Facility capabilities

A short summary of the expected machine capabilities/parameters/diagnostics for the 2007 campaign follows. For more thorough information, please visit the C-Mod website or contact us.

C-Mod Parameters

  • BT from ~2T to 8T
  • IP up to 2 MA
  • central ne up to ~1x1021 m-3
  • Ti~Te up to ~5 keV
  • elongation from 0.9 to 1.7
  • triangularity from ~0.3 to 0.75
  • single null (lower or upper), double null or limited configuration
  • reversal of BT and IP direction possible for brief periods 

New diagnostics and facility features to be  implemented for the 2007 campaign:

  • Cyropump in upper divertor for improved density control (~10kL/s pumping speed)
  • Prototype tungsten lamellae tiles in divertor
  • Surface science station for deposition studies
  • Additional magnetic pick-up coils for low-n mode resolution
  • Bolometry upgrades
  • Improved inner wall scanning Langmuir probe high-field side flow measurement
  • Prototype fast-ferrite tuner for real-time ICRF tuning
  • 7° rotation of diagnostic neutral beam for improved MSE
  • Dust injection and laser scattering detection

Auxiliary Plasma Heating/Current Drive Capabilities:

  • ICRH: routine forward power up to 5MW. Source freq. variable from 40 to 80MHz. Heating or current drive phasing.
  • Lower Hybrid wave launcher with source power up to 3 MW

Additional operating features

  • Long-pulse diagnostic neutral beam (1.5 sec duration)
  • External correction coils (A-coils) for non-axisymmetric field studies and locked mode amelioration
  • Active MHD antennas
  • Digital plasma control system for flexible real-time feedback
  • Massive impurity gas jet for disruption mitigation studies
  • Li/impurity pellet injection
  • Impurity gas puff system

Selected Diagnostics

  • Standard magnetic diagnostics
  • ne(r) via Thomson Scattering, interferometry, and visible bremsstrahlung,
  • Te(r) via Thomson scattering and ECE
  • CXRS measurements of Ti, toroidal and poloidal rotation
  • Core toroidal rotation measurements via spectroscopy
  • Core Ti profile measurements via spectroscopy
  • Central Ti from neutron rate
  • Impurity measurements via spectroscopy (x-ray, VUV, visible)
  • Core and edge bolometry
  • Density fluctuation measurements via phase contrast imaging, microwave reflectometry
  • Edge and SOL profiles via reciprocating probes
  • SOL fluctuation measurements via probes and light emission
  • Hard x-ray pinhole camera for fast electron measurements
  • Compact neutral particle analyzer