Alcator C-Mod Run 951221 Information

Back to runs

Miniproposals
Miniproposal:125a
Date Filed:11/27/1995
Title:ICRF Reversed Shear Mode
First Author:Miklos Porkolab
Session Leader:Steve Wolfe (shots 1-38)
Miniproposal:126
Date Filed:11/20/1995
Title:Discharge Development -- Hybrid B
First Author:Steve Wolfe
Session Leader:Steve Wolfe (shots 1-38)

Operators
Session leader(s):Steve Wolfe,Steve Wolfe
Physics operator(s):Ian Hutchinson
Engineering operator(s):Vinny Bertolino,Joe Daigle,Frank Silva

Engineering Operator Run Comment
fast current ramps

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:14:883PM
Author: To Be Determined
Session Leader's Summary for 951221

MP 126 Fast Current Ramp
MP 125A ICRF Reverse Shear Mode
SL wolfe
PO Hutch
EO Silva/Bertolino/Daigle

The goal of this run was to produce reverse shear plasmas heated with ICRF and
look for enhanced confinement. The plan was as follows:

Start from a fiducial shot setup
Tune up the starting equilibrium to
a) Elongate and divert as early as possible
CLEARIN on wire 4 in Seg 1
Crowbar EF1's earlier
b) Move out to match antenna as early as possible
Low-level RF to check loading
Turn on High power RF during early ramp up
Vary early density programming
Monitor Moly brightness, RF loading, runaways

For all of the above steps,monitor Moly levels,heating, Te(r) profiles,
sawtooth onset, any signs of improved confinement.

This was a very frustrating run. The main goal was not achieved, although some
interesting discharges were produced that will bear further analysis. These
are called out below. We were plagued by vertical instabilities which caused
early disruptions for the first three-quarters of the run. These were found to
be at least partially due to secondary effects of wall conditioning, and not
directly to the equilibria being requested. In particular, the fiducial shot
setup exhibited the same vertical disruption when it was reloaded at shot 24.
There was only one successful plasma in this portion of the run, namely shot
3, and it also had incipient vertical problems. These shots were also
characterized by hard xrays. Interestingly, many of them had hollow
temperature profiles before the disruptions, and #3 was hollow to around
160msec.

We finally loaded a low elongation limiter equilibrium 951207015 at shot 29.
This ran almost full length, until disrupting after the EF1U supply faulted.
This shot also had some hards, and just made it past the vertical problems
around 180msec. It also had hollow te profiles until around 450msec! While
this was probably due to high central radiation, this was an interesting shot.
It also had substantial non-thermals and may have been in slide-away regime.

Shot 30 was a repeat shot, but in this case the te profiles were more normal
and the xrays reduced, although not gone.

Shot 31 was the same equilibrium at
higher density, .6e20; it had hollow te profile until .35sec and started sawtoothing
after .45 sec.

Shot 32 was a repeat of 31, but with the RF on from .11 sec;
the rf ran for the whole length of the shot (about .9sec at 1MW). The te
peaked up with the rf, but sawteeth were delayed to around .4 sec.

Shot 33 raised the density to 8e19. The rf again stayed on nicely. Sawteeth
started at .23 sec, and there was some high frequency hash on the halpha that
started at the same time as the sawteeth, but didn't look like sawteeth. This
shot was almost completely free of non-thermals. It also had humongous early
moly.

For shot 34, we went back to the original program by reloading shot 3, but
leaving the rf on early. The sawteeth started around .2 secm when the te0 was
up to nearly 4keV. Again the moly and core radiation were very high. The RF
tripped around 0.4sec, and was an h-mode with repetitively faulting rf
starting around .65. Since shot 3 had previously been reloaded at shot 18 and
had disrupted at .18sec, the fact that this shot ran at all is an indication
that the wall conditions were playing a crucial role.

Shot 35 was a fiducial shot, obtained by reloading 24. This one ran.

Shot 36 was back to the program, reloaded 34 and filled in the early density
dip. While there were no sawteeth till 220msec, the te profile was always
peaked, as it had been on the fiducial.

Shot 37 had the EF1's crowbarring at 80msec, which had previously produced
higher early elongation but also disruptions. This time it ran nicely. Again
sawteeth started at .22 sec, but the te was hollow before the rf, and reached
3.8keV before the first tooth.

Shot 38 was an attempt to flattop the current at .5MA after the fast rise, but
it fell victim to the vertical instability and disrupted at 280msec. It did
however get to 3.5keV and had hollow te(r) before the rf.

There were problems with the e-port rf today: first the tuner stopped giving a
position readout, and then the transmitter died. Therefore, almost the entire
run used only D-port antenna, limiting the power to about 1.3MW. However, it
proved possible to couple the rf in quite early, despite low loading.

See the PHYSOP report and the logbook under SESSION_LEADER for a more detailed
descriptions of the machinations in the first part of the run.



Physics Operator Summaries
Entered: Jul 7 2004 04:36:55:690PM
Author: To Be Determined
Physop 951221

MP126 +125A

SL Wolfe
PO Hutch

Wolfe's instructions:
____________________
Start from a fiducial shot setup
Tune up the starting equilibrium to
a) Elongate and divert as early as possible
CLEARIN on wire 4 in Seg 1
Crowbar EF1's earlier
b) Move out to match antenna as early as possible
Low-level RF to check loading
Turn on High power RF during early ramp up
Vary early density programming
Monitor Moly brightness, RF loading, runaways

For all of the above steps,monitor Moly levels,heating, Te(r) profiles,
sawtooth onset, any signs of improved confinement.

If there are any signs of improved confinement, or of reverse shear,
and if there is time, try firing Li pellets for (probably destructive) Bz
measurements.

Tried most of this but with a lot of vertical instability problems.

Summary
_______

Most of the first 2/3 of the run was spent with vertical instabilities
early (.1-.18s). In the end, even the fiducial suffered the same problem.
Therefore we loaded a low elongation shot and then managed to get it to
run. After a few shots like this which gradually seemed to condition the
walls and reduce the tendency to form hollow current profiles, we got the
RF going throughout the shot. Then we went back to shot 3. This ran, as
also did the fiducial (35). We then got a shot with the EF1s crowbarred early
that made it, but the final shot which attempted to limit the current to
.5MA did not.

Conditioning or some other behaviour is now different. We are getting
hollow temperature profiles, a tendency for runaways and slower Ip rises.
The effect is to cause the shape to be more unstable in the first
200ms. It seems that this is combatted to some extent by early gas but
a consistent solution is not to hand.

Achieved: Early RF coupling. Hollow Te profiles. But no obvious signs
of any good confinement.

Scorecard
_________
Shot,Duration(s),Ipmax(MA) Shot,Duration(s),Ipmax
1 0.000 0.029 2 0.168 0.659
3 1.543 0.833 4 0.000 0.026
5 0.172 0.582 6 0.154 0.566
7 0.179 0.590 8 0.161 0.554
9 0.151 0.528 10 0.141 0.543
11 0.000 0.010 12 0.130 0.458
13 0.136 0.522 14 0.124 0.473
15 0.120 0.468 16 0.130 0.460
17 0.129 0.427 18 0.182 0.582
19 0.142 0.502 20 0.130 0.419
21 0.146 0.507 22 0.000 0.031
23 0.000 0.037 24 0.178 0.597
25 0.179 0.595 26 0.183 0.582
27 0.178 0.559 28 0.184 0.584
29 1.160 0.492 30 1.193 0.497
31 1.467 0.510 32 1.460 0.515
33 1.480 0.543 34 1.528 0.830
35 1.539 0.830 36 1.530 0.833
37 1.530 0.833 38 0.288 0.621

38 shots. 33 plasmas. 4 fizzles. 1 duds.
Fizzle = gt 17 lt 50kA.

Details
_______

Start from 951215040
Gas:
A-side plenum filled to 20psi with D2.
B-top plenum 5psi D2
B-side-lower 4psi Ar
Note: PLC control of TF.
Tweaked B_r offset to .0065 (was .0055).
Loaded wire from seg 2 wire 4 CLEARIN to seg1 wire 4. Gain 3 from 40ms to
0.08ms then 6.
RCUR: Called fluxihh in the first predictor. Its version is slightly later
there seem to be some differences. Only at -10 to -3 s.

1 Fiz Br seems low.

Br to 7.5 offset.
2 Pla Vertical thrash leads to disruption at 160ms. Slow instability
caused by extra elongation while the position is still rather far
in.

RCUR seg 1 new version. offset 10000 till 40ms, then 5000. Notched
the derivative gain off 38ms to 42ms. Seg2 offset to 5000.
Programmed clearin to ramp from (0s,-.02) to (150ms,0.).
2 Pla Ran the duration. Density rises fast and shuts off. A few hards.
Signs of vertical instability 130ms, 180ms and 300ms.
Diverts at 160ms (.6MA) ELM free H-mode at .9-10.s, with RF.

Fill puff to -515 to -493 (increase by 3ms).
Lowered gas 3 puff V to 15 from 30 during 1st 100ms.
EF3 V given a 100V rampdown and back minimum at 35ms.
3 Fiz Got 2.4e-5 fill. (c.f. 1.9) fizzled at 30kA, 14ms.

Drop gas back to -494. Lower EF3 V to 2000 at 20ms.
4 Pla Four oscillations of vertical instability during 80 to 160ms.
There seems to be crosstalk between the R and Z oscillations.

Lowered RCUR P till 40ms, to try and get rid of RCUR instabilities.
5 Pla Vertical instability terminates at .15s. Hard xray warning .04R.
Stability in segment 1 looks better. Plasma seems to get hit at the
segment switch.

Put gas puff to 100V from 0 to .01s.
Clearin to -.02 at .1s in segment 2. RCUR in segment 2 to .653 at
0.1s to match seg 1. This should fix these discontiuities
6 Pla Vertical instability during .1 to .15s then lost.

Drew RCUR to .66m (from .653) at .1s, ramping out in segment 1 from
0.6s. Reduced Gas 3 early peak. Introduced a gas 4 pulse -20ms to 0ms.

Lost all my notes from shot 6 on.
Basically tried a lot of things including early EF1 crowbars, which work,
Lowering fast zcur P, which looked worse. Removed clearin gain, hardly any
change.
Nothing succeeded in preventing the vertical instability.
Check Wolfe's notes for details.

22, 23 fiducials thrown away by no EF1 commutation.

24 Pla Fiducal suffers from the vertical instability.

Reload.
25 Pla Same

Set clearin to -.02 till 200ms.
26 Pla Rather the same.

Fix early gas puff to give one chop.
27 Pla Same thing. Vertical Instability.

Wolfe did a cold start things look all right. However, the plasma
looks really bad, as if the control is messed up.
Add gas puff set to 25 during 10-80ms.
28 Pla

Loaded 951207015. A low elongation shot from the kappa scan.
Br is at 7mT.
29 Pla Long shot. Xray warning. ECE looks really ugly, reported as hollow
current profiles for about .5s.

Repeat.
30 Pla Long again. ECE seems more sensible, except in the rise.

Raise nl04 to 6.e19.
31 Pla Hollow T_e till about 300ms. Apparently radiative effect.
Got the higher density. 2pi drops to 160kW once the hollowness
disappears, from about 500kW earlier.

Asked for early RF.
32 Pla Got 1MW through most of shot. Te0 hotter early.
Density jumps up to demand only when the sawteeth appear.

Added a gas 4 pulse at -30 to 0ms. Set nl04 to 8e19.
33 Pla Getting the RF on before the sawteeth start at .2s.

Load shot 3. Br to 7mT offset.
34 Pla Ran the duration.

Reload shot 24 for the fiducial.
35 Pla Ran the duration at last.

Reload 34. Add an early density point to keep the gas on.
36 Pla Fine. Seemed to get rid of the current S. Got 1.1MW from .11s

Tweaked up nl04 some more.
EF1 crowbar to .08s.
37 Pla

Drew Ip to 500kA.
38

Session Leader Comments
Dec 21 1995 07:47:58:360AMSteve WolfeRun Plan for Thurs 12/21/95

MP 126 Fast Current Ramp
MP 125A ICRF Reverse Shear Mode
SL wolfe
PO Hutch

Start from a fiducial shot setup
Tune up the starting equilibrium to
a) Elongate and divert as early as possible
CLEARIN on wire 4 in Seg 1
Crowbar EF1's earlier
b) Move out to match antenna as early as possible
Low-level RF to check loading
Turn on High power RF during early ramp up
Vary early density programming
Monitor Moly brightness, RF loading, runaways

For all of the above steps,monitor Moly levels,heating, Te(r) profiles,
sawtooth onset, any signs of improved confinement.

If there are any signs of improved confinement, or of reverse shear,
and if there is time, try firing Li pellets for (probably destructive) Bz
measurements.

Dec 21 1995 08:55:34:990AM951221001Steve WolfeLoad from 951215040, adjust Br to 0.0065
Put clearin on wire 4 in segment 1, turned on from .04 g=3, .08 g=6
Re-do the RCUR wire in segment 1 to start with fluxihh case; note that
the fluxihh algorithm previously loaded was dated 1993, the new one
is from 1995. Leave the first line at -10sec for now, so it should not
do anything.

Fizzle. Br looks negative now!

Dec 21 1995 09:07:07:970AM951221002Steve WolfeRaise Br to .0075
Everything else as for shot 1:
Put clearin on wire 4 in segment 1, turned on from .04 g=3, .08 g=6
Re-do the RCUR wire in segment 1 to start with fluxihh case; note that
the fluxihh algorithm previously loaded was dated 1993, the new one
is from 1995. Leave the first line at -10sec for now, so it should not
do anything.

Short shot .16 sec, not a fizzle. Some hards at the dump.
Clearin may be doing it in. It looks much more elongaterd early.

Dec 21 1995 09:33:10:050AM951221003Steve WolfeShot 951221003

Call the new RCUR in segment 1, with initial offset of 10000.,
change to 5000 at 40msec. Change offset in seg 2 to 5000,
and recalc the predictor there too. Put a drop in the D-gain around
40msec to avoid seeing the big change in the predictor.
Change clearin program to be negative and ramp in segment 1.

Note: The Michaelson ECE is running, the GPC seems to be off, probably
the preamps.

Plasma - up and down. H-mode at .9sec or so.
No signal on Moly monitor.
Doesn't sawtooth until 290msec

Dec 21 1995 09:35:30:170AM951221003Steve WolfeShot 951221003

Call the new RCUR in segment 1, with initial offset of 10000.,
change to 5000 at 40msec. Change offset in seg 2 to 5000,
and recalc the predictor there too. Put a drop in the D-gain around
40msec to avoid seeing the big change in the predictor.
Change clearin program to be negative and ramp in segment 1.

Note: The Michaelson ECE is running, the GPC seems to be off, probably
the preamps.

Plasma - up and down. H-mode at .9sec or so.
No signal on Moly monitor.
Doesn't sawtooth until 290msec
Right gap goes to zero at 80msec and again at 120

Dec 21 1995 09:54:51:170AM951221004Steve WolfeShot 951221004

Raise fill pre-puff
Reduce gas prog in seg 1
Adjust V program on EF3 to try to prevent RCUR thrash

Fizzle. Fill got to 2.4e-5, maybe too much. CII level to .01mW/cm2/ster

Dec 21 1995 10:13:15:600AM951221005Steve WolfeShot 951221005

Reduce fill pre-puff
As on shot 4:
Reduce gas prog in seg 1
Adjust V program on EF3 some more to try to prevent RCUR thrash

Lost it early - vertical instability.
Note: E-port tuner is OTL, probably hardware in the cell. D-port tune is
good. RF still at low power early.

Dec 21 1995 10:23:53:370AM951221006Steve WolfeShot 951221006

Reduce RCUR P-gain from 9.5 to 5 until 40msec
short + xrays
Much less thrash in RCUR in seg 1.

Dec 21 1995 10:53:19:970AM951221007Steve WolfeShot 951221007

Change clearin in seg 2 to match seg 1.
Take out small discontinuity on RCUR at segment switch
Put gas puff at 100V from .01sec

Still short. Still some hards.
Still vertically unstable.

Dec 21 1995 11:04:37:190AM951221008Steve WolfeShot 951221008

MOve RCUR out by 7mm (both segs)
Tweak aside puff, add a second puff from B-top

Similar, vertical instability.

Dec 21 1995 11:16:45:280AM951221009Steve WolfeShot 951221009

Get rid of P=8 in fast ZCUR seg2 (set P=4 from 110msec)
Move RCUR back in by 3mm

No help. Shorter.

Dec 21 1995 11:31:00:610AM951221010Steve WolfeShot 951221010

Put ZCUR P gain back to 8
Move EF1 crowbar from .11 to .08

Died earlier, 138msec. It didn't seem to move with the EF1
crowbar though.

Dec 21 1995 11:40:44:850AM951221011Steve WolfeShot 951221011

Back off on CLEARIN to -0.02 at 100msec

Magnet resistance fault- no OH1,OH2,EF1,EF3,EF4,TF
No plasma

Dec 21 1995 11:53:16:780AM951221012Steve WolfeShot 951221012

Repeat
Back off on CLEARIN to -0.02 at 100msec

Very similar to 10.
CLEARIN error actually makes it to zero before it dies.

Dec 21 1995 12:01:57:730PM951221013Steve WolfeShot 951221013

Crowbar EF1s at 0.06
CLEARIN back down to -0.03 at .1sec

Still short and vertically unstable.

Dec 21 1995 12:13:36:470PM951221014Steve WolfeShot 951221014

Put ZCUR3 P=4 instead of 8 again.

DIsrupted earlier.

Dec 21 1995 12:25:37:180PM951221015Steve WolfeShot 951221015

Halve the ZXL gain and draw it to zero (was +0.01)
Put P=8 back on ZCUR3 (didn't help to reduce it)

This one went unstable in segment 1 (before any changes)

Dec 21 1995 12:40:22:290PM951221016Steve WolfeShot 951221016

Turn off CLEARIN gain in segment 1 (drop back ten yards and prepare to
punt...)

Less elongated, same result (early disruption)

Dec 21 1995 12:45:07:300PM951221017Steve WolfeShot 951221017

Delay ZXL and RXL gain till .15sec

Unstable before the segment switch.

Dec 21 1995 12:57:26:510PM951221018Steve WolfeShot 951221018

Reload shot 3 and put EF1 crowbar back to 0.11
See if this one will still run.

Still disrupts early but made it to .18

Dec 21 1995 01:08:21:160PM951221019Steve WolfeShot 951221019

Go back to shot 17 and move EF1 crowbar to .08

Disrupts at 150. Still hards. Maybe if we fix the hards the plasma will
be better

Dec 21 1995 01:17:58:230PM951221020Steve WolfeShot 951221020

Make EF4 20a more positive to 1130.
Put ZXL gain back at 1, put RXL gain back as well.

Still disrupts, still have xrays.

Dec 21 1995 01:26:46:000PM951221021Steve WolfeShot 951221021

Change EF4 in the opposite direction (negatve by 40A to 1170)
Drop Br by .5mT to .007

Same damn thing. Gets to 150msec. Still have xrays.
Some hesitation on current rise.

Dec 21 1995 01:44:43:690PM951221022Steve WolfeShot 951221022

Fiducial : Load 951215040, and set Br to .007
EF1 crowbar back to .110
JT is instructing the EO's on a new program to set up diags and RF

Fizzle. Br doesn't look bad, fill is 1.8e-5. Why didn't it go????

Dec 21 1995 01:59:39:640PM951221023Steve WolfeShot 951221023

Repeat Fiducial : Raise fill puff by 2msec

Still fizzles?? The EF1's weren't commutating. Joe had changed the
open time instead of the crowbar!

Dec 21 1995 02:17:06:980PM951221024Steve WolfeShot 951221024

Repeat Fiducial :

Short disrupts at 180, vertically unstable !!

Dec 21 1995 02:24:50:670PM951221025Steve WolfeShot 951221025

Repeat Fiducial :
No changes from last shot

Same thing.

Dec 21 1995 02:31:24:430PM951221026Steve WolfeShot 951221026

Reduce clearin at start of seg 2

Still disrupting at 180msec. Something is very wrong.

Dec 21 1995 02:40:56:110PM951221027Steve WolfeShot 951221027

Adjust early gas

No help. Same thing.
There was no coldstart this morning, so I'm going to do one beforre the
next shot.

Dec 21 1995 02:54:04:590PM951221028Steve WolfeShot 951221028

Did a coldstart.
Ian is going to increase the gas between 10 and 80msec

Still disrupts with a vertical instability at 180 msec

Dec 21 1995 03:12:57:230PM951221029Steve WolfeShot 951221029

Load a shot from the 951207015 (low elongation limiter run)

Ran to 1.2sec
Still getting hard xrays.
Still unstable early, but makes it through it.

Dec 21 1995 03:24:05:190PM951221030Steve WolfeShot 951221030

Repeat to see if it improves.

Similar. EF1U is killing the shot.
This one the ECE looks more normal,

Dec 21 1995 03:46:40:250PM951221031Steve WolfeShot 951221031

Raise density to 0.6e20
Plasma - all the way through

This one has hollow te profiles to .35 sec, sawteeth after .45
Note tthat 29 was hollow till .5 or so.
EFIT is giing unphys. pressure errors during hollow te times

Dec 21 1995 03:56:24:780PM951221032Steve WolfeShot 951221032

Repeat with RF on at 110msec

Plasma ran- rf ran, te is hotter (around 2kev) early, sawteeth
don't start until 400msec.
Temperature peaks up. Density is low until sawteeth start.

Dec 21 1995 04:11:02:120PM951221033Steve WolfeShot 951221033

Try to get density higher earlier, raise to 8e19.

Starts sawtoothing at 0.23.
Lots of high freq. hash on halpha coincident wit sawteeth.

Dec 21 1995 04:11:23:740PM951221033Steve WolfeShot 951221033

Try to get density higher earlier, raise to 8e19.

Starts sawtoothing at 0.23.
Lots of high freq. hash on halpha coincident wit sawteeth.
Hardly any hards.

Dec 21 1995 04:24:35:310PM951221034Steve WolfeShot 951221034

reload shot 3 and leave RF where it is.

Plasma - up and down
RF tripped out but stayed on until about .4
Started sawtoothing around 200msec and bursty

Dec 21 1995 04:32:49:620PM951221035Steve WolfeShot 951221035

Reload 24 for fiducial..

Finally a fiducial...

Dec 21 1995 04:45:41:720PM951221036Steve WolfeShot 951221036

Reload 24 and fill in the density dip.

Plasma - up & down
Less of a dip, but still some.
H-modes at .7 and .95
RF on from .1 sec at 1.1sec
No sawteeth until 220msec

Dec 21 1995 06:17:50:500PM951221036Steve WolfeShot 951221036

Reload 34 and fill in the density dip.

Plasma - up & down
Less of a dip, but still some.
H-modes at .7 and .95
RF on from .1 sec at 1.1sec
No sawteeth until 220msec

Dec 21 1995 04:59:57:030PM951221037Steve WolfeShot 951221037

Try to fill in the density even more.
Crowbar EF1 at 0.080 s again.

Plasma - up & down
RF stayed on
sawteeth starting at 220
Te gets to 3.8 keV before sawteeth.
Te was hollow before RF.

Dec 21 1995 05:13:05:870PM951221038Steve WolfeShot 951221038 - last shot of the year!

Flattop the current at 500kA. Same current rise as 37

Short disruption. Lasted to about 280msec
Vertical instability.
Gets to 3.5keV before first tooth, and is hollow before the RF.

Physics Operator Comments

Engineering Operator Comments
ShotTimeTypeStatusComment
108:48:50:390AMPlasmaOk
208:59:54:180AMPlasmaBadoh2u comm fault
309:19:29:430AMPlasmaOk
409:48:03:040AMPlasmaOk
509:58:38:480AMPlasmaOk
610:15:37:960AMPlasmaOk
710:45:18:370AMPlasmaOk
811:00:59:940AMPlasmaOk
911:12:33:930AMPlasmaOk
1011:24:01:290AMPlasmaOk
1111:37:49:990AMPlasmaBadmag resist fault in pulse
1211:45:02:620AMPlasmaOk
1311:55:54:550AMPlasmaOk
1412:09:23:870PMPlasmaOk
1512:20:41:950PMPlasmaOk
1612:30:39:420PMPlasmaOk
1712:42:32:810PMPlasmaOk
1812:50:13:860PMPlasmaOk
1901:03:22:470PMPlasmaOk
2001:12:43:660PMPlasmaOk
2101:22:10:400PMPlasmaOk
2201:37:14:580PMPlasmaOk
2301:46:58:850PMPlasmaOk
2401:59:39:190PMPlasmaOk
2502:17:36:010PMPlasmaOk
2602:26:22:950PMPlasmaOk
2702:36:34:350PMPlasmaOk
2802:50:10:060PMPlasmaOk
2902:59:55:670PMPlasmaOkOH2U&L Comm fault; EF1 One scr not conducting; Oh1 comm fault
3003:13:33:590PMPlasmaBadef1u one scr not conducting
3103:31:36:880PMPlasmaOkno faults.
3203:45:33:000PMPlasmaOk
3304:00:53:140PMPlasmaOk
3404:16:30:930PMPlasmaOk
3504:28:00:110PMPlasmaOk
3604:37:53:080PMPlasmaOk
3704:48:51:360PMPlasmaOk
3805:02:55:380PMPlasmaOk