Temperature Modification: Yes, through NKEMOD=0,-1 and TKEMOD=0.150
Density Modification: Yes, fixed at 0.2 s
Chi Modification: No
Current to limit q(0) set: Yes, used: No
Comments:
This case is a duplicate of 2212 testing a more modern namelist.
It seems to work fine and will possibly be used as a template in runs after TRANSP 2246.
The bootstrap fraction is considerably lower in this run at 0.115, and the q profile is also modified.
I think this has to do with turn on time of the LH. Need to change the LH on time to 0.15 s like 2212 to check. Also need
to include the option to run with more zones, that is, increase spatial resolution.
For more information about the run see the input namelist.
The image below plots the total current vs time. The current is mostly supplied by LH.
Legend:
Total Current: White
Lower Hybrid: Red
Ohmic Current: Green
Bootstrap Current: Blue
The figure below shows the actual power spectrum from the TRANSP output.