| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Gary McCracken |
| Physics operator(s): | John Goetz |
| Engineering operator(s): | Vinny Bertolino |
| Engineering Operator Run Comment |
| MP 133 |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:14:913PM |
| Author: To Be Determined |
| Run Summary 960112: MP 113 Boronization of Alcator C_Mod S/L G McCracken P/O J Goetz E/O V Bertolino MP 113 Boronization of Alcator C_Mod Boronization of C-Mod was carried out on Jan 7, 9,10 using ECDC to decompose the borane gas in the vessel. The total number of boron atoms injected was ~ 2e23, corresponding to a layer 100 nm thick if it were uniformly distributed. Observation through windows in the vessel indicated that it had gone about 90 degrees toroidally each way around the vessel from the injection port. The object of this run was to repeat the 5 fiducial shots similar to the pre-boronization run 950105 and then do a density and an RF power scan. These objectives were all achieved although there was difficulty getting to high density and the power scan was limited to a maximum of 1.4 MW. The boronization seems to have reduced the Mo in ohmic shots to background level. Observations with the McPherson indicate that the Mo monitor is seeing only background. Distinctive Mo peaks are there during RF but they are down almost an order of magnitude , from a brightness of ~8e15 photons/ster/cm2/s before boronization to a value of 1.5e15 photons/ster/cm2/s after boronization. The Mo level continued to fall slightly during the run to ~8e14 photons/ster/cm2/s. A strong boron II line at 345.1 nm was seen on the Chromex spectrometer and did not change brightness significantly throughout the run. The spatial distribution of the boron (BII, 411 nm) seemed peaked at the inner nose like all the other impurities we have looked at. The CII monitor was down but by less than a factor 2. Joe Snipes reports that the O I monitor is down almost a factor of 2. The fraction of the total power radiated has fallen significantly, to less than 30%. We completed 8 fiducial shots (shots 003 to 009,23,35,37) and a density scan from nl04=5e19 to1.9e20 (shots 011 to 033). We had difficulty coupling the RF to the plasma both at low density and at high density but eventually achieved reasonable conditions. Over most of the density range we got very good H-modes, the quality decreasing as we went to higher density . It was found hard to couple the RF power at high density. We had H factors up to 1.5 the highest yet achieved with RF in C-Mod. The value went briefly as high as 1.8 at the start of heating However at 5.5e19 with 1MW ICRH there was no H-mode, establishing the lower limit of the H-mode. At slightly higher density good H-modes were obtained. The shots 34 thru 37 give us a rather good RF power scan, 0.0, 0.3, 0.8 1.0 and 1.4 MW. The power was constant from 0.7 to 1.0 s establishing steady state conditions.This may provide some interesting scaling of edge parameters . Brian reported that the surface sample removed from A-port after boronization had an insulating coating characteristic of boron. This is consistent with changes of behaviour of the Langmuir probes. Much lower noise levels were observed on the scanning probes during ICRH. Shot summary: 001 Ohmic heating test shot 002 First attempt at fiducial shot. Good shot but the density was low throughout the shot. nlo4 only gets up to 0.9e20 at 0.9 s. The RF and Mo monitor were not on. The CII (514.5 nm) was down by a factor of 2 or 3 from the pre-boronization shots in 950105. 003 First fiducial nl04=1e20 at 0.6 s. When the RF came on we had an H-mode and the density rose to 1.5e20. The CII level is about the same as the previous shot. However the Mo monitor is much lower than preboronization. The brightness is ~1.5e15 during RF. Steve Golovato reports an H factor of 1.5 004 : Second fiducial, similar to 003. When the RF came on it went into H-mode immediately and the density rose to 1.7e20. The CII is now increasing slightly when the RF comes on. The Mo monitor brightness increased during the RF pulse to 1.4e15. Chromex shows strong BII line at 345.1 nm and a weaker line at 332.3. It comes up early in the shot and peaks at about 0.5 s 005 fizzle 006 Third fiducial. Similar density trace to shot 4. Mo still low but there was an injection at 0.92 s. H-mode at 0.77 s. Total radiated power Prad bolo is low at ~300 kW during ohmic phase, 007 Fizzle 008 Fourth fiducial.. Similar to shot 006. Mo brightness going down further. H-factor going up. It was 1.8 in shot 006 009 Fifth fiducial. Again a similar to shot 006. 010 Fizzle Start of density scan 011 Good shot. nl04= 1.15e20 ; Mo 0.97e15 during RF, down a little, possibly because the density is up. H factor down to 1.5 CII up to 0.026 012 Fizzle 013 Fizzle 014 Good shot. nlo4=1.15e20, similar to shot 011. 015 Fizzle 016 Good shot. Density increased to 1.47 at 0.8 s. No RF ; wasn't tuned for higher density. Very good detachment at 0.62 s. Threshold density nl04 was 1.26e20 which is a little higher than pre boronization. Te at target goes down to 1.5 eV 017 Fizzle 018 Good shot, nlo4=1.5e20. but no RF; like shot 016 019 Fizzle 020 Fizzle 021 Good shot but no RF. Density =1.73 at 0.9 s. Still detaching early with very low target temperatures ~ 2 eV. Try to get some RF on the next shot. 022 Fizzle. 023 Fiducial shot ; Good shot but RF power a little low. Obtained a good H-mode , very similar to shots 8 and 9. Mo monitor and Prad both a little lower than earlier. Recovered the good H factor again. It increases to 1.8 briefly and then falls monotonically. 024 Fizzle 025 Good shot with RF, but power a little low. nl04=1.0e20. H-mode 026 Good shot with RF, power= 1.1 MW from 0.75 s to 1.0 s. nl04= 0.9e20. H-mode looks good, although the Halpha signal looks funny. Target tempeatures are getting quite high . Up to ~40 eV at the separatrix on probe 2. 1.5 MW getting into the SOL 027 Good shot with RF, power 1.1 MW from 0.75 s to 1.0 s. nl04= 0.8e20 increasing to 1.5 during H-mode. H-mode looks good, starting at 0.75 s and lasting all the RF pulse. Target temperatures are again high. 028 Fizzle 029 Fizzle 030 Good shot. nlo4 =0.6e20. RF initially 1.5 MW at 0.7 s but it tripped out at 0.78 s. No H mode Try again at 0.6e20 031 Good shot. nlo4 =0.67e20. Still have not got RF to stay on continuously. However when it does come on we get brief H-modes 032 Good shot. nlo4 =0.67e20. RF =1 MW from 0.7 to 1.0 s, but there were 2 interrupts which spoiled the H modes. Mo monitor went up 1e15 during RF 033 Good shot. nl04=0.55e20. 1 MW RF power steady from 0.7 to 1.0 s. NO H MODE. We seem to be below the density required for H modes. Mo level stays low. 034 Good shot. nl04=1e20 Reduced RF power to 0.31 MW . H-mode starts at 0.82 s and remains to the end of the RF pulse even though the RF power falls to 0.25 MW. Mo increases to 0.75e15 035 Good shot. nl04=1e20 RF power 1 MW from 0.7 to 1.0s. H-mode starts at 0.73 s and remains to the end of the RF pulse. Very good steady state conditions with lower Mo than in earlier fiducial shots and total radiation being down to ~28%. 036 Good shot. RF power is 1.44 MW . Radiated power down to 26%. Mo level still below 1e15 This completes the RF power scan. 037 Fiducial shot. For this shot the Mo monitor gives a Mo level during the RF significantly lower (~0.8e15) than in the earlier fiducial shots, #003-009, (1.2 to 1.6e15) and much lower than before boronization (6 to 8e15) 038 Fizzle 039 Attempt a PEP discharge using a Li pellet. Good shot but no pellet. Constant 1 MW RF power from 0.75 to 1.0 s. Low Mo and low Prad. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:55:753PM |
| Author: To Be Determined |
| Physics operator summary for 960112 EO: Bertolino PO: Goetz SL: McCracken Run 960112 was in support of Mini-Proposal #133 - Boronization of Alcator C-Mod. The goal of this run is to implement ECDC boronization of C-Mod and make a preliminary evaluation of its utility with respect to wall conditioning, impurity influx, recycling, divertor dynamics and energy confinement enhancement in H-mode and PEP-mode. Program for this run: - Learn how to run with boronized walls - Run a set of fiducials (5) - Density scan - ion cyclotron range of frequencies power scan - PEP studies with lithium pellets A very successful and exciting run. See the session leader's summary for a detailed report on this program. Some things discovered today: 1) Startup was quite iffy today. An alternating pattern of fizzles and plasmas was the outcome for most of the day. Only late in the run, shots 030 - 037, was a string of plasmas put together. Most fizzles were very weak, less than 20kA. There were two strong fizzles, ~ 40kA, and they preceded the string. 2) The cause of the fizzles is not readily apparent. The Br offset was changed in the range of 6.4 to 7.5mT. IC_EF4 was changed by 20A and V_OH1 was increased by 40V to change the ramp of Bz. The prefill puff duration was increased and then decreased, with a final value of 14msec. None of these changes seemed to correlate with the reduction in fizzle frequency, except for the OH1 voltage change. The prefill puff was difficult to diagnose as the ratiomatic data were not being stored on most shots due to CAMAC errors. 3) A working theory of fizzles based on the partial pressure of mass 32 (diborane) was validated for most of the day, but eventually was tossed aside. The fizzle/plasma pattern may just be due to working with boronized walls. 4) Density control was difficult today. The walls, or whatever reservoir, seemed to have much more control over the density than the gas valve. A second valve was necessary to reach the highest density requested. 5) The machine ran very well today when it ran. All plasmas with NL04 less than or equal to 1e20 ramped down to less than 50kA. Engineering, computing, and diagnostics today: Engineering tests were performed on shot 001 to check the OH coax resistances. Some CAMAC errors today, mostly on GKA5:. Scorecard: 39 shots = 24 plasmas + 14 fizzles + 1 test Shot summary for Run 960112: Load 960105010 - no changes coldstart hybrid - all matrices respond Shot change result ____ _____ ______ 1 eng. test shot for OH resistances o.k. 2 see above plasma - all the way down - density very low 3 load reasonable waveform into plasma - all the way down - density PG3 better 4 NL04 to max @ 0.5sec plasma - all the way down - H-mode @ .78 5 no changes fizzle - weak one - null looks fine 6 no changes plasma - all the way down - good current rise 7 no changes fizzle - weak - null o.k. - Br too small 8 Br_0 offset = .0072 plasma - all the way down - Mo at crossover 9 no changes plasma - all the way down - hesitation 10 NL04=1.3e20; more PG3 volts fizzle - hit something 11 Br_0 offset = .0075 plasma - all the way down; NL04=1.15e20 12 more PG3 volts; ZXL=-.02 fizzle (weak); not enough Bz early? 13 IC_EF4=-1140A; add 2msec to fizzle; too much Br? prefill 14 remove 4msec from prefill puff; plasma - all the way down; good current Br_0 offset = .007 rise; NL04=1.15e20 15 more PG3 volts; NL04=1.6e20 fizzle; Br not positive enough 16 BR_0 offset = .0075; 2msec less plasma - disr. @ 1.34; shark fin; fill prefill puff (now 14msec) pressure=0.8e-5; NL04=1.5e20 after detach @ 0.57 17 PG2 with 20PSIA deuterium and fizzle (weak); need more Bz earlier 30V waveform 18 IC_EF4 = -1130A plasma - disr. @ 1.34; no RF; divertor detachment 19 NL04=1.9e20; PG2 = 45V fizzle - fields o.k. - fill unknown 20 no changes fizzle 21 BR_0 offset = .0069 plasma - disr. @ 1.21 - good curr rise 22 BR_0 offset = .0064; PG2 pulse fizzle - fields look fine to make sure its open 23 reload 960112008 - a fiducial plasma - all the way down; good fiducial 24 NL04=0.8e20 and less PG3 volts; fizzle - fields look o.k. BR_0 offset=.0064 and V_OH1 = 150V from .005 to .015 25 no changes plasma - all the way down; density creeping up during shot 26 PG3 = 20V plasma - all the way down; NL04 = 0.8-> 0.9e20 27 PG3=10V; NL04=0.69e20 plasma - all the way down; NL04=0.8e20 28 PG3=0V; NL04=0.55e20 fizzle (strong) 29 no changes fizzle (strong); Br too negative 30 Br_0 offset = .0069; V_OH1 = plasma - all the way down; NL04=0.6e20 170V from .005 to .015 31 no changes plasma - all the way down; NL04=0.66e20 32 no changes plasma - all the way down; ohmic H-mode NL04=0.66e20 at transition 33 disable argon puff plasma - all the way down; no RF; no H-modes; NL04=0.55e20 34 NL04=1e20 adn PG3=25V plasma - all the way down; NL04=0.9->1.0 e20; 0.3MW RF (H-mode) 35 PG3=35V plasma - all the way down; NL04=1.1e20 1.MW RF (H-mode) 36 no changes plasma - all the way down; NL04=1.1e20 1.5MW RF (H-mode) 37 setup for fiducial; PG3=30V plasma - all the way down; NL04=1.1e20 acceptable fiducial 38 enable Ar puff (12msec) and fizzle (weak) enable LPI 39 no changes plasma - disr. @ 1.19; no Li pellet |
| Session Leader Comments | |||
| Jan 12 1996 08:55:24:290AM | Gary McCracken | MP 113 Boronization of Alcator C_Mod
S/L G McCracken P/O J Goetz E/O V Bertolino The boronization has been caried out on 1/7,1/9,and 1/10 using ECDC to decompose the borane gas in the vessel. The total number of boron atoms injected was ~ 2e23, corresponding to a layer 100 nm thick if it were uniformly distributed. Observation indicated that it had gone around about 90 degrees each way from the injection port. The object of todays run is to first repeat 5 fiducial shots similar to the pre-boronization run on 1/6. Then do a density scan. | |
| Jan 12 1996 05:23:32:120PM | Gary McCracken | Summary:
Very successful run. The boronization seems to have reduced the Mo during RF by about an order of magnitude, from a brightness of 6 to 8e15 photons/ster/cm2/s to a value of 0.7 to 0.8 photons .... The fraction of the total power radiated has also fallen significantly, to less than 30%. We completed 5 fiducial shots and a density scan from nl04=5e19 to 1.9e20. At 5.5e19 with 1MW ICRH there was no H-mode, establishing the lower limit of the H-mode An RF power scan from 0 to 1.4 MW in 5 steps should provide some interesting scaling of edge parameters. The power was steady from 0.7 to 1.0 s establishing steady state conditions. In some H-mode shots we had an H factor up t0 1.5 the highest yet achieved with RF in C-Mod | |
| Jan 12 1996 08:59:50:580AM | 960112001 | Gary McCracken | Ohmic heating test shot
|
| Jan 12 1996 09:08:47:910AM | 960112002 | Gary McCracken | First attempt at fiducial shot. Good shot but the density was low
throughout the shot. nlo4 only gets up to 0.9e20 at 0.9 s. The fiducial program did not run and the RF was not on. The CII (5145) was down by a factor of 2 or 3 from the pre-boronization shots on 1/5.Te(0) was ~1300 eV , rather similar to 1/5 Try again. |
| Jan 12 1996 09:12:36:330AM | 960112002 | Gary McCracken | Mo monitor not on
|
| Jan 12 1996 09:28:30:640AM | 960112003 | Gary McCracken | Good shot. Density got up to 1e20 at 0.6 s. when the RF came on
it rose slightly and then we had an H-mode. The density rose to 1.5e20 The CII level is about the same as the previous shot. However the Mo monitor is much lower than preboronization. The brightness is~1.5e15 during RF . Also Steve Golovato reports an H factor of 1.5 |
| Jan 12 1996 09:37:24:380AM | 960112004 | Gary McCracken | Good shot. Density got up to 1e20 at 0.6 s. When the RF came on
it went into H-mode immediately and the density rose to 1.7e20. The CII is now increasing slightly when the RF comes on. The Mo monitor indicates an initial brighteness of 0.7e15 after the RF comes on but increases during the RF pulse to 1.4e15. Looks good |
| Jan 12 1996 09:50:54:260AM | 960112004 | Gary McCracken | Chromex up and running. Very strong BII line at 345.1 nm and a weaker
line at 332.3. The signal seems to be all in bin2 ie the view from the top with a little in bin 1 a-side. the time history shows that it is coming up early in the shot and peaking at about 0.5 s |
| Jan 12 1996 09:51:27:220AM | 960112005 | Gary McCracken | Unexplained fizzle
|
| Jan 12 1996 10:05:51:760AM | 960112006 | Gary McCracken | Good shot. Similar density trace to shot 4.
Mo still low but there was as injection at 0.92 s H-mode at 0.77 s. Joe Snipes reports that the OI_sig monitor is down almost a factor of 2 Total radiated power Prad bolo is low at ~300 kW during ohmic phase, increasing to nearly 600 kW during RF |
| Jan 12 1996 10:06:10:200AM | 960112007 | Gary McCracken | Fizzle
|
| Jan 12 1996 10:25:28:000AM | 960112008 | Gary McCracken | Good shot. Similar to shot 006.
Mo brightness going down further. H-factor going up. It was 1.8 in shot 006 |
| Jan 12 1996 10:34:17:950AM | 960112009 | Gary McCracken | Good shot. Again a similar to shot 006.
We have now concluded the 5 good fiducial shots. We will start a density scan next shot |
| Jan 12 1996 10:35:42:930AM | 960112010 | Gary McCracken | Good shot. Density called for 1.3e20.
Fizzle |
| Jan 12 1996 11:15:57:490AM | 960112011 | Gary McCracken | Good shot. Density called for 1.3e20.: got to 1.15e20
Mo 0.97e15 during RF, down a little, possibly because the density is up H factor down to 1.5 CII up to 0.026 |
| Jan 12 1996 11:16:36:390AM | 960112012 | Gary McCracken | Fizzle
|
| Jan 12 1996 11:16:46:450AM | 960112013 | Gary McCracken | Fizzle
|
| Jan 12 1996 11:41:09:370AM | 960112014 | Gary McCracken | Good shot. Calling for nlo4=1.3e20; got 1.15e20
similar to shot 011. Try to push density higher in the next shot |
| Jan 12 1996 11:42:29:170AM | 960112015 | Gary McCracken | Fizzle
|
| Jan 12 1996 12:12:36:270PM | 960112016 | Gary McCracken | Good shot. Density increased t0 1.47 at 0.8 s.
No RF ; wasn't tuned for higher density Very good detachment at 0.62 s Density nl04 was 1.26e20 which is a little higher than pre boronization. Te at target goes down to 1.5 eV |
| Jan 12 1996 12:23:35:110PM | 960112017 | Gary McCracken | Fizzle
|
| Jan 12 1996 12:35:40:250PM | 960112018 | Gary McCracken | Good shot, nlo4 1.5e20. but no RF; like shot 016
|
| Jan 12 1996 12:35:57:570PM | 960112019 | Gary McCracken | Fizzle
|
| Jan 12 1996 12:42:39:980PM | 960112019 | Gary McCracken | Fizzle
|
| Jan 12 1996 12:42:52:040PM | 960112020 | Gary McCracken | Fizzle
|
| Jan 12 1996 01:06:43:040PM | 960112021 | Gary McCracken | Good shot but no RF.
Density demand =1.8e20; obtained 1.73 at 0.9 s Still detaching early with very low target temperatures ~ 2 eV Try to get some RF on the next shot. |
| Jan 12 1996 01:09:58:820PM | 960112022 | Gary McCracken | Fizzle.
Seems to be a problem with these high density shots. We will go back to the fiducial shots settings for the next shot |
| Jan 12 1996 01:28:46:240PM | 960112023 | Gary McCracken | Fiducial shot settings; Ask for nl04=1.0e20
Good shot. RF power but a little low. Obtained a good H-mode , very similar to shots 8 and 9 Mo monitor and Prad both a little lower than earlier |
| Jan 12 1996 01:40:39:960PM | 960112023 | Gary McCracken | Recovered the good H factor again. It increases to 1.8 briefly
and then falls monotonically. |
| Jan 12 1996 01:41:03:050PM | 960112024 | Gary McCracken | Fizzle
|
| Jan 12 1996 01:56:35:400PM | 960112025 | Gary McCracken | Good shot with RF, but power a little low. Asked for 0.8e20 but got
1.0e20. H-mode |
| Jan 12 1996 02:12:41:800PM | 960112026 | Gary McCracken | Good shot with RF, power up to 1.1 MW from 0.75 s to 1.0 s
Asked for density 0.8e20 but got 0.9e20. H-mode looks good, although the Halpha signal looks funny. Target tempeatures are getting quite high . Up to ~40 eV at the separatrix on probe 2. 1.5 MW getting into the SOL |
| Jan 12 1996 02:26:31:340PM | 960112027 | Gary McCracken | Good shot with RF, power up to 1.1 MW from 0.75 s to 1.0 s
Density 0.8e20 increasing to 1.5 during H-mode. H-mode looks good starting at 0.75 s and lasting all the RF pulse Target temperatures are again high. |
| Jan 12 1996 02:26:52:990PM | 960112028 | Gary McCracken | Fizzle
|
| Jan 12 1996 02:29:13:830PM | 960112028 | Gary McCracken | Fizzle
|
| Jan 12 1996 02:30:33:860PM | 960112029 | Gary McCracken | Fizzle
|
| Jan 12 1996 02:54:03:260PM | 960112030 | Gary McCracken | Good shot. nlo4 =0.6e20. Got initially 1.5 MW at 0.7 s but it tripped
out at 0.78 s. No H mode Try again at 0.6e20 |
| Jan 12 1996 03:00:08:280PM | 960112031 | Gary McCracken | Good shot. nlo4 =0.67e20. Still have not got RF to stay on
continuously. However when it does come on we get brief H-modes Try again |
| Jan 12 1996 03:20:22:890PM | 960112032 | Gary McCracken | Good shot. nlo4 =0.67e20. RF on at 1 MW from 0.7 to 1.0 s, but there
were 2 interrupts which spoiled the H modes. Mo monitor went up 1e15 during RF |
| Jan 12 1996 03:26:40:390PM | 960112033 | Gary McCracken | Good shot. Lower density 1 MW RF power steady from 0.7 to 1.0 s
nl04=0.55e20. NO H MODES. So we seem to be below the density required for H modes. Mo level stays low. |
| Jan 12 1996 03:39:56:690PM | 960112034 | Gary McCracken | Good shot. Density back to 1e20 Reduced RF power to 0.31 MW .
H-mode starts at 0.82 s and remains to the end of the RF pulse even though the RF power falls to 0.25 MW. Mo increases to 0.75e15 |
| Jan 12 1996 03:52:50:540PM | 960112034 | Gary McCracken | Good shot. Density back to 1e20 RF power 1 MW from 0.7 to 1.0s.
H-mode starts at 0.73 s and remains to the end of the RF pulse. Very good steady state conditions with lower Mo than in earlier fiducial shots and total radiation being down to ~40%. |
| Jan 12 1996 03:52:58:030PM | 960112035 | Gary McCracken | Good shot. Density back to 1e20 RF power 1 MW from 0.7 to 1.0s.
H-mode starts at 0.73 s and remains to the end of the RF pulse. Very good steady state conditions with lower Mo than in earlier fiducial shots and total radiation being down to ~40%. |
| Jan 12 1996 03:55:18:160PM | 960112035 | Gary McCracken | Correction radiated power fraction is only 28%
|
| Jan 12 1996 04:15:53:820PM | 960112036 | Gary McCracken | Good shot. RF power is 1.44 MW . Radiated power down to 26%
Mo level still below 1e15 This completes the RF power scan. We will do a proper fiducial shot next time |
| Jan 12 1996 04:34:38:740PM | 960112037 | Gary McCracken | Good shot. Standard fiducial shot. The shots 34 thru 37 give us a
rather good RF power scan, 0.0, 0.3, 0.8 1.0 and 1.4 MW |
| Jan 12 1996 04:47:41:080PM | 960112037 | Gary McCracken | Good shot. Standard fiducial shot. The shots 34 thru 37 give us a
rather good RF power scan, 0.0, 0.3, 0.8 1.0 and 1.4 MW. For this shot the Mo monitor gives a Mo level during the RF significantly lower (~0.8e15) than in the earlier fiducial shots #003-009.(1.2 to 1.6e15) and much lower than before boronization (6 to 8e15) |
| Jan 12 1996 04:50:14:010PM | 960112038 | Gary McCracken | Fizzle
|
| Jan 12 1996 05:11:59:510PM | 960112039 | Gary McCracken | Attempt a PEP discharge using a Li pellet at 0.75 s with RF immediately
after the pellet injection. Good shot but no pellet. Very nice constant RF power at 1 MW from 0.75 to 1.0 s. Low Mo and low Prad. |
| Physics Operator Comments | |||
| Jan 12 1996 08:39:04:680AM | John Goetz | Run 960112 - MiniProposal # 133A: Boronization of Alcator C-Mod
The goal of this run is to implement ECDC boronization of C-Mod and make a preliminary evaluation of its utility with respect to wall conditioning, impurity influx, recycling, divertor dynamics and energy confinement enhancement in H-mode and PEP-mode. Program for this run: - Learn how to run with boronized walls - Run a set of fiducials (5) - Density scan - ion cyclotron range of frequencies power scan - PEP studies with lithium pellets | |
| Jan 12 1996 08:41:25:840AM | John Goetz | Run 960112
Engineering setup: ECDC in helium power supplies from 960105010 A_SIDE with 20PSIA of deuterium B_TOP with 5PSIA of deuterium puff pre-fill - hybrid enable A_SIDE and B_TOP Coldstart hybrid - all matrices respond Load 960105010 - no changes | |
| Jan 12 1996 08:46:08:580AM | 960112001 | John Goetz | Shot 960112001:
OH coax resistance test Results: resistances look o.k. |
| Jan 12 1996 09:13:16:430AM | 960112002 | John Goetz | Shot 960112002:
load fiducial shot 960105010 - no changes Results: plasma - all the way down density doesn't get to where its going - PG3 waveform is just a small square wave late in time many injections - presumably Mo Hard x-rays and non-thermal ECE position wiggling early in the shot |
| Jan 12 1996 09:26:22:410AM | 960112003 | John Goetz | Shot 960112003:
load reasonable waveform into PG3 enable VUV tree and turn on RF Results: plasma - all the way down RF on moly down - H factor up density waveform much better |
| Jan 12 1996 09:38:18:800AM | 960112004 | John Goetz | Shot 960112004:
ramp NL04 to max @ 0.5 sec Results: plasma - all the way down moly very low H-mode @ 0.78sec |
| Jan 12 1996 09:38:20:270AM | 960112004 | John Goetz | Shot 960112004:
ramp NL04 to max @ 0.5 sec Results: plasma - all the way down moly very low H-mode @ 0.78sec |
| Jan 12 1996 09:48:13:680AM | 960112005 | John Goetz | Shot 960112005:
no changes Results: fizzle - very weak one null looks good no Ratiomatic data - can't talk about the fill, but it had been running around 1.7e-5 |
| Jan 12 1996 09:58:50:960AM | 960112006 | John Goetz | Shot 960112006:
no changes Results: plasma - all the way down very good current rise Mo injection @ 0.91 |
| Jan 12 1996 10:10:20:500AM | 960112007 | John Goetz | Shot 960112007:
no changes Results: fizzle null looks o.k. radial field about .5mT lower on 005 and 007 than on 004 and 006 |
| Jan 12 1996 10:21:13:530AM | 960112008 | John Goetz | Shot 960112008:
Br_0 offset = .0072 Results: plasma - all the way down big Mo increase during OH1 crossover |
| Jan 12 1996 10:31:37:040AM | 960112009 | John Goetz | Shot 960112009:
no changes Results: plasma - all the way down good fiducial shot |
| Jan 12 1996 10:46:49:160AM | 960112010 | John Goetz | Shot 960112010:
NL_04 = 1.3e20 and more PG3 volts Results: fizzle - looks like it is hitting something vertical field not getting in fast enough - EF4 not getting to its programmed value; but these are opposite effects |
| Jan 12 1996 11:00:13:580AM | 960112011 | John Goetz | Shot 960112011:
Br_0 offset = .0075 Results: plasma - all the way down good current rise NL04 = 1.15e20 only |
| Jan 12 1996 11:08:28:640AM | 960112012 | John Goetz | Shot 960112012:
add more volts to PG3 to help with the density ZXL = -.02 @ 0.4sec to keep the strike point down Results: fizzle (weak) not enough Bz fast enough? |
| Jan 12 1996 11:23:04:520AM | 960112013 | John Goetz | Shot 960112013:
IC_EF4 = -1140A (was -1150A) add 2 msec to prefill puff Results: fizzle (weak) no ratiomatic data - can't diagnose the fill pressure |
| Jan 12 1996 11:35:14:740AM | 960112014 | John Goetz | Shot 960112014:
remove 4 msec to prefill puff BR_0 offset = .007 Results: plasma - all the way down good current rise no ratiomatic data again to diagnose prefill NL04 = 1.15e20 |
| Jan 12 1996 11:44:24:070AM | 960112015 | John Goetz | Shot 960112015:
more PG3 volts and NL04 = 1.6e20 Results: fizzle (weak one) radial field 1mT (on 951218 it was 1.5mT) |
| Jan 12 1996 12:05:08:780PM | 960112016 | John Goetz | Shot 960112016:
remove 2msec from prefill (now 14msec) BR_0 offset = .0075 Results: plasma - disruption @ 1.34 NL04 = 1.5e20, but only after a divertor detachment @ 1.57; then the gas gets in shark fin fill pressure = 0.8e-5 |
| Jan 12 1996 12:11:38:470PM | 960112017 | John Goetz | Shot 960112017:
enable PG2 with 20PSIA deuterium draw 30V square wave on PG2 from .3 to .9 sec Results: fizzle (weak) Bz may need to come in earlier |
| Jan 12 1996 12:27:04:490PM | 960112018 | John Goetz | Shot 960112018:
IC_EF4 = -1130A Results: plasma - disr. @ 1.34 due to a shark fin no RF again; divertor detachment |
| Jan 12 1996 12:37:31:770PM | 960112019 | John Goetz | Shot 960112019:
NL04 = 1.9e20 (expect 1.8e20) PG2 volts = 45 Results: fizzle - fields look o.k. - can't read the fill |
| Jan 12 1996 12:48:06:930PM | 960112020 | John Goetz | Shot 960112020:
no changes Results: fizzle - why?? |
| Jan 12 1996 01:00:39:630PM | 960112021 | John Goetz | Shot 960112021:
BR_0 offset = .0069 Results: plasma - disr. @ 1.21 good current rise only get to requested density at end of discharge |
| Jan 12 1996 01:10:37:540PM | 960112022 | John Goetz | Shot 960112022:
BR_0 offset = .0064 add 100V pulse to PG2 to make sure the valve opens Results: fizzle - fields look fine |
| Jan 12 1996 01:23:42:360PM | 960112023 | John Goetz | Shot 960112023:
reload 960112008 - a fiducial Results: plasma - all the way down not the best current rise, but adequate good fiducial |
| Jan 12 1996 01:33:22:310PM | 960112024 | John Goetz | Shot 960112024:
NL04 = 0.8e20 and less PG3 volts BR_0 offset = .0064 and V_OH1=150V from .005 to .015 Results: fizzle - fields look o.k. |
| Jan 12 1996 01:51:37:990PM | 960112025 | John Goetz | Shot 960112025:
no changes Results: plasma - all the way down density creeping up during the shot ( wall fueling? ) |
| Jan 12 1996 02:01:07:460PM | 960112026 | John Goetz | Shot 960112026:
remove some PG3 volts (down to 20V) Results: plasma - all the way down NL04 = 0.8 -> 0.9e20 |
| Jan 12 1996 02:10:45:870PM | 960112027 | John Goetz | Shot 960112027:
remove some PG3 volts (down to 10V) NL04 = 0.69e20 Results: plasma - all the way down NL04 = 0.8e20 and fairly constant ELMy H-mode |
| Jan 12 1996 02:27:14:520PM | 960112028 | John Goetz | Shot 960112028:
PG3 = 0V NL04 = 0.55e20 Results: fizzle (strong) Dalpha just never burns out |
| Jan 12 1996 02:33:51:210PM | 960112029 | John Goetz | Shot 960112029:
no changes Results: fizzle (strong) Wolfe says Br too negative |
| Jan 12 1996 02:46:07:620PM | 960112030 | John Goetz | Shot 960112030:
BR_0 offset = .0069 V_OH1 = 170V from .005 to .015 Results: plasma - all the way down NL04 = 0.6e20 |
| Jan 12 1996 02:54:18:390PM | 960112031 | John Goetz | Shot 960112031:
no changes Results: plasma - all the way down NL04 = 0.66e20 RF tried to stay on |
| Jan 12 1996 03:12:01:610PM | 960112032 | John Goetz | Shot 960112032:
no changes Results: plasma - all the way down ohmic H-mode @ 0.56 (NL04 = 0.66e20 before transition) RF H-modes later |
| Jan 12 1996 03:12:03:110PM | 960112032 | John Goetz | Shot 960112032:
no changes Results: plasma - all the way down ohmic H-mode @ 0.56 (NL04 = 0.66e20 before transition) RF H-modes later |
| Jan 12 1996 03:20:23:440PM | 960112033 | John Goetz | Shot 960112033:
disable Argon puff Results: plasma - all the way down NL04 = 0.55e20 no RF |
| Jan 12 1996 03:33:29:880PM | 960112034 | John Goetz | Shot 960112034:
NL04 = 1e20 and PG3 = 25V Results: plasma - all the way down NL04 = 0.9->1.0e20 0.3MW of RF power (H-mode) |
| Jan 12 1996 03:43:41:670PM | 960112035 | John Goetz | Shot 960112035:
PG3 = 35V Results: plasma - all the way down RF power = 1.0MW (H-mode) |
| Jan 12 1996 04:01:02:170PM | 960112036 | John Goetz | Shot 960112036:
no changes Results: plasma - all the way down NL04 => 1.1e20 RF power = 1.5MW |
| Jan 12 1996 04:27:30:530PM | 960112037 | John Goetz | Shot 960112037:
setup for fiducial PG3 = 30V Results: plasma - all the way down acceptable fiducial |
| Jan 12 1996 04:48:48:530PM | 960112038 | John Goetz | Shot 960112038:
enable Ar puff (12msec) enable LPI for attempt at PEP-mode Results: fizzle (weak) |
| Jan 12 1996 04:57:48:130PM | 960112039 | John Goetz | Shot 960112039:
no changes Results: plasma - disr. @ 1.19 no Li pellet |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:41:07:750AM | Test | Ok | |
| 2 | 08:53:04:770AM | Plasma | Ok | |
| 3 | 09:12:28:870AM | Plasma | Ok | |
| 4 | 09:26:51:650AM | Plasma | Ok | |
| 5 | 09:38:35:250AM | Plasma | Ok | |
| 6 | 09:48:34:980AM | Plasma | Ok | |
| 7 | 10:01:04:570AM | Plasma | Ok | |
| 8 | 10:11:18:980AM | Plasma | Ok | |
| 9 | 10:21:36:720AM | Plasma | Ok | |
| 10 | 10:33:54:240AM | Plasma | Ok | |
| 11 | 10:46:50:500AM | Plasma | Ok | |
| 12 | 11:00:48:390AM | Plasma | Ok | |
| 13 | 11:15:06:170AM | Plasma | Ok | |
| 14 | 11:23:43:310AM | Plasma | Ok | |
| 15 | 11:34:51:310AM | Plasma | Ok | |
| 16 | 11:50:25:010AM | Plasma | Ok | |
| 17 | 12:04:54:630PM | Plasma | Ok | |
| 18 | 12:13:11:560PM | Plasma | Ok | |
| 19 | 12:30:47:920PM | Plasma | Ok | |
| 20 | 12:40:44:600PM | Plasma | Ok | |
| 21 | 12:49:49:990PM | Plasma | Ok | |
| 22 | 01:03:34:170PM | Plasma | Ok | |
| 23 | 01:12:13:220PM | Plasma | Ok | No Faults. |
| 24 | 01:26:59:730PM | Plasma | Ok | comm fault bybass OH2U & OH1 |
| 25 | 01:39:35:900PM | Plasma | Ok | |
| 26 | 01:51:51:060PM | Plasma | Ok | no faults |
| 27 | 02:02:49:430PM | Plasma | Ok | |
| 28 | 02:14:17:170PM | Plasma | Ok | |
| 29 | 02:25:31:630PM | Plasma | Ok | OH2 Comm. Fault Bypass |
| 30 | 02:35:36:930PM | Plasma | Ok | |
| 31 | 02:48:15:290PM | Plasma | Ok | |
| 32 | 02:59:11:890PM | Plasma | Ok | |
| 33 | 03:12:44:390PM | Plasma | Ok | |
| 34 | 03:25:30:760PM | Plasma | Ok | |
| 35 | 03:36:38:610PM | Plasma | Ok | |
| 36 | 03:53:28:690PM | Plasma | Ok | |
| 37 | 04:18:07:570PM | Plasma | Ok | |
| 38 | 04:42:53:350PM | Plasma | Ok | |
| 39 | 04:51:25:990PM | Plasma | Ok | |