| Session leader(s): | Steve Golovato |
| Physics operator(s): | Joseph Snipes |
| Engineering operator(s): | Vinny Bertolino,Joe Daigle |
| Engineering Operator Run Comment |
| snipe |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:13:867PM |
| Author: To Be Determined |
| run summary - 950602 --------------------- SL: golovato PO: snipes EO: bertolino/daigle The goal of the run was to continue the search for better h-modes at 5.3 T, better meanig higher h-factor, or at least longer elm-free phases. Specifiically we proposed the following approaches. (1) start with shot 950523017, a higher triangularity configuration, vary outer gap to keep rf from tripping during h-mode. (2) go to higher triangularity, at the expense of elongation and running limited if necessary. (3) density scan, revisit lower densities where thresholds are lower, see how much power we can get in. We tried the above and some other things but got neither higher h-factors nor longer elm-free phases. We did get FSP and laser blowoff data. It seems clear from the laser blowoff that particle confinement is strongly enhanced and this causes both a fast density rise and impurity accumulation. Some combination of these effects may be our current limitation. Brian LaBombard has noted that we only get rf h-modes when the midplane neutral pressure falls below 0.4 mtorr. This may be true before rf, in which case we quickly go into elm-free h-mode, or it may fall during rf, in which case we get h-modes later in the rf pulse when it falls below the "magic" value of 0.4 mtorr. The new, improved 2pi bolomater is a sensitive diagnostic of elms and can be used to evaluate h-mode quality. We started out with shot 950523017 but the configuration with these settings had an inner wall x-point, which it didn't have on 950523. We did not get h-modes through shot 006 so we went back to our "standard" elm-free h-mode shot (950523009) and got back the h-modes on shots 007-009. We the went back to shot 006 and began tweaking it to get h-modes. By lowering the initial nl04 to 1.35e20 from 1.5e20 and cutting off the gas voltage programming, we got h-modes on shot 013. Shots 013-020 were a density scan down to 0.7e20. The h-modes deteriorated with decreasing density with no h-modes at the lowest density, even with 2,2 MW of power. We then tried to control the midplane pressure by better mapping the SOL flux into the divertor. We got a highly triangular plasma (ltriang=0.7) on shot 023 with the desired flux mapping, but no better h-modes. This was done mainly by moving the upper x-point more up. We then tried moving it down on shots 027 and 031, making the h-modes worse. On shots 028 and 029 we tried extreme edge gas control. We fired in a Li pellet and turned off the gas completely. On shot 028 the pellet didn't fire and we got h-modes which held up the density even though the gas was off. On shot 029, the pellet fired but we got no h-modes and the density fell to nl04=0.5e20 by the end of the shot, with 2.8 MW of power. Some suggestions include: (1) a 2.6 T run to look at h-mode thresholds and factors. We have seen good 2nd harmonic heating here and might learn a lot about B-field vs size scaling. (2) Boronization to control the Moly influx. (3) Better gas control (divertor pumping, pellet fueling) to control the density rise. We have a summer to think about it. The session leader shot-to-shot summary can be found in the logbook under the session_leader topic. Details on technical difficulties can be found in the physics operator summary. The shot summary was: 29 plasmas (3 early disruptions, 1 runaway) 2 fizzles RUN: 950602 SHOT: 950602001 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 08:54:58.40 TEXT: shot 950602001 - loaded shot 950523017 plasma and rf worked. no h-modes. 2.3mw, 1.5e20 got x-point on upper inner wall, unlike shot 950523017. got disruptions with configurations like this last time. RUN: 950602 SHOT: 950602002 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 09:03:12.12 TEXT: shot 950602002 - disrupted early before rf looks like moly injection, we'll have moly mon next shot. RUN: 950602 SHOT: 950602003 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 09:19:31.35 TEXT: shot 950602003 - plasma, no h-modes, 2.1mw. still have upper inner wall x-point. will try to get rid of it. RUN: 950602 SHOT: 950602004 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 09:36:28.58 TEXT: shot 950602004 - plasma, 2.2mw. similar to shot 003. inner wall x-point later in time, making progress. camac problems for rf data on shots 003 and 004, timing incorrect. RUN: 950602 SHOT: 950602005 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 09:49:41.69 TEXT: shot 950602005 - plasma, 2.2mw. no h-modes. rf camac problems continue. RUN: 950602 SHOT: 950602006 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 10:02:12.26 TEXT: shot 950602006- plasma, 2.2mw. same as previous shots. rf data timing fixed. RUN: 950602 SHOT: 950602007 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 10:26:00.36 TEXT: shot 950602007- reload shot 950523009, the standard configuration which gave multiple h-modes. see if we still get them. plasma, h-modes. daq1 problems this shot. RUN: 950602 SHOT: 950602008 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 10:40:19.76 TEXT: shot 950602008 - repeat but moved upper x-point up a little, see effect on h-modes. plasma, multiple h-modes. 2.5mw, some rf trips. RUN: 950602 SHOT: 950602008 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 10:50:23.90 TEXT: shot 950602008 - repeat but moved upper x-point up a little, see effect on h-modes. plasma, multiple h-modes. 2.5mw, some rf trips. RUN: 950602 SHOT: 950602009 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 11:05:00.69 TEXT: shot 950602009 - repeat. plasma. continuous elmy h-mode. 2.65mw. RUN: 950602 SHOT: 950602010 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 11:06:53.35 TEXT: shot 950602010 - back to shot 006, higher triangularity. move plasma out at 750ms. plasma, no rf. no h-modes. RUN: 950602 SHOT: 950602011 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 11:33:18.28 TEXT: shot 950602011 - lower nl04 to 1.4 form 1.5e20. shots with h-mode today and on 950523 had lower nl04. brian has been telling us the last two h-mode runs that getting h-modes is well correlated with midplane pressure. we get them when it is below 0.4mtorr. this is consistent with today's data. we get higher edge pressure when the upper x-point is closer in. plasma, no h-mode. RUN: 950602 SHOT: 950602012 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 11:39:37.96 TEXT: shot 950602012 - lower nl04 to 1.4 form 1.5e20. this was not done for previous shot. plasma. 2.55mw. got very brief h-mode at 930ms. we're moving in right direction, still have nl too high. RUN: 950602 SHOT: 950602013 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 12:00:39.93 TEXT: shot 950602013 - nl04 to 1.35, less pre-programmed gas. plasma, h-modes, two elm-free periods. midplane gas below 0.4mtorr nl04=1.4e20, 2.55mw. RUN: 950602 SHOT: 950602014 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 12:18:54.48 TEXT: shot 950602014 - lower nl, gas off earlier. plasma, 3 h-modes. rf trips end elm-free periods. RUN: 950602 SHOT: 950602015 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 12:34:50.91 TEXT: shot 950602015 - tune rf to avoid trips. plasma, 4 elm-free periods, no trips. 2.55mw. RUN: 950602 SHOT: 950602016 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 12:48:32.96 TEXT: shot 950602016 - lower nl04 to 1.1e20. plasma, initial elm-free density rise followed by jumps back and forth from l to h, but no clear elmy phases. 2pi bolo sees oscillation from low level elms to elm-free which correlate with density downs and ups. RUN: 950602 SHOT: 950602017 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 12:56:07.68 TEXT: shot 950602017 - lower nl04 to 0.9e20. runaway shot. RUN: 950602 SHOT: 950602018 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 13:10:44.25 TEXT: shot 950602018 - try again. plasma. early disruption. RUN: 950602 SHOT: 950602019 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 13:21:19.56 TEXT: shot 950602019 - plasma, dithering. 2.25mw, nl04=1.e20 RUN: 950602 SHOT: 950602020 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 13:36:46.04 TEXT: shot 950602020 - lower to nl04 to 0.7e20. plasma, early disruption, moly injection. RUN: 950602 SHOT: 950602021 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 13:58:30.35 TEXT: shot 950602021 - try again. plasma, disrupted at 860ms. no h-mode at 2.2mw, nl04=0.7e20. RUN: 950602 SHOT: 950602022 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 14:13:42.84 TEXT: shot 950602022 - reload shot 015, which had nl04=1.25e20. moving plasma up and lower x-point in to get more sol flux to map into divertor. fizzle. RUN: 950602 SHOT: 950602023 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 15:10:46.78 TEXT: shot 950602023 - plasma, some hards, h-modes. 2.25mw. got more flux into divertor on outside. h-modes not as good. RUN: 950602 SHOT: 950602024 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 15:28:01.13 TEXT: shot 950602024 - move upper x-point further out to get more sol to map around to inner lower divertor, which is on top of nose for this configuration. lower triang = 0.7 for last shot. plasma. several h-modes but not longer. RUN: 950602 SHOT: 950602025 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 15:47:02.57 TEXT: shot 950602025 - more configuration twiddling. plasma, several h-modes. much like the last shot. RUN: 950602 SHOT: 950602026 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 15:59:41.87 TEXT: shot 950602026 - raise density to nl04=1.4e20 plasma with several h-modes, simlar to other shots. 40ms elm-free RUN: 950602 SHOT: 950602027 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 16:22:14.03 TEXT: shot 950602027 - move upper x-point down instead of up as we have been moving it. plasma, no h-modes. 2.6mw. midplane pressure much higher. RUN: 950602 SHOT: 950602028 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 16:45:12.27 TEXT: shot 950602028 - reload shot 026, shoot Li pellet at 650ms and turn off gas. fire rf at 750ms after pellet density decays but with no gas fueling. plasma. several h-modes. 2.65mw. RUN: 950602 SHOT: 950602029 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 16:47:05.90 TEXT: shot 950602029 - last shot had no pellet. this one with pellet had no h-modes and density fell to nl04=0.5e20. 2.8mw RUN: 950602 SHOT: 950602030 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 16:49:05.77 TEXT: shot 950602030 - reload shot 026 and adjust zxu to be about half the change made for shot 027, lowering it by 3.cm instead of 5cm. fizzle. RUN: 950602 SHOT: 950602031 TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 17:03:30.33 TEXT: shot 950602031 - try it again. plasma, two wimpy h-modes. 2.7mw. RUN: 950602 SHOT: NULL TOPIC: SESSION_LEADER USERNAME: GOLOVATO ENTERED: 2-JUN-1995 08:39:43.83 |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:54:660PM |
| Author: To Be Determined |
| MP078A ICRF H-mode Run Engineer in charge: Vince Bertolino Physics Operator: Joseph Snipes Session Leader: Steve Golovato This run will take over from where we left off on 950523 and we will set up with shot 950523017. ECDC was performed in deuterium for 1 hour and 45 min. before the run, then shut off by 7:45 am or so to allow the machine to pump out before the run. The plan is to first start with our previous good shot, 950523017 with relatively high triangularity, high density (nl = 1.4 x 10^20 m^-2), 1 MA, 5.3 T, and try to keep the RF power up and maintain ELM-free H-modes. We will then scan the density down to as low as nl = 8 x 10^19 m^-2. After spending a number of shots trying to increase the ELM-free H-mode durations, we will then change to a limited or nearly inner wall limited plasma shifted above the midplane with low elongation and high triangularity. For this, we will start with shot 950526031, shifting the plasma up and trying to increase the triangularity to attempt to reach triangularities above 0.7. This requires running above the nose of the divertor. If we succeed in getting decent plasmas under these conditions, we will again scan the density to try to optimize ICRF H-modes with high triangularity. It was a very good run. We succeeded in accomplishing much of what was planned. However, the H-modes were not significantly better than in previous runs. We did learn some things about getting H-modes. The most important thing appears to be that the midplane neutral pressure does indeed correlate with getting the H-mode and that the midplane pressure correlates with how much flux maps from the inboard to the outboard plate. By comparing shots 26, 27 and 31, one sees that the more flux that maps around from the inboard to the outboard plate, the lower the neutral pressure at the midplane and the better the H-mode. This difference in the recycling outweighed differences in the triangularity. Still, the ELM-free H-modes only lasted at most 40 - 50 msec. The direction to head seems to be to increase the inner gap, increase the amount of flux that maps around the plasma from the inner to the outer plate, and then try to also increase the triangularity beyond 0.7. From the technical side, the machine ran quite well, though there were a couple of problems. About shot 22, Earl noticed that the TF was at 5.1 T rather than 5.3 T. In fact, it had been low since shot 15. We spent some time looking into it, but then decided to ask for more TF current to get the field that we wanted. That worked fine until shot 31, when we actually got 5.5 T. This problem should be looked into some more. There was also a disruption caused by an EF1U fault on shot 29 that was resolved immediately. There were 31 shots, 30 plasmas, and 1 Fizzle. There were no warnings or strikes. Shot 1 : Copied shot 950523017. Good shot. No H-mode with 2.3 MW of RF 2 : Removed step in RCUR from 0.75 to 1.05 sec. Disrupted at 0.74 sec. Probably a moly injection at 0.69 sec. 3 : Try again. Good shot. No H-mode. RF at 2 MW (timing error). 4 : Moved ZXU up from 0.5 sec to 4.5 cm then up to 4.75 cm from 0.6 to 1 sec. Extended gas pre-programming on both A side and B top valves to 1 sec. No H-mode with 2.3 MW of RF. RF timing error. 5 : Moved ZXU up to 5 cm from 0.6 to 1 sec. Good shot. No H-mode. RF up to 2.3 MW. 6 : Moved RXU out by 0.5 cm and ZXU up by 0.5 cm. Good shot. No H-mode. RF up to 2.3 MW. Good configuration with high triangularity. 7 : Reloaded shot 950523009. Good shot. ELM-free 0.8 - 0.85 sec then ELMy 0.9 to 1.01 sec. 8 : Moved ZXU up to 5.5 cm from 0.5 to 1 sec. Zirconium injection at 0.94 sec. Good shot. ELM-free and ELMy H-modes from 0.79 - 1.02 sec. Zirconium at 0.94 sec. 9 : Repeat. Good shot. ELMy H-mode from 0.79 - 0.95 sec. 10: Returned to shot 6 with a step in RCUR from 0.75 to 1.05 sec. No RF. No H-mode. 11: Repeat. Good shot. No H-mode. 12: Lowered nel to 1.4 x 10^20 m^-2. Good shot. Short H-mode 0.94 - 0.95 sec. 13: Reduced nel to 1.35 x 10^20 m^-2. Turned off pre-programmed gas feed at 0.8 sec. Good shot. H-modes 0.88 - 0.92 and 0.99 - 1.01 sec. 14: Reduced nel to 1.25 x 10^20 m^-2. Turned off pre-programmed gas feed at 0.75 sec. Good shot. 3 ELM-free H-modes 0.85 - 1.01 sec. 15: Repeat to tune RF. Good shot. 4 ELM-free H-modes 0.85 - 1.01 sec. 16: Lowered nel to 1.1 x 10^20 m^-2. Good shot. In and out of H-mode from 0.85 - 1.03 sec. 17: Lowered nel to 0.9 x 10^20 m^-2. Bad shot. Hard x rays from the current rise. Disrupted at 0.38 sec. 18: Try again. Increased prefill to 1.9 x 10^-5 Torr. Bad shot. Disrupted at 0.48 sec. 19: Reduced early gas a bit. OK shot. 2.2 MW of RF with dithering. Very high radiated power. 20: Reduced nel to 7 x 10^19 m^-2. Bad shot. Disrupted at 0.6 sec. 21: Try again. Bad shot. Disrupted at 0.86 sec during RF. 22: Returning to shot 15 with B top enabled. RXL moved in 2 cm, ZXL moved up 3 cm, and ZCUR moved up to +0.5 cm. ZXU moved up by 2 cm to 7.5 cm. There is a problem with the TF in that the field only reaches 5.1 T. The problem has been there since shot 15. Short delay to investigate. 23: Prefill set to 1.7 x 10^-5 Torr. Good shot. 2 ELM-free H-modes from 0.85 - 0.92 sec. 24: Prefill set to 1.8 x 10^-5 Torr. Changed ZXU controller reference to 0.44 m and shifted the waveform to start at -5 cm and ramp to + 5 cm. Good shot. Several H-modes from 0.81 - 0.99 sec. 25: Increased ZXU to 7.5 cm. Moved ramp in RXL to 0.45 sec. Good shot. H-modes from 0.81 to 1.01 sec. 26: Increased nel to 1.4 x 10^20 m^-2. Good shot. H-modes from 0.82 - 1.01 sec. 27: Lowered ZXU to 0. No H-mode. RF up to 2.5 MW. No H-mode. Neutral pressure much higher apparently prevented the H-mode through changes in recycling. 28: Reloaded shot 26. Gas and density feedback shut off at 0.65 sec. Med Li pellet at 0.65 sec. No pellet. H-modes from 0.82 - 0.97 sec. 29: Li pellet at 0.65 sec. 2.8 MW of RF. No H-mode. Disrupted at 1.03 sec. EF1U fault at 1.0 sec. 30: Reloaded shot 26, then set ZXU to 2 cm. Fizzle. 31: Try again. Good shot. Two very short H-modes 0.83 - 0.84 and 0.9 - 0.91 sec. |
| Session Leader Comments | |||
| Jun 2 1995 08:39:43:830AM | Steve Golovato | run 950602 - continue search for better h--modes at 5.3 T
(1) start with shot 950523017, a higher triangularity configuration, vary outer gap to keep rf from tripping during h-mode. (2) go to higher triangularity, at the expense of elongation and running limited if necessary. (3) density scan, revisit lower densities where thresholds are lower, see how much power we can get in. | |
| Jun 2 1995 08:54:58:400AM | 950602001 | Steve Golovato | shot 950602001 - loaded shot 950523017
plasma and rf worked. no h-modes. 2.3mw, 1.5e20 got x-point on upper inner wall, unlike shot 950523017. got disruptions with configurations like this last time. |
| Jun 2 1995 09:03:12:120AM | 950602002 | Steve Golovato | shot 950602002 - disrupted early before rf
looks like moly injection, we'll have moly mon next shot. |
| Jun 2 1995 09:19:31:350AM | 950602003 | Steve Golovato | shot 950602003 - plasma, no h-modes, 2.1mw. still have
upper inner wall x-point. will try to get rid of it. |
| Jun 2 1995 09:36:28:580AM | 950602004 | Steve Golovato | shot 950602004 - plasma, 2.2mw. similar to shot 003.
inner wall x-point later in time, making progress. camac problems for rf data on shots 003 and 004, timing incorrect. |
| Jun 2 1995 09:49:41:690AM | 950602005 | Steve Golovato | shot 950602005 - plasma, 2.2mw. no h-modes.
rf camac problems continue. |
| Jun 2 1995 10:02:12:260AM | 950602006 | Steve Golovato | shot 950602006- plasma, 2.2mw. same as previous shots.
rf data timing fixed. |
| Jun 2 1995 10:26:00:360AM | 950602007 | Steve Golovato | shot 950602007- reload shot 950523009, the standard configuration
which gave multiple h-modes. see if we still get them. plasma, h-modes. daq1 problems this shot. |
| Jun 2 1995 10:40:19:760AM | 950602008 | Steve Golovato | shot 950602008 - repeat but moved upper x-point up a little, see
effect on h-modes. plasma, multiple h-modes. 2.5mw, some rf trips. |
| Jun 2 1995 10:50:23:900AM | 950602008 | Steve Golovato | shot 950602008 - repeat but moved upper x-point up a little, see
effect on h-modes. plasma, multiple h-modes. 2.5mw, some rf trips. |
| Jun 2 1995 11:05:00:690AM | 950602009 | Steve Golovato | shot 950602009 - repeat. plasma. continuous elmy h-mode.
2.65mw. |
| Jun 2 1995 11:06:53:350AM | 950602010 | Steve Golovato | shot 950602010 - back to shot 006, higher triangularity.
move plasma out at 750ms. plasma, no rf. no h-modes. |
| Jun 2 1995 11:33:18:280AM | 950602011 | Steve Golovato | shot 950602011 - lower nl04 to 1.4 form 1.5e20. shots with h-mode
today and on 950523 had lower nl04. brian has been telling us the last two h-mode runs that getting h-modes is well correlated with midplane pressure. we get them when it is below 0.4mtorr. this is consistent with today's data. we get higher edge pressure when the upper x-point is closer in. plasma, no h-mode. |
| Jun 2 1995 11:39:37:960AM | 950602012 | Steve Golovato | shot 950602012 - lower nl04 to 1.4 form 1.5e20. this was not done
for previous shot. plasma. 2.55mw. got very brief h-mode at 930ms. we're moving in right direction, still have nl too high. |
| Jun 2 1995 12:00:39:930PM | 950602013 | Steve Golovato | shot 950602013 - nl04 to 1.35, less pre-programmed gas.
plasma, h-modes, two elm-free periods. midplane gas below 0.4mtorr nl04=1.4e20, 2.55mw. |
| Jun 2 1995 12:18:54:480PM | 950602014 | Steve Golovato | shot 950602014 - lower nl, gas off earlier.
plasma, 3 h-modes. rf trips end elm-free periods. |
| Jun 2 1995 12:34:50:910PM | 950602015 | Steve Golovato | shot 950602015 - tune rf to avoid trips.
plasma, 4 elm-free periods, no trips. 2.55mw. |
| Jun 2 1995 12:48:32:960PM | 950602016 | Steve Golovato | shot 950602016 - lower nl04 to 1.1e20.
plasma, initial elm-free density rise followed by jumps back and forth from l to h, but no clear elmy phases. 2pi bolo sees oscillation from low level elms to elm-free which correlate with density downs and ups. |
| Jun 2 1995 12:56:07:680PM | 950602017 | Steve Golovato | shot 950602017 - lower nl04 to 0.9e20.
runaway shot. |
| Jun 2 1995 01:10:44:250PM | 950602018 | Steve Golovato | shot 950602018 - try again.
plasma. early disruption. |
| Jun 2 1995 01:21:19:560PM | 950602019 | Steve Golovato | shot 950602019 - plasma, dithering. 2.25mw, nl04=1.e20
|
| Jun 2 1995 01:36:46:040PM | 950602020 | Steve Golovato | shot 950602020 - lower to nl04 to 0.7e20.
plasma, early disruption, moly injection. |
| Jun 2 1995 01:58:30:350PM | 950602021 | Steve Golovato | shot 950602021 - try again.
plasma, disrupted at 860ms. no h-mode at 2.2mw, nl04=0.7e20. |
| Jun 2 1995 02:13:42:840PM | 950602022 | Steve Golovato | shot 950602022 - reload shot 015, which had nl04=1.25e20. moving
plasma up and lower x-point in to get more sol flux to map into divertor. fizzle. |
| Jun 2 1995 03:10:46:780PM | 950602023 | Steve Golovato | shot 950602023 - plasma, some hards, h-modes. 2.25mw.
got more flux into divertor on outside. h-modes not as good. |
| Jun 2 1995 03:28:01:130PM | 950602024 | Steve Golovato | shot 950602024 - move upper x-point further out to get more sol
to map around to inner lower divertor, which is on top of nose for this configuration. lower triang = 0.7 for last shot. plasma. several h-modes but not longer. |
| Jun 2 1995 03:47:02:570PM | 950602025 | Steve Golovato | shot 950602025 - more configuration twiddling.
plasma, several h-modes. much like the last shot. |
| Jun 2 1995 03:59:41:870PM | 950602026 | Steve Golovato | shot 950602026 - raise density to nl04=1.4e20
plasma with several h-modes, simlar to other shots. 40ms elm-free |
| Jun 2 1995 04:22:14:030PM | 950602027 | Steve Golovato | shot 950602027 - move upper x-point down instead of up as we have been
moving it. plasma, no h-modes. 2.6mw. midplane pressure much higher. |
| Jun 2 1995 04:45:12:270PM | 950602028 | Steve Golovato | shot 950602028 - reload shot 026, shoot Li pellet at 650ms and turn off
gas. fire rf at 750ms after pellet density decays but with no gas fueling. plasma. several h-modes. 2.65mw. |
| Jun 2 1995 04:47:05:900PM | 950602029 | Steve Golovato | shot 950602029 - last shot had no pellet. this one with pellet
had no h-modes and density fell to nl04=0.5e20. 2.8mw |
| Jun 2 1995 04:49:05:770PM | 950602030 | Steve Golovato | shot 950602030 - reload shot 026 and adjust zxu to be about half the
change made for shot 027, lowering it by 3.cm instead of 5cm. fizzle. |
| Jun 2 1995 05:03:30:330PM | 950602031 | Steve Golovato | shot 950602031 - try it again.
plasma, two wimpy h-modes. 2.7mw. |
| Physics Operator Comments | |||
| Jun 2 1995 08:56:02:440AM | 950602001 | Joseph Snipes | MP078A ICRF H-mode Run
Engineer in charge: Vince Bertolino Physics Operator: Joseph Snipes Session Leader: Steve Golovato Shot 1 Copied shot 950523017. Good shot. |
| Jun 2 1995 09:05:57:020AM | 950602002 | Joseph Snipes | Shot 2
Removed the step in RCUR from 0.75 sec to 1.05 sec. to try to increase the outer gap. Disrupted at 0.74 sec. Probably a moly injection at 0.69 sec. |
| Jun 2 1995 09:32:43:230AM | 950602004 | Joseph Snipes | Shot 4
Moved ZXU up from 0.5 sec to 4.5 cm then up to 4.75 cm from 0.6 to 1 sec. Extended gas pre-programming on both A side and B top valves to 1 sec. Good shot. No H-mode with 2.3 MW of RF. RF timing error. |
| Jun 2 1995 09:59:50:460AM | 950602005 | Joseph Snipes | Shot 5
Moved ZXU up to 5 cm from 0.6 to 1 sec. Good shot. No H-mode. RF up to 2.3 MW. |
| Jun 2 1995 10:11:03:260AM | 950602006 | Joseph Snipes | Shot 6
Moved ZXU up by 0.5 cm and RXU out by 0.5 cm. Good shot. No H-mode. RF up to 2.3 MW. Good configuration with high triangularity. |
| Jun 2 1995 10:26:22:750AM | 950602007 | Joseph Snipes | Shot 7
Reloaded shot 950523009. Good shot. ELM-free 0.8 - 0.85 sec then ELMy 0.9 to 1.01 sec. |
| Jun 2 1995 10:41:49:490AM | 950602008 | Joseph Snipes | Shot 8
Moved ZXU up to 5.5 cm from 0.5 to 1 sec. Zirconium injection at 0.94 sec. Good shot. ELM-free and ELMy H-modes from 0.79 - 1.02 sec. |
| Jun 2 1995 11:07:00:090AM | 950602009 | Joseph Snipes | Shot 9
Repeat. Good shot. ELMy H-mode from 0.79 - 0.95 sec. |
| Jun 2 1995 11:08:50:660AM | 950602010 | Joseph Snipes | Shot 10
Returned to shot 6 with a step in RCUR from 0.75 to 1.05 sec. Good shot. No RF. No H-mode. |
| Jun 2 1995 11:35:57:660AM | 950602011 | Joseph Snipes | Shot 11
Repeat. Good shot. No H-mode. |
| Jun 2 1995 11:38:53:220AM | 950602012 | Joseph Snipes | Shot 12
Lowered nel to 1.4 x 10^20 m^-2. Good shot. Short H-mode 0.94 - 0.95 sec. |
| Jun 2 1995 11:58:22:620AM | 950602013 | Joseph Snipes | Shot 13
Lowered nel to 1.35 x 10^20 m^-2. Turned off pre-programmed gas feed at 0.8 sec. Good shot. H-modes 0.88 - 0.92 and 0.99 - 1.01 sec. |
| Jun 2 1995 12:08:52:460PM | 950602014 | Joseph Snipes | Shot 14
Lowered nel to 1.25 x 10^20 m^-2. Turned off pre-programmed gas feed at 0.75 sec. Good shot. 3 ELM-free H-modes 0.85 - 1.01 sec. |
| Jun 2 1995 12:42:07:120PM | 950602015 | Joseph Snipes | Shot 15
Repeat to tune RF. Good shot. 4 ELM-free H-modes 0.85 - 1.01 sec. |
| Jun 2 1995 12:45:48:600PM | 950602016 | Joseph Snipes | Shot 16
Lowered nel to 1.1 x 10^20 m^-2. Good shot. In and out of H-mode from 0.85 - 1.03 sec. |
| Jun 2 1995 12:55:23:950PM | 950602017 | Joseph Snipes | Shot 17
Lowered nel to 0.9 x 10^20 m^-2. Bad shot. Hard x rays from the current rise. Disrupted at 0.38 sec. |
| Jun 2 1995 01:08:51:550PM | 950602018 | Joseph Snipes | Shot 18
Try again. Bad shot. Disrupted at 0.48 sec. |
| Jun 2 1995 01:10:36:040PM | 950602018 | Joseph Snipes | Shot 18
Try again. Bad shot. Disrupted at 0.48 sec. Increased prefill to 1.9 x 10^-5 Torr. |
| Jun 2 1995 01:25:27:800PM | 950602019 | Joseph Snipes | Shot 19
Reduced early gas a bit. OK shot. 2.2 MW of RF, dithering during RF. Very high radiated power. |
| Jun 2 1995 01:39:17:220PM | 950602020 | Joseph Snipes | Shot 20
Reduced nel to 7 x 10^19 m^-2. Bad shot. Disrupted at 0.6 sec. |
| Jun 2 1995 01:49:51:700PM | 950602021 | Joseph Snipes | Shot 21
Bad shot. Disrupted at 0.86 sec. during the RF. |
| Jun 2 1995 02:33:35:340PM | 950602022 | Joseph Snipes | Shot 22
Returning to shot 15 with B top enabled. RXL moved in 2 cm, ZXL moved up 3 cm, and ZCUR moved up to +0.5 cm. ZXU moved up by 2 cm to 7.5 cm. Fizzle. There is a problem with the TF in that the field only reaches 5.1 T. The problem has been there since shot 15. Short delay to investigate. |
| Jun 2 1995 03:11:24:500PM | 950602023 | Joseph Snipes | Shot 23
Prefill set to 1.7 x 10^-5 Torr. Good shot. 2 ELM-free H-modes from 0.85 - 0.92 sec. |
| Jun 2 1995 03:26:42:190PM | 950602024 | Joseph Snipes | Shot 24
Prefill set to 1.8 x 10^-5 Torr. Changed ZXU controller reference to 0.44 m and shifted the waveform to start at - 5 cm and ramp to + 5 cm. Good shot. Several H-modes from 0.81 - 0.99 sec. |
| Jun 2 1995 04:01:41:500PM | 950602025 | Joseph Snipes | Shot 25
Increased ZXU to 7.5 cm. Moved ramp in RXL to 0.45 sec. Good shot. H-modes from 0.81 to 1.01 sec. |
| Jun 2 1995 04:05:51:380PM | 950602026 | Joseph Snipes | Shot 26
Increased nel to 1.4 x 10^20 m^-2. Good shot. H-modes from 0.81 to 1.01 sec. |
| Jun 2 1995 04:21:11:250PM | 950602027 | Joseph Snipes | Shot 27
Lowered ZXU to 0. Good shot. RF up to 2.5 MW. No H-mode. Neutral pressure much higher apparently prevented the H-mode through changes in recycling. |
| Jun 2 1995 04:36:30:840PM | 950602028 | Joseph Snipes | Shot 28
Reloaded shot 26. Gas and density feedback shut off at 0.65 sec. Med Li pellet at 0.65 sec. No pellet. H-modes from 0.82 - 0.97 sec. |
| Jun 2 1995 04:46:37:400PM | 950602029 | Joseph Snipes | Shot 29
Medium Li pellet at 0.65 sec. 2.8 MW of RF. No H-mode. Disrupted at 1.03 sec. |
| Jun 2 1995 04:55:22:420PM | 950602029 | Joseph Snipes | Shot 29
EF1U failed at 1.0 sec, leading to the disruption. |
| Jun 2 1995 04:49:56:070PM | 950602030 | Joseph Snipes | Shot 30
Reloaded shot 26, then set ZXU to 2 cm. Fizzle. |
| Jun 2 1995 05:09:59:910PM | 950602031 | Joseph Snipes | Shot 31
Try again. Good shot. Two very short H-modes 0.83 - 0.84 and 0.9 - 0.91 sec. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:38:02:560AM | Plasma | Ok | |
| 2 | 08:56:37:280AM | Plasma | Ok | |
| 3 | 09:07:21:630AM | Plasma | Ok | |
| 4 | 09:22:27:110AM | Plasma | Ok | |
| 5 | 09:35:27:070AM | Plasma | Ok | |
| 6 | 09:56:21:760AM | Plasma | Ok | |
| 7 | 10:10:22:660AM | Plasma | Ok | |
| 8 | 10:28:52:410AM | Plasma | Ok | |
| 9 | 10:43:55:670AM | Plasma | Ok | |
| 10 | 11:01:32:040AM | Plasma | Ok | |
| 11 | 11:16:39:940AM | Plasma | Ok | |
| 12 | 11:29:53:610AM | Plasma | Ok | |
| 13 | 11:43:02:790AM | Plasma | Ok | |
| 14 | 12:00:17:920PM | Plasma | Ok | |
| 15 | 12:16:32:080PM | Plasma | Ok | |
| 16 | 12:32:39:000PM | Plasma | Ok | |
| 17 | 12:46:27:970PM | Plasma | Ok | |
| 18 | 12:56:27:380PM | Plasma | Ok | |
| 19 | 01:08:20:040PM | Plasma | Ok | |
| 20 | 01:28:12:580PM | Plasma | Ok | |
| 21 | 01:38:41:640PM | Plasma | Ok | |
| 22 | 02:07:10:940PM | Plasma | Ok | |
| 23 | 02:42:49:080PM | Plasma | Bad | tf current low |
| 24 | 03:11:53:010PM | Plasma | Ok | |
| 25 | 03:30:19:720PM | Plasma | Ok | |
| 26 | 03:43:07:160PM | Plasma | Ok | |
| 27 | 04:00:35:140PM | Plasma | Ok | |
| 28 | 04:23:17:910PM | Plasma | Ok | |
| 29 | 04:36:29:950PM | Plasma | Ok | Ef1U one SCR not conducting |
| 30 | 04:47:33:090PM | Plasma | Ok | |
| 31 | 04:57:40:460PM | Plasma | Ok | |