Alcator C-Mod Run 950509 Information

Back to runs

Miniproposals
Miniproposal:105
Date Filed: 3/24/1995
Title:Dependence of Detachment Threshold and Radial Extent on Plasma Current & q
First Author:Bruce Lipschultz
Session Leader:Bruce Lipschultz (shots 1-29)

Operators
Session leader(s):Bruce Lipschultz
Physics operator(s):Steve Wolfe
Engineering operator(s):Joe Daigle,Vinny Bertolino

Engineering Operator Run Comment
Wolfe

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:13:680PM
Author: To Be Determined
Run 950509

Engineering operator: V. Bertolino
Physics operator: S. Wolfe
Session leader: BLip

M.P.# 105: Effect of current and q on divertor characteristics

This m. p. has 2 parts: First we plan to study the detachment characterisitics
of plasmas at 1 MA . For the second half of the mp we will be varying q.

Today we addressed the first part of this mp. We ran 1 MA shots first with
vertical plate and then with flat-plate equilibria. The first 1/2 of the
run was spent trying to implement a new inner strike point controller -
STRKIN. This was successful (after alot of shots) in the sense that the
controller did what it was supposed to. However, this control was
incompatible with the location of the x-point; the plasma dropped down to
'sit' on the divertor plates.

We gave up on STRKIN control and switched back to a combination of STRKPSI and
RXL. This eventually worked and we went back up to 1 MA (shot 15) and
proceeded with a density scan with the vertical plate equilibria. Starting
at nl04=1.45e20 (shot 19) we saw detachment start. As the density was
increased over the next several shots the detachment appeared to extend further
up the divertor plate. The verification will have to await the analysis
with of the FSP data. At nl04=1.85e20 we did appear to be detached up through
probe 7. The highest density reached with vertical plate was 2.1e20. For that
shot (22) it is possible that even probe 8 was detached. In summary the
threshold for death ray appearance is higher than at 800 kA (1.45e20 vs
1.1-1.2e20 for 800kA). The process of detachment also seems different at 1 MA
in that the pressure drop edge moved up the divertor face over a range in
density ( 1MA) as opposed to the whole vertical face of the divertor
immediately after the death ray disappears.

We then dropped back to 800 kA for shot 23 with flat-plate divertor equilibria.
Shots 24-27 were flat-plate at 1 MA. We achieved densities of 1.0, 1.4 and
1.8 (which disrupted and ended the run). We did not observe any detachment on
these shots. Unfortunately the separatrix sweep at nl04=1.8e20 was interrupted
by the disruption and so we do not know whether detachment was occurring.

A summary of shots follows:

shot 1: power supply test

shot 2: 800 kA, nl04 = 8.5e19. Right gap and SSEP a little small.

shot 3: nl04=8e19. SSEP better (1.5 or so). Strike point down aroung
probe 4 and drifting.

shot 4: nl04= 8e19. Strike point on probe 3. 800 kA.

shot 5: no change other than strike point on probe 2 now. Unfortunately,
x-point riding on inner nose.

shot 6: same but better x-point control. Next shot to 1 MA.

shot 7: try for 1 MA failed, disruption at .37 seconds.

shot 8: nl04= .8e20, 1MA. Still having problems with x-point position.

shot 9: nl04=0.7e20, 1 MA. Disruption at 1.1 sec

shot 10: disruption

shot 11: disruption

shot 12: 800 kA again to regroup and try again, lots of injections.

shot 13: same, still tuning

shot 14: still tuning

shot 15: 1 MA, 7e19 on nl04.

shot 16: Disruption at 1.1 seconds. nl04 = .7e20, FSP scan ok.

shot 17: nl04=1.15e20. FSP scan to within 2 mm of separatrix.

shot 18: nl04=1.25e20, FSP scan ok. Not detached.

shot 19: nl04=1.45e20 (rises to 1.55 after .9 seconds). There does
appear to be detachment at probes 4 & 5 of the outer divertor that
shot along with a death ray on probe 4.

shot 20: nl04 = 1.55-1.7 e20. FSP scan ok. Detachment again on probes
4 & 5 but no further up the plate!

shot 21: nl04 = 1.85 e20. FSP scan ok. Detachment again on probes
4 -6 + possibly probe 7 (but we don't have a domed probe there).

shot 22: nl04= 2.1e20. FSP scan ok. detached up through, I think,
probes 7 & 8. The decision about probe 8 will have to await the FSP
analysis.

shot 23: 800 kA Flat-plate divertor loaded in from last week (950503018).
nl04=1.0e20.

shot 24: 1 MA, nl04=1.e20, no FSP scan.

shot 25: 1 MA flat-plate. nl04=1.0e20. FSP scan.

shot 26: nl04=1.4e20, FSP scan ok, no evidence of detachment.

shot 27: STRIKE OUT! flat-plate out. We had a BIG disruption.

shot 28: He3 pulse for Yuichi, 800 kA, nl04=0.7e20.



Physics Operator Summaries
Entered: Jul 7 2004 04:36:54:160PM
Author: To Be Determined
Physics Operator Summary for 950509
MP#105 Divertor Detachment (1MA)
SL: BLIP
PO: Wolfe
EO: Bertolino/Daigle

The goal of this run was to get ohmic detachment data at 1MA for vertical
plate and "flat plate" configurations. I didn't expect to get through the
whole program, and as it happened we didn't. This was partly because I wasted
too much time at the beginning of the run trying to get a non-overdetermined
control using STRKPSI and STRKIN. This actually worked, but for the
strikepoint at probe 2, this control ended up with the x-point very low. We
eventually went back to a STRKPSI,RXL,ZXL control scheme, which worked well
enough.

To my surprise, we actually got to the flatplate part of the run. For
this we used the same basic scheme as Ian had last Wednesday; this worked fine
until we pushed the density to high (NL_04=1.8e20) and got a Halo **OUT** on
shot 27 (270kA halo current). The probable cause was OH2L voltage railing at
65Volts. These plasmas may just not be possible with the present supplies. It
would probably be worthwhile to see if there is any room left to adjust the
margin angles on the OH2 supplies.

In view of the short time remaining, there was no way to back off and try
another approach, even if I could have thought of one. Therefore, I reloaded
an earlier low-density 800kA shot and let Yuichi try out the He3 puff for
tomorrow on the last 2 shots.

The detailed plan for today was:

(-1) Engineering setup as for 950505012, except delay TF start to -1.0 sec.
A-side plenum filled to 20psi of D2. ECDC in D2.

(0) Start with Segment 1 from Friday, and Segment 2 a clone of 950502019, an
800kA shot with the desired characteristics: strike point in probe 2-3 area,
SSEP > 1.6cm, inner and outer gaps > 1.8cm. Initial changes to 950502019:
NL_04 changed from 1.5e20 to .7e20, delay RXL ramp from .95sec to 1.05sec.

Try to get a robust looking shot with NL_04=0.7e20, and the above gaps and
strikes, preferably with ZCUR between 0 and -1cm, but don't push too hard on
that.

Things to try: Increase IC_EF4 program to 2500A; Adjust RXL,ZXL gains to
reduce over-determination of controllers; eliminate RXL,ZXL control entirely
and use STRKIN; keep an eye on EF2's and perhaps adjust CLEARIN ramp to keep
them off the rail early; watch for voltage saturations and current railings;
tweak up the ramp-down to try to eliminate disruptions without RF.

(1) When satisfied with the 800kA shot, go up to 1 MA . Check the EF2's and
EF3 ramp. Consider delaying the crowbar times to get more current early.

(2) After the shot is set up and Brian has a FSP scan at nl04=0.7 we will
raise the density in steps of 0.2 until death ray has come and gone (6 - 10
shots depending if Brian needs extra shots). Then go back and fill in
density scan through death ray range in density (2 more shots).

(3) Starting where we left off density scan increase density in 0.4 steps
to maximum. Use either NINJA or B-side LOWER valve to get to high density, if
needed; note - WE WILL NOT BE USING ARGON in this run.
(2 -3 shots).

(4) Convert to flat plate scan of last Wednesday but at 1 MA. Start at
nl04=0.7 (5 shots?). It may make sense to lengthen the shot to achieve
the return scan across probe 8 properly.

(5) Step up density in 0.4 steps to maximum (5-8 shots depending on FSP
needs).

(6) Fill in density in steps of 0.2 around detachment start ( if any).

What actually happened was:
---------------------------
Shot 1 was the usual Tuesday morning test

Shot 2-6 were spent tuning up the STRKIN/STRKPSI control at 800kA

Shot 7-10 were at 1.0MA with STRKIN/STRKPSI. It didn't work very well, with
several disruptions in early rampdown and moving targets for the FSP. The main
problem was that the x-point was forced very low, close to the floor, late in
the shot.

Shot 11 went back to RXL/STRKPSI control at 1MA; this disrupted in flattop
with a bad VDE and EF2's and EF4 all on their rails. Fortunately the
disruption went up, and halo current was small.

Shot 12-14 were back at 800kA, tuning up RXL/ZXL/STRPSI control. I ended up
with RXL on wire 9 with P=36/sec, I=50/sec^2; STRKPSI on wire 12 with the
controller calculated orthogonal to STRKIN (full rank) and P=85/s,I=142/s^2;
ZXL on wire 6 with P=10/s.This combination allowed the RXL to fight the
STRKSPI, so typically we had good RXL position amd STRKPSI near probe 4,
rather than probe 2. We probably could have used STRKIN/STRKPSI if we had been
willing to program STRPSI for probe 4 in the first place, but BLIP's standards
became looser as the day wore on (and on and on and ...)

Shot 15-22 were a density scan at 1MA. Full detachment was obtained at
NL_04=2.1e20 on shot 22. B-side LOWER valve was used for additional D2 puff,
since B-side Upper has He3 in it. On shot 20, Joe moved the margin angle on
the EF1 supplies from 20 to 18, to try to get more voltage, as #19 had both
EF1's in saturation; this seemed to help. There may be more safe room on this
adjustment.

Shot 23 went back to 800kA to set up the flatplate shots. Loaded seg 2 from
950503018 and raised ZCUR by 1cm. This ran well.

Shot 24-27 were a flatplate density scan at 1MA. 24-26 ran well, although
voltage was rising as we increased density, as expected. On 25 the reverse
sweep was increased so the separatrix went back across probe 8 at the end of
the sshot. Shot 27 disrupted hard around .84sec, giving a halo current **OUT**
at 270kA. This terminated the flatplate run.

Shot 28-29 reloaded shot 13, with the ZCUR ramp slowed down to help rampdown.
Enable He3 puff from B-side upper: shot 28 4psi, 350msec wide puff; shot 29
18.5psi, 200msec wide puff. Shot 28 the He3 was visible to spectroscopists,
but not on density feedback. Shot 29 the density doubled and shut off the
A-side valve. Presumably Yuichi will want something in between for tomorrow.

General comments:
-----------------
The -1.0sec start time on the TF worked fine, and probably would have gotten
us a couple of extra shots due to reduced cooling time if we hadn't had to
wait for the TF scanner every shot. The scanner was the dominant delay today.

Startup was reliable all day, even after killer disruptions. I have no ideal
why. I was using the same Segment 1 as last Friday's run.

We got several ohmic H-modes, and more that were dithering. Shot 3 is a good
early example. See the logbook entries for more.

The voltage limits on EF1 and OH2's are still a problem. We were running at
slightly reduced alternator voltage today, as we have been since last
Thursday, but this is probably not the main problem.

Scorecard:
----------
Tests 1
Duds 0
Fizzles 0
Plasmas 28 (1warning, 1 **OUT**)
------- --
Total 29

Session Leader Comments
May 9 1995 08:23:21:340AMBruce LipschultzRun 950509

Engineering operator: V. Bertolino
Physics operator: S. Wolfe
Session leader: BLip

M.P.# 105: Effect of current and q on divertor characteristics

This m. p. has 2 parts: First we plan to study the detachment characterisitics
of plasmas at 1 MA (today's run). For the second half of the mp we will be
varying q.

The order of today's run is to obtain a 1 MA plasam with outer strike
point in the region of probes 2 & 3. From shot to shot scan the density
up through a maximum value. Take some extra shots around the 'death ray'
occurence densities. We will then attempt to switch to flat-plate
divertor equilibrium and repeat the density scan.

May 9 1995 09:08:08:890AM950509002Bruce Lipschultzshot 2: 800 kA, nl04 = 8.5e19. Right gap and SSEP a little small.

May 9 1995 09:11:28:880AM950509002Bruce Lipschultzshot 2: 800 kA, nl04 = 8.5e19. Right gap and SSEP a little small.

May 9 1995 09:19:09:480AM950509003Bruce Lipschultzshot 3: nl04=8e19. SSEP better (1.5 or so). Strike point down aroung
probe 4 and drifting.

May 9 1995 09:35:16:460AM950509003Bruce Lipschultzshot 3: nl04=8e19. SSEP better (1.5 or so). Strike point down aroung
probe 4 and drifting.

May 9 1995 09:35:57:160AM950509004Bruce Lipschultzshot 4: nl04= 8e19. Strike point on probe 3. 800 kA.

May 9 1995 10:03:05:080AM950509005Bruce Lipschultzshot 5: no change other than strike point on probe 2 now.

May 9 1995 10:03:40:650AM950509005Bruce Lipschultzshot 5: no change other than strike point on probe 2 now.

May 9 1995 10:18:17:890AM950509006Bruce Lipschultzshot 6: same but better x-point control. Next shot to 1 MA.

May 9 1995 10:30:14:940AM950509007Bruce Lipschultzshot 7: try for 1 MA failed, disruption at .37 seconds.

May 9 1995 10:56:40:980AM950509008Bruce Lipschultzshot 8: nl04= .8e20, 1MA. Still having problems with x-point position.

May 9 1995 11:31:52:950AM950509009Bruce Lipschultzshot 9: nl04=0.7e20, 1 MA. Disruption at 1.1 sec

May 9 1995 12:12:01:840PM950509010Bruce Lipschultzshot 10: disruption

May 9 1995 12:12:16:940PM950509011Bruce Lipschultzshot 11: disruption

May 9 1995 12:27:11:700PM950509012Bruce Lipschultzshot 12: 800 kA again to regroup and try again, lots of injections.

May 9 1995 12:27:39:900PM950509012Bruce Lipschultzshot 12: 800 kA again to regroup and try again, lots of injections.

May 9 1995 12:45:57:610PM950509012Bruce Lipschultzshot 12: 800 kA again to regroup and try again, lots of injections.

May 9 1995 12:46:19:540PM950509013Bruce Lipschultzshot 13: same, still tuning

May 9 1995 01:15:05:070PM950509014Bruce Lipschultzshot 14: still tuning

May 9 1995 01:16:32:850PM950509015Bruce Lipschultzshot 15: 1 MA, 7e19 on nl04.

May 9 1995 01:35:30:180PM950509016Bruce Lipschultzshot 16: Disruption at 1.1 seconds. nl04 = .7e20, FSP scan ok.

May 9 1995 01:45:31:450PM950509017Bruce Lipschultzshot 17: nl04=1.15e20. FSP scan to within 2 mm of separatrix.

May 9 1995 02:02:41:850PM950509018Bruce Lipschultzshot 18: nl04=1.25e20, FSP scan ok. Not detached.

May 9 1995 02:27:22:160PM950509019Bruce Lipschultzshot 19: nl04=1.45e20 (rises to 1.55 after .9 seconds). There does
appear to be detachment at probes 4 & 5 of the outer divertor that
shot along with a death ray on probe 4.

May 9 1995 02:51:52:270PM950509020Bruce Lipschultzshot 20: nl04 = 1.55-1.7 e20. FSP scan ok. Detachment again on probes
4 & 5 but no further up the plate!

May 9 1995 03:02:47:720PM950509020Bruce Lipschultzshot 20: nl04 = 1.55-1.7 e20. FSP scan ok. Detachment again on probes
4 & 5 but no further up the plate!

May 9 1995 03:05:04:880PM950509021Bruce Lipschultzshot 21: nl04 = 1.85 e20. FSP scan ok. Detachment again on probes
4 -6 + possibly probe 7 (but we don't have a domed probe there).

May 9 1995 03:06:21:220PM950509021Bruce Lipschultzshot 21: nl04 = 1.85 e20. FSP scan ok. Detachment again on probes
4 -6 + possibly probe 7 (but we don't have a domed probe there).

May 9 1995 03:18:04:230PM950509022Bruce Lipschultzshot 22: nl04= 2.1e20. FSP scan ok. detached up through, I think,
probes 7 & 8. The decision about probe 8 will have to await the FSP
analysis.

May 9 1995 03:29:54:070PM950509023Bruce Lipschultzshot 23: 800 kA Flat-plate divertor loaded in from last week (950503018).
nl04=1.0e20.

May 9 1995 03:31:57:120PM950509023Bruce Lipschultzshot 23: 800 kA Flat-plate divertor loaded in from last week (950503018).
nl04=1.0e20.

May 9 1995 04:05:39:200PM950509025Bruce Lipschultzshot 25: 1 MA flat-plate. nl04=1.0e20. FSP scan.

May 9 1995 04:41:18:310PM950509026Bruce Lipschultzshot 26: nl04=1.4e20, FSP scan ok, no evidence of detachment.

May 9 1995 04:42:32:300PM950509027Bruce Lipschultzshot 27: STRIKE OUT! flat-plate out. We had a BIG disruption.

May 9 1995 04:47:37:790PM950509027Bruce Lipschultzshot 27: STRIKE OUT! flat-plate out. We had a BIG disruption.

May 9 1995 04:49:35:490PM950509028Bruce Lipschultzshot 28: He3 pulse for Yuichi, 800 kA, nl04=0.7e20.

Physics Operator Comments
May 9 1995 07:20:35:440AMSteve WolfeMP#105 Divertor Detachment (1MA)
SL: BLIP
PO: Wolfe
EO: Bertolino

(-1) Engineering setup as for 950505012, except delay TF start to -1.0 sec.
A-side plenum filled to 20psi of D2. ECDC in D2.

(0) Start with Segment 1 from Friday, and Segment 2 a clone of 950502019, an
800kA shot with the desired characteristics: strike point in probe 2-3 area,
SSEP > 1.6cm, inner and outer gaps > 1.8cm. Initial changes to 950502019:
NL_04 changed from 1.5e20 to .7e20, delay RXL ramp from .95sec to 1.05sec.

Try to get a robust looking shot with NL_04=0.7e20, and the above gaps and
strikes, preferably with ZCUR between 0 and -1cm, but don't push too hard on
that.

Things to try: Increase IC_EF4 program to 2500A; Adjust RXL,ZXL gains to
reduce over-determination of controllers; eliminate RXL,ZXL control entirely
and use STRKIN; keep an eye on EF2's and perhaps adjust CLEARIN ramp to keep
them off the rail early; watch for voltage saturations and current railings;
tweak up the ramp-down to try to eliminate disruptions without RF.

May 9 1995 07:21:30:520AMSteve Wolfe(1) When satisfied with the 800kA shot, go up to 1 MA . Check the EF2's and
EF3 ramp. Consider delaying the crowbar times to get more current early.

(2) After the shot is set up and Brian has a FSP scan at nl04=0.7 we will
raise the density in steps of 0.2 until death ray has come and gone (6 - 10
shots depending if Brian needs extra shots). Then go back and fill in
density scan through death ray range in density (2 more shots).

(3) Starting where we left off density scan increase density in 0.4 steps
to maximum. Use either NINJA or B-side LOWER valve to get to high density, if
needed; note - WE WILL NOT BE USING ARGON in this run.
(2 -3 shots).

(4) Convert to flat plate scan of last Wednesday but at 1 MA. Start at
nl04=0.7 (5 shots?). It may make sense to lengthen the shot to achieve
the return scan across probe 8 properly.

(5) Step up density in 0.4 steps to maximum (5-8 shots depending on FSP
needs).

(6) Fill in density in steps of 0.2 around detachment start ( if any).

May 9 1995 07:22:08:920AMSteve WolfeColdstart done at 07:15.
First shot will be usual Tuesday OH test

May 9 1995 07:46:36:820AMSteve WolfeColdstart done at 07:15.
Additional change Loaded at 7:43: Extend CLEARIN to 1.05 sec

May 9 1995 08:38:23:050AM950509001Steve WolfeShot 950509001

Tuesday morning test looks ok

May 9 1995 08:57:15:300AM950509002Steve WolfeShot 950509002

First plasma attempt. Fill at 2.0e-5
Plasma - runs full length. Some Mo injections.
Gaps look good, SSEP only 1cm though

May 9 1995 09:11:11:720AM950509003Steve WolfeShot 950509003

Increase ZXU gain from 3 to 6 to try to improve SSEP.
Plasma runs full length. H-mode at .83sec. SSEP is better.
Outer gap still a bit small late.

May 9 1995 09:35:58:800AM950509004Steve WolfeShot 950509004

Try using STRKIN control
STRKIN on wire 11 with gain=20/sec @.350 sec
STRKPSI on wire 12 with ALL including STRKIN, P=85/sec,I=142
RXL gain down to 20/sec
ZXL gain down to zero
Plasma - Full length. Dithering from about .7, H-mode at 1.09sec
STRKIN is a little high, error around 1000. BLIP says STRKPSI is moving
about a mm during flattop (rho space)

May 9 1995 09:53:49:620AM950509005Steve WolfeShot 950509005

Continue using STRKIN control
STRKIN gain to 20/sec =5 hybrid (was actually only 8/s last time)
STRKPSI on wire 12 with ALL including STRKIN, P=85/sec,I=142
Change programming from +.0006,.0004 to 0. after .586 sec
RXL gain down to zero
ZXL gain down to zero
Plasma - Disrupted a little earlier, EF2's have a big thrash early
from .3 to .6. That's not good.

May 9 1995 10:11:54:050AM950509006Steve WolfeShot 950509006

Turn STRKIN on at before .1sec, I=1 at .54s
Plasma - disrupted earlier, 1.3sec
EF2's better, STRKIN somewhat better. Still dithering H-mode.

May 9 1995 10:33:06:480AM950509007Steve WolfeShot 950509007

INcrease I gain on STRKIN to 2, turn off both at 1.2sec
Increase Ip to 1.0MA
Increase IC_EF4 to 2200a

Dirupted early, around crossover? Only gets to 600kA
2pi bolo starts up 315msec, disruption around 369
The only change at that time is the IC_EF4

May 9 1995 10:53:30:030AM950509008Steve WolfeShot 950509008

Leave old IC_EF4 program until 400msec, then raise to 2000a at .6sec

Disrupted in ramp-down (1.15sec)

May 9 1995 11:10:40:180AM950509009Steve WolfeShot 950509009

Lower NL_04 to 6.5e19 (from 7.5e19)
Chnage STRKIN to -.002
Leave ZXU high in rampdown
Slow down CLEARIN rampdown

Still disrupting; this one at 1.06sec, just at EOF.
This looks like a VDE.

May 9 1995 11:40:37:590AM950509010Steve WolfeShot 950509010

No changes in Flattop, try to fix up rampdown
Put ZXU programming back
Extend ZCUR flat till after 1.08
Extend STRKPSI to 1.05
Leave IC_EF4 gain low through rampdown

Disrupted early, at 0.91 sec
Halo warning.

May 9 1995 11:58:13:710AM950509011Steve WolfeShot 950509011

Give up on STRKIN for now, go back to RXL only as on original shot

Still disrupting. Bad VDE at .85. EF2's both railed throughout!
And EF4 is also at max current. Don't do that again.
ZXL is very negative. Inner strike is on the EF1 shelf the whole time

Back to 800kA, try to tune up the overdetermined system.

May 9 1995 12:16:14:190PM950509012Steve WolfeShot 950509012

Back to 800kA.
Tuning up the over-determined case:
Bring in ZXL control as on 950502
Reduce RXL gain to 20/sec.

Plasma - ran through to 1.46
EF2's look happy. Lots of Mo injections
RXL too far inside?

May 9 1995 12:37:08:750PM950509013Steve WolfeShot 950509013

Increase RXL gain to 36/s at .5 sec, back down in rampdown
Plasma - ran till 1.4sec
EF2's still ok. Still several injections. Looks like another late
H-mode. RXL still inside, but better.

May 9 1995 12:48:33:250PM950509014Steve WolfeShot 950509014

Move RXL to wire 9, and turn on Integral gain at 50/sec2, between .58
and 1.05

Plasma - disrupts a little earlier (1.33)
EF2L ok, EF2U around 3000A
Still lots of injections.
RXL steady at about -10000 error

May 9 1995 01:11:35:380PM950509015Steve WolfeShot 950509015

Back to 1MA. No other changes. (Turn off shit shooter for this one)
Made it through to about 1.2sec
EF2U touches the rail at .56sec
No H-mode. FSP target is moving down

May 9 1995 01:24:00:980PM950509016Steve WolfeShot 950509016

Extend STRKPSI control to EOF
Slow down current ramp to try to fix EF2 rail
Brian will fire the FSP on this shot.

Didn't last as long, disrupts at 1.1sec
EF2U is off the rail but close the whole shot.

May 9 1995 01:42:23:250PM950509017Steve WolfeShot 950509017

Raise NL_04 to 1.1e20
Plasma - Lasted to 1.3sec
Dithering the whole shot.
Gaps a bit small, especially outside.

May 9 1995 02:00:45:140PM950509018Steve WolfeShot 950509018

Raise NL_04 to 1.25e20
Move RCUR in by 3mm to increase right gap.
Reduce peak in pre-programmed gas puff.

Plasma - PF crowbar after ramp-down disruption at 1.28
Looks like a VDE in rampdown
EF1U may be railing at end of flattop

May 9 1995 02:25:58:020PM950509019Steve WolfeShot 950509019

Raise NL_04 to 1.45e20
Slow down RCUR ramp in rampdown
Slow down CLEARIN ramp around .5 sec to reduce demand on EF2 early
Back to recool- alternator fault

Ran through to 1.35
Density starts to increase around .9
EF1U and EF1L are on the voltage rail at 200V (despite the fact EF1L
got to 260 last week)

May 9 1995 02:43:26:890PM950509020Steve WolfeShot 950509020

Try increasing margin angle on EF1 supplies
Raise NL_04 to 1.65e20

Plasma - ran to 1.3sec
Still getting a density rise late in flattop
Got a bit more voltage on EF1's, didn't saturate

May 9 1995 03:03:31:560PM950509021Steve WolfeShot 950509021

Purge B-side lower of Ar, fill with 20psi of D2
Enable B-side lower (pulse gas 1); Puff from 0.6 to 0.8
Raise NL_04 to 1.85e20
Program RXL to ramp in by 0.005 during flattop

Plasma - lasts to 1.28sec
Supplies look ok.

May 9 1995 03:15:54:110PM950509022Steve WolfeShot 950509022

Raise NL_04 to 2.05e20

Plasma - ran to 1.33
Got 2.1e20, fully detached.

May 9 1995 03:36:45:270PM950509023Steve WolfeShot 950509023

Go to flatplate
Load Seg2 from 950503018. The damn shot is already on Optical!!!
Raise ZCUR from -.015 to -.005

Plasma - ramped all the way down
EF1's are pushing, but not saturated yet.
EF2's look ok

May 9 1995 03:45:53:110PM950509024Steve WolfeShot 950509024

Go to 1MA, IC_EF4 to 2000A
Plasma - Made it!
EF2's in good shape, EF1's look ok, although EF1L is getting up there
on the reverse swing. BLIP wants to swing back further.

May 9 1995 04:02:55:600PM950509025Steve WolfeShot 950509025

Extend STRKPSI gain to 1.1 (was turning off at 1.0)
INcrease reverse sweep on STRKPSI to (1.1,-.005)
Extend NL_04 program to 1.05
BLAB will fire the FSP on this shot .7,.85,1.0sec

Plasma - ramps all the way down
Looks like it swept ok

May 9 1995 04:15:28:390PM950509026Steve WolfeShot 950509026

Increase NL_04 to 1.4e20
Plasma - ramps down all the way
SSEP down to 1.2cm, Supplies look ok

May 9 1995 04:34:20:290PM950509027Steve WolfeShot 950509027

Increase NL_04 to 1.8e20; enable B-side lower, puff from .6 to .85
Increase ZXU gain from 3 to 6 during flattop

Disrupted in flattop at 0.84sec
Halo Out. 270kA Halo current.
Looks like OH2L on voltage rail?

May 9 1995 04:55:00:410PM950509028Steve WolfeShot 950509028

Reload 950509013 (800kA, STRKSPI,RXL,ZXL control)
Slow down RCUR ramp
Puff He3 from .5 to .85sec

Plasma - ramps all the way down
No obvious sign of any Helium on Zmeter, CX, or feedback

May 9 1995 06:24:42:540PM950509029Steve WolfeShot 950509029

Increase He3 plenum pressure on B-side upper to 19psi
Shorten pulse to 200msec
Jim Terry and Garry McCracken report they saw the He line on shot 28.

Plasma - runs all the way down.
Density ran up to 1.4e20 with the He3 pulse, then comes back down to
1.1. Feedback turned the A-side valve off

Engineering Operator Comments
ShotTimeTypeStatusComment
108:34:45:700AMTestOkoh coax, efc test
208:44:38:640AMPlasmaOk
309:02:59:220AMPlasmaOk
409:22:15:050AMPlasmaOk
509:46:34:200AMPlasmaOk
610:03:57:910AMPlasmaOk
710:21:13:150AMPlasmaOk
810:40:10:150AMPlasmaOk
911:03:45:980AMPlasmaOk
1011:23:24:460AMPlasmaOk
1111:47:14:350AMPlasmaOk
1212:05:41:400PMPlasmaOk
1312:22:22:180PMPlasmaOk
1412:41:32:460PMPlasmaOkNo Faults.
1512:58:38:360PMPlasmaOkNo Faults.
1601:16:57:560PMPlasmaOkNo Faults.
1701:32:44:310PMPlasmaOkno faults.
1801:50:13:340PMPlasmaOkComm Fault OH2l&oh1
1902:06:45:650PMPlasmaOkNo Faults.
2002:31:01:680PMPlasmaOkNo Faults
2102:53:00:570PMPlasmaOkNo Faults.
2203:09:08:960PMPlasmaOkNo faults.
2303:24:35:670PMPlasmaOkNo Faults.
2403:40:24:220PMPlasmaOkNo faults.
2503:55:47:540PMPlasmaOkNo Faults.
2604:10:47:200PMPlasmaOkNo Faults.
2704:26:19:740PMPlasmaOkoh2l type 2 fault after shot unexplained
2804:45:39:860PMPlasmaOkNo Faults.
2905:01:20:610PMPlasmaOkNo Faults.