Alcator C-Mod Run 960104 Information

Back to runs

Miniproposals
Miniproposal:113
Date Filed: 4/13/1995
Title:Impurity Puffing to Induce the Detached Divertor Condition in
First Author:Steve Golovato
Session Leader:Gary McCracken (shots 1-16)

Operators
Session leader(s):Gary McCracken
Physics operator(s):Robert Granetz
Engineering operator(s):Vinny Bertolino

Engineering Operator Run Comment
first run year, pre bor

Session Leader Plans

Physics Operators Plans

Session Leader Summaries

Physics Operator Summaries
Entered: Jul 7 2004 04:36:55:723PM
Author: To Be Determined
Physics Operator's summary for run 960104

MP 113-- Boronization run, but prior to any boronization (to get a good
baseline)

SL: G. McCracken
PO: R. Granetz
EO: V. Bertolino

Today's run plan:
(0) Check out EF1 supplies (new transformer, other changes)
(1) 5 fiducial shots
(2) 6-shot density scan, alternating with fiducial shots (12 shots total),
at high RF power
(3) 2 RF power ramp shots (0.5-3.0 MW), alternating with fiducials (4
shots total),
(4) PEP mode with D or Li pellets (time permitting)

Summary: The entire day was spent debugging the upgraded EF1 supplies. We'll
have to continue this mini-proposal tomorrow.

Scorecard: 0 plasmas
0 fizzles
0 duds
16 tests (EF1's)
----------
16 total

Run setup: ECDC in helium before run.
Start with fiducial shot 951215040.
Deuterium in K-side at 20 psi (used to be A-side), enabled for hybrid.
Deuterium in B-top at 5 psi (puff pre-fill), enabled for hybrid.
Argon in B-side-lower at 4-5 psi, but not enabled.
RF ready to go on first shot.
LPI may be used late in the run.
Enable the ECE, VUV, Moly monitor, PCX, and TCX valves

Detailed shot log:

Shot 01 -- EF1 test. Blown fuses. We'll be down for an hour or more to fix
the problems.

Shot 02 -- Open-circuit EF1 test.

Shot 03 -- Open-circuit EF1 test.

Shot 04 -- Open-circuit EF1 test.

Shot 05 -- Open-circuit EF1 test.

Shot 06 -- EF1U test. Got bus current.

Shot 07 -- EF1U test, opposite polarity. Good.

Shot 08 -- EF1U test. Good.

Shot 09 -- EF1U test. Breaker pulled early.

Shot 10 -- EF1U test, 1 kA.

Shot 11 -- EF1U test, 1 kA. Good.

Shot 12 -- EF1L test, 1 kA, opposite polarity. Good.

Shot 13 -- EF1L test

Shot 14 -- EF1L test

Shot 15 -- EF1L & U test. Good. 1 kA

Shot 16 -- EF1L & U test. Good. 4 kA.

End of run.

Session Leader Comments
Jan 4 1996 10:07:34:890AMGary McCrackenMP113: Boronization of Alcator C-Mod

The objective of this run is to a have a series of fiducial
shots prior to the boronization. This run will then be repeated
immediately after boronization. The run plan will follow the shot
sequence plan in the MP.
5 standard fiducial shots
6 shot density scan
an RF density scan at nl04=1e20

Jan 4 1996 05:08:53:250PMGary McCrackenSummary
Power supply problems all day. See PO log for details.
Problems mostly sorted out by the end of the day, 14 shots.
We hope to do the planned program tomorrow

Jan 4 1996 10:09:22:510AM960104001Gary McCrackenPower supply test shot.
Problem with the transformer. There will be a delay of about 2 hours.

Physics Operator Comments
Jan 4 1996 10:04:47:360AM960104001Robert GranetzPhysics Operator's summary for run 960104

MP 113-- Boronization run, but prior to any boronization (to get a good
baseline)

SL: G. McCracken
PO: R. Granetz
EO: V. Bertolino

Today's run plan:
(0) Check out EF1 supplies (new transformer, other changes)
(1) 5 fiducial shots
(2) 6-shot density scan, alternating with fiducial shots (12 shots total),
at high RF power
(3) 2 RF power ramp shots (0.5-3.0 MW), alternating with fiducials (4
shots total),
(4) PEP mode with D or Li pellets (time permitting)

Jan 4 1996 10:05:28:010AM960104001Robert GranetzRun setup: ECDC in helium before run.
Start with fiducial shot 951215040.
Deuterium in K-side at 20 psi (used to be A-side), enabled for hybrid.
Deuterium in B-top at 5 psi (puff pre-fill), enabled for hybrid.
Argon in B-side-lower at 4-5 psi, but not enabled.
RF ready to go on first shot.
LPI may be used late in the run.
Enable the ECE, VUV, Moly monitor, PCX, and TCX valves

Jan 4 1996 10:05:42:060AM960104001Robert GranetzShot 01 -- EF1 test. Blown fuses. We'll be down for an hour or more to fix
the problems.

Jan 4 1996 01:41:48:990PM960104002Robert GranetzShot 02 -- Open-circuit EF1 test.

Jan 4 1996 01:42:07:430PM960104003Robert GranetzShot 03 -- Open-circuit EF1 test.

Jan 4 1996 02:50:37:330PM960104004Robert GranetzShot 04 -- Open-circuit EF1 test.

Jan 4 1996 02:50:50:530PM960104005Robert GranetzShot 05 -- Open-circuit EF1 test.

Jan 4 1996 02:51:31:300PM960104006Robert GranetzShot 06 -- EF1U test. Got bus current.

Jan 4 1996 02:51:44:660PM960104007Robert GranetzShot 07 -- EF1U test, opposite polarity. Good.

Jan 4 1996 02:51:55:710PM960104008Robert GranetzShot 08 -- EF1U test. Good.

Jan 4 1996 02:52:38:430PM960104009Robert GranetzShot 09 -- EF1U test, both polarities. Breaker pulled early.

Jan 4 1996 03:33:34:650PM960104010Robert GranetzShot 10 -- EF1U test, 1 kA.

Jan 4 1996 04:09:00:140PM960104011Robert GranetzShot 11 -- EF1U test, 1 kA. Good.

Jan 4 1996 04:09:12:040PM960104012Robert GranetzShot 12 -- EF1L test, 1 kA, opposite polarity. Good.

Jan 4 1996 05:10:17:610PM960104013Robert GranetzShot 13 -- EF1L test

Jan 4 1996 05:10:54:300PM960104014Robert GranetzShot 14 -- EF1L test

Jan 4 1996 05:11:30:450PM960104015Robert GranetzShot 15 -- EF1L & U test. Good. 1 kA

Jan 4 1996 05:11:42:010PM960104016Robert GranetzShot 16 -- EF1L & U test. Good. 4 kA.

Engineering Operator Comments
ShotTimeTypeStatusComment
109:20:06:930AMTestBadef1 test IOC c-bar fired
201:18:54:270PMTestOk
301:39:01:950PMTestOk
401:48:48:920PMTestOk
502:03:53:590PMTestOk
602:20:42:390PMTestOk
702:36:53:490PMTestOk
802:45:26:690PMTestOk
902:49:33:180PMTestOk
1003:22:18:600PMTestOk
1103:50:24:330PMTestOk
1203:56:42:990PMTestOk
1304:50:51:590PMTestOk
1404:55:21:190PMTestOk
1505:00:38:850PMTestOk
1605:04:46:410PMTestOk