| Miniproposals | ||||||||||
| ||||||||||
|
| Operators | |
| Session leader(s): | Steve Wukitch,Steve Wukitch |
| Physics operator(s): | Steve Wolfe |
| Engineering operator(s): | Bill Cochran,Gary Dekow |
| Engineering Operator Run Comment |
| Run 991112 in support ofMP214: RF Conditioning MP225: |
| Session Leader Plans |
| Physics Operators Plans |
| Session Leader Summaries |
| Entered: Jul 7 2004 03:49:22:507PM |
| Author: To Be Determined |
| Run 991112 in support of MP214: RF Conditioning MP225: Determination of Mo Source, will ride along as possible. Run will BEGIN at 09:00 and END at 17:00 FMIT#3 and FMIT#4 should be made ready for operation. FMIT#1 should be warmed up and ready to go when needed. Setup power supplies from shot 99111005. This shot was a 5.2 T, 800 kA discharge, with a 1.5 s flattop. We will continue with 50 kA backporch on TF pulse. Two hours of ECDC in D2 at 2.e-4 Torr before the run (should be stopped by 08:00). Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid DISABLED fill B-side upper with 10 psi of H2 Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled Enable ECE and VUV. ********* Run plan ********* Evaluate effect of plasma density, gap, plasma shape, and edge gradient on J-port power density limit. Shot Schedule: Standard shot: J-port (0,pi,0,pi,) stepping up to moderate power levels BT = 5.2 T, Ip=800 kA, nl= 1.0x10^20 0.5, 0.75, and 1.3 MW each step is 0.3 sec 1. with J-port (0,pi,0,pi), scan density (0.7, 1.0, 1.3) (3 good shots) 2. with J-port (0,pi,0,pi,), scan outer gap 1.4, 1.0, and 0.6 cm. (3 good shots) 2a. dynamic gap scan at constant power (1 good shot) 3. compare J-port (0,pi,0,pi,), J-port (0,pi,pi,0), J3, J4 at moderate power levels in H-mode D-port at 1.4 MW (4 good shots) 4. Go to best condition and raise power level. (at least 5 shots) ---------------------------------------------------------------------------- 001 standard shot (loaded 991110005) lost #4 to xbar right before shot - tube arc (spark gap fired) fizzle 002 plasma - early disruption little H-mode 5.2 T, 0.8 kA nl target was 1.0 next shot: raise field to 5.6 T and aim for nl target of 0.7 003 plasma imto H-mode when RF comes on 5.6 T, 0.8 kA nl target was 0.7, reached next shot: repeat with increase in gap and power up to 1.5 MW total 004 plasma many little H-modes - many faults on #4 from prefl/pforw 5.6 T, 0.8 kA nl target was 0.7, reached next shot: target nl = 1.3 005 plasma J4 faulted after short pulse J3 faulted early nl-> 1.3 next shot: retune 006 plasma J4 faulted after short pulse J3 faulted early nl-> 1.3 lost TCI next shot: retune and ramp J3 this time cell access to fix TCI 007 plasma J4 faulted after short pulse J3 faulted early nl-> 1.3 next shot: retune and ramp J3 this time 008 plasma J4 faulted after short pulse J3 ramped and then faulted off nl-> 1.3 next shot: return to nl->1.0 and right gap of 1.4-1.5 cm 009 plasma early disruption comment: J-port really does not run at higher densities, particularly J3 density appears to be the best knob to change the power density limit next shot: return to nl->1.0 and right gap of 1.0 cm will probably have no interferometer data 010 plasma little H-modes gap was correct but the density may have been a bit higher next shot: nl->1.0 and right gap of 0.5 cm 011 plasma gap was 1.0 cm density was a bit low but acceptable right gap 0.7 cm next shot: nl->1.0 and scan right gap from 1.5-0 cm 012 plasma gap was 1.5-.25 cm J3 failed next shot: nl->1.0 and scan right gap from 1.5-0 cm 013 no density control next shot: nl->1.0 and scan right gap from 1.5-0 cm 014 plasma j3 and j4 had faults but recovered good gap sweep next shot: nl->1.0 and raise plasma z position 0.5 cm 015 plasma H-mode z position up by 0.5 cm from xrays z = 0.25 cm next shot: nl->1.0 and lower plasma z position by 0.5 cm 016 plasma H-mode z position down by 0.5 cm from xrays z = -0.6 cm next shot: nl->1.0 and scan z position from +0.75 -> -.75cm 017 plasma no outstanding effect next shot: constant shots with D-port z pos +0.5 cm 018 plasma early disruption H-mode z = 0.5 cm next shot: repeat with 2 MW from J and 1.4 MW from D 019 plasma H-mode z = 0.5 cm few faults on #3 next shot: repeat with 2.75 MW from J and 1.4 MW from D 020 plasma - blew away the plasma at ~0.7 sec next shot: repeat with lower density (30%) 2.75 MW from J and 1.4 MW from D 021 plasma #4 had a tube arc during the discharge #3 had a bizarre event where the anode current went negative breakpulled next shot: J down for break D-port only 022 plasma gruesome 023 plasma D-port only good EDA last shot of the campaign ******* Summary ******* We were successful in performing density, gap, and vertical position scans. With respect to gap and vertical position, any other combination other than the one we have been running appeared to have less impurities. At high densities, J3 would not run. It appeared to arc consistently and fail after 9 retries. The antenna was more consistent at low density in terms of coupling power. We had a bad event with FMIT#3 on 021. We should do some dummy load testing next week to verify operation. Signing off. |
| Physics Operator Summaries |
| Entered: Jul 7 2004 04:37:10:113PM |
| Author: To Be Determined |
| Physics Operator's summary for Friday, Nov 12, 1999. MP#214: ICRF (J-port) MP#225: Impurity ssources (piggyback) SL: Wukitch PO: wolfe EO: Cochran,Dekow Setup/Run plan -------------- Run will BEGIN at 09:00 and END at 17:00. ***THIS WILL BE THE FINAL RUN OF THE 1999 OPERATING CAMPAIGN*** FMIT#3 and FMIT#4 should be made ready for operation. FMIT#1 should be warmed up and ready to go when needed. Setup power supplies from shot 991110005. This shot was a 5.2 T, 800 kA discharge, with a 1.5 s flattop. We will continue with 50 kA backporch on TF pulse. Two hours of ECDC in D2 at 2.e-4 Torr before the run (should be stopped by 08:00). Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid DISABLED fill B-side upper with 10 psi of H2 Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled Enable ECE and VUV. IMPORTANT NOTE: The last three or so shots of the day, beginning at around 16:15, will be run with the TF cooling tuned off, to prepare for the possibility that we will want to remove the cylinder before the next campaign. These shots will be run with the fizzle detector to the TF disabled, and will continue until the upper arms reach a maximum temperature of -50C. Irby and/or Gwinn will oversee this magnet warm-up procedure. ********* Run plan ********* Evaluate effect of plasma density, gap, plasma shape, and edge gradient on J-port power density limit. Shot Schedule: Standard shot: J-port (0,pi,0,pi,) stepping up to moderate power levels BT = 5.2 T, Ip=800 kA, nl= 1.0x10^20 0.5, 0.75, and 1.3 MW each step is 0.3 sec 1. with J-port (0,pi,0,pi), scan density (0.7, 1.0, 1.3) (3 good shots) 2. with J-port (0,pi,0,pi,), scan outer gap 1.4, 1.0, and 0.6 cm. (3 good shots) 2a. dynamic gap scan at constant power (1 good shot) 3. compare J-port (0,pi,0,pi,), J-port (0,pi,pi,0), J3, J4 at moderate power levels in H-mode D-port at 1.4 MW (4 good shots) 4. Go to best condition and raise power level. (at least 5 shots) Results: -------- The machine ran well, and most of the investigations were accomplished. We added a step 2b, to determine the effect of raising and lowering ZCUR on the RF performance. The phase comparison was not attempted. Total power was raised to 4MW for a brief period on shot 20, before it disrupted. Up to 3.5 MW was sustained on shot 19, but the Mo radiation was very high, and heating was poor. On shot 21, FMIT#3 had a crowbar during the pulse, and the anode current trace appeared to go very negative. Wukitch decided not to risk additional operation with J-port. The last two shots were run with D-port alone. Shot 23 had 1.5MW from D-port, and got a good looking H-mode, but only reached ~80kJ. The TCI laser became unreliable, so we switched over to NL_ZMETER control for shots 10-12, and 14-23. This worked reasonably well, although there was some thrashing in determining the correct setpoint. For shot 11 and thereafter, the gain was raised from 5 to 9. Irby decided not to go through the magnet warm-up procedure, so we will have to use inductive heating with the EF4's if we need to pull the cylinder. Scorecard: ---------- Tests 0 Duds 0 Fizzles 1 Plasmas 22 ------- -- Shots 23 |
| Session Leader Comments |
| Physics Operator Comments | |||
| Nov 12 1999 07:23:24:043AM | Steve Wolfe | Load from 991110005 Load/CLean JAS is apparently dealing with a data syste problem. Try doing a coldstart anyway Coldstart ok. Logfile ok Josh seems to have fixed the problem | |
| Nov 12 1999 07:29:10:450AM | Steve Wolfe | Run 991112 in support of MP214: RF Conditioning MP225: Determination of Mo Source, will ride along as possible. Run will BEGIN at 09:00 and END at 17:00. ***THIS WILL BE THE FINAL RUN OF THE 1999 OPERATING CAMPAIGN*** FMIT#3 and FMIT#4 should be made ready for operation. FMIT#1 should be warmed up and ready to go when needed. Setup power supplies from shot 991110005. This shot was a 5.2 T, 800 kA discharge, with a 1.5 s flattop. We will continue with 50 kA backporch on TF pulse. Two hours of ECDC in D2 at 2.e-4 Torr before the run (should be stopped by 08:00). Gas setup - fill B-top with 6 psi of D2 Hybrid enabled fill B-side lower with 1 psi of Ar Hybrid DISABLED fill B-side upper with 10 psi of H2 Hybrid DISABLED fill C-side with 30 psi of D2 Hybrid enabled Enable ECE and VUV. IMPORTANT NOTE: The last three or so shots of the day, beginning at around 16:15, will be run with the TF cooling tuned off, to prepare for the possibility that we will want to remove the cylinder before the next campaign. These shots will be run with the fizzle detector to the TF disabled, and will continue until the upper arms reach a maximum temperature of -50C. Irby and/or Gwinn will oversee this magnet warm-up procedure. ********* Run plan ********* valuate effect of plasma density, gap, plasma shape, and edge gradient on J-port power density limit. Shot Schedule: Standard shot: J-port (0,pi,0,pi,) stepping up to moderate power levels BT = 5.2 T, Ip=800 kA, nl= 1.0x10^20 0.5, 0.75, and 1.3 MW each step is 0.3 sec 1. with J-port (0,pi,0,pi), scan density (0.7, 1.0, 1.3) (3 good shots) 2. with J-port (0,pi,0,pi,), scan outer gap 1.4, 1.0, and 0.6 cm. (3 good shots) 2a. dynamic gap scan at constant power (1 good shot) 3. compare J-port (0,pi,0,pi,), J-port (0,pi,pi,0), J3, J4 at moderate power levels in H-mode D-port at 1.4 MW (4 good shots) 4. Go to best condition and raise power level. (at least 5 shots) | |
| Nov 12 1999 09:07:54:840AM | 991112001 | Steve Wolfe | shot 1: No RF people in evidence. Increase pre-puff from 16->18msec and take a shot. fizzle , we're not off to a good start. BR looks very positive, around 3mT. Next shot: decrease BR_0 from -.0005 to -.0025 |
| Nov 12 1999 09:32:22:763AM | 991112002 | Steve Wolfe | shot 2: decrease BR_0 from -.0005 to -.0025 plasma, disrupts at 1.15 Br still starts positive, drops to zero. BD a little late, still Next shot: raise field to 5.6tesla, drop ne4 to 0.7e20 |
| Nov 12 1999 09:36:35:750AM | 991112002 | Steve Wolfe | shot 2: decrease BR_0 from -.0005 to -.0025 plasma, disrupts at 1.15 Br still starts positive, drops to zero. bd ok. Next shot: raise field to 5.6tesla, drop ne4 to 0.7e20, drop pre-puff to 16 |
| Nov 12 1999 09:53:46:390AM | 991112003 | Steve Wolfe | shot 3: raise field to 5.6tesla, drop ne4 to 0.7e20, drop pre-puff to 16 plasma, full length, h-modes. Big injection at .27 almost did it in. looks like some non-thermals early. outer gap is around 5mm Next shot: raise pre-puff to 18ms, devcrease RCUR from .671->.669 |
| Nov 12 1999 10:10:55:280AM | 991112004 | Steve Wolfe | shot 4: raise pre-puff to 18ms, decrease RCUR from .671->.669 plasma, h-modes, lots of junk. RF to 1.4MW early injection at .11sec. Next shot: raise density to 1.3e20 |
| Nov 12 1999 10:30:37:733AM | 991112005 | Steve Wolfe | shot 5: raise density to 1.3e20, increase pg3 seg 2 maint level to ~40V plasma, no hmodes, no j3, j4 max is 0.5MW nl4=1.3 next shot: repeat, with RF? |
| Nov 12 1999 10:59:33:950AM | 991112006 | Steve Wolfe | shot 6: repeat, with RF? disrupts at 1.43sec, JHI reports no TCI. No density traces or feedback. TS density is 1.5e20/m3 next shot: Drop pre-fill, otherwise repeat, (with TCI) |
| Nov 12 1999 11:43:37:000AM | 991112007 | Steve Wolfe | shot 7: Drop pre-fill to 16msec, otherwise repeat, (with TCI) plasma, no hmodes, not much rf, only j4 at .5MW. Injections at .5,.93,1.03 Next shot: Shit shooter injecting C at 0.5 |
| Nov 12 1999 12:01:48:450PM | 991112008 | Steve Wolfe | shot 8: One more try at RF at the high density. Shit shooter injecting C at 0.5 plasma, no hmodes, no j3. Next shot: down to 1.0e20, increase gap to 1.5 or so. |
| Nov 12 1999 12:20:08:543PM | 991112009 | Steve Wolfe | shot 9: down to 1.0e20, lower pg3 seg 2, rcur from .669->.666 plasma, h-modes, junk, disrupts at 1.41; 1.5MW, hardly any heating. TCI dropped fringes, but feedback was ok. gap was 1.5-1.4cm. Next shot: 1cm gap |
| Nov 12 1999 12:43:51:403PM | 991112010 | Steve Wolfe | shot 10: RCUR back to .669 from .666. Irby reports TCI is dead; change to NL_ZMETER from 990202014, request level is 0.4, extend to 1.5sec plasma, h-mode, injections but it survived. RF to 1.25MW TCI is indeed dead. Irby to cell to try to resurrect. Next shot: increase gain on ZMETER, go to .5cm gap |
| Nov 12 1999 01:22:34:310PM | 991112011 | Steve Wolfe | shot 11: increase gain on NL_ZMETER from 5.->9., go to .5cm gap (RCUR from .669->.671) plasma, h-mode, TCI is back for now. INjection at 1.38 almost kills plasma. NL4 is only .85e20. Next shot: increase NL_ZMETER from .4 ->.55; dynamic gap scan. |
| Nov 12 1999 01:41:49:450PM | 991112012 | Steve Wolfe | shot 12: increase NL_ZMETER from .4 ->.55; dynamic gap scan: RCUR from .666 to .674 over .55s : 1.4sec plasma, no h-mode, no j3. Got 1.2e20. gap scan from 1.9cm : .3cm Next shot: put NL4 control back on (1.e20); RF will try for both of J |
| Nov 12 1999 02:05:10:250PM | 991112013 | Steve Wolfe | shot 13: put NL4 control back on (1.e20); RF will try for both of J plasma, TCI gone again!. Lots of density, judging from the TV disrupts at 1.6sec. Ran out of oh1, ef1u, ef1l; ef2's go to zero. no rf. TS says 4e20 Next shot: back to NL_ZMETER, ask for 0.48 |
| Nov 12 1999 02:19:57:327PM | 991112014 | Steve Wolfe | shot 14: back to NL_ZMETER, ask for 0.48 plasma, some big injections, big bite at 1.37sec, but survives No J3. Still getting nl4 of 1.2 (it came back) Next shot: Gap back to 1cm, drop the density |
| Nov 12 1999 02:40:20:140PM | 991112015 | Steve Wolfe | shot 15: NL_ZMETER ask for 0.44, eliminate gap sweep, RCUR=.669, raise ZCUR by 0.5cm plasma, hmodes, rf. Next shot: down by .5cm from original |
| Nov 12 1999 02:59:49:577PM | 991112016 | Steve Wolfe | shot 16: down by .5cm from original plasma, h-modes, rf Next shot: ramp zcur |
| Nov 12 1999 03:19:50:187PM | 991112017 | Steve Wolfe | shot 17: ramp zcur -.0075 to -.0225 plasma, hmodes, rf. Next shot: PUt ZCUR "at the midplane or a little above" |
| Nov 12 1999 03:42:24:250PM | 991112018 | Steve Wolfe | shot 18: ZCUR=-.009, RF will turn on D-port. plasma, hmodes, disrupts at 1.50 D-port up to 1.5MW, 0.6:1.1sec, J@1.5 until 1.5 Next shot: RF will raise J power some more. |
| Nov 12 1999 03:58:13:077PM | 991112019 | Steve Wolfe | shot 19: RF will raise J power some more. No PCS changes plasma, h-modes, some injections, neuts to 4e12. RF up to 3.6MW. D=1.5,J=2 Next shot: more power. |
| Nov 12 1999 04:16:40:937PM | 991112020 | Steve Wolfe | shot 20: more power? Disrupts at 0.74 sec. 2pi diode hit 2MW before the big one. Got to 4MW, briefly. Next shot: lower density. |
| Nov 12 1999 04:33:44:793PM | 991112021 | Steve Wolfe | shot 21: lower density. NL_Zmeter from .44 to .25. I have no clue what density I will get, since Z goes up as n goes down. It may well turn the gas off completely, since I also lowered the pg3 maintenance level to 10V. plasma, hmode, J3&4 dropped out. NL4 about .7e20. Next shot: "try to get 3&4 to stay on", bring nl up a littel |
| Nov 12 1999 04:52:22:933PM | 991112022 | Steve Wolfe | shot 22: Transmitter 3 may have a problem. That will be all for J port. Take a shot with D only. plasma, h-modes, lots of radiation. Next shot: raise nl_zmeter back to .44 |
| Nov 12 1999 05:09:22:090PM | 991112023 | Steve Wolfe | shot 23: raise nl_zmeter back to .44, increase pg3 level to 25V plasma, decent hmode. neuts at 3e12. END OF THE 1999 CAMPAIGN! |
| Engineering Operator Comments | ||||
| Shot | Time | Type | Status | Comment |
| 1 | 09:00:22:890AM | Plasma | Ok | Fizzle |
| 2 | 09:26:25:763AM | Plasma | Ok | plasma |
| 3 | 09:44:22:747AM | Plasma | Ok | Plasma |
| 4 | 10:03:15:373AM | Plasma | Ok | plasma |
| 5 | 10:24:18:793AM | Plasma | Ok | (null) |
| 6 | 10:46:01:967AM | Plasma | Ok | (null) |
| 7 | 11:36:49:513AM | Plasma | Ok | (null) |
| 8 | 11:55:50:843AM | Plasma | Ok | (null) |
| 9 | 12:11:57:153PM | Plasma | Ok | (null) |
| 10 | 12:31:20:857PM | Plasma | Ok | (null) |
| 11 | 01:14:07:700PM | Plasma | Ok | (null) |
| 12 | 01:34:40:250PM | Plasma | Ok | (null) |
| 13 | 01:55:47:480PM | Plasma | Ok | (null) |
| 14 | 02:15:05:093PM | Plasma | Ok | (null) |
| 15 | 02:35:18:420PM | Plasma | Ok | (null) |
| 16 | 02:54:04:500PM | Plasma | Ok | (null) |
| 17 | 03:12:53:687PM | Plasma | Ok | (null) |
| 18 | 03:32:50:577PM | Plasma | Ok | (null) |
| 19 | 03:50:48:077PM | Plasma | Ok | (null) |
| 20 | 04:10:42:217PM | Plasma | Ok | (null) |
| 21 | 04:27:29:997PM | Plasma | Ok | (null) |
| 22 | 04:47:18:187PM | Plasma | Ok | (null) |
| 23 | 05:06:04:717PM | Plasma | Ok | (null) |