Alcator C-Mod Run 990219 Information

Back to runs

Miniproposals
Miniproposal:214
Date Filed: 1/5/1999
Title:D and E-port RF System Commissioning
First Author:Steve Wukitch
Session Leader:Steve Wukitch (shots 1-30)

Operators
Session leader(s):Steve Wukitch
Physics operator(s):John Goetz,Bill Rowan
Engineering operator(s):Frank Silva

Engineering Operator Run Comment
MP 214 RF Conditioning/Rowan, Goetz/Silva

Session Leader Plans

Physics Operators Plans

Session Leader Summaries
Entered: Jul 7 2004 03:49:19:180PM
Author: To Be Determined
Run Plan for 990219

Miniproposal 214. RF Conditioning

Physop: Rowan/Goetz

Overnight ECDC in D2

Engineering Setup
------------------
Power supply setup as in shot 990218027
TF under hybrid control

Gas setup:
B-top 6 psi D2 Hybrid enabled
C-side 30 psi D2 hybrid enabled
B-side lower 1 psi of Ar hybrid disabled
B-side upper 20 psi He, disabled

Plan
-------------

Run fiducial like shots in order to allow conditioning of RF.

Goals
-------------

1. Demonstrate transmitters can run simultaneously to at least 1.25
MW.

2. Demonstrate reasonable power control for both transmitters
particularly in H-mode.


ST1: 603 PS1: 411 ST2: 2367 PS2: 1050

001 fizzle
002 fizzle
003 plasma good EDA
1.25 MW net power
one fault on FMIT#1
H/D~0.04-0.05
next shot: raise power by ~0.5 MW
ST1: 595 PS1: 412 ST2: 2598 PS2: 908

004 plasma two EDAs
faults on both H/D~0.04-0.05

[-2.18845,-.383501,-.222128]
recalculate coefficients for D-port
[-1.7498734,0.29566671,-1.5072494]

005 plasma with clean RF
D-port is still giving different power for same input voltage

new coefficients
[-1.8480706,0.33742668,-1.3710986]

006 plasma EDA
large injection which terminated the EDA also tripped the RF
007 plasma EDA
arcing on #2
next shot: lower drive on #2
008 plasma EDA
late fault (associated with injection)
next shot: raise drive on both
009 plasma early disruption
good RF up to the brick
010 fizzle

next shot: changed modulation board (feedback control) on #1
will need to recalculate MW coefficients
run the xmtrs separated to get new MW coefficients

011 early disruption

012 plasma late H-mode
screen overcurrent on #1 and #1 is oscillating
013 plasma H-mode
screen overcurrent on #1 and it is still oscillating
014 plasma H-mode
faults on #2 and #1 is still oscillating
next shot: lower drive on #2

015 plasma
#1 is still oscillating
016 plasma
#1 is still oscillating
017 plasma
#1 is still oscillating
018 plasma
#1 is still oscillating
next shot: replace mod-board with one used earlier in run and raise power

019 plasma interesting EDA

020 plasma EDA
next shot: increase RF drive and BT sweep for ECE at 0.9 sec

021 fizzle
022 plasma
PRF~2.8 MW
023 plasma
screen current overload
next shot: lower drive and attempt to lock sawteeth with RF modulation
024 plasma
injection which kills the RF
screen overcurrent on #1
#1 screen voltage is not dumping upon crowbar
sawteeth did not lock to 0.5 MW modulation
next shot: raise Ip->1.0 MA and modulation
025 plasma
1 MA; lousy RF

next shot: lower drive
open flappers before shot and close at 1.0 sec
026 plasma
no flap
027 plasma
faults on E-port are numerous
D-port has continued problems

*****************
*** SUMMARY ***
*****************

Although the RF system performed better than it has lately, we did not
accomplish either of the goals. The power feedback gain is
insufficient to compensate for changes in total gain of the
transmitter. We attempted to modify the feedback during the run, but
this was unsuccessful (resulted in power oscillations).

Physics Operator Summaries
Entered: Jul 7 2004 04:37:00:253PM
Author: To Be Determined
Physop Run Summary for 990219

SL: Steve Wukitch
PO: Rowan/Goetz
EO: Frank Silva


Overnight ECDC in D2

Engineering Setup
------------------
Power supply setup as in shot 990218027
TF under hybrid control

Gas setup:
B-top 6 psi D2 Hybrid enabled
C-side 30 psi D2 hybrid enabled
B-side lower 1 psi of Ar hybrid disabled
B-side upper 20 psi He, disabled


The goal was to execute Miniproposal 214. Briefly, the goal was to run
fiducial-like shots in order to allow conditioning of RF. Refer to the Session
Leader's summary for more detail and for comments on the progress toward
conditioning.

Note: If the setup for any of these shots is reused later, it should be noted
that there is a 5% BT ramp at the end of shots 021 to 030 for ECE calibration.

Note: The physop log erroneously states that the flappers were opened on 026.
There was an attempt on that shot and on subsequent shots, but these were not
successful.

Prior to beginning this run, it was noted that Thursday's physop reduced BR
slightly to avoid fizzles. We copied the setup for shot 0990217025 from
Wednesday. The first two shots were fizzles. BR was lowered as recommended in
the phyop log from Thursday, and we started to get plasmas.

A vertical position oscillation was brought to the attention of the physops.
Modifications were made to the slow feedback on shots 010 and 020 to
reduce the oscillation. These appeared to be successful.

The ECE-folk requested a 5% BT rampup at the end of the shot for ECE
calibration. This was started at 0.85s. After a couple of shots, a rampdown
was added at the request of the Session Leader.

The current was increased to 1MA on shot 025 at the request of the session
leader. This continued until the end of the run.


Shot 001. fizzle
Shot 002. fizzle
Shot 003. plasma. BR offset reduced from 3.5mT to 3.0 mT.
Shot 004. plasma
Shot 005. plasma
Shot 006. plasma
Shot 007. plasma
Shot 008. plasma
Shot 009. plasma. disrupted at 1 s
Shot 010. fizzle
Shot 011. plasma. disrupted at 0.45 s
Shot 012. plasma
Shot 013. plasma
Shot 014. plasma
Shot 015. plasma
Shot 016. plasma
Shot 017. plasma
Shot 018. plasma
Shot 019. plasma
Shot 020. plasma
Shot 021. fizzle. Added 5% BT ramp up from 0.85 s to 1.2 s.
Shot 022. plasma
Shot 023. plasma
Shot 024. plasma. Added BT ramp down after 1.1s
Shot 025. plasma. 1 MA on this and subsequent shots
Shot 026. plasma
Shot 027. plasma
Shot 028. plasma
Shot 029. plasma
Shot 030. plasma

Scorecard

Plasmas 26
Fizzles 4
Duds 0

Total 30


Session Leader Comments
Feb 19 1999 09:23:35:450AM990219001Steve Wukitch001 fizzle
Feb 19 1999 09:23:46:373AM990219002Steve Wukitch002 fizzle
Feb 19 1999 09:24:19:717AM990219003Steve Wukitch003 plasma good EDA
1.25 MW net power
next shot: raise power byabout 0.5 MW
Feb 19 1999 10:06:55:250AM990219003Steve Wukitch004 plasma two EDAs
faults on both xmtrs
Feb 19 1999 10:07:17:937AM990219005Steve Wukitch005 plasma with clean RF
D-port is still giving different power for same input voltage
Feb 19 1999 10:48:44:750AM990219006Steve Wukitch006 plasma EDA
large injection which terminated the EDA also tripped the RF
Feb 19 1999 10:49:14:263AM990219007Steve Wukitch007 plasma EDA
arcing on #2
next shot: lower #2 drive
Feb 19 1999 10:49:38:187AM990219008Steve Wukitch008 plasma EDA
late fault (associated with injection)
next shot: increase drive on #1 and #2
Feb 19 1999 11:10:15:170AM990219009Steve Wukitch009 plasma early disruption
good RF up to the brick
Feb 19 1999 11:32:35:700AM990219010Steve Wukitch010 fizzle

next shot: changed modulation board (feedback control) on #1
will need to recalculate MW coefficients
run the xmtrs separated to get new MW coefficients
Feb 19 1999 11:39:52:733AM990219011Steve Wukitch011 early disruption near crossover
Feb 19 1999 12:16:14:170PM990219012Steve Wukitch012 plasma late H-mode
screen overcurrent on #1 and #1 is oscillating
Feb 19 1999 01:14:37:890PM990219013Steve Wukitch013 plasma H-mode
screen overcurrent on #1 and it is still oscillating
Feb 19 1999 01:14:55:280PM990219014Steve Wukitch014 plasma H-mode
screen overcurrent on #1 and it is still oscillating
Feb 19 1999 01:15:08:530PM990219015Steve Wukitch015 plasma
#1 is still oscillating
Feb 19 1999 01:15:26:687PM990219016Steve Wukitch016 plasma
#1 is still oscillating
Feb 19 1999 01:15:41:607PM990219017Steve Wukitch017 plasma
#1 is still oscillating
Feb 19 1999 02:12:53:967PM990219018Steve Wukitch018 plasma
#1 is still oscillating
next shot: replace mod-board with one used earlier in run and raise power
Feb 19 1999 02:13:04:653PM990219019Steve Wukitch019 plasma interesting EDA
Feb 19 1999 02:13:16:590PM990219020Steve Wukitch020 plasma EDA
next shot: increase RF drive and BT sweep for ECE at 0.9 sec
Feb 19 1999 02:41:59:200PM990219021Steve Wukitch021 fizzle
Feb 19 1999 02:46:19:793PM990219022Steve Wukitch022 plasma
PRF~2.8 MW
Feb 19 1999 02:46:34:640PM990219023Steve Wukitch023 plasma
screen current overload
Feb 19 1999 02:58:35:577PM990219023Steve Wukitchnext shot: lower drive and attempt to lock sawteeth with RF modulation
Feb 19 1999 03:06:45:840PM990219024Steve Wukitch024 plasma EDA
injection which kills the RF
screen overcurrent on #1

next shot: raise Ip->1.0 MA
Feb 19 1999 04:02:42:187PM990219025Steve Wukitch025 plasma
1 MA; lousy RF
Feb 19 1999 04:03:09:013PM990219026Steve Wukitch026 plasma
no flap

Physics Operator Comments
Feb 19 1999 08:09:48:750AMBill RowanMiniproposal 214. RF Conditioning

Physop: Rowan/Goetz

Overnight ECDC in D2

Engineering Setup
------------------
Power supply setup as in shot 990218027
TF under hybrid control

Gas setup:
B-top 6 psi D2 Hybrid enabled
C-side 30 psi D2 hybrid enabled
B-side lower 1 psi of Ar hybrid disabled
B-side upper 20 psi He, disabled

Hybrid coldstart at 7:50. No errors

Loaded shot 990217025
Feb 19 1999 08:57:51:170AM990219001Bill RowanMiniproposal 214. RF Conditioning


Shot 001. fizzle

Next shot: BR offset to 3.5 mT from 4.5 mT
Feb 19 1999 09:12:02:543AM990219002Bill RowanShot 002. fizzle

Next shot: BR offset to 3.0 mT from 3.5 mT
EF4 to -1280A to reduce BZ
Feb 19 1999 09:18:43:733AM990219003Bill RowanShot 003.

Shot ran 1.71s
Feb 19 1999 09:22:12:140AM990219003Bill Rowan
Session leader requested a modification to outer gap to hold at 1 cm
Feb 19 1999 09:48:45:450AM990219004Bill Rowan
Shot 004.

Outer gap is approx 1 cm.

Next shot: Moved Ar puff 10 ms earlier
Feb 19 1999 09:58:46:043AM990219005Bill Rowan
Shot 005.

Next shot: Move Ar puff 10 ms earlier
Feb 19 1999 10:24:44:513AM990219006Bill Rowan
Shot 006.

Shot ended at 1.7s.

Next shot: no changes
Feb 19 1999 10:40:22:060AM990219007Bill Rowan
Shot 007.

Plasma

Next shot: no changes
Feb 19 1999 10:48:07:420AM990219008Bill Rowan
Shot 008.

Plasma

Next shot: no changes
Feb 19 1999 11:04:30:687AM990219009Bill Rowan
Shot 009.

Disruption at 1s. Large injection.

Next shot: no changes

Feb 19 1999 11:21:29:420AM990219009Bill Rowan
Shot 010.

Fizzle

Power room access and cell access after this shot.

Changed slow ZCUR to remove z oscillation
Feb 19 1999 11:35:23:250AM990219010Bill Rowan
Shot 010.

Fizzle

Power room access and cell access after this shot.

Changed slow ZCUR to remove z oscillation
Feb 19 1999 11:36:21:873AM990219011Bill Rowan
Shot 011.

Disruption at 450 ms during OH1 crossover

Next shot: no changes
Feb 19 1999 11:42:30:483AM990219011Bill Rowan
Shot 011.

Disruption at 0.45s during OH1 crossover

Next shot: no changes
Feb 19 1999 11:57:19:077AM990219012Bill Rowan
Shot 012.

Plasma. 1.7s

Power room access for RF after this shot

Next shot: no changes
Feb 19 1999 12:12:39:590PM990219013Bill Rowan
Shot 013.

Plasma

Power room access for RF after this shot

Next shot: no changes
Feb 19 1999 12:31:21:983PM990219013Bill Rowan
Shot 014.

Plasma

Power room access for RF after this shot.

Next shot: no changes
Feb 19 1999 12:43:38:827PM990219015Bill Rowan
Shot 015.

Plasma

Power room access for RF after this shot.

Next shot: no changes
Feb 19 1999 01:02:41:920PM990219016Bill Rowan
Shot 016.

Plasma

Next shot: no changes
Feb 19 1999 01:16:19:140PM990219016Bill Rowan
Shot 017.

Plasma

Next shot: no changes
Feb 19 1999 01:28:39:873PM990219018Bill Rowan
Shot 018.

Plasma

Cell access after this shot.

Next shot: Changed slow ZCUR to attempt to reduce z oscillation
Feb 19 1999 01:44:21:043PM990219018Bill Rowan
Shot 018.

Plasma

Cell access after this shot.

Next shot: Changed slow ZCUR to attempt to reduce z oscillation
Feb 19 1999 01:50:15:560PM990219019Bill Rowan
Shot 019.

Plasma

Next shot: no changes
Feb 19 1999 02:08:07:513PM990219020Bill Rowan
Shot 020.

Plasma

Next shot: BT sweep 0.9s to 1.2 s
Feb 19 1999 02:17:18:653PM990219021Bill Rowan
Shot 021.

fizzle

Next shot: No changes
Feb 19 1999 02:34:20:623PM990219022Bill Rowan
Shot 022.

plasma. Apparent injection at 1s

Next shot: No changes
Feb 19 1999 02:44:56:310PM990219023Bill Rowan
Shot 023.

plasma. Apparent injection at 1s

Next shot: Add a down-jog in BT after 1.1 s
Feb 19 1999 03:29:25:530PM990219024Bill Rowan
Shot 024.

plasma

Power room access after this shot.

Next shot: Increase current to 1 MA
Feb 19 1999 03:40:57:140PM990219025Bill Rowan
Shot 025.

plasma

Next shot: Changed EF4 to attempt to improve current rise
Feb 19 1999 03:50:29:030PM990219025Bill Rowan
Shot 025.

plasma

Next shot: Changed EF4 to attempt to improve current rise
Feb 19 1999 04:02:59:873PM990219026Bill Rowan
Shot 026.

plasma

Flappers opened and closed at 1 s

Cell access after this shot to assure that omegatron insertion drive was not stuck

Next shot: Changed EF4 again to attempt to improve current rise

Feb 19 1999 04:25:06:560PM990219027Bill Rowan
Shot 027.

plasma

Next shot: Increased outer gap at request of session leader
Feb 19 1999 04:30:53:153PM990219028Bill Rowan
Shot 028.

plasma

Next shot: Increased outer gap at request of session leader
Feb 19 1999 05:03:59:937PM990219030Bill Rowan
Shot 030.

plasma

Last shot

Engineering Operator Comments
ShotTimeTypeStatusComment
108:46:41:857AMPlasmaOkno faults/fizzel
209:00:33:030AMPlasmaOkno faults/fizzel
309:13:37:000AMPlasmaOkno faults/plasma
409:31:15:123AMPlasmaOkno faults/plasma
509:49:51:467AMPlasmaOkno faults/plasma
610:06:20:653AMPlasmaOkno faults/plasma
710:25:22:000AMPlasmaOkno faults/plasma
810:38:42:170AMPlasmaOkno faults/plasma
910:56:51:670AMPlasmaOkno faults/plasma dis
1011:12:02:000AMPlasmaOkno faults
1111:27:40:403AMPlasmaOkOH1 SPCkt. fired/Disruption
1211:40:39:060AMPlasmaOkno faults/plasma
1312:00:19:030PMPlasmaOkno faults/plasma
1412:15:04:827PMPlasmaOkno faults/plasma
1512:30:50:403PMPlasmaOkno faults/plasma
1612:49:40:653PMPlasmaOkno faults/plasma
1701:03:25:013PMPlasmaOkno faults/plasma
1801:20:47:810PMPlasmaOkNo Faults / Plasma
1901:36:48:000PMPlasmaOkNo Faults / Plasma
2001:51:49:390PMPlasmaOkNo Faults / Plasma
2102:09:57:530PMPlasmaOkNo Faults
2202:23:12:670PMPlasmaOkNo Faults / Plasma
2302:38:15:840PMPlasmaOkNo Faults / Plasma
2402:58:53:373PMPlasmaOkno faults/plasma
2503:30:57:937PMPlasmaOkNo Faults / Plasma
2603:46:29:293PMPlasmaOkNo Faults / Plasma
2704:10:07:310PMPlasmaOkNo Faults / Plasma
2804:24:22:293PMPlasmaOkNo Faults / Plasma
2904:41:12:030PMPlasmaOkNo Faults / Plasma
3004:59:11:233PMPlasmaOkNo Faults / Plasma