| Miniproposals | ||||||||||
|
| Operators | |
| Session leader(s): | Steve Wolfe |
| Physics operator(s): | Joseph Snipes |
| Engineering operator(s): | Frank Silva |
| Engineering Operator Run Comment |
| MP170 Restart |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:36:57:287PM |
| Author: To Be Determined |
| Attempt to get plasmas. Shot 1: EF3 test under PLC control to check magnetics timing. O.K. Shot 2: Copied shot 970521050. Fizzle. EF3 problems. Shot 3: EF3's crowbarred before t=0 leading to induced currents of several kA causing a dud. Shot 4: EF3 test under PLC control. EF3 breaker will not open. No current. End of run to sort out EF3 breaker problem. |
| Session Leader Comments | |||
| May 22 1997 07:38:01:860AM | Steve Wolfe | Before today's run, we had Tommy turn on the spare ion gauge on J-port, which has a straight-in, but possibly obstructed view. The IGT gauge we normally use is on a side-arm, with no possible line-of-sight to the chamber. For today, the spare gauge is just on a local controller in the cell, not under PLC control. There was a pressure burst after the gauge was turned on, as it outgassed. Now coming back down. GDC was turned off at 5:50AM. It had been on overnight, up to 430mA. | |
| May 22 1997 08:20:28:080AM | Steve Wolfe | Ran coldstart (HYBINIT_DISPATCH) 07:38 Set up for EF3 test. 2000V, 3kA start at -.05 sec, fizzle detector at .08sec, | |
| May 22 1997 08:26:08:130AM | 970522001 | Steve Wolfe | Shot 1: EF3 only test to check magnetics tree timing problem. Timing looks fine. Joe accepts Frank's apology. |
| May 22 1997 08:49:11:510AM | 970522002 | Steve Wolfe | Shot 2: Copy from shot 50 from yesterday. fizzle. bd at 6.6msec DEv Not triggered on MAG_TRAQ_1. can't run MFLUX also didn't work on shot 1; or on a test shot just now. Worked last night. |
| May 22 1997 03:15:02:730PM | 970522003 | Steve Wolfe | Shot 3: TRAQ3 was in local mode. Joe cycled the crate and it now passes the test Frank reports that EF2L has been running about 30C warmer than intended for the past 3 days due to an instrumentation problem. This would be consistent with the observed imbalance in the EF2's (U had more current), but may be irrelevant. We will monitor. No changes in PCS. LONGGGGG Delay for an EF3 breaker problem. Then an open thermocouple caused the heaters to pull out. Dud. EF3 came on at -1.1sec and ran to 4000A by t=0. EF3 seems to have crowbarred early, but there is a funny voltage after the current drops to zero. |
| May 22 1997 03:27:49:880PM | 970522004 | Steve Wolfe | Shot 4: EF3-only test, to see if EF3 is working now. NO current; EF3 breaker froze in closed position. Run cancelled. |
| Physics Operator Comments | |||
| May 22 1997 08:30:38:990AM | 970522001 | Joseph Snipes | EF3 test for magnetics timing. O.K. |
| May 22 1997 08:31:54:980AM | 970522002 | Joseph Snipes | Copied shot 970521050 to try to get standard reproducible plasmas at 0.8 MA and 5.4 T. Fizzle! |
| May 22 1997 09:01:51:010AM | 970522002 | Joseph Snipes | TRAQ1 on magnetics failed to trigger. I went into the cell and found it in local mode, switched off crates GKC408 and GKC419 and then back on. I reset them in CTS and took a test shot 105 with the main magnetics signals. It went through fine. So, we'll try again. |
| May 22 1997 09:16:40:160AM | 970522002 | Joseph Snipes | Short delay due to EF3 breaker problems |
| May 22 1997 10:02:01:480AM | 970522002 | Joseph Snipes | More than a short delay due to EF3 breaker problems |
| May 22 1997 01:12:32:410PM | 970522002 | Joseph Snipes | The delay may end the run. There will be at least another hour delay and if it goes longer, we will end the run. |
| May 22 1997 03:02:10:990PM | 970522003 | Joseph Snipes | EF3 crowbar before t=0 caused a dud. |
| May 22 1997 03:19:16:740PM | 970522004 | Joseph Snipes | EF3 breaker failed to open. No current. |
| May 22 1997 03:19:45:340PM | 970522004 | Joseph Snipes | Run ended to fix EF3 breaker problem. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:20:04:140AM | Test | Ok | EF3 Test for magnetics/3KA,2kv |
| 2 | 08:30:21:120AM | Plasma | Ok | |
| 3 | 02:55:37:650PM | Plasma | Bad | |
| 4 | 03:15:18:700PM | Test | Bad | |