goal of the run was to get reproducible diverted discharges at low density
for calibration of the PCX and TCX diagnostic systems. Shots with D2 only, H2
secondary puff, and mixed puff and fill were required to calibrate the mass
differentiation. Piggyback experiments included Li pellet injection to check
out the cigar detector, a vertical scan of the ECE beam,and RF conditioning of
the E-port RF antenna. All of these were accomplished.

From the operational standpoint this was a pretty routine run. Segment 2 from
941221005 was loaded, and the P gain on the fast ZCUR dropped by a factor of 2
to account for the reduced series resistor on the chopper. Startup was the
same as we ended up with on 950106. Some tuning was done on the rampdown,
basically extending the ramps on everything. Shots 3 and 4 disrupted early in
rampdown, with high radiation levels but no obvious injections. This was cured
by slowing the Ip ramp down and holding the density up until .95 sec and then
ramping the NL04 down more slowly. Some very late vertical instabilities
(around 1.45 sec) were more or less fixed by not pushing RCUR in so hard at
the end.

Shot 1 was the first-day-of-the-week OH test; the chopper was run as well.

Shot 2 was the first plasma try. It failed due to the EF1 problem noted below.

Shot3-17 were constant shots with NL04 programmed to 6e19, except for tweaks
to the ramp-down (see logbook under PHYSICS_OPERATOR for details)

Shots 18-22 had H2 puffs (B-side-upper) at different levels. In addition,
there were Li pellets on shots 19 and 21.

Shots 23-24 used a mixed puff 20% H2 in A-side, but without having purged the
line. There was no sign of H above background on these, so the line was
probably still all D2.

Shots 25-27 were 22% H2 in the A-side plenum after purging the line; 25
fizzled at a 1.8e-5 fill and the gas was lowered to 1.5e-5, which worked.

Shots 28-32 were 13% H2 in the plenum, after re-purging. Shot 28 was a dud (!)
at a fill of 1.5e-5, the others were back up to 1.7e-5 fill and ran. However,
the null looked bad on 28, so it may not really have been the gas. Shots 29-32
were a small density scan:
Shot NL_04
---- -----
29 6e19
30 5e19
31 4e19
32 7e19

Problems:
--------
The fix on the EF1 supplies that was installed on Monday (a lower voltage
Zener across the cap in the voltage feedback circuit) did not work; it
resulted in clamping the voltage at 100V, which was insufficient to get to
more than half the demand current (shot 2). This was removed at shot 3, and we
got good startups as on Friday. On shot 8, a new 4.7V Zener was installed, and
this also worked, although the supply is still not behaving properly.

A minor PCS bug(feature) was uncovered. The loaded waveform for CLEARIN was
invalid, because it called for too large a (negative) value during rampdown.
However, this was not flagged until a change was made on the EDIT_WIRE screen.
The waveform was then re-drawn to be within bounds on shot 15. Since the
WAVEGEN outputs its maximum value under these circumstances, no harm was done
by not recognizing the invalid waveform, but it probably should have been
flagged at BUILD_ALL anyway.

Scorecard:
---------
Tests 1
Duds 2 (1 due to Power systems)
fizzles 2
plasma 27 (2 disrupted on rampdown)
--
shots 32


Session Leader Comments
Jan 10 1995 08:19:21:710AMRejean BoivinWe will be calibrating the Big beast and the small beast if it's
behaving. We will start with reproducible shots (I made my sacrifice
to the Alcator Gods this morning), approximately 10-12 if everything
goes well. Afterwards we will attemptto "calibrate" the hydrogen
row (H to D ratio) by puffing/injecting various amounts of hydrogen
into the machine.

Jan 10 1995 08:52:53:840AM950110001Rejean BoivinUsual OH/Chopper Tuesday morning test. Found small leak in E port
(Argon), port now pumped.

Jan 10 1995 09:10:09:720AM950110002Rejean BoivinFirst plasma attempt, Dud

Jan 10 1995 09:43:40:590AM950110003Rejean BoivinGood shot, disrupted on the way down, Try to reproduce now.

Jan 10 1995 09:59:40:370AM950110004Rejean BoivinGood shot, disrupted on the way down, A good duplicate. Try still
to get rid on the disrupted tail

Jan 10 1995 10:07:21:610AM950110005Rejean BoivinGood shot, Very close to the previous 2, take it while you can...
A very small disruption at the very end. Keep going...

Jan 10 1995 10:19:11:030AM950110006Rejean BoivinFizzle, hopefully conditions will not change too much for the next
plasma.

Jan 10 1995 10:31:03:650AM950110007Rejean BoivinPlasma, density very close to the previous ones.

Jan 10 1995 10:53:44:090AM950110008Rejean BoivinPlasma, density very close to the previous ones. A tiny change towards
the end.

Jan 10 1995 11:09:10:980AM950110009Rejean BoivinPlasma, again density very close to the previous ones. First signs
of signal in Beast Junior (TCX, K port).

Jan 10 1995 11:44:01:430AM950110010Rejean BoivinPlasma, again density very close to the previous ones.

Jan 10 1995 11:44:35:630AM950110011Rejean BoivinPlasma, again density very close to the previous ones. Maybe a little
lower.

Jan 10 1995 11:51:14:180AM950110011Rejean BoivinPlasma, again density very close to the previous ones. Maybe a little
lower. Trying to cross-calibrate second row of analyzer.

Jan 10 1995 12:04:28:980PM950110012Rejean BoivinPlasma, density holding. Still calibrating other row. Just need
a few more...

Jan 10 1995 12:20:38:110PM950110013Rejean BoivinPlasma, density holding. Cross your fingers.

Jan 10 1995 12:34:22:100PM950110014Rejean BoivinPlasma, density holding. Cross your fingers. We will be moving to
H puffing shortly.

Jan 10 1995 12:53:47:660PM950110015Rejean BoivinPlasma, Many small changes, "big" injection early.

Jan 10 1995 01:18:01:600PM950110016Rejean BoivinPlasma, Good density, still some injections, origin???

Jan 10 1995 01:32:54:010PM950110017Rejean BoivinPlasma, density pretty flat during flat top. Last point for
reproducible sequence.

Jan 10 1995 01:52:36:560PM950110018Rejean BoivinGood shot

Plasma, Nominal density still the same. Hydrogen puff at 0.7 sec
for 30 msec (100 V). 25% increase in NL. Visible on the NPA in the
hydrogen row.

Jan 10 1995 02:04:15:480PM950110019Rejean BoivinGood shot

Plasma, Nominal density still the same. Hydrogen puff at 0.6 sec
for 15 msec (100 V). Smaller increase in NL. Visible on the NPA in the
hydrogen row. Small Li pellet injected at 1.1 sec.

Jan 10 1995 02:22:13:110PM950110021Rejean BoivinGood shot

Plasma, Same nominal density. Hydrogen puff at 0.6 sec.
Smaller increase in NL.

Jan 10 1995 02:33:33:370PM950110021Rejean BoivinGood shot

Plasma, Same nominal density. Hydrogen puff at 0.6 sec.
Very small injection (9 msec).
Medium pellet injection at 1.1 sec.

Jan 10 1995 03:33:20:230PM950110022Rejean BoivinGood shot

Plasma, Same nominal density. Removed H puff to be replaced
by Hydrogen in prefill. Attempted with approx. 20% of H.
Virtually no H in the discharge due to D only in line.

Jan 10 1995 03:38:23:440PM950110022Rejean BoivinGood shot

Plasma, Larger H puff, approximately 60 msec, feedback still on so
puff not so much larger in amplitude.

P.s. Ignore other entry about change in prefill. (for shot 23)

Jan 10 1995 03:36:46:230PM950110023Rejean BoivinGood shot

Plasma, Same nominal density. Removed H puff to be replaced
by Hydrogen in prefill. Attempted with approx. 20% of H.
Virtually no H in the discharge due to D only in line.

Jan 10 1995 03:34:49:990PM950110024Rejean BoivinGood shot

Plasma, Same nominal density.
Hydrogen in prefill. Attempted with approx. 20% of H.
Virtually no H in the discharge due to D only in line,
still not completely coming through.
Purge the plenum/lines for next shot..

Jan 10 1995 03:41:55:270PM950110025Rejean BoivinFizzle

Puged line for better/updated H ratio of approx 22%. Try again
next shot.

Jan 10 1995 03:56:20:430PM950110026Rejean BoivinGood plasma

Purged line for better/updated H ratio of approx 22%. Probably
the amount of H in the machine will be lower. Saw some H tail
ions in the end of the shot.

Jan 10 1995 04:22:42:120PM950110027Rejean BoivinGood

Repeat of 026, Tail ions also present.

Jan 10 1995 04:21:19:430PM950110028Rejean BoivinDuddy duddy Dud

See Steve W.'s entry for more Duddy details.

Jan 10 1995 04:37:52:660PM950110029Rejean BoivinGood

Lower concentration of H (prefill with ~13%), probably lower in machine.

Jan 10 1995 04:44:23:110PM950110030Rejean BoivinGood

Lower density to 5e19 NL. Good plasma, no Hards "visible",reasonable
radiated power.

Jan 10 1995 05:06:17:130PM950110031Rejean BoivinGood

Lower density to 4e19 NL. Good plasma, no Hards "visible",reasonable
radiated power.

Jan 10 1995 05:07:56:710PM950110032Rejean BoivinGood

Raise density to 7e19 NL. Good plasma, no Hards "visible",reasonable
radiated power. Good day Folks!!! Thanks to our Engineers, it's been
a very productive day.

Physics Operator Comments
Jan 10 1995 08:11:50:990AMSteve WolfeRun 950110
MP# 62A PCX Commissioning
SL: Boivin
PO: Wolfe

Plan: Start from a modified 941221005 (see below)
First establish a good discharge
Repeat 10-12 times as identical as possible

Second puff H in, increasingly more (5-7 shots)

Third, if time allows a little scan in density (D only)

Start from last shot and IMPORT SEG #2 from 941221005
Cut P gain on ZCUR 3 from 9 to 4 to compensate fro lowered resistor on
Chopper circuit.

Pre-op problems:

Couldn't get ECDC on because of an unclearable gas fill fault.
Finally tracked down that TORVAC was seeing the STATE as ABORT
instead of TEST. After some cycling of STATE machine, TORVAC finally
picked up the right STATE (Network Error).

Discharge cleaning start at 07:30

Second problem: Ion gauge on TMP2 was dead? It seems to have fixed
itself now.

There has been a mod to the EF1 supplies: A 4V Zener across the
feedback cap in the error integrator replacing an 8V Zener.

Looking at Vinnie's error scope on shot 950106005 we see traces that
still don't make complete ssense - large negative error implying supply
giving more voltage than requested. Have to keep an eye on this.

Jan 10 1995 08:20:49:100AMSteve WolfeRun 950110
MP# 62A PCX Commissioning
SL: Boivin
PO: Wolfe

Plan: Start from a modified 941221005 (see below)
First establish a good discharge
Repeat 10-12 times as identical as possible

Second puff H in, increasingly more (5-7 shots)

Third, if time allows a little scan in density (D only)

Start from last shot and IMPORT SEG #2 from 941221005
Cut P gain on ZCUR 3 from 9 to 4 to compensate fro lowered resistor on
Chopper circuit.

Pre-op problems:

Couldn't get ECDC on because of an unclearable gas fill fault.
Finally tracked down that TORVAC was seeing the STATE as ABORT
instead of TEST. After some cycling of STATE machine, TORVAC finally
picked up the right STATE (Network Error).

Discharge cleaning start at 07:30

Second problem: Ion gauge on TMP2 was dead? It seems to have fixed
itself now.

There has been a mod to the EF1 supplies: A 4V Zener across the
feedback cap in the error integrator replacing an 8V Zener.

Looking at Vinnie's error scope on shot 950106005 we see traces that
still don't make complete ssense - large negative error implying supply
giving more voltage than requested. Have to keep an eye on this.

Jan 10 1995 08:21:58:000AMSteve Wolfe Run 950110
MP# 62A PCX Commissioning
SL: Boivin
PO: Wolfe

Plan: Start from a modified 941221005 (see below)
First establish a good discharge
Repeat 10-12 times as identical as possible

Second puff H in, increasingly more (5-7 shots)

Third, if time allows a little scan in density (D only)

Start from last shot and IMPORT SEG #2 from 941221005
Cut P gain on ZCUR 3 from 9 to 4 to compensate fro lowered resistor on
Chopper circuit.

Jan 10 1995 08:22:29:950AMSteve Wolfe Run 950110
MP# 62A PCX Commissioning
SL: Boivin
PO: Wolfe

Pre-op problems:

Couldn't get ECDC on because of an unclearable gas fill fault.
Finally tracked down that TORVAC was seeing the STATE as ABORT
instead of TEST. After some cycling of STATE machine, TORVAC finally
picked up the right STATE (Network Error).

Discharge cleaning start at 07:30

Second problem: Ion gauge on TMP2 was dead? It seems to have fixed
itself now.

There has been a mod to the EF1 supplies: A 4V Zener across the
feedback cap in the error integrator replacing an 8V Zener.

Looking at Vinnie's error scope on shot 950106005 we see traces that
still don't make complete ssense - large negative error implying supply
giving more voltage than requested. Have to keep an eye on this.

Jan 10 1995 08:41:29:340AM950110001Steve WolfeShot#950110001:

OH test and chopper test.

Looks ok.

Jan 10 1995 09:16:28:800AM950110002Steve WolfeShot#950110002:

Try for plasma. Startup from last shot Friday (I hope);
Seg 2 from 941221005 with P gain on ZCUR 3 reduced by about a factor 2.
Enable Ar puff (3psi in plenum)
Fill = 1.5e-5

Note: The Ar leak showed up again. Childs went down to the cell to
pump out the E-port seal.

Dud EF1's never get close to demand. They look weird.
It looks like the Zeners are too low.
For next shot Vinnie will go back to the old configuration

Jan 10 1995 09:33:52:940AM950110003Steve WolfeShot#950110003:

EF1s unfixed. The new Zeners had been clip-leaded in, so they were easy
to remove.
No other changes.

Shot went - disruption on ramp-down.
Some oscillation on EF1s - they had left the gain turned up; will
adjust down next shot.

Jan 10 1995 09:49:55:950AM950110004Steve WolfeShot#950110004:

Repeat.
Looks the same - same disruption.
It looks like a radiation problem, but density isn't high.

Jan 10 1995 10:07:57:540AM950110005Steve WolfeShot#950110005:

Slow Ip rampdown down (to zero at 1.6)
Hold density flat till 0.95, program to go negative around 1.1

Better, made it to 1.5 sec ; small injection at 1.15 sec

Jan 10 1995 10:18:16:760AM950110006Steve WolfeShot#950110006:

Keep density feedback on until 1.7 sec (was turning off at 1.4)
Fizzle. Bounced on the outside.

Jan 10 1995 10:35:02:280AM950110007Steve WolfeShot#950110007:

Raise the fill to 1.8e-5

Disrupted at 1.47 sec on rampdown. Vertical instability

Jan 10 1995 10:51:27:390AM950110008Steve WolfeShot#950110008:

Extend gas puff on pulse gas 3
Vinnie has put a new different zener into the EF1's.
Program RCUR further in at crossover.

Ran through. Density a little flatter late.
It's off the antenna now at crossover. (Yuichi had complained)

Jan 10 1995 10:51:32:670AM950110008Steve WolfeShot#950110008:

Extend gas puff on pulse gas 3
Vinnie has put a new different zener into the EF1's.
Program RCUR further in at crossover.

Ran through. Density a little flatter late.
It's off the antenna now at crossover. (Yuichi had complained)

Jan 10 1995 11:00:41:930AM950110009Steve WolfeShot#950110009:

Repeat.
Similar. Still getting a vertical disruption at low current late in
rampdown. n/ncrit is going up because
1) li is rising
2) Elongation is going back up .

Joe and Vinnie want to swap master control boards in the EF1 supplies
for next shot.

Jan 10 1995 11:36:24:040AM950110010Steve WolfeShot#950110010:

Joe and Vinnie did not swap master control boards in the EF1 supplies
for this shot. (There was a problem when they tried).

Extend EF4 current later (was 1.45 now 1.59sec)
Still has a little vertical problem at the end. It goes up.

Jan 10 1995 11:45:49:320AM950110011Steve WolfeShot#950110011:

No change.

Still has the vertical problem at the end.

Jan 10 1995 12:02:56:220PM950110012Steve WolfeShot#950110012:

Slow down and extend the ramp in on RCUR (end at 1.64s at 0.62m)

Lasted all the way through (to 1.52sec)
Still a bit too much elongation at the end.

Jan 10 1995 12:07:15:600PM950110013Steve WolfeShot#950110013:

Repeat. Very similar.


For next shot (14) move final RCUR position to .63 (was .62)

Jan 10 1995 12:26:42:070PM950110014Steve WolfeShot#950110014:

move final RCUR position to .63 (was .62)

That made it all the way to the fizzle dietector.
In trying to extend CLEARIN gain I find that it is drawn beyond the
WAVEGEN limits (doesn't check until I update in EDIT_WIRE.

For next shot, redraw final values to fit Wavegen, extend past 1.7sec.

Jan 10 1995 12:53:59:050PM950110015Steve WolfeShot#950110015:

Redraw final values on CLEARIN to fit Wavegen, extend past 1.7sec.

Looks the same.
There is a report of a water leak in an excitation supply at
the alternator. There will be a short delay.
Actually the density is a little lower, and the EF2L rails
around .38sec.

Jan 10 1995 01:14:22:130PM950110016Steve WolfeShot#950110016:

No change, see if it goes back.
Density is back up, some small injections but not at the .35-.4 sec
time.
Disrupts at 1.52 sec (140kA) this time.

Jan 10 1995 01:22:46:780PM950110017Steve WolfeShot#950110017:

No change - ran through ok.

Jan 10 1995 01:43:10:180PM950110018Steve WolfeShot#950110018:

Start puffing H2 through B-side upper (P.G.#2)
Put a 30msec wide 100V pulse at 0.7seconds

Got about a 25% increase in density starting around .71sec.
Halpha more than doubles.

Jan 10 1995 02:00:18:480PM950110019Steve WolfeShot#950110019:

Put a 15msec wide 100V pulse at 0.6 seconds
The LPI will pulse at 1.1sec (during rampdown)

Got the pellet, no problem.
H2 puff is much smaller effect on desity. <10%.

Jan 10 1995 02:12:18:850PM950110020Steve WolfeShot#950110020:

Put a 23 msec wide 100V pulse at 0.6 seconds
No Li pellet.

Looks ok.

Jan 10 1995 02:24:56:020PM950110021Steve WolfeShot#950110021:

Put a 9 msec wide 100V pulse at 0.6 seconds
Medium size Li pellet at 1.1sec.

Pellet went ok. Had an injection at 1.0+, then the pellet at 1.1sec
Very small density increase at H2 time.

Jan 10 1995 02:45:40:620PM950110022Steve WolfeShot#950110022:

Increase H2 puff to 60msec wide starting at 0.6sec
No more Li pellets.

About 30% increase in density.

Jan 10 1995 02:57:41:130PM950110023Steve WolfeShot#950110023:

Disable B-side upper puff
Mix A-side plenum to 20% H2, 80%D2

Runs fine. No obvious H signal on TCX; line is probably still full of D2

Jan 10 1995 03:11:33:810PM950110024Steve WolfeShot#950110024:

No change, see if the line gets exchanged.

No sign of H2.

Jan 10 1995 03:37:09:790PM950110025Steve WolfeShot#950110025:

Purge the line and refill with the 80:20 mix.
Now at 77.5:22.5

Fizzle. No ECE signal, but it does have a bounce on H-alpha.

Jan 10 1995 03:48:53:170PM950110026Steve WolfeShot#950110026:

Drop the fill to 1.5e-5.

That worked. Good signals on CX. RF got .25 MW; Rejean sees an H tail.

Jan 10 1995 04:14:35:190PM950110027Steve WolfeShot#950110027:

Repeat.

Similar.

Jan 10 1995 04:26:29:410PM950110028Steve WolfeShot#950110028:

Change mix on A-side to 87:13
Leave fill at 1.5e-5

Dud! Null looks bad, too much vertical field?

Jan 10 1995 04:35:17:650PM950110029Steve WolfeShot#950110029:

Raise fill to 1.7e-5 and try again.

Got it back. I don't really believe the gas did it.
Null still looks pretty bad.
RF gets to .5 MW

Jan 10 1995 04:43:04:770PM950110030Steve WolfeShot#95011030:

Change density programming to NL4=5e19

It ran ok, got 5e19.
No hards, bolo is ok.

Jan 10 1995 04:55:11:710PM950110031Steve WolfeShot#95011031:

Change density programming to NL4=4e19

Looks good, got 4e19.

Jan 10 1995 05:07:55:730PM950110032Steve WolfeShot#95011032:

Change density programming to NL4=7e19

Several injections, got NL5=7e19 ok.

Engineering Operator Comments
ShotTimeTypeStatusComment
108:38:04:790AMTestOkcoax test
209:06:12:720AMPlasmaBadef1's are clamped at too low a voltage
309:25:24:910AMPlasmaOkef1 gain lowered for next shot
409:43:38:160AMPlasmaOkno faults
509:57:27:650AMPlasmaOkno faults
610:12:39:170AMPlasmaOkno faults
710:25:49:880AMPlasmaOkno faults
810:40:44:080AMPlasmaOkno faults
910:53:56:390AMPlasmaOkoh2u comm fault late in the shot
1011:27:34:360AMPlasmaOkno faults
1111:37:53:270AMPlasmaOkno faults
1211:50:43:970AMPlasmaOkcomm faults oh2u, ef1l after disruption
1312:04:35:440PMPlasmaOkno faults
1412:17:48:170PMPlasmaOkno faults
1512:39:44:810PMPlasmaOk
1601:03:12:960PMPlasmaOkNo Faults.
1701:17:19:500PMPlasmaOkNo faults.
1801:34:52:010PMPlasmaOkNo faults.
1901:50:56:720PMPlasmaOkNo faults.
2002:04:54:750PMPlasmaOkNo Faults.
2102:18:00:390PMPlasmaOkNo faults.
2202:33:21:830PMPlasmaOkno faults
2302:48:46:820PMPlasmaOkNo Faults.
2403:01:35:500PMPlasmaOkNo Faults.
2503:30:04:720PMPlasmaOkNo Faults.
2603:41:07:530PMPlasmaOkNo Faults.
2703:52:24:030PMPlasmaOkNo Faults.
2804:17:01:880PMPlasmaOkNo Faults.
2904:26:45:110PMPlasmaOkNo Faults.
3004:38:18:600PMPlasmaOkNo faults.
3104:49:55:140PMPlasmaOkNo Faults.
3205:01:51:690PMPlasmaOkNo Faults.