| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Unknown |
| Physics operator(s): | Steve Wolfe |
| Engineering operator(s): | Unknown |
| Engineering Operator Run Comment |
| power tests |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Physics Operator Summaries |
| Session Leader Comments |
| Physics Operator Comments | |||
| May 12 1997 09:26:11:470AM | 970512003 | Steve Wolfe | Checking on the cross-talk issue: loaded a model with the EF1U&L P and I gains set to zero. Supposed to be a EF1 PLC test. Result - no supply fired Cross talk down by about a factor of 2. Saturated channels are EF2's and EF4. |
| May 12 1997 10:03:20:380AM | 970512006 | Steve Wolfe | Shot 6: Set up to double swing EF1's. Normal initial rise to -4800A, reverse swing to 2000A. No commutation. P gain only, set at 2.0 Looks good. Voltage follows demand (mostly). Small bursts of oscillations at -1.1 to -1.0, and neat peak voltage ~+.370sec |
| May 12 1997 10:04:59:740AM | 970512007 | Steve Wolfe | Shot 7: Same as 6, but with commutation. Looks about the same. |
| May 12 1997 10:46:22:500AM | 970512009 | Steve Wolfe | Shot 9: TF only No current: Forgot to write the control screen |
| May 12 1997 10:55:44:470AM | 970512009 | Steve Wolfe | Shot 10: TF only - try again TF rogowski screwed up - looks like a bad integrator gate. Gas burst starts around 0.6 sec. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:32:05:650AM | Test | Ok | |
| 2 | 08:36:49:840AM | Test | Ok | |
| 3 | 08:52:23:810AM | Test | Bad | no pulse |
| 4 | 09:27:50:380AM | Test | Ok | |
| 5 | 09:33:27:390AM | Test | Ok | |
| 6 | 09:50:05:300AM | Test | Ok | |
| 7 | 10:00:51:410AM | Test | Ok | |
| 8 | 10:12:39:950AM | Test | Ok | |
| 9 | 10:42:54:250AM | Test | Ok | |
| 10 | 10:47:37:160AM | Test | Ok | |
| 11 | 10:56:44:300AM | Test | Bad | no pulse |
| 13 | 11:25:47:590AM | Test | Ok | |
| 14 | 11:34:36:590AM | Test | Ok | |