| ********* Run plan ********* - Test engineering systems to return to normal field configuration. - Test 3 and 4 (J) into dummy load for proper operation. - Recover normal plasma operation after boronization. Shot Schedule: 1. compare D, J-port (0,pi,0,pi,), J-port (0,pi,pi,0), J3, J4 at moderate power levels 0.5, 0.75, and 1.0 MW each step is 0.27 sec (5 good shots) 2. compare J-port (0,pi,0,pi,), J-port (0,pi,pi,0), J3, J4 at moderate power levels in H-mode D-port at 1.4 MW (4 good shots) 3. with J-port (0,pi,0,pi,) and D at constant power, scan B 4.4 T, 4.8 T, 5.2 T, and 5.6 T (4 good shots) 4. with J-port (0,pi,0,pi,) and D at constant power, scan outer gap 1.4, 1.0, and 0.6 cm. (3 good shots) 5. with J-port (0,pi,0,pi,) and D at constant power, scan Ip 0.6, 0.8, 1.0 and 1.2 MA. (4 good shots) ---------------------------------------------------------------------------- 021 early disruption 0.32 sec next shot: D-port: step up to 1 MW J-port : step up to 1 MW 022 plasma BT = 5.4 T only J4 fired J3 retried 9 times and D was missing a Kalmus next shot: decrease BT to 5.2 T and run D-port only with ~100 msec ramp on J-port 024 plasma- EDA at 750 kW BT = 5.2T next shot: retune and get D-port baseline 025 plasma- EDA at 750 kW BT = 5.2T only one fault on J-port next shot: give up on the D-port baseline J-port only with D-port on at 1.4 sec 026 plasma faulting on #3 at 0.5 MW step D-port only after 1.4 imputities on stepup to 1 MW from J-port next shot: repeat 027 plasma good shot for comparison (0,pi,0,pi,0) impurities are much lower but no H-mode ********** Summary ********** 1. Magnetic field tests were successful 2. FMIT#3 and #4 were successfully tested into dummy load. 3. Plasma operation was successfully resumed. Began shot plan, we succeeded in getting a good shot with J-port at (0,pi,0,pi). The D-port comparison shot was complicated by the EDA H-mode at 750 kW. The H fraction was around 3% which is too low. Tomarrow we should include a H gas puff to increase the H fraction. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:10:007PM |
| Author: To Be Determined |
| Run 991108 in support of MP214: RF Conditioning EOs: Silva, Cochran PO : Irby SL : Wukitch Run will BEGIN at 09:00 and END at 17:00 MP225: Determination of Mo Source, will ride along as possible. FMIT#3 and FMIT#4 should be made ready for operation. FMIT#1 should be warmed up and ready to go when needed. Run will begin with power tests to make sure the bus and instrumentation are back into "normal" mode. Setup power supplies from shot 991029024. This shot was a 5.4 T, 800 kA discharge, with a 1.5 s flattop. Programming will be modified to run the TF at 5.2 T. We will continue with 50 kA backporch on TF pulse. ECDC in Helium over the weekend at 2.0e-4 Torr. Two hours of ECDC in D2 at 2.e-4 Torr before the run (stopped by 08:00). Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid DISABLED fill B-side upper with 10 psi of H2 Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled Enable ECE and VUV Summary: Since the bus is now back in the normal direction, we started the run doing test shots on OH1, OH2U, and OH2L. All okay, but run was slowed down because of a problem in the Alternator. After a bad timer was replaced we successfully finished the power tests and began plasma shots. FMIT#3 and FMIT#4 were tested into the dummy load and then switched into the j-port antenna while the tests were going on. The first plasma attempt (21) resulted in a 0.327 second long plasma with a couple of injections. A repeat shot resulted in a nice long plasma. After a fizzle on shot 23, all remaining shots produced a good plasma. RF transmitters were coming back online during the run and should be in good shape for tomorrow. Made some adjustments to RCUR to keep the outer gap at 8 mm or so during h-mode. Problems: A bad timing relay in the exciter protection circuitry caused a several hour delay in the run today. The timer was supposed to extend the exciter on time well past the exciter supply rampdown. Lots of CAMAC errors during INIT on last two shots TCI CO2 laser power very low. Score: 27 shot cycles 20 tests 1 fizzle 6 plasmas --------------------------------------------------------------------------- --------------------------------------------------------------------------- --------------------------------------------------------------------------- ---------------------------------------------------------------------------- 991108xxx irby PHYSICS_OPERATOR Nov 8 1999 8:40:59:373AM . . . . . . . . . . . . . . . . . . . . Loaded shot 991029024 into PCS Did load/clean Did coldstart rtnode -- data loaded, A matrix responds rtnode -- data loaded, M matrix responds rtnode -- data loaded, PID matrix responds RT_NODE Done ---------------------------------------------------------------------------- 991108001 irby PHYSICS_OPERATOR Nov 8 1999 9:12:01:480AM . . . . . . . . . . . . . . . . . . . . 10 kA OH1 test No excitation on Alternator? Running through shot to keep data system in sync. Alternator claims that it was ramping up --- no indication on our display.. ---------------------------------------------------------------------------- 991108002 irby PHYSICS_OPERATOR Nov 8 1999 9:31:24:903AM . . . . . . . . . . . . . . . . . . . . No excitation again! Ran through shot, but had no Oh1 current. Found that exciter gate had RED light. It has now been reset. Had to reboot PLCs, STATE, ACCESS, ALTERNATOR in control room and in alternator ---------------------------------------------------------------------------- 991108003 irby PHYSICS_OPERATOR Nov 8 1999 9:36:51:060AM . . . . . . . . . . . . . . . . . . . . Alternator okay now. Next shot should be OH1 test ---------------------------------------------------------------------------- 991108004 irby PHYSICS_OPERATOR Nov 8 1999 10:00:07:420AM . . . . . . . . . . . . . . . . . . . . Another try at an OH1 test OH1 looks good. ---------------------------------------------------------------------------- 991108005 irby PHYSICS_OPERATOR Nov 8 1999 10:00:53:826AM . . . . . . . . . . . . . . . . . . . . OH2U looks okay ---------------------------------------------------------------------------- 991108006 irby PHYSICS_OPERATOR Nov 8 1999 10:11:22:186AM . . . . . . . . . . . . . . . . . . . . OH2L OH2L looks good ---------------------------------------------------------------------------- 991108007 irby PHYSICS_OPERATOR Nov 8 1999 10:48:00:450AM . . . . . . . . . . . . . . . . . . . . We have been losing the Alternator exciter breaker when we go into RECOOL. Looks like the Alternator thinks we are having a type 1 TF fault. Yuri, Frank, and Jim are checking it out. Lost most of the data for this shot since INIT was bypassed. ---------------------------------------------------------------------------- 991108008 irby PHYSICS_OPERATOR Nov 8 1999 11:24:50:106AM . . . . . . . . . . . . . . . . . . . . Looks like type 1 fault is local to the exciter supply and has nothing to do with the TF. Now looks like it's the AC breaker to the exciter that is the problem. FMIT#3 and FMIT#4 have been checked out into the dummy load. Steve is going out to switch them over to the antenna. ---------------------------------------------------------------------------- 991108009 irby PHYSICS_OPERATOR Nov 8 1999 12:07:22:873PM . . . . . . . . . . . . . . . . . . . . Bypassed INIT again. Alternator ramped up okay to 12.8 kV. Lost excitation as we went into recool again. AC exciter breaker pulled again. ---------------------------------------------------------------------------- 991108011 irby PHYSICS_OPERATOR Nov 8 1999 1:18:19:796PM . . . . . . . . . . . . . . . . . . . . Another Alternator test --- things look okay now --- problem with the timer relay. ---------------------------------------------------------------------------- 991108012 irby PHYSICS_OPERATOR Nov 8 1999 1:25:43:090PM . . . . . . . . . . . . . . . . . . . . EF1U test EF1U looks good ---------------------------------------------------------------------------- 991108013 irby PHYSICS_OPERATOR Nov 8 1999 1:37:28:670PM . . . . . . . . . . . . . . . . . . . . EF1L test EF1L okay ---------------------------------------------------------------------------- 991108014 irby PHYSICS_OPERATOR Nov 8 1999 1:46:36:090PM . . . . . . . . . . . . . . . . . . . . EF3 test EF3s look good ---------------------------------------------------------------------------- 991108015 irby PHYSICS_OPERATOR Nov 8 1999 2:02:53:466PM . . . . . . . . . . . . . . . . . . . . EF4 at 2000 amps --- forward EF4 okay ---------------------------------------------------------------------------- 991108016 irby PHYSICS_OPERATOR Nov 8 1999 2:05:09:170PM . . . . . . . . . . . . . . . . . . . . EFC test EFC looks good ---------------------------------------------------------------------------- 991108017 irby PHYSICS_OPERATOR Nov 8 1999 2:12:36:980PM . . . . . . . . . . . . . . . . . . . . EF2U test at 2000 Amps EF2U looks good ---------------------------------------------------------------------------- 991108018 irby PHYSICS_OPERATOR Nov 8 1999 2:25:32:123PM . . . . . . . . . . . . . . . . . . . . EF2L test at 2000 Amps Lots of AC ripple, about 300 amps pk-pk; may not have had all the supplies ---------------------------------------------------------------------------- 991108019 irby PHYSICS_OPERATOR Nov 8 1999 2:35:10:730PM . . . . . . . . . . . . . . . . . . . . Will try 50 kA TF test (coming back to EF2L) No good --- TF supply was not turned on at the control panel ---------------------------------------------------------------------------- 991108020 irby PHYSICS_OPERATOR Nov 8 1999 2:36:43:140PM . . . . . . . . . . . . . . . . . . . . 50 kA TF test TF looks good ---------------------------------------------------------------------------- 991108021 irby PHYSICS_OPERATOR Nov 8 1999 3:15:14:340PM . . . . . . . . . . . . . . . . . . . . EF2L breaker was not properly engauged. It pulled out with a "lamp" test. Should be okay now. FMIT#1, #3, and #4 online Plasma attempt Plasma --- 0.327 seconds Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -3.2777 -23.9530 -31.7063 -106.6544 dIp/dt (kA/ms): -2.0281 -2.7871 -2.9127 -5.8276 pressure (mTorr): 0.0493 0.0498 0.0487 0.0527 Bz0 (mT): -1.0609 0.8868 2.5863 19.9961 Br0 (mT): 0.8675 0.5962 -0.7121 -1.4939 Bz0 and Br0 changed considerably from 991029024 Pressure a little low ---------------------------------------------------------------------------- 991108022 irby PHYSICS_OPERATOR Nov 8 1999 3:26:01:186PM . . . . . . . . . . . . . . . . . . . . Trying again with no PCS changes Plasma for 1.87 seconds Lost all but channel 6 of TCI, but feedback worked Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -3.2777 -23.9530 -31.6833 -98.9011 dIp/dt (kA/ms): -1.9014 -2.7848 -2.9138 -5.4474 pressure (mTorr): 0.0539 0.0545 0.0533 0.0545 Bz0 (mT): -2.2639 1.4671 2.7175 20.5515 Br0 (mT): 1.3339 0.8816 -0.2665 -1.4852 ---------------------------------------------------------------------------- 991108023 irby PHYSICS_OPERATOR Nov 8 1999 3:55:58:466PM . . . . . . . . . . . . . . . . . . . . Dropped TF current to 144.5 kA for 5.2 T field RCUR reduced from 0.6730 to 0.6720 m Fizzle ---- Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1540 -31.1540 dIp/dt (kA/ms): -2.0247 -3.1683 -1.7748 -0.0011 pressure (mTorr): 0.0545 0.0545 0.0551 0.0558 Bz0 (mT): 0.1125 3.8507 5.9233 18.1466 Br0 (mT): 1.1601 0.1053 -0.7310 0.0841 ---------------------------------------------------------------------------- 991108024 irby PHYSICS_OPERATOR Nov 8 1999 4:09:42:466PM . . . . . . . . . . . . . . . . . . . . reduced Br0 by .5 mT IGT at 6.0e-7 Torr before the shot Plasma --- h-mode --- 1.86 seconds Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1310 -113.8554 dIp/dt (kA/ms): -2.0259 -3.1661 -3.7983 -5.8275 pressure (mTorr): 0.0539 0.0551 0.0533 0.0527 Bz0 (mT): -1.3388 1.0885 4.1680 21.4824 Br0 (mT): 0.5300 0.1741 -1.0415 -1.8325 79MB Resistance at 3.50 and 3.60 seconds: 1.58932 1.65319 ---------------------------------------------------------------------------- 991108025 irby PHYSICS_OPERATOR Nov 8 1999 4:32:40:483PM . . . . . . . . . . . . . . . . . . . . Reduced RCUR again from 0.672 to 0.671 m --- outer gap too small during h-mode Plasma --- 1.86 seconds --- a couple of h-modes Only one TCI channel (4) 79MB Resistance at 3.50 and 3.60 seconds: 1.65398 1.69814 Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -33.7384 -103.5177 dIp/dt (kA/ms): -2.0247 -3.2939 -2.2804 -6.0821 pressure (mTorr): 0.0564 0.0577 0.0570 0.0558 Bz0 (mT): -1.4472 1.0450 3.1639 20.0141 Br0 (mT): 0.5579 0.6506 -0.6759 -1.7890 Outer gap looks okay now ---------------------------------------------------------------------------- 991108026 irby PHYSICS_OPERATOR Nov 8 1999 4:56:48:386PM . . . . . . . . . . . . . . . . . . . . No PCS changes IGT at 1.0e-6 Torr just before shot Plasma --- 1.87 seconds --- short h-mode TCI #4 only Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1310 -103.4947 dIp/dt (kA/ms): -2.0259 -3.0405 -2.7871 -5.6998 pressure (mTorr): 0.0564 0.0564 0.0583 0.0570 Bz0 (mT): -0.6956 2.2257 5.0154 20.8563 Br0 (mT): 0.8683 0.4504 -0.9252 -1.2099 John Rice tells me we had lots of Moly from j-port that shot ---------------------------------------------------------------------------- 991108027 irby PHYSICS_OPERATOR Nov 8 1999 5:19:55:920PM . . . . . . . . . . . . . . . . . . . . No PCS changes IGT: 1.0e-6 Torr before shot Plasma: 1.87 seconds Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1310 -103.4947 dIp/dt (kA/ms): -2.0270 -2.7871 -2.7894 -5.3209 pressure (mTorr): 0.0564 0.0558 0.0577 0.0577 Bz0 (mT): -1.5263 2.7307 3.8393 20.5372 Br0 (mT): -0.0174 -0.6052 -0.6271 -1.3746 79MB Resistance at 3.50 and 3.60 seconds: 1.67922 1.66818 |
| Session Leader Comments | |||
| Nov 8 1999 03:06:07:797PM | 991108021 | Steve Wukitch | 021 early disruption 0.32 sec next shot: D-port: step up to 1 MW J-port : step up to 1 MW |
| Physics Operator Comments | |||
| Nov 8 1999 08:40:59:373AM | Jim Irby | Loaded shot 991029024 into PCS Did load/clean Did coldstart rtnode -- data loaded, A matrix responds rtnode -- data loaded, M matrix responds rtnode -- data loaded, PID matrix responds RT_NODE Done | |
| Nov 8 1999 09:12:01:480AM | 991108001 | Jim Irby | 10 kA OH1 test No excitation on Alternator? Running through shot to keep data system in sync. Alternator claims that it was ramping up --- no indication on our display.. |
| Nov 8 1999 09:31:24:903AM | 991108002 | Jim Irby | No excitation again! Ran through shot, but had no Oh1 current. Found that exciter gate had RED light. It has now been reset. Had to reboot PLCs, STATE, ACCESS, ALTERNATOR in control room and in alternator |
| Nov 8 1999 09:36:51:060AM | 991108003 | Jim Irby | Alternator okay now. Next shot should be OH1 test |
| Nov 8 1999 10:00:07:420AM | 991108004 | Jim Irby | Another try at an OH1 test OH1 looks good. |
| Nov 8 1999 10:00:53:827AM | 991108005 | Jim Irby | OH2U looks okay |
| Nov 8 1999 10:11:22:187AM | 991108006 | Jim Irby | OH2L OH2L looks good |
| Nov 8 1999 10:48:00:450AM | 991108007 | Jim Irby | We have been losing the Alternator exciter breaker when we go into RECOOL. Looks like the Alternator thinks we are having a type 1 TF fault. Yuri, Frank, and Jim are checking it out. Lost most of the data for this shot since INIT was bypassed. |
| Nov 8 1999 11:24:50:107AM | 991108008 | Jim Irby | Looks like type 1 fault is local to the exciter supply and has nothing to do with the TF. Now looks like it's the AC breaker to the exciter that is the problem. FMIT#3 and FMIT#4 have been checked out into the dummy load. Steve is going out to switch them over to the antenna. |
| Nov 8 1999 12:07:22:873PM | 991108009 | Jim Irby | Bypassed INIT again. Alternator ramped up okay to 12.8 kV. Lost excitation as we went into recool again. AC exciter breaker pulled again. |
| Nov 8 1999 01:18:19:797PM | 991108011 | Jim Irby | Another Alternator test --- things look okay now --- problem with the timer relay. |
| Nov 8 1999 01:25:43:090PM | 991108012 | Jim Irby | EF1U test EF1U looks good |
| Nov 8 1999 01:37:28:670PM | 991108013 | Jim Irby | EF1L test EF1L okay |
| Nov 8 1999 01:46:36:090PM | 991108014 | Jim Irby | EF3 test EF3s look good |
| Nov 8 1999 02:02:53:467PM | 991108015 | Jim Irby | EF4 at 2000 amps --- forward EF4 okay |
| Nov 8 1999 02:05:09:170PM | 991108016 | Jim Irby | EFC test EFC looks good |
| Nov 8 1999 02:12:36:980PM | 991108017 | Jim Irby | EF2U test at 2000 Amps EF2U looks good |
| Nov 8 1999 02:25:32:123PM | 991108018 | Jim Irby | EF2L test at 2000 Amps Lots of AC ripple, about 300 amps pk-pk; may not have had all the supplies |
| Nov 8 1999 02:35:10:730PM | 991108019 | Jim Irby | Will try 50 kA TF test (coming back to EF2L) No good --- TF supply was not turned on at the control panel |
| Nov 8 1999 02:36:43:140PM | 991108020 | Jim Irby | 50 kA TF test TF looks good |
| Nov 8 1999 05:32:46:577PM | 991108021 | Jim Irby | EF2L breaker was not properly engaged. It pulled out with a "lamp" test. Should be okay now. FMIT#1, #3, and #4 online Plasma attempt Plasma --- 0.327 seconds Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -3.2777 -23.9530 -31.7063 -106.6544 dIp/dt (kA/ms): -2.0281 -2.7871 -2.9127 -5.8276 pressure (mTorr): 0.0493 0.0498 0.0487 0.0527 Bz0 (mT): -1.0609 0.8868 2.5863 19.9961 Br0 (mT): 0.8675 0.5962 -0.7121 -1.4939 Bz0 and Br0 changed considerably from 991029024 Pressure a little low |
| Nov 8 1999 03:26:01:187PM | 991108022 | Jim Irby | Trying again with no PCS changes Plasma for 1.87 seconds Lost all but channel 6 of TCI, but feedback worked Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -3.2777 -23.9530 -31.6833 -98.9011 dIp/dt (kA/ms): -1.9014 -2.7848 -2.9138 -5.4474 pressure (mTorr): 0.0539 0.0545 0.0533 0.0545 Bz0 (mT): -2.2639 1.4671 2.7175 20.5515 Br0 (mT): 1.3339 0.8816 -0.2665 -1.4852 |
| Nov 8 1999 03:55:58:467PM | 991108023 | Jim Irby | Dropped TF current to 144.5 kA for 5.2 T field RCUR reduced from 0.6730 to 0.6720 m Fizzle ---- Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1540 -31.1540 dIp/dt (kA/ms): -2.0247 -3.1683 -1.7748 -0.0011 pressure (mTorr): 0.0545 0.0545 0.0551 0.0558 Bz0 (mT): 0.1125 3.8507 5.9233 18.1466 Br0 (mT): 1.1601 0.1053 -0.7310 0.0841 |
| Nov 8 1999 04:09:42:467PM | 991108024 | Jim Irby | reduced Br0 by .5 mT IGT at 6.0e-7 Torr before the shot Plasma --- h-mode --- 1.86 seconds Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1310 -113.8554 dIp/dt (kA/ms): -2.0259 -3.1661 -3.7983 -5.8275 pressure (mTorr): 0.0539 0.0551 0.0533 0.0527 Bz0 (mT): -1.3388 1.0885 4.1680 21.4824 Br0 (mT): 0.5300 0.1741 -1.0415 -1.8325 79MB Resistance at 3.50 and 3.60 seconds: 1.58932 1.65319 |
| Nov 8 1999 04:32:40:483PM | 991108025 | Jim Irby | Reduced RCUR again from 0.672 to 0.671 m --- outer gap too small during h-mode Plasma --- 1.86 seconds --- a couple of h-modes Only one TCI channel (4) 79MB Resistance at 3.50 and 3.60 seconds: 1.65398 1.69814 Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -33.7384 -103.5177 dIp/dt (kA/ms): -2.0247 -3.2939 -2.2804 -6.0821 pressure (mTorr): 0.0564 0.0577 0.0570 0.0558 Bz0 (mT): -1.4472 1.0450 3.1639 20.0141 Br0 (mT): 0.5579 0.6506 -0.6759 -1.7890 Outer gap looks okay now |
| Nov 8 1999 04:56:48:387PM | 991108026 | Jim Irby | No PCS changes IGT at 1.0e-6 Torr just before shot Plasma --- 1.87 seconds --- short h-mode TCI #4 only Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1310 -103.4947 dIp/dt (kA/ms): -2.0259 -3.0405 -2.7871 -5.6998 pressure (mTorr): 0.0564 0.0564 0.0583 0.0570 Bz0 (mT): -0.6956 2.2257 5.0154 20.8563 Br0 (mT): 0.8683 0.4504 -0.9252 -1.2099 John Rice tells me we had lots of Moly from j-port that shot |
| Nov 8 1999 05:19:55:920PM | 991108027 | Jim Irby | No PCS changes IGT: 1.0e-6 Torr before shot Plasma: 1.87 seconds Time (ms): 0 5 10 25 ---------------------------------------- Ip (kA): -2.7024 -23.3778 -31.1310 -103.4947 dIp/dt (kA/ms): -2.0270 -2.7871 -2.7894 -5.3209 pressure (mTorr): 0.0564 0.0558 0.0577 0.0577 Bz0 (mT): -1.5263 2.7307 3.8393 20.5372 Br0 (mT): -0.0174 -0.6052 -0.6271 -1.3746 79MB Resistance at 3.50 and 3.60 seconds: 1.67922 1.66818 |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:04:07:483AM | Test | Bad | no exitation from alt |
| 2 | 09:14:32:780AM | Test | Bad | no alternator excitation |
| 3 | 09:35:02:920AM | Test | Ok | Alternator Excitation test |
| 4 | 09:48:05:480AM | Test | Ok | OH1 only |
| 5 | 09:58:41:513AM | Test | Ok | Test ok OH2upper |
| 6 | 10:08:08:780AM | Test | Ok | Test ok OH2lower |
| 7 | 10:41:23:500AM | Test | Ok | No Power test for alternator exitation problem |
| 8 | 11:11:19:967AM | Test | Ok | ccccstate cycle for exiiter test |
| 9 | 11:55:39:107AM | Test | Ok | test |
| 10 | 12:00:22:077PM | Test | Ok | test |
| 11 | 01:14:51:623PM | Test | Ok | exiter breaker ok |
| 12 | 01:23:32:187PM | Test | Ok | EF1 lower test |
| 13 | 01:34:25:280PM | Test | Ok | ef1 lower ok |
| 14 | 01:44:32:200PM | Test | Ok | EF 3 test ok |
| 15 | 01:54:18:640PM | Test | Ok | ef4 test |
| 16 | 02:03:24:700PM | Test | Ok | efc test |
| 17 | 02:10:56:687PM | Test | Ok | ef2 upper test |
| 18 | 02:17:05:937PM | Test | Ok | ef2 lower noisey |
| 19 | 02:28:21:123PM | Test | Bad | TF not enabled |
| 20 | 02:34:51:700PM | Test | Ok | TF, no faults |
| 21 | 02:58:26:670PM | Test | Ok | no faults/fizzel |
| 22 | 03:19:35:327PM | Plasma | Ok | PLasma |
| 23 | 03:46:53:810PM | Plasma | Ok | fizzle |
| 24 | 04:04:21:733PM | Plasma | Ok | plasma |
| 25 | 04:24:01:967PM | Plasma | Ok | (null) |
| 26 | 04:45:51:950PM | Plasma | Ok | PLasma |
| 27 | 05:10:57:700PM | Plasma | Ok | (null) |