| Session leader(s): | Rejean Boivin,Steve Wukitch |
| Physics operator(s): | Robert Granetz |
| Engineering operator(s): | Frank Silva |
| Engineering Operator Run Comment |
| MP #214 RF Conditioning/Granetz.Silva |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:08:210PM |
| Author: To Be Determined |
| Physics operator summary for run 990816: MP 214 -- RF conditioning SL: Dr. Wukitch, I presume? PO: R. Granetz The goal for today: Continue conditioning the RF. Summary: RF made great progress today. Both J3 and J4 followed their programmed power demand, individually and combined, for the most part. Instantaneous power of 2 MW was injected during the latter shots. There were also numerous examples of very large titanium injections, which must be coming from the J-port antenna. The machine ran very reliably until shot 17, and after that, the fizzle probability rose to nearly 50%, for unknown reasons. Scorecard: 17 plasmas 4 fizzles 1 dud (1 due to lack of one or more power supplies) 2 tests 0 aborted ---------- 24 total ------------------------------------------------------------------------------ Engineering Setup for Monday, 990816: Run will begin at 09:00. Setup power supplies from shot 990813008 (1 MA, 5.4 T, flattop to 1.4 s) Two hours of ECDC in D2 prior to the run. Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid enabled fill B-side upper with 6 psi of H2 Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled leave J-bottom as is Hybrid DISABLED The following gate valves should be enabled, assuming no vacuum problems: ECE, VUV ------------------------------------------------------------------------------- Run Plan for Monday, 990816: MP 214 -- RF conditioning Physics operator: R. Granetz Start from shot 990813008, a 1 MA, 5.4 T, long-flattop discharge. Continue RF development. ------------------------------------------------------------------------------- Note: There were two hours of ECDC in D2 prior to this run. Hybrid coldstart done; no errors found ($set default cmod$models:[hybrid.tcl] $@hybinit_dispatch $@show_bitbus_log Use editor search to verify no occurrences of "error" nor "not respond") Load 990813008 (1 MA, 5.4 T, long flattop, nl_04=1.0e20 m-2). Shot 01 -- Test; standard Tuesday morning OH test. Only the OH2's were turned on. Must repeat with OH1. Shot 02 -- Test; standard Tuesday morning OH test. Coax resistances look good. There will be a delay at this point to allow RF access to the power room. Shot 03 -- Plasma. Good shot. 1 MA, 5.4 T, nl_04=1.0-1.2e20 m-2, flattop to t=1.4 s, full rampdown, terminates at t=1.85 s. I think there's a little too much Bz. RF was not enabled. Next shot: change IC_EF4 from -1270 to -1280 amps. Shot 04 -- Plasma. Good shot. Got about 0.5 MW from J4, very little from J3. Right gap=1.1-1.2 cm. Bz looks better. Next shot: decrease outer gap to 1.0 cm. Shot 05 -- Plasma. Good shot. Still almost no power from J3 transmitter. Outer gap=1.0-1.1 cm. Next shot: change fizzle detector turnoff from t=2.2 to 1.7 s There will be a delay at this point to allow RF access to the power room. Shot 06 -- Plasma. Good shot. H2 concentration has been around 4% all morning. Outer gap=1.0 cm. Next shot: return fizzle detector timeout back to t=2.2 s. Shot 07 -- Plasma. Good shot. About 1 MW from each of J3 and J4, non- overlapped. Neutrons increase, but no H-modes. There were some big impurity injections during the RF. Outer gap=1.0 cm. Next shot: no changes. Shot 08 -- Plasma. Good shot. About 1 MW from each of J3 and J4, non- overlapped. There are signs of dithering on the H-alpha. Next shot: no changes Shot 09 -- Plasma. Good shot. J3 gave a flat 1.0 MW for 0.2 s, J4 gave a flat 0.67 MW for 0.19 s. RF looks pretty good. Still no H-modes. Next shot: no changes Shot 10 -- Plasma. Good shot, but it was almost killed by a big injection at t=1.15 s. J3 tried for 2 MW, but couldn't stay on steadily. J4 gave about 0.9 MW in a flat, steady pulse. H/D=4-5%. Outer gap=1.0 cm. Still no H-modes. Next shot: no changes. There will be a delay at this point to allow RF access to the power room. Shot 11 -- Plasma. Good shot. No RF. Next shot: no PCS changes. RF turned back on. Shot 12 -- Plasma. Good shot. Another big injection at 0.94 s. 1.2 MW from J3 and 0.9 MW from J4, both look pretty steady. No overlap yet. Next shot: no PCS changes Shot 13 -- Plasma. Good shot. Another big injection, this time at 0.81 s 1.2 MW from J3 and 0.9 MW from J4, both look pretty steady. No overlap yet. Jim Terry reports that the large injections are NOT molybdenum. Next shot: no PCS changes Shot 14 -- Dud. OH2L faulted before the shot, pulling out the PF breaker. Next shot: try again, no changes Note: Jim Terry and Dimitrios Pappas have determined that the large injections are titanium, which must be coming from the antennas. There will be a delay at this point to check the OH supplies and to allow RF access to the power room. Shot 15 -- Plasma. Good shot. Both J3 and J4 gave 1.2 MW each. Not overlapped yet. No large injection (just some small ones). No Te heating, no H-modes. Outer gap=1.0 cm. H/D=4-5%. Next shot: no PCS changes Jim Terry reports that the (small) injections on this shot consisted of iron and molybdenum. Shot 16 -- Plasma. Good shot. J3 and J4 overlapped for about 0.2 s at low power (0.4 MW from J3 and 0.2 MW from J4). No inpurity injections. Next shot: no PCS changes Shot 17 -- Fizzle. Next shot: reduce EF4 another 5 amps. (from -1280 to -1285 amps). Shot 18 -- Fizzle. Next shot: reduce EF4 another 5 amps. (-1285 to -1290 amps) Shot 19 -- Plasma. Good shot. Prf=1.5 MW total (from J-port). Dithering, but no H-modes. No big injections. Next shot: no PCS changes. Shot 20 -- Fizzle. Next shot: re-load shot 5. Note: We've filled up the shot disk and will have to wait for Tom Fredian to clear up some space for the next few shots. Shot 21 -- Plasma. Good shot. Prf=1.5 MW total. There was a big injection around 0.8 s. Current rise looked better than previous few shots. Next shot: no PCS changes Shot 22 -- Plasma. Good shot. Prf=1.5-2.0 MW. Prad=0.5 MW during the time that Prf=2 MW. Still don't see significant heating. Dimitrios Pappas reports that the Prad is due to molybdenum. Next shot: no PCS changes There will be a delay at this point to allow RF access to the power room. Shot 23 -- Fizzle. Next shot: substract 5 amps from EF4. Shot 24 -- Plasma. Good shot. Several big injections on 2pi bolo. Prf was approx. 2 MW. No heating. End of run. |
| Session Leader Comments | |||
| Aug 16 1999 09:52:32:250AM | Rejean Boivin | MP 214 Transmitters 1, 3 and 4 are available today. Try to get 3 and 4 to run together. New feedback circuit has been added to #1. We will try that one as well a bit later on. Plasmas will be the plain vanilla type. | |
| Aug 16 1999 09:54:02:920AM | 990816003 | Rejean Boivin | MP 214 Shot 003: RF not enabled, good plasma. |
| Aug 16 1999 10:54:14:373AM | 990816004 | Rejean Boivin | MP 214 Shot 004: Attempt with 3 and 4. #4 fires with ~0.7 MW. #3 has problems with gates. |
| Aug 16 1999 11:01:51:250AM | 990816005 | Rejean Boivin | MP 214 Shot 005: Attempt with 3 and 4. #4 fires with ~1.1 MW. #3 has problems with gates,still. |
| Aug 16 1999 11:02:24:043AM | 990816006 | Rejean Boivin | MP 214 Shot 006: Attempt with 3 and 4. #4 fires with ~1.1 MW. Trying to figure out gate problem with #3. |
| Aug 16 1999 12:35:23:483PM | 990816007 | Rejean Boivin | Shot 007 Both 3 and 4 fired, a little more from #4. Try some more next shot |
| Aug 16 1999 12:36:27:530PM | 990816008 | Rejean Boivin | Shot 008 Both 3 and 4 fired, #3 oscillating, at higher power. Square waveform next shot. |
| Aug 16 1999 12:38:06:670PM | 990816009 | Rejean Boivin | Shot 009 Both 3 and 4 fired, #3 still oscillating. |
| Aug 16 1999 12:39:35:043PM | 990816010 | Rejean Boivin | Shot 010 Both 3 and 4 fired, #3 still oscillating. |
| Aug 16 1999 12:40:14:200PM | 990816011 | Rejean Boivin | Shot 011 RF disabled, reenable for next shot. |
| Aug 16 1999 01:46:30:640PM | 990816012 | Rejean Boivin | Shot 012 3 and 4 firing, try to diagnose feedback/oscillation issues. |
| Aug 16 1999 01:46:51:090PM | 990816013 | Rejean Boivin | Shot 013 3 and 4 firing, with some overlap, not quite happy together. |
| Aug 16 1999 01:47:02:013PM | 990816014 | Rejean Boivin | Shot 014 No plasma |
| Aug 16 1999 02:38:08:357PM | 990816015 | Rejean Boivin | Shot 015 Change waveform for 3 and 4 to attempt diagnose feedback/gain issues. |
| Aug 16 1999 02:39:14:310PM | 990816016 | Rejean Boivin | Shot 016 Lower power for 3 and 4, with some overlap. Some success in overlapping but very low power level. Not quite symmetric responses between the 2 transmitters. Raise power for next shot. |
| Aug 16 1999 03:31:24:513PM | 990816019 | Rejean Boivin | Shot 019 More power from 3 and 4, about 1 MW from #3 and 0.6 MW from #4 together. The best so far. It seems that we are limited by some power supply in the RF "train". |
| Aug 16 1999 03:55:32:967PM | 990816021 | Rejean Boivin | Shot 021 Increasing power in #4, bringing the total power to close to 2MW together! We are basically at the limit in output power, but there is a few things we can change to increase that. Require access though. |
| Aug 16 1999 04:18:28:030PM | 990816022 | Rejean Boivin | Shot 022 Made it! 2MW together in plasma. That's the milestone for the new J antenna. Approx. 1 MW from each transmitter, for about 100 msec! |
| Physics Operator Comments | |||
| Aug 16 1999 09:06:22:217AM | Robert Granetz | Engineering Setup for Monday, 990816: Run will begin at 09:00. Setup power supplies from shot 990813008 (1 MA, 5.4 T, flattop to 1.4 s) Two hours of ECDC in D2 prior to the run. Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid enabled fill B-side upper with 6 psi of H2 Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled leave J-bottom as is Hybrid DISABLED The following gate valves should be enabled, assuming no vacuum problems: ECE, VUV | |
| Aug 16 1999 09:06:33:590AM | Robert Granetz | Run Plan for Monday, 990816: MP 214 -- RF conditioning Physics operator: R. Granetz Start from shot 990813008, a 1 MA, 5.4 T, long-flattop discharge. Continue RF development. | |
| Aug 16 1999 09:06:45:733AM | Robert Granetz | Note: There were two hours of ECDC in D2 prior to this run. Hybrid coldstart done; no errors found ($set default cmod$models:[hybrid.tcl] $@hybinit_dispatch $@show_bitbus_log Use editor search to verify no occurrences of "error" nor "not respond") Load 990813008 (1 MA, 5.4 T, long flattop, nl_04=1.0e20 m-2). | |
| Aug 16 1999 11:03:08:340AM | Ian Hutchinson | Update of fluxihh to account for problems with f29. Editted fluxihh to introduce a new logical f29dead that is set on and that causes f15 to be used instead. Also corrected dependencies in psilpsi to refer to ihh$code not user10 This had been done in the contihh PCS area but not in my local area. Made the changes across to the PCS area by MMS in [hutch.mds.predictor] Messages: %COPY-S-COPIED, USER10:[HUTCH.MDS.PREDICTOR]PSILPSI.PRO;4 copied to CMOD$MODELS: [HYBRID.IDL.USER_ALGS.CONTIHH]PSILPSI.PRO;4 (6 blocks) %COPY-S-COPIED, USER10:[HUTCH.MDS.PREDICTOR]FLUXIHH.PRO;9 copied to CMOD$MODELS: [HYBRID.IDL.USER_ALGS.CONTIHH]FLUXIHH.PRO;26 (53 blocks) %COPY-S-COPIED, USER10:[HUTCH.MDS.MFIL]FBUP.PRO;21 copied to CMOD$MODELS:[HYBRID .IDL.USER_ALGS.CONTIHH]FBUP.PRO;21 (7 blocks) %COPY-S-COPIED, USER10:[HUTCH.MDS.MFIL]IANUP.PRO;22 copied to CMOD$MODELS:[HYBRI D.IDL.USER_ALGS.CONTIHH]IANUP.PRO;18 (4 blocks) %COPY-S-COPIED, USER10:[HUTCH.MDS.MFIL]FILCOM.H;17 copied to CMOD$MODELS:[HYBRID .IDL.USER_ALGS.CONTIHH]FILCOM.H;15 (1 block) There were indeed some changes related to lfilinv in ianup.pro and filcom.h | |
| Aug 16 1999 09:06:57:983AM | 990816001 | Robert Granetz | Shot 01 -- Test; standard Tuesday morning OH test. Only the OH2's were turned on. Must repeat with OH1. |
| Aug 16 1999 09:13:59:623AM | 990816002 | Robert Granetz | Shot 02 -- Test; standard Tuesday morning OH test. Coax resistances look good. |
| Aug 16 1999 10:05:43:967AM | 990816003 | Robert Granetz | Shot 03 -- Plasma. Good shot. 1 MA, 5.4 T, nl_04=1.0-1.2e20 m-2, flattop to t=1.4 s, full rampdown, terminates at t=1.85 s. I think there's a little too much Bz. RF was not enabled. Next shot: change IC_EF4 from -1270 to -1280 amps. |
| Aug 16 1999 10:11:14:107AM | 990816004 | Robert Granetz | Shot 04 -- Plasma. Good shot. Got about 0.5 MW from J4, very little from J3. Right gap=1.1-1.2 cm. Bz looks better. Next shot: decrease outer gap to 1.0 cm. |
| Aug 16 1999 10:43:57:293AM | 990816005 | Robert Granetz | Shot 05 -- Plasma. Good shot. Still almost no power from J3 transmitter. Outer gap=1.0-1.1 cm. Next shot: change fizzle detector turnoff from t=2.2 to 1.7 s There will be a delay at this point to allow RF access to the power room. |
| Aug 16 1999 10:50:49:623AM | 990816006 | Robert Granetz | Shot 06 -- Plasma. Good shot. H2 concentration has been around 4% all morning. Outer gap=1.0 cm. Next shot: return fizzle detector timeout back to t=2.2 s. |
| Aug 16 1999 11:15:18:090AM | 990816007 | Robert Granetz | Shot 07 -- Plasma. Good shot. About 1 MW from each of J3 and J4, non- overlapped. Neutrons increase, but no H-modes. There were some big impurity injections during the RF. Outer gap=1.0 cm. Next shot: no changes. |
| Aug 16 1999 11:29:59:000AM | 990816008 | Robert Granetz | Shot 08 -- Plasma. Good shot. About 1 MW from each of J3 and J4, non- overlapped. There are signs of dithering on the H-alpha. Next shot: no changes |
| Aug 16 1999 11:57:57:467AM | 990816009 | Robert Granetz | Shot 09 -- Plasma. Good shot. J3 gave a flat 1.0 MW for 0.2 s, J4 gave a flat 0.67 MW for 0.19 s. RF looks pretty good. Still no H-modes. Next shot: no changes |
| Aug 16 1999 12:09:17:123PM | 990816010 | Robert Granetz | Shot 10 -- Plasma. Good shot, but it was almost killed by a big injection at t=1.15 s. J3 tried for 2 MW, but couldn't stay on steadily. J4 gave about 0.9 MW in a flat, steady pulse. H/D=4-5%. Outer gap=1.0 cm. Still no H-modes. Next shot: no changes. There will be a delay at this point to allow RF access to the power room. |
| Aug 16 1999 12:23:20:293PM | 990816011 | Robert Granetz | Shot 11 -- Plasma. Good shot. No RF. Next shot: no PCS changes. RF turned back on. |
| Aug 16 1999 12:44:29:000PM | 990816012 | Robert Granetz | Shot 12 -- Plasma. Good shot. Another big injection at 0.94 s. 1.2 MW from J3 and 0.9 MW from J4, both look pretty steady. No overlap yet. Next shot: no PCS changes |
| Aug 16 1999 01:13:34:590PM | 990816013 | Robert Granetz | Shot 13 -- Plasma. Good shot. Another big injection, this time at 0.81 s 1.2 MW from J3 and 0.9 MW from J4, both look pretty steady. No overlap yet. Jim Terry reports that the large injections are NOT molybdenum. Next shot: no PCS changes |
| Aug 16 1999 01:20:36:090PM | 990816014 | Robert Granetz | Shot 14 -- Dud. OH2L faulted before the shot, pulling out the PF breaker. Next shot: try again, no changes |
| Aug 16 1999 01:26:13:733PM | 990816014 | Robert Granetz | Note: Jim Terry and Dimitrios Pappas have determined that the large injections are titanium, which must be coming from the antennas. |
| Aug 16 1999 01:33:54:780PM | 990816014 | Robert Granetz | There will be a delay at this point to check the OH supplies and to allow RF access to the power room. |
| Aug 16 1999 02:00:36:763PM | 990816015 | Robert Granetz | Shot 15 -- Plasma. Good shot. Both J3 and J4 gave 1.2 MW each. Not overlapped yet. No large injection (just some small ones). No Te heating, no H-modes. Outer gap=1.0 cm. H/D=4-5%. Next shot: no PCS changes |
| Aug 16 1999 03:51:10:250PM | 990816015 | Robert Granetz | Jim Terry reports that the (small) injections on this shot consisted of iron and molybdenum. |
| Aug 16 1999 02:47:18:950PM | 990816017 | Robert Granetz | Shot 17 -- Fizzle. Next shot: reduce EF4 another 5 amps. (from -1280 to -1285 amps). |
| Aug 16 1999 03:01:25:403PM | 990816018 | Robert Granetz | Shot 18 -- Fizzle. Next shot: reduce EF4 another 5 amps. (-1285 to -1290 amps) |
| Aug 16 1999 03:17:37:090PM | 990816019 | Robert Granetz | Shot 19 -- Plasma. Good shot. Prf=1.5 MW total (from J-port). Dithering, but no H-modes. No big injections. Next shot: no PCS changes. |
| Aug 16 1999 03:38:50:653PM | 990816020 | Robert Granetz | Shot 20 -- Fizzle. Next shot: re-load shot 5. Note: We've filled up the shot disk and will have to wait for Tom Fredian to clear up some space for the next few shots. |
| Aug 16 1999 03:50:09:437PM | 990816021 | Robert Granetz | Shot 21 -- Plasma. Good shot. Prf=1.5 MW total. There was a big injection around 0.8 s. Current rise looked better than previous few shots. Next shot: no PCS changes |
| Aug 16 1999 04:18:09:483PM | 990816022 | Robert Granetz | Shot 22 -- Plasma. Good shot. Prf=1.5-2.0 MW. Prad=0.5 MW during the time that Prf=2 MW. Still don't see significant heating. Dimitrios Pappas reports that the Prad is due to molybdenum. Next shot: no PCS changes There will be a delay at this point to allow RF access to the power room. |
| Aug 16 1999 04:34:50:437PM | 990816023 | Robert Granetz | Shot 23 -- Fizzle. Next shot: substract 5 amps from EF4. |
| Aug 16 1999 04:38:38:043PM | 990816024 | Robert Granetz | Shot 24 -- Plasma. Good shot. Several big injections on 2pi bolo. Prf was approx. 2 MW. No heating. End of run. |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 08:57:00:500AM | Test | Bad | OH1 Didnot fire/not enabled |
| 2 | 09:06:06:687AM | Test | Ok | no faults |
| 3 | 09:46:00:043AM | Plasma | Ok | no faults |
| 4 | 10:02:16:763AM | Plasma | Ok | no faults |
| 5 | 10:20:36:250AM | Plasma | Ok | no faults |
| 6 | 10:42:50:577AM | Plasma | Ok | no faults Fizzell OFF time set to 1.7 sec. |
| 7 | 11:02:17:373AM | Plasma | Ok | no faults/ fizzell back to OFF 2.2 sec. |
| 8 | 11:20:56:670AM | Plasma | Ok | no faults |
| 9 | 11:40:30:840AM | Plasma | Ok | (null) |
| 10 | 12:00:18:560PM | Plasma | Ok | (null) |
| 11 | 12:17:59:090PM | Plasma | Ok | (null) |
| 12 | 12:37:54:983PM | Plasma | Ok | (null) |
| 13 | 12:56:55:217PM | Plasma | Ok | (null) |
| 14 | 01:16:06:293PM | Plasma | Bad | OH2Lower Crowbar |
| 15 | 01:52:02:357PM | Plasma | Ok | No Faults |
| 16 | 02:24:03:153PM | Plasma | Ok | (null) |
| 17 | 02:41:05:467PM | Plasma | Ok | (null) |
| 18 | 02:55:51:390PM | Plasma | Ok | (null) |
| 19 | 03:09:17:607PM | Plasma | Ok | (null) |
| 20 | 03:28:19:030PM | Plasma | Ok | (null) |
| 21 | 03:41:50:950PM | Plasma | Ok | (null) |
| 22 | 03:59:57:450PM | Plasma | Ok | (null) |
| 23 | 04:17:55:577PM | Plasma | Ok | (null) |
| 24 | 04:31:01:030PM | Plasma | Ok | (null) |